Compared to the designated European upper reference level of 300 Bq m-3 for indoor radon concentrations, the contribution of building materials appears to be low. Taking into account the recommended limit of 100 Bq m-3 by WHO as well as the increased dose conversion factor, the contribution of building products is quite relevant, especially at low air change rates. Therefore in Germany a maximum contribution of building materials to the indoor radon concentration of 20 Bq m-3 is discussed.
Because measurements of low concentrations are associated with high uncertainties, radon exhalation rates are often determined in chambers without air exchange and indoor conditions are extrapolated.
This study investigated the suitability of direct low level radon measurement under simulated indoor conditions with commercially available instruments, based on the preliminary EU standard for the determination of the emission of volatile organic compounds (VOC) from building materials in test chambers.
Measurements are possible with a relative uncertainty ranging from 7 to 18 %. Four major problems were identified:
1. Detector sensitivity: Two of four instruments were identified to determine low radon concentrations in a sufficiently short measuring time.
2. Thoron discrimination: Thoron was discriminated by aging the sampled air in a hose before the detector.
3. Sampling setup: An external chamber measurement was feasible as long as all main system parts were under slight overpressure.
4. Blank value: For VOC-emission testing ambient air, conditioned by filtration and sorption, is used to generate an air exchange. Regarding radon, this treatment is non-effective. If all instrument background levels have been characterized, the blank value must be measured with a second detector in parallel.
Earth, timber, fibre boards and insulation materials based on wooden and other natural fibres offer a variety of properties beneficial for eco innovative constructions that are able to improve the energy and resource efficiency of buildings.
Due to their porosity, natural building materials are vapour active and are able to buffer moisture. In combination with highly insulated and airtight but vapour permeable building envelopes, modern earth-timber constructions provide stable indoor humidity levels and can therefore be naturally ventilated while achieving highest energy efficiency standards. Experimental evidence suggests that monitored pilot buildings in Berlin do show healthy indoor air humidity levels (around 50%) in wintertime, while mechanically ventilated buildings demonstrate significantly lower values (around 25%), which have to be considered as uncomfortable and unhealthy.
The application of building materials being poor in chemical emissions, particularly volatile organic compounds (VOC) and radon, improves the indoor air quality further, so that intermittent ventilation twice a day will be sufficient to provide healthy indoor air quality. The air quality in critical rooms (e.g. small bedrooms), demonstrating a smaller air volume, should be monitored if appropriate ratios of room size to occupancy level cannot be realised.
Through night time ventilation in summer, vapour active earth-timber constructions provide evaporative cooling (humidity adsorption at night time and desorption during the day). As a result, indoor temperatures of earth-timber buildings range around 8 °C below the outside temperature peak, when an appropriate glazing ratio is reflected. The EU funded research project H-house is investigating various construction materials regarding water vapour adsorption as well as emission and absorption of harmful substances. Based on this investigation new wall constructions are designed to provide a healthier indoor environment.