A further improvement of the excellent properties of UHPC can be realized with thermal Treatment. Like for normal concrete, it accelerates the hardening and prevents shrinkage after the treatment. Additionally, an increase in strength can be achieved. Aim of this study was the optimisation of the thermal Treatment conditions of UHPC for very different Treatment methods; heat Treatment at 90 °C for unprotected and sealed samples, hot water bath at 90 °C and hydrothermal Treatment at 185 °C/1.1 MPa. The pre-storage time and the dwell time were systematically varied for each method to gain a higher strength. The compressive strength depends on the manner of Treatment at which higher water accessibility leads to higher strengths. The Phase composition changes considerably with different Treatment tempereatures. Finally, it can activate unhydrated binder components forming additional C-S-H, leading to higher strength.
An experimental investigation was carried out to study the in-plane shear behaviour of rammed earth structural elements strengthened with polyester fabric strips. The original idea for the retrofitting with polyester fabric strips was to introduce a vertical element for walls in order to take up horizontal loads resulting in a shear response of the building element. It has to be considered that vertical slits into the walls for fixing the strips are points of weakness and have to be mitigated by the adhesive. In this case a base coat mortar was employed. Strengthened elements were tested to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. As part of the study results of a testing campaign of unstrengthened structural elements were considered. Strengthened elements were tested in diagonal compression/shear and cyclic shear-compression. A unique reinforcement orientation was used. The results of these tests are presented in this paper and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective under cyclic shear-compression tests, with increase in load and displacement capacity observed. Under diagonal compression the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips.
The life span of a building product is a key Parameter when it comes to Life Cycle Assessment (LCA) performance. Nevertheless, many uncertainties affect this parameter due to a lack of long-term performance data. The sensitivity of the LCA outcomes to this parameter has been studied within the framework of the FP7 project H-House (Healthier Life with Eco-innovative Components for Housing Constructions) funded by the European Commission.
The paper Features two comparative studies conducted within the scope of this project: one for new construction and another for renovation. An innovative precast sandwich panel made of Textile Reinforced Concrete (TRC) and Foamed Concrete (FC), used for external walls in new construction, is compared with a steel reinforced concrete (SRC) wall of the same thermal resistance. For renovation, a novel halfsandwich panel made of Ultra-High-Performance-Concrete (UHPC) and Autoclaved Aerated Concrete (AAC) is compared with cladding having the same thermal performance. The Evaluation was conducted using a multi-criteria basis according to the LCA methodology (ISO 14040- 44). In each case, an identical life span for both scenarios leads to the fact that H-House components have a better environmental performance. The ISO 15686 and ist relevant parts have been considered for the estimation of the service life span. The sensitivity analysis shows the link between the impact savings of the innovative walls and the life span of the walls and their components. In particular, it was found that since both scenarios need to fulfil the same service during an identical reference period, and since some maintenance and replacement of materials are necessary over time for standard Solutions compared to the innovative ones, the chosen life span of the components plays a role of utmost importance. The sensitivity analysis discloses the effect of the assumptions on these aspects.
This paper presents the development of ultra-high performance concrete (UHPC) for façade elements with self-cleaning properties. For creating self-cleaning surfaces two different approaches are proposed. One approach is based on the photocatalytic activation of the external UHPC shell by incorporation of TiO2 particles. The second approach consists of the modification of the UHPC surface by micro structuring in combination with the application of hydrophobic agents to create durable super hydrophobicity. In the framework of the H-HOUSE Project funded by the European Commission the experimental investigations were performed with UHPC based on Dyckerhoff Nanodur® technology. The special properties of this material enable the precise reproduction of any micro structure without flaws. The current results obtained from laboratory and outdoor weathering tests are promising and demonstrate the feasibility of the approaches.
The aim of this study was to develop a lightweight composite façade element for refurbishment of existing façades. It was crucial to minimize the thermal bridges and to undercut the thermal requirement of the system existing façade new element. The awareness of the environmental impact of the building sector is increasing. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimized use of building area due to thinner elements and minimized maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibers. In this framework, composite elements have been developed combining an autoclaved aerated concrete insulation layer with an external UHPC supporting layer. The results show that the lightweight composite element has a good performance in term of thermal transmittance and minimization of thermal bridges.
The main aim of the research was the development of a first valid database for material parameters of earth block masonry (EBM) with particular regard to statistical characteristics. A solid database is needed for the determination of the materials partial safety factor. Therefore, compressive strength tests were carried out with two types of earth blocks and two types of prefabricated earth mortar.
The evaluation has shown that the mean variation of the compressive strength was remarkably less than expected, which indicates high quality standards of the components earth block and mortar with regard to industrial production. Using the reliability method, a partial safety factor for EBM subjected to compression was determined on the basis of these test results. The findings have shown that a common calculation method for EBM based on partial safety factors following the valid masonry construction standard is feasible.