Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Dokumenttyp
Sprache
- Englisch (3)
Referierte Publikation
- ja (3) (entfernen)
Schlagworte
- CAFTP (2)
- Explosion limits (2)
- Acetone (1)
- Adiabatic Flame Temperatures (1)
- Alcohols (1)
- Classification (1)
- Elevated temperatures (1)
- Explosion protection (1)
- Flammability (1)
- Flammable Gas (1)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (3) (entfernen)
In this study, experimental determination and modelling investigations for the explosion regions of 1,3-dioxolane/inert gas/N2O and 1,3-dioxolane/inert gas/air mixtures were carried out and compared. The experimental measurements were carried out at 338 K and atmospheric pressure according to EN1839 method T using the inert gases N2, CO2, He and Ar. The results showed that the ratio of the lower explosion limit in N2O (LELN2O) to the lower explosion limit in air (LELair) is 0.52 and the ratio of the maximum oxygen content in air (MOCair) to the limiting oxidizer fraction in nitrous oxide (LOFN2O) is 0.36 ± 0.02 independent of the inert gas. When comparing the inert gas amount at the apex based on the pure oxidizing component, which is O2 in case of air, N2O-containing mixtures need less inert gas to reach the limiting oxidizer quantity whereas the efficiency of inert gases is in the same order. The coefficients of nitrogen equivalency however were found to differ to some extent. The explosion regions of 1,3-dioxolane/inert gas/oxidizer mixtures were modelled using the calculated adiabatic flame temperature profile (CAFTP) method as well as corrected adiabatic flame temperatures. The results indicate good agreement with experimental data for CO2, N2 and Ar- containing mixtures. The noticeable deviations that occur when He is the inert gas are due to the lacking transport data of that mixture.
The explosion regions of 1-propanol, 2-propanol, acetone and 1-butanol in air were measured in the presence of CO2, He, N2 and Ar in accordance with EN1839 method T at high temperatures and at atmospheric pressure. The experimental results show that 1-propanol, 2-propanol and acetone have very similar lower explosion limits (LELs). 1-Butanol shows a slightly wider explosion area near the LEL line. In addition, the explosion regions of all combustible/inert gas/air mixtures were calculated with the method of constant adiabatic flame temperature profiles (CAFTP), using the flame temperature profile along the explosion region boundary curve of each combustible/N2/air mixture as a reference to determine the explosion regions of combustible/inert gas/air mixtures with inert gases other than N2 at different initial temperatures. To calculate the explosion regions for systems containing He, the calculation method was modified to include the very different physical transport properties of He. Moreover, the procedure for calculating the apexes in the ternary explosion diagrams was modified. The calculation results show good agreement with the experimental results.
The safety characteristics of flammable gases and liquids are required when identifying potentially explosive mixtures and taking appropriate actions concerning explosion protection. Examples are given here of the safe handling and evaluation of hazards during the processing, storage, transport, and disposal of flammable liquids and gases. The CHEMSAFE database is presented as a reliable source of safety characteristic data, and its new open-access version is introduced. CHEMSAFE currently contains assessed properties for about 3000 liquids, gases and mixtures. The lack of a broad experimental foundation in the extensive field of non-atmospheric conditions shows the need for further investigation and standardization. This article summarizes experimental evidence and estimation methods for safety characteristic data under non-atmospheric conditions pointing out current limitations. Suggestions for pre-normative research on safety data under non-atmospheric conditions are given.