We present the results of distributed fiber optic strain sensing for condition monitoring of a hybrid type IV composite fully wrapped pressure vessel using multilayer integrated optical fibers. Distributed strain sensing was performed for a total number of 252,000 load cycles until burst of the vessel. During this ageing test material fatigue could be monitored and spatially localized. Critical material changes were detected 17,000 cycles before material failure. Results have been validated by acoustic emission analysis.
Due to their high strength-to-weight ratio and excellent fatigue resistance, glass fiber reinforced polymers (GFRP) are used as a construction material in a variety of applications including composite high-pressure gas storage vessels. Thus, an early damage detection of the composite material is of great importance. Material degradation can be determined via measuring the distributed strain profile of the GFRP structures. In this article, swept wavelength interferometry based distributed strain sensing (DSS) was applied for structural health monitoring of internal pressure loaded GFRP tube specimens. Measured strain profiles were compared to theoretical calculation considering Classical Lamination Theory. Reliable strain measurements with millimeter resolution were executed even at elongations of up to 3% in the radial direction caused by high internal pressure load. Material fatigue was localized by damaged-induced strain changes during operation, and detected already at 40% of burst pressure.
Due to high specific stiffness, fibre reinforced plastics are the dominant material group for the design of mobile pressure vessels. At the Federal Institute of Materials Research and Testing (BAM) aging process of composite pressure vessels is studied to be able to give more accurate lifetime predictions in future. Investigations are based on type III breathing air cylinders consisting of an aluminium tank which is fully wrapped with carbon fibre reinforced plastics. Goal is to detect changes of residual stresses over life time which directly affect fatigue strength. Within this paper an approach is presented to monitor residual stresses via an experimental modal analysis (EMA). First, the influence of changed stress conditions on modal parameters is analysed via a numerical study. Secondly, a test bench for an EMA is set up. To be able to analyse cylinders of different prestress condition, several specimens are prestress modified via high-temperature and high-pressure treatment. During modification processes, specimens are monitored via optical fibres to control prestress modifications. Through experimental measurements of the modified specimens via EMA changes in prestressing can be detected. Finally, validity and accuracy of the EMA is evaluated critically by comparing all numerically and experimentally obtained data.
We have shown that for C-ODTR based DAS two UV-inscribed scattering segments within an optical fiber have a significant influence on the local sensitivity Fading characteristics. This method was experimental proven to be suitable for distributed dynamic strain measurement in a thermally unstable environment. Signal-to-noise ratio analyses for detecting a signal peak within the time-dependent spectra were performed. Results show an increase in SNR and additionally that the occurrence of total loss of sensitivity (SNR <1) could be decreased by a factor of six when compared to an untreated standard fiber. We have shown that for C-ODTR based DAS two UV-inscribed scattering segments within an optical fiber have a significant influence on the local sensitivity Fading characteristics. This method was experimental proven to be suitable for distributed dynamic strain measurement in a thermally unstable environment. Signal-to-noise ratio analyses for detecting a signal peak within the time-dependent spectra were performed. Results show an increase in SNR and additionally that the occurrence of total loss of sensitivity (SNR <1) could be decreased by a factor of six when compared to an untreated standard fiber.