In this study, experimental determination and modelling investigations for the explosion regions of 1,3-dioxolane/inert gas/N2O and 1,3-dioxolane/inert gas/air mixtures were carried out and compared. The experimental measurements were carried out at 338 K and atmospheric pressure according to EN1839 method T using the inert gases N2, CO2, He and Ar. The results showed that the ratio of the lower explosion limit in N2O (LELN2O) to the lower explosion limit in air (LELair) is 0.52 and the ratio of the maximum oxygen content in air (MOCair) to the limiting oxidizer fraction in nitrous oxide (LOFN2O) is 0.36 ± 0.02 independent of the inert gas. When comparing the inert gas amount at the apex based on the pure oxidizing component, which is O2 in case of air, N2O-containing mixtures need less inert gas to reach the limiting oxidizer quantity whereas the efficiency of inert gases is in the same order. The coefficients of nitrogen equivalency however were found to differ to some extent. The explosion regions of 1,3-dioxolane/inert gas/oxidizer mixtures were modelled using the calculated adiabatic flame temperature profile (CAFTP) method as well as corrected adiabatic flame temperatures. The results indicate good agreement with experimental data for CO2, N2 and Ar- containing mixtures. The noticeable deviations that occur when He is the inert gas are due to the lacking transport data of that mixture.
Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn:
1. There is a need for improvement and validation for all laboratory test methods examined.
2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification.
This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality.
CEQAT-DGHS Interlaboratory Test Programme for Chemical Safety - Need of Test Methods Validation
(2019)
Safety experts, manufacturers, suppliers, importers, employers or consumers must be able to rely on the validity of safety-related test methods and on correct test results and assessments in the laboratory. Via the eChemPortal lots of data from the REACH registration dossiers are available. However, the quality and correctness of the information remains in the responsibility of the data submitter. Unfortunately, we found more or less appropriate information on physicochemical properties and concluded that more quality or adequacy of any data submitted will be needed.
Interlaboratory tests play a decisive role in assessing the reliability of test results. Interlaboratory tests on different test methods have been performed by Bundesanstalt für Materialforschung und –prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB) in collaboration with the QuoData GmbH during the last 10 years. Significant differences between the results of the participating laboratories were observed in all interlaboratory tests. The deviations of the test results were not caused only by laboratory faults but also by deficiencies of the test method.
In view of the interlaboratory test results the following conclusions can be drawn:
• To avoid any discrepancy on classification and labelling of chemicals it should become state of the art to use validated test methods and the results accompanied by the measurement uncertainty.
• A need for improvement is demonstrated for all examined test methods. Thus, interlaboratory tests shall initially aim at the development, improvement and validation of the test methods and not on proficiency tests.
• The laboratory management and the practical execution of the tests need to be improved in many laboratories.
• The term "experience of the examiner" must be seen critically: A "long experience with many tests" is not necessarily a guarantee for correct results.
In this joint project, standardized measurement methods for hybrid
mixtures are developed, which serve to determine safety
characteristics for explosion protection.
A hybrid mixture is a multi-phase System consisting of fuel gas or
vapor, as well as air and flammable dust. This combination can occur
for instance in drying processes or during heterogenous reaction
processes.
The safety characteristics of flammable gases and liquids are required when identifying potentially explosive mixtures and taking appropriate actions concerning explosion protection. Examples are given here of the safe handling and evaluation of hazards during the processing, storage, transport, and disposal of flammable liquids and gases. The CHEMSAFE database is presented as a reliable source of safety characteristic data, and its new open-access version is introduced. CHEMSAFE currently contains assessed properties for about 3000 liquids, gases and mixtures. The lack of a broad experimental foundation in the extensive field of non-atmospheric conditions shows the need for further investigation and standardization. This article summarizes experimental evidence and estimation methods for safety characteristic data under non-atmospheric conditions pointing out current limitations. Suggestions for pre-normative research on safety data under non-atmospheric conditions are given.
The safety characteristics of flammable gases and liquids are required when identifying potentially explosive mixtures and taking appropriate actions concerning explosion protection. Examples are given in this review of the safe handling and evaluation of hazards during the processing, storage, transport, and disposal of flammable liquids and gases. The CHEMSAFE database is presented as a reliable source of safety characteristic data, and ist new open-access version is introduced. CHEMSAFE currently contains assessed properties for about 3000 flammable liquids, gases and mixtures. The lack of a broad experimental foundation in the extensive field of non-atmospheric conditions shows the need for further investigation and standardization. This review summarizes experimental evidence and estimation methods for safety characteristic data under non-atmospheric conditions pointing out current limitations. Suggestions for pre-normative research on safety data under nonatmospheric conditions are given.
The safety characteristics of flammable gases and liquids are required when identifying potentially explosive mixtures and taking appropriate actions concerning explosion protection. Examples are given in this review of the safe handling and evaluation of hazards during the processing, storage, transport, and disposal of flammable liquids and gases. The CHEMSAFE database is presented as a reliable source of safety characteristic data, and ist new open-access version is introduced. CHEMSAFE currently contains assessed properties for about 3000 flammable liquids, gases and mixtures. The lack of a broad experimental foundation in the extensive field of non-atmospheric conditions shows the need for further investigation and standardization. This review summarizes experimental evidence and estimation methods for safety characteristic data under non-atmospheric conditions pointing out current limitations. Suggestions for pre-normative research on safety data under nonatmospheric conditions are given.