Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Dokumenttyp
- Zeitschriftenartikel (3)
- Beitrag zu einem Tagungsband (1)
- Sonstiges (1)
- Posterpräsentation (1)
Schlagworte
- Emission test chamber (3)
- Indoor air (2)
- Quality assurance (2)
- Quality control (2)
- Biozidanalytik (1)
- Degradation (1)
- Emissionsmesskammer (1)
- Photocatalysis (1)
- Schwerflüchtige organische Verbindungen (1)
- VOC (1)
Photocatalysis is a promising technique to reduce volatile organic compounds indoors. Titanium dioxide (TiO2) is a frequently-used UV active photocatalyst. Because of the lack of UV light indoors, TiO2 has to be modified to get its working range shifted into the visible light spectrum. In this study, the photocatalytic degradation of toluene, butyl acetate and limonene was investigated under UV LED light and blue LED light in emission test chambers with catalysts either made of pure TiO2 or TiO2 modified with graphene oxide (GO). TiO2 coated with different GO amounts (0.75%–14%) were investigated to find an optimum ratio for the photocatalytic degradation of VOC in real indoor air concentrations. Most experiments were performed at a relative humidity of 0% in 20 L emission test chambers. Experiments at 40% relative humidity were done in a 1 m³ emission test chamber to determine potential byproducts. Degradation under UV LED light could be achieved for all three compounds with almost all tested catalyst samples up to more than 95%. Limonene had the highest degradation of the three selected volatile organic compounds under blue LED light with all investigated catalyst samples.
Volatile organic compounds (VOC) are ubiquitous in the indoor air, since they emit from materials used indoors. Investigations of these materials are mostly carried out in test chambers under controlled climatic conditions. Quality control of these test chamber measurements is important but there is a lack of commercially available homogenous reference materials. The approach of this study is to dope a supporting material with VOCs, which are then reproducibly released in measurable chamber air concentrations between 30 to 300 µg m ³. From several tested supporting materials vacuum grease (APIEZON M) was selected because of its very low own emissions. First tests were conducted with styrene. For the estimation of the initial emission and the emission over time FEM (finite element methods) modelling was used. Based on this, five samples with a surface of 7 cm2 and a thickness of 12 mm with a content of 1 ‰ styrene were investigated at (23 ± 2) °C and (50 ± 5) % relative humidity in the µ-chamber (3 samples) and 24 L test chambers (2 samples) for 28 days. Air samples were taken after 24 hours, 3, 7, 14, 21 and 28 days on Tenax TA® sorption tubes and analyzed by TD-GC-MS. The area specific emission rate (SERa) was calculated to compare the results from both chamber types. After 24 hours SERa was between 0.8 0.9 µg cm 2 h 1 (3800 4000 µg m 3) for the µ-chamber samples and between 0.9 1.1 µg cm 2 h 1 (300-370 µg m 3) for the 24 L test chamber samples. After 28 days the SERa was at 0.2 µg cm 2 h 1 for all samples. The relative standard deviation of the SERa was between 1 26 %. These results show the applicability of vacuum grease as supporting material and the favored starting concentration range could be achieved in the 24 L test chambers.
Die meisten organischen Biozide gehören zu der Gruppe der schwerflüchtigen organischen Verbindungen (SVOC – semi volatile organic compounds). Zu den klassischen Bioziden zählen u.a. Lindan, Pentachlorphenol PCP) und Dichlordiphenyltrichlorethan (DDT) und zu den neueren u.a. Dichlofluanid, Tebuconazol und Permethrin. Biozide kamen in Museen vor allem in den 50er und 60er Jahren zum Schutz der Exponate zum Einsatz,1 wo sie hauptsächlich in Depoträumen zu finden sind, in welchen sie zum akuten und zum präventiven Schutz vor Schadorganismen eingesetzt wurden.2 Im Laufe der Zeit wurde jedoch festgestellt, dass sich der Einsatz von Bioziden negativ auf die menschliche Gesundheit auswirkt und auch zu Schäden an den behandelten Exponaten führen kann. 3 Verschiedene Möglichkeiten der Biozidanalytik und der Einfluss von Senkeneffekten auf die Analytik werden in diesem Beitrag vorgestellt.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Die Analytik von Phthalaten (DMP bis DEHP) in der Luft ist mit thermischer Desorption unter Verwendung von Quarzwolle als Adsorbens erfolgreich realisierbar. Dies wurde durch eine Methodenvalidierung bestätigt. Es wurden sowohl Messungen im Innenraum als auch in Emissionskammern vorgenommen. In den Emissionskammermessungen wurden mögliche Senkeneffekte der Kammeroberfläche (Glas) untersucht. Unter Zuhilfenahme der idealen Abklingkurve wird bestätigt, dass diese Oberfläche eine Senke darstellt.