This study explores the acceleration of material design in the concrete industry, focusing on improving carbonation resistance, a key factor in the durability of concrete structures. Traditional tests for carbonation resistance are lengthy, but with the construction industry aiming for sustainable production, finding a balance between carbonation resistance and CO2 footprint is crucial. Our research employs two innovative methods: 1. Applying the Sequential Learning App for Materials Discovery (SLAMD), an AI materials design framework, to an extensive dataset of real-world concrete compositions to selectively test materials that meet market demands: maximum durability, optimal eco-durability, and the best cost-durability trade-off. 2. Investigating 1H Nuclear Magnetic Resonance (NMR) relaxometry as a quick alternative for characterizing carbonation behavior, as it saves time compared to traditional tests and assesses the complete material's pore space. Specific NMR features are then integrated into the material design model, with the model's performance compared against traditional approaches. The results of our study are compelling, demonstrating that materials can be precisely tailored to meet specific requirements with minimal data points. This marks a significant stride in the concrete industry, indicating that NMR-based, low-fidelity surrogate characterizations, combined with a focused, data-driven design approach, can substantially accelerate the development of durable, sustainable concrete mixtures.
Nuclear magnetic resonance (NMR) with focus on 1H protons is increasingly applied for non-destructive testing applications. Besides mobile NMR, laboratory devices such as the NMR core-analyzing tomograph are used. As their magnetic field is more homogeneous, they enable measurements with higher signal-to-noise ratios (SNR), but with limited sample sizes. The tomograph presented here (8.9 MHz) was constructed for a maximum sample diameter of 70 mm and length of up to 1 m. The resolution, the echo time (min. 50 µs), the SNR and the measurement type can be adjusted by means of exchangable coils. The tomograph enables measurements along the complete sensitive length, slice-selective and even 2- or 3-dimensional measurements. A movable sample lifting system thereby allows a precise positioning of the sample.