Ultrashort laser pulse micromachining features a high precision. By increasing the repetition rate of the applied laser to several 100 kHz, laser processing becomes quick and cost-effective and make this method attractive for industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose becomes significant for high-repetition-rate laser systems so that radiation safety must be considered.
Ultrashort pulse laser micromachining at repetition rates of several hundreds of kHz allows a cost-effective high precision manufacturing, which makes this method attractive for many industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per laser pulse is low, for currently available high-repetition-rate laser systems the accumulated X-ray dose becomes significant and radiation safety must be considered. Influences of the processing parameters are discussed and radiation protection aspects will be outlined
The use of ultrashort laser pulses for material processing in air has many advantages. Due to the progressive development in the laser sector, average powers in the kW range with pulse repetition rates exceeding the MHz-level are available. The machining with high-intensity laser pulses can be accompanied by the generation of a near-surface electron plasma due to absorption and ionization of the material, a subsequent plasma heating by the laser pulse, and finally an interaction of “hot” plasma electrons with the workpiece leading to continuous and characteristic X-ray radiation. The amount of this unwanted X-ray radiation is determined by the laser parameters (pulse duration, intensity, wavelength, polarization), the workpiece (atomic number, surface preparation), and the laser process management (scanning or stationary regime, laser turning). The use of laser intensities above 10^13 W/cm^2 in combination with laser pulse repetition rates in the few 100 kHz-range can lead to X-ray dose rates exceeding the permitted X-ray limits for members of the public. Especially the materials tungsten and steel show significant X-ray emission. Recently, the current state of the art in the field of undesired generation of X-ray radiation during ultrashort pulse laser processing in air was reviewed. In this presentation, important aspects of the measured X-ray doses, X-ray spectra, and practical issues of radiation protection are discussed.
Ultrashort laser pulses have found their way into industrial material processing. They take advantage of the fact that moderate laser fluences can produce high quality material removal without significant thermal influence. The growing availability of powerful, highly repeating laser sources and an advanced laser beam control have favored these developments. However, the laser-matter interaction can be accompanied by the production of X-rays. Small doses per laser pulse can accumulate to significant dose rates at high laser pulse repetition rates which may exceed the permitted X-ray limits for human exposure. Consequently, a proper radiation shielding must be considered in laser material processing. The paper summarizes the current state of the art in the field of undesired generation of X-ray radiation during ultrashort pulse laser material processing in air.
The industrial use of ultrashort laser pulses has made considerable progress in recent years. The reasons for this lie in the availability of high average powers at pulse repetition rates in the several 100 kHz range. The advantages of using ultrashort laser pulses in terms of processing precision can thus be fully exploited. However, high laser intensities on the workpiece can also lead to the generation of unwanted X-rays. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose can become significant for high-repetition-rate laser systems so that X-ray exposure safety limits must be considered. The X-ray emission during ultrashort pulse laser processing was investigated for a pulse duration of 925 fs at 1030 nm wavelength and 400 kHz repetition rate. Industrially relevant materials such as steel, aluminum and glass were treated. Tungsten served as reference. X-ray spectra were recorded, and X-ray dose measurements were performed for laser treatment in air. For laser intensities > 2 × 10^13 W/cm2, X-ray doses exceeding the regulatory exposure limits for members of the public were found. Suitable X-ray protection strategies are proposed.
Ultrashort laser pulse micromachining features a high precision. By increasing the repetition rate of the applied laser to several 100 kHz, laser processing becomes quick and cost-effective and make this method attractive for industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose becomes significant for high-repetition-rate laser systems so that radiation safety must be considered. The X-ray emission during ultrashort laser processing was investigated for an intensity range up to 2.6*10^14 W/cm2. The investigations were performed with a laser emitting pulses with 925 fs pulse duration, at 1030 nm wavelength and 400 kHz repetition rate. Steel, tungsten, and glass were studied in ambient air. Corresponding X-ray spectra and X-ray dose measurements were presented. Suitable radiation protection strategies were shown.
Ultrashort pulse laser materials processing can be accompanied by the production of X-rays. Small doses per laser pulse can accumulate to significant dose rates at high laser pulse repetition rates which may exceed the permitted X-ray limits for human exposure. Consequently, a proper radiation shielding must be considered in laser machining. A brief overview of the current state of the art in the field of undesired generation of X-ray radiation during ultrashort pulse laser material processing in air is presented.
Ultrashort laser pulse micromachining features a high precision. By increasing the repetition rate of the applied laser to several 100 kHz, laser processing becomes quick and cost-effective and make this method attractive for industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose becomes significant for high-repetition-rate laser systems so that radiation safety must be considered.
This dataset contains the processed and analysed small-angle X-ray scattering data associated with all samples from the publications "Bio-SAXS of Single-Stranded DNA-Binding Proteins: Radiation Protection by the Compatible Solute Ectoine" (https://doi.org/10.1039/D2CP05053F).
Files associated with McSAS3 analyses are included, alongside the relevant SAXS data, with datasets labelled in accordance to the protein (G5P), its concentration (1, 2 or 4 mg/mL), and if Ectoine is present (Ect) or absent (Pure). PEPSIsaxs simulations of the GVP monomer (PDB structure: 1GV5 ) and dimer are also included.
TOPAS-bioSAXS-dosimetry extension for TOPAS-nBio based particle scattering simulations can be obtained from https://github.com/MarcBHahn/TOPAS-bioSAXS-dosimetry which is further described in https://doi.org/10.26272/opus4-55751.
This work was funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under grant number 442240902 (HA 8528/2-1 and SE 2999/2-1). We acknowledge Diamond Light Source for time on Beamline B21 under Proposal SM29806. This work has been supported by iNEXT-Discovery, grant number 871037, funded by the Horizon 2020 program of the European Commission.