Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Dokumenttyp
Schlagworte
- Emission test chamber (2)
- Acetic acid (1)
- Air sampling (1)
- Building products (1)
- Carbograph 5TD (1)
- Carbopack X (1)
- Construction product (1)
- DNPH (1)
- Emission testing (1)
- Formic acid (1)
Organisationseinheit der BAM
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well-characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 µg/m3. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 µg/m3. In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28 % in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51 %.
Besides measurement of VOC emissions also the evaluation of odour emissions and the perceived intensity of odours gains in importance. Due to difficulties detected in the measurement method of the perceived intensity described in (ISO 16000-28, 2012) the introduction of “reference” odours will be recommended for the training of panellists and as basis for interlaboratory comparisons.
In order to generate the “reference” odours standard liquid substances were directly injected into the main gas flow provided to the panellists. One of the substances tested was ethyl acetate. A pre-evaluation was conducted with six untrained panellists and has shown that ethyl acetate is potentially suitable as reference odour. For further validation of those “reference” odours they additionally will be provided to and evaluated by trained panellists of well established-measurement institutes.
Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed.
Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.
Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography mass spectrometry/mass spectrometry).
Die Analytik von Phthalaten (DMP bis DEHP) in der Luft ist mit thermischer Desorption unter Verwendung von Quarzwolle als Adsorbens erfolgreich realisierbar. Dies wurde durch eine Methodenvalidierung bestätigt. Es wurden sowohl Messungen im Innenraum als auch in Emissionskammern vorgenommen. In den Emissionskammermessungen wurden mögliche Senkeneffekte der Kammeroberfläche (Glas) untersucht. Unter Zuhilfenahme der idealen Abklingkurve wird bestätigt, dass diese Oberfläche eine Senke darstellt.