Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Erscheinungsjahr
- 2024 (31) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (13)
- Vortrag (10)
- Posterpräsentation (4)
- Beitrag zu einem Tagungsband (3)
- Buchkapitel (1)
Schlagworte
- Additive manufacturing (5)
- Additive Manufacturing (4)
- In situ monitoring (3)
- PBF-LB/M (3)
- Additive Fertigung (2)
- Computed Tomography (2)
- Emissivity (2)
- Gas Tomography (2)
- Geführter Ultraschall (2)
- Inverse Verfahren (2)
- Mobile Robotic Olfaction (2)
- Plume (2)
- SBFEM (2)
- TDLAS (2)
- Wirbelstromprüfung (2)
- X-ray computed tomography (2)
- Absorption correction (1)
- Adhesives (1)
- Aerial Robot (1)
- Air Void System (1)
- Anlage (1)
- Automated image analysis (1)
- Automation (1)
- Binder Jetting (1)
- Carbonation resistance (1)
- Cement and concrete (1)
- Ceramic matrix composites (1)
- Ceria (1)
- Composite (1)
- Computed tomography (1)
- Crack growth (1)
- Craze-crack mechanism (1)
- DICONDE (1)
- Damage imaging (1)
- Defects (1)
- Dental composite materials (1)
- Diffraction (1)
- Diffraction Elastic Constants (1)
- Digital Twin (1)
- Druckanschwingen (1)
- Eigenspannungsmessung (1)
- Environmental stress cracking (ESC) (1)
- Epoxy (1)
- Ermüdungsrisswachstum (1)
- FAIR research data management (1)
- FEM (1)
- FEM Simulation (1)
- Fatigue (1)
- Fatigue damage (1)
- Fracture (1)
- Full notch creep test (FNCT) (1)
- Gas Camera (1)
- Gastomographie (1)
- General Materials Science (1)
- Heat treatment (1)
- High-temperature ceramics (1)
- Imaging (1)
- Implants (1)
- In-Situ Testing (1)
- Inconel 718 (1)
- Industrial and Manufacturing Engineering (1)
- Interphase residual stress (1)
- Laboratory energy-dispersive X-ray diffraction (EDXRD) (1)
- Laser Powder Bed fusion (1)
- Laser powder bed fusion (1)
- Laser scanning microscopy (LSM) (1)
- Lattices (1)
- Leitfähigkeitsmessung (1)
- Low-cycle fatigue (1)
- Machine Learning (1)
- Machine-Learning Segmentation (1)
- Micro X-ray fluorescence spectroscopy (1)
- Microstructure Analysis (1)
- Mobile Sensorik (1)
- NDT (1)
- Neutronendiffraktion (1)
- Node-release (1)
- Non-Destructive Testing (1)
- Non-weldable superalloy (1)
- Nondestructive testing (NDT) (1)
- Nuclear magnetic resonance (1)
- PBF/LB (1)
- PBFLB/M AlSi10Mg alloy (1)
- Phase transformation (1)
- Plasticity (1)
- Porosity analysis (1)
- Predictability (1)
- Prozessüberwachung (1)
- Reproducibility (1)
- SLAMD app (1)
- Scanning electron microscopy (1)
- Schienenprüfung (1)
- Self-healing (1)
- Sensors (1)
- Signal processing (1)
- Simulation (1)
- Sintering (1)
- Slow crack growth (SCG) (1)
- Solidification cracking (1)
- Stress-relief heat-treatments (1)
- Synchrotron X-ray CT (1)
- Synchrotron X-ray diffraction (SXRD) (1)
- Synchrotron X-ray refraction (1)
- Synchrotron X-ray refraction radiography (1)
- Tensile strength (1)
- Testing methodologies (1)
- Thermoplastic (1)
- Time-offlight Diffraction (TOFD) (1)
- Tunable Diode Laser Absorption Spectroscopy (1)
- Ultraschallprüfung (1)
- Ultrasonic Testing (1)
- Ultrasonic guided waves (UGWs) (1)
- Ultrasonics (1)
- Welded (1)
- X-ray CT (1)
- X-ray Computed tomography (1)
- X-ray computed tomography (CT) (1)
- Zerstörungsfreie Prüfung (1)
- Zirconia (1)
- microstructural changes (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (31) (entfernen)
Das Ausbreitungsverhalten geführter Ultraschallwellen ermöglicht die großflächige Prüfung von Platten und schalenförmigen Bauteilen wie Rohren und Laminaten auf Fehlstellen von wenigen Prüfpunkten aus. Während die beschränkte Divergenz der geführten Wellen die Ultraschallprüfung begünstigt, erschwert das dispersive und multimodale Verhalten der Lamb-Wellen die Auswertung der Ultraschallsignale. Die dispersive und multimodale Wellenausbreitung verkompliziert die Bestimmung der Fehlerposition bei der Auswertung der Geschwindigkeiten einzelner Wellenpakete. Zudem ist es herausfordernd, einen einfachen Zusammenhang zwischen den Reflexionen der Fehlstelle und deren Größe und Form herzustellen. Eine Möglichkeit zur genauen Bestimmung der Fehlerposition und -geometrie bietet der direkte Vergleich der Messsignale mit den Signalen aus einem Simulationsmodell. Die Nachbildung des Schadens im Simulationsmodell stellt ein inverses Problem dar, das iterativ gelöst werden kann, indem ein Vorwärtsmodell immer weiter optimiert wird. Klassische Ansätze wie die Finite Elemente Methode (FEM) sind für die Simulation von Ultraschallwellen aufgrund der kleinen Wellenlängen im Vergleich zur Bauteilgröße meist ineffizient. Aus diesem Grund basiert das vorgestellte Vorwärtsmodell auf der semi-analytischen Scaled Boundary Finite Element Method (SBFEM), die große Teile der Wellenausbreitung analytisch berechnet. In diesem Beitrag wird die Validierung des zweidimensionalen Modells an Platten mit einer rechteckigen Nut als Ersatzfehler präsentiert und es werden erste Schritte zur Validierung von 3D-Modellen vorgestellt.
Das Ausbreitungsverhalten geführter Ultraschallwellen ermöglicht die großflächige Prüfung von Platten und schalenförmigen Bauteilen wie Rohren und Laminaten auf Fehlstellen von wenigen Prüfpunkten aus. Während die beschränkte Divergenz der geführten Wellen die Ultraschallprüfung begünstigt, erschwert das dispersive und multimodale Verhalten der Lamb-Wellen die Auswertung der Ultraschallsignale. Die dispersive und multimodale Wellenausbreitung verkompliziert die Bestimmung der Fehlerposition bei der Auswertung der Geschwindigkeiten einzelner Wellenpakete. Zudem ist es herausfordernd, einen einfachen Zusammenhang zwischen den Reflexionen der Fehlstelle und deren Größe und Form herzustellen. Eine Möglichkeit zur genauen Bestimmung der Fehlerposition und -geometrie bietet der direkte Vergleich der Messsignale mit den Signalen aus einem Simulationsmodell. Die Nachbildung des Schadens im Simulationsmodell stellt ein inverses Problem dar, das iterativ gelöst werden kann, indem ein Vorwärtsmodell immer weiter optimiert wird. Klassische Ansätze wie die Finite Elemente Methode (FEM) sind für die Simulation von Ultraschallwellen aufgrund der kleinen Wellenlängen im Vergleich zur Bauteilgröße meist ineffizient. Aus diesem Grund basiert das vorgestellte Vorwärtsmodell auf der semi-analytischen Scaled Boundary Finite Element Method (SBFEM), die große Teile der Wellenausbreitung analytisch berechnet. In diesem Beitrag wird die Validierung des zweidimensionalen Modells an Platten mit einer rechteckigen Nut als Ersatzfehler präsentiert und es werden erste Schritte zur Validierung von 3D-Modellen vorgestellt.
Self-healing polymers have been developed to improve durability and reduce costs associated with maintenance during service. The addition of thermoplastics to thermosets to produce mendable polymers appears as a promising selfhealing technique. In this study, poly (ethylene-co-methacrylic acid) (EMAA) was added to epoxy resin and the effects of EMAA addition on epoxy properties were evaluated. Specimens with two different contents of thermoplastic and particles sizes were manufactured. A two-level full factorial experimental design was used to evaluate the effect of particle size and particle content on properties of epoxy modified with addition of EMAA. Tensile tests and dynamic mechanical analysis (DMA) were used and the evaluated responses were tensile strength, modulus of elasticity, and glass transition temperature (Tg). X-ray computed tomography (XCT) was used to investigate particle size and concentration after manufacturing. It was found that the particle concentration has greater effects on stress–strain behavior of epoxy while Tg was not significantly affected by neither of the analyzed entrance variables.
Various software products for the simulation of industrial X-ray radiography have been developed in recent years (e.g., aRTist 2, CIVA CT, Scorpius XLab, SimCT, Wilcore) and their application potential has been shown in numerous works. However, full systematic approaches to characterise a specific CT system for these simulation software products to obtain a truthful digital twin are still missing. In this contribution, we want to present two approaches to obtain realistic grey values in X-ray projections in aRTist 2 simulations based on measured projections. In aRTist 2, the displayed grey value of a pixel is based on the energy density incident on that pixel.
The energy density is calculated based on the X-ray tube spectrum, the attenuation between source and detector as well as an energy-dependent sensitivity curve of the detector. The first approach presented in this contribution uses the sensitivity curve as a free modelling parameter. We measured the signal response at different thicknesses of Al EN-AW6082 at different tube voltages (i.e., different tube spectra). We then regarded the grey values displayed by these projections as a data regression respectively an optimisation problem and obtained the sensitivity curve that is best able to reproduce the measured behaviour in aRTist 2. The resulting sensitivity curve does not necessarily hold physical meaning but is able to simulate the real system behaviour in the simulation software.
The second approach presented in this contribution is to estimate the sensitivity curve based on assumptions about the characteristics of the scintillation detector (e.g., scintillator material, scintillator thickness and signal processing characteristics). For this approach, a linear response function (linear relationship between the deposited energy per pixel and the resulting grey value) is assumed. If the detector characteristics, which affect the simulated deposited energy, are properly modelled, the slope and offset of the response function to match the measured grey values should be the same for different tube spectra. As the offset is constant and given by the grey values measured at no incident radiation, the slope is the remaining parameter to evaluate the success of the detector modelling. We therefore adapted the detector characteristics by changing the detector setup until the slope was nearly the same for all measured tube spectra. We are aware that the resulting parameters of the scintillator material and thickness might not be the real ones, but with those modelling parameters we are able to simulate realistic grey values in aRTist 2. Both of those approaches could potentially be a step forward to a full systematic approach for a digital twin of a real CT system in aRTist 2.
Relation of craze to crack length during slow crack growth phenomena in high‐density polyethylene
(2024)
The craze‐crack mechanism occurring in high‐density polyethylene (HDPE) causing slow crack growth and environmental stress cracking is investigated in detail with respect to the relation of crack length and the related craze zone. This is essential for the understanding of the resulting features of the formed fracture surface and their interpretation in the context of the transition from crack propagation to ductile shear deformation. It turns out that an already formed craze zone does not inevitably result in formation of a propagating crack, but could also undergo ductile failure. For the examination, the full notch creep test (FNCT) was employed with a subsequent advanced fracture surface analysis that was performed using various imaging techniques: light microscopy, laser scanning microscopy, scanning electron microscopy, and X‐ray micro computed tomography scan. FNCT specimens were progressively damaged for increasing durations under standard test conditions applying Arkopal, the standard surfactant solution, and biodiesel as test media were used to analyze the stepwise growth of cracks and crazes. From considerations based on well‐established fracture mechanics approaches, a theoretical correlation between the length of the actual crack and the length of the preceding craze zone was established that could be evidenced and affirmed by FNCT fracture surface analysis. Moreover, the yield strength of a HDPE material exposed to a certain medium as detected by a classic tensile test was found to be the crucial value of true stress to induce the transition from crack propagation due to the craze‐crack mechanism to shear deformation during FNCT measurements.
Highlights
- Progress of crack formation in high‐density polyethylene is analyzed by different imaging techniques
- Determined growth rates depend on distinction between craze zone and crack
- The ratio of the present crack to the anteceding craze zone is validated theoretically
- The transition from crack propagation to ductile shear deformation is identified
- An already formed craze zone may still fail by ductile mechanisms
Confocal micro-X-ray fluorescence (micro-XRF) spectroscopy facilitates three-dimensional (3D) elemental imaging of heterogeneous samples in the micrometer range. Laboratory setups using X-ray tube excitation render the method accessible for diverse research fields but interpretation of results and quantification remain challenging. The attenuation of X-rays in composites depends on the photon energy as well as on the composition and density of the material. For confocal micro-XRF, attenuation severely impacts elemental distribution information, as the signal from deeper layers is distorted by superficial layers. Absorption correction and quantification of fluorescence measurements in heterogeneous composite samples have so far not been reported. Here, an absorption correction approach for confocal micro-XRF combining density information from microcomputed tomography (micro-CT) data with laboratory X-ray absorption spectroscopy (XAS) and synchrotron transmission measurements is presented. The energy dependency of the probing volume is considered during the correction. The methodology is demonstrated on a model composite sample consisting of a bovine tooth with a clinically used restoration material.
Die additive Fertigung von Metallen hat inzwischen einen Reifegrad erreicht, der einen Einsatz in vielen Industriezweigen ermöglicht oder in greifbare Nähe rückt. Die Vorteile liegen vor allem in der Möglichkeit der Fertigung komplexer Bauteile, die sich konventionell nicht oder nur sehr aufwändig produzieren lassen, sowie in der Fertigung von hochindividualisierten Bauteilen in kleinen Stückzahlen. Allerdings ist der additive Fertigungsprozess hoch komplex und fehleranfällig. Um eine insbesondere für sicherheitsrelevante Bauteile notwendige Qualitätskontrolle zu gewährleisten, ist aktuell aufwändige nachgelagerte ZfP der einzelnen Bauteile notwendig. Alternativen könnten die In-situ-Prozessüberwachung und -prüfung bieten, die aktuell aber noch keinen ausreichenden Entwicklungsstand erreicht haben. Industrielle Fertigungsanlagen bieten keine oder nur geringe Flexibilität und Zugänglichkeit, um umfangreiche Untersuchungen auf diesem Gebiet zu ermöglichen. Daher haben wir an der BAM ein System für den Prozess des selektiven Laserschmelzens (PBF-LB/M) entwickelt, genannt SAMMIE. Es bietet eine komplett offene Systemarchitektur mit voller Kontrolle über den Prozess und flexiblem Zugang zur Baukammer, z.B. optisch sowohl direkt als auch koaxial zum Fertigungslaser. In diesem Beitrag stellen wir das System vor und zeigen erste experimentelle Ergebnisse der In-situ-Überwachung und -prüfung: Thermografische Schmelzbadüberwachung, optische Tomografie und In-situ-Laserthermografie. SAMMIE ermöglicht uns grundlegende Untersuchungen, die helfen werden, die In-situ-Prozessüberwachung und -prüfung weiterzuentwickeln, neue Erkenntnisse über die additive Fertigung zu gewinnen und die Sicherheit und Zuverlässigkeit des Prozesses zu verbessern.
For a deep process understanding of the laser powder bed fusion process (PBF-LB/M), recording of the occurring surface temperatures is of utmost interest and would help to pave the way for reliable process monitoring and quality assurance. A notable number of approaches for in-process monitoring of the PBF-LB/M process focus on the monitoring of thermal process signatures. However, due to the elaborate calibration effort and the lack of knowledge about the occurring spectral directional emissivity, only a few approaches attempt to measure real temperatures. In this study, to gain initial insights into occurring in the PBF-LB/M process, measurements on PBF-LB/M specimens and metal powder specimens were performed for higher temperatures up to T = 1290 °C by means of the emissivity measurement apparatus (EMMA) of the Center for Applied Energy Research (CAE, Wuerzburg, Germany). Also, measurements at ambient temperatures were performed with a suitable measurement setup. Two different materials—stainless steel 316L and aluminum AlSi10Mg—were examined. The investigated wavelength λ ranges from the visible range (λ-VIS = 0.40–0.75 µm) up to the infrared, λ = 20 µm. The influence of the following factors were investigated: azimuth angle φ, specimen temperature TS, surface texture as for PBF-LB/M surfaces with different scan angles α, and powder surfaces with different layer thicknesses t.
For a deep process understanding of the laser powder bed fusion process (PBF-LB/M), recording of the occurring surface temperatures is of utmost interest and would help to pave the way for reliable process monitoring and quality assurance. A notable number of approaches for in-process monitoring of the PBF-LB/M process focus on the monitoring of thermal process signatures. However, due to the elaborate calibration effort and the lack of knowledge about the occurring spectral directional emissivity, only a few approaches attempt to measure real temperatures. In this study, to gain initial insights into occurring in the PBF-LB/M process, measurements on PBF-LB/M specimens and metal powder specimens were performed for higher temperatures up to T = 1290 °C by means of the emissivity measurement apparatus (EMMA) of the Center for Applied Energy Research (CAE, Wuerzburg, Germany). Also, measurements at ambient temperatures were performed with a suitable measurement setup. Two different materials—stainless steel 316L and aluminum AlSi10Mg—were examined. The investigated wavelength λ ranges from the visible range (λ-VIS= 0.40–0.75 µm) up to the infrared, λ = 20 µm. The influence of the following factors were investigated: azimuth angle φ, specimen temperature TS, surface texture as for PBF-LB/M surfaces with different scan angles α, and powder surfaces with different layer thicknesses t.
This paper explores combining a gimbal-mounted tunable diode laser absorption spectroscopy (TDLAS) sensor and a video camera to create a virtual gas camera for methane leak detection. This provides a low-to-zero-cost extension of typical TDLAS gas tomography systems. A prototype setup mounted on a ground robot is evaluated. Results acquired using a simulated methane leak show the feasibility of the virtual gas camera, accurately detecting methane leaks by overlaying concentrations onto a visual image. While the acquisition time is significantly longer than for traditional gas cameras, potential enhancements are discussed. The study concludes that the virtual gas camera is feasible and useful, despite its longer acquisition time. It serves as a valuable software-only addition to typical TDLAS gas tomography systems, offering quickly-available on-site data augmentation for visual leak assessment at low-to-zero cost.
This paper outlines significant advancements in our previously developed aerial gas tomography system, now optimized to reconstruct 2D tomographic slices of gas plumes with enhanced precision in outdoor environments. The core of our system is an aerial robot equipped with a custom-built 3-axis aerial gimbal, a Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensor for CH4 measurements, a laser rangefinder, and a wide-angle camera, combined with a state-of-the-art gas tomography algorithm. In real-world experiments, we sent the aerial robot along gate-shaped flight patterns over a semi-controlled environment with a static-like gas plume, providing a welldefined ground truth for system evaluation. The reconstructed cross-sectional 2D images closely matched the known ground truth concentration, confirming the system’s high accuracy and reliability. The demonstrated system’s capabilities open doors for potential applications in environmental monitoring and industrial safety, though further testing is planned to ascertain the system’s operational boundaries fully.
Early detection of fatigue cracks and accurate measurements of the crack growth play an important role in the maintenance and repair strategies of steel structures exposed to cyclic loads during their service life. Observation of welded connections is especially of high relevance due to their higher susceptibility to fatigue damage. The aim of this contribution was to monitor fatigue crack growth in thick welded specimens during fatigue tests as holistically as possible, by implementing multiple NDT methods simultaneously in order to record the crack initiation and propagation until the final fracture. In addition to well-known methods such as strain gauges, thermography, and ultrasound, the crack luminescence method developed at the Bundesanstalt für Materialforschung und -prüfung (BAM), which makes cracks on the surface particularly visible, was also used. For data acquisition, a first data fusion concept was developed and applied in order to synchronize the data of the different methods and to evaluate them to a large extent automatically. The resulting database can ultimately also be used to access, view, and analyze the experimental data for various NDT methods. During the conducted fatigue tests, the simultaneous measurements of the same cracking process enabled a comprehensive comparison of the methods, highlighting their individual strengths and limitations. More importantly, they showed how a synergetic combination of different NDT methods can be beneficial for implementation in large-scale fatigue testing but also in monitoring and inspection programs of in-service structures - such as the support structures of offshore wind turbines.
Es wird eine Studie zur Charakterisierung eines anisotropen Stahls vorgestellt, bei der Ultraschalluntersuchungen mit Mikrostrukturanalysen verbunden werden. Das Material weist hohe Festigkeit und Korrosionsbeständigkeit auf, zugleich ist mit anisotropen Eigenschaften die mechanischen und betrieblichen Eigenschaften beeinflussen zu rechnen. Vorläufige Ergebnisse lassen vermuten, dass weitere Untersuchungen notwendig sind, um die Fähigkeiten und Grenzen des Materials genau zu bestimmen. Es wird ein systematischer Ansatz mit Array- Prüfköpfen, Time-of-Flight Diffraction (TOFD) Technik und mikrostrukturellen Untersuchungen angewendet, um die Wechselwirkung zwischen Anisotropie und Mikrostruktur des Stahls zu analysieren. Ultraschallprüfungen mit der TOFD-Technik und in Tauchtechnik liefern Einblicke in das anisotrope Verhalten des Werkstoffes, einschließlich entsprechenden Kornorientierung, Dämpfung und Schallgeschwindigkeitsvariation. Diese Messungen führen in Verbindung mit mikrostrukturellen Analysen zu einem tieferen Verständnis des Materialverhaltens. Unser Hauptziel ist es, ein Framework zu erstellen, welches die Ultraschallantwort anisotroper Materialien mit ihren mikroskopischen Struktureigenschaften verbindet. Die vorgestellte Methodik ermöglicht eine zerstörungsfreie und zügige Bewertung der Materialintegrität, was besonders bei der Anwendung von Hochleistungsmaterialien relevant ist. Durch diesen integrativen Ansatz werden verschiedener Charakterisierungsmethoden kombiniert, um ein umfassenderes Materialverständnis zu erreichen.
This study explores the acceleration of material design in the concrete industry, focusing on improving carbonation resistance, a key factor in the durability of concrete structures. Traditional tests for carbonation resistance are lengthy, but with the construction industry aiming for sustainable production, finding a balance between carbonation resistance and CO2 footprint is crucial. Our research employs two innovative methods: 1. Applying the Sequential Learning App for Materials Discovery (SLAMD), an AI materials design framework, to an extensive dataset of real-world concrete compositions to selectively test materials that meet market demands: maximum durability, optimal eco-durability, and the best cost-durability trade-off. 2. Investigating 1H Nuclear Magnetic Resonance (NMR) relaxometry as a quick alternative for characterizing carbonation behavior, as it saves time compared to traditional tests and assesses the complete material's pore space. Specific NMR features are then integrated into the material design model, with the model's performance compared against traditional approaches. The results of our study are compelling, demonstrating that materials can be precisely tailored to meet specific requirements with minimal data points. This marks a significant stride in the concrete industry, indicating that NMR-based, low-fidelity surrogate characterizations, combined with a focused, data-driven design approach, can substantially accelerate the development of durable, sustainable concrete mixtures.
The stress-induced tetragonal to monoclinic (t-m) zirconia phase transformation can provide a certain degree of plasticity to Ceria-stabilized (Ce-TZP) zirconia-based composites. Characterizing and monitoring this phase transition on a millimeter-size range, within the bulk and in-situ remains a challenge. In this work, the mechanical behavior of Ce-TZP based composite was studied in tension, combining microscopy and synchrotron Xray refraction techniques. In contrast with microscopy methods, which only provide surface information, X-ray refraction radiography (SXRR) allowed the visualization of all the transformation bands, over the entire length and thickness of tested specimens, opening up new avenues for in-situ stress-induced t-m transformation studies.
Adhesively bonded composite joints can develop voids and porosity during fabrication, leading to stress concentration and a reduced load-carrying capacity. Hence, adhesive porosity analysis during the fabrication is crucial to ensure the required quality and reliability. Ultrasonic-guided wave (UGW)-based techniques without advanced signal processing often provide low-resolution imaging and can be ineffective for detecting small-size defects. This article proposes a damage imaging process for adhesive porosity analysis of bonded composite plates using UGWs measured by scanning laser Doppler vibrometer (LDV). To implement this approach, a piezoelectric transducer is mounted on the composite joint specimen to generate UGWs, which are measured over a densely sampled area. The signals obtained from the scan are processed using the proposed signal processing in different domains. Through the utilization of filter banks in frequency and wavenumber domains, along with the root-mean-square calculation of filtered signals, damage images of the adhesive region are obtained. It has been observed that different filters provide information related to different void sizes. Combining all the images reconstructed by filters, a final image is obtained which contains damages of various sizes. The images obtained by the proposed method are verified by radiography results and the porosity analysis is presented. The results indicate that the proposed methodology can detect the pores with the smallest detectable pore area of 2.41 mm^2, corresponding to a radius of 0.88 mm, with an overall tendency to overestimate the pore size by an average of 11%.
This study investigates the room‐ and high‐temperature (650 °C) tensile and low‐cycle‐fatigue behavior of Inconel 718 produced by laser powder bed fusion (PBF‐LB/M) with a four‐step heat treatment and compares the results to the conventional wrought material. The microstructure after heat treatment is characterized on different length scales. Compared to the wrought variant, the elastic and yield properties are comparable at both test temperatures while tensile strength, ductility, and strain hardening capacity are lower. The fatigue life of the PBF‐LB/M variant at room temperature is slightly lower than that of the wrought material, while at 650 °C, it is vice versa. The cyclic stress response for both material variants is characterized by cyclic softening, which is more pronounced at the higher test temperature. High strain amplitudes (≥0.7%) at room temperature and especially a high testing temperature result in the formation of multiple secondary cracks at the transitions of regions comprising predominantly elongated grain morphology and columns of stacked grains with ripple patterns in the PBF‐LB/M material. This observation and pronounced crack branching and deflection indicate that the cracks are controlled by sharp micromechanical gradients and local crystallite clusters.
In this presentation, the results of the determination of the diffraction and single-crystal elastic constants of laser powder bed fused Inconel 718 are presented. The analysis is based on high-energy synchrotron diffraction experiments performed at the Deutsches Elektronen-Synchrotron. It is shown that the characteristic microstructure of laser powder bed fused Inconel 718 impacts the elastic anisotropy and therefore the diffraction and single-crystal elastic constants. Finally, the consequences on the diffraction-based residual stress determination of laser powder bed fused Inconel 718 are discussed.
Ziel des FuE-Vorhabens ist die Entwicklung, Aufbau und Validierung eines gasto-mographischen Messsystems basierend auf stationärer und mobiler Sensorik zum Emissionsmonitoring in kommunalen Kläranlagen. Die Gastomographie basiert hierbei im Wesentlichen auf, aus unterschiedlichen Sichtwinkeln aufgenommenen, integralen Konzentrationsmessungen, anhand derer eine Rekonstruktion der Gasverteilung erfolgt. Das FuE-Projekt kombiniert hierfür stationäre Sensornetzwerke mit luftgestützten und bodengebundenen Robotersystemen in einem System. Letztere werden mit Reflektoren und/oder Gasdetektoren ausgestattet. Hierfür werden Open-Path-Gasmesstechnik basierend auf Tunable Diode Laser Ab-sorption Spectroscopy (TDLAS, primär CH4 in ppm·m) und In-situ-Gassensorik (CH4, ppm) auf Basis von z.B. Infrarot eingesetzt. Dies sind zwei komplementäre Methoden der Gasmessung: Die In-situ-Gassensorik ermöglicht Punktmessungen, wohingegen TDLAS-Sensoren Gaskonzentrationen integral über offene Messstre-cken von bis zu 60 m gegen Oberflächen messen. Die In-situ-Gassensorik wird für Referenzmessungen und ggf. zur Erhöhung der Rekonstruktionsqualität zum Ein-satz kommen. Die wesentlichen Neuheiten des Projekts sind:
• 2D-Gastomographie auf Basis eines mit TDLAS-basierter Open-Path-Gasmesstechnik und Reflektoren ausgestatteten heterogenen Messsystems.
• CT-basierte Rekonstruktionsalgorithmen, adaptiert an die komplexen Rahmenbedingungen.
• Validierung des Messsystems anhand realer Messungen auf Kläranlagen.
Automated Wall Thickness Evaluation for Turbine Blades Using Robot-Guided Ultrasonic Array Imaging
(2024)
Nondestructive testing has become an essential part of the maintenance of modern gas turbine blades and vanes since it provides an increase in both safety against critical failure and efficiency of operation. Targeted repairs of the blade’s airfoil require localized wall thickness information. This information, however, is hard to obtain by nondestructive testing due to the complex shapes of surfaces, cavities, and material characteristics. To address this problem, we introduce an automated nondestructive testing system that scans the part using an immersed ultrasonic array probe guided by a robot arm. For imaging, we adopt a two-step, surface-adaptive Total Focusing Method (TFM) approach.
For each test position, the TFM allows us to identify the outer surface, followed by calculating an adaptive image of the interior of the part, where the inner surface’s position and shape are obtained. To handle the large volumes of data, the surface features are automatically extracted from the TFM images using specialized image processing algorithms. Subsequently, the collection of 2D extracted surface data is merged and smoothed in 3D space to form the outer and inner surfaces, facilitating wall thickness evaluation. With this approach, representative zones on two gas turbine vanes were tested, and the reconstructed wall thickness values were evaluated via comparison with reference data from an optical scan. For the test zones on two turbine vanes, average errors ranging from 0.05 mm to 0.1 mm were identified, with a standard deviation of 0.06–0.16 mm.