Pressurisation of full-containment pressure vessels in fire is known to be driven by thermal stratification. The predominant mode of heat transfer to the contents (convection from the shell to the liquid phase) results in formation of „hot“ boundary layers. Sub-cooled boiling may also be present. The warm layer rises to the surface through buoyancy and bubble flow, increasing the surface of the liquid above that of the bulk temperature, and hence driving a pressure rise.
For reliable prediction of the complex effects governing vessel pressurization a three-dimensional numerical model is required. Work is being undertaken on such a model by other institutions in cooperation with this project.
The arrangement of the measuring sensors allowed the
capture of air flow induced temperatures and material
temperatures on various points of the cylinder body. Four
significant temperature levels could be observed: Inside the cylinder (far from the wall, close to the wall), inside the aluminium liner and outer surface. Figure 5 shows the temperature distribution after a regular filling process with a filling time of ten minutes. The temperature sensors T1 - T9 are marked with different colors. The corresponding measurement points are shown in Figure 4. Due to the high thermal conductivity of the aluminum liner the induced temperature peaks are quickly derived. A flow-induced exceeding of the maximum approval temperature is not expected. Regarding the safety assessement the results show that the pressure and temperature profilesmustbe taken into account.
A new tank design for Hazmat
(2016)
Initial studies have shown pre-deformed honeycomb structure
pressure vessels to have comparable burst pressure to straight steel vessels.
It was shown that honeycomp structured tanks have a higher energy absorption than straight steel tanks.
Future studies will investigate optimization of the deformed plate, to determine if increased payloads or a reduced wall thickness can be achieved.