Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Dokumenttyp
- Vortrag (19)
- Zeitschriftenartikel (10)
- Beitrag zu einem Tagungsband (3)
- Sonstiges (1)
- Forschungsbericht (1)
Sprache
- Englisch (34) (entfernen)
Schlagworte
- Ellipsometry (5)
- Adhesive strength (4)
- Bonding strength (4)
- Centrifugal Adhesion Testing (CAT) (4)
- Spectroscopic Ellipsometry (3)
- Thin films (3)
- Doped tin oxide (2)
- Gas monitoring (2)
- Gas sensing (2)
- Methodology in metrology (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (19)
The paper addresses the “Functional coatings for mechanical applications: characterization and standardization” and the following points are discussed in more detail:
1. Mechanic alapplications (coatings for tools and components, system features vs. material parameters)
2. Mechanical characterization (instrumented indentation testing (IIT), centrifugal adhesion testing (CAT), state of standardization)
3. Topometric characterization (white light interference microscopy (WLIM, 3D), mechanical stylus (MS, 2D), state of standardization)
4. Optical characterization (spectroscopic ellipsometry (SE), inter-laboratory comparison, state of standardization)
Proposal for revision of en 15870 „Adhesives determination of tensile strength of butt joints”
(2021)
The paper addresses the PROPOSAL FOR REVISION OF EN 15870
„ADHESIVES -DETERMINATION OF TENSILE STRENGTH OF BUTT JOINTS” “ and the follow points are discussed in more detail: Adhesives-Determination of tensile strength of butt joints, Introduction of Centrifugal Adhesion Testing, Comparison of Testing Methods.
Single Femtosecond Laser-Pulse-Induced Superficial Amorphization and Re-Crystallization of Silicon
(2021)
Superficial amorphization and re-crystallization of silicon in <111> and <100> orientation after irradiation by femtosecond laser pulses (790 nm, 30 fs) are studied using optical imaging and transmission electron microscopy. Spectroscopic imaging ellipsometry (SIE) allows fast data acquisition at multiple wavelengths and provides experimental data for calculating nanometric amorphous layer thickness profiles with micrometric lateral resolution based on a thin-film layer model. For a radially Gaussian laser beam and at moderate peak fluences above the melting and below the ablation thresholds, laterally parabolic amorphous layer profiles with maximum thicknesses of several tens of nanometers were quantitatively attained. The accuracy of the calculations is verified experimentally by high-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (STEM-EDX). Along with topographic information obtained by atomic force microscopy (AFM), a comprehensive picture of the superficial re-solidification of silicon after local melting by femtosecond laser pulses is drawn.
Sufficient adhesion/tensile strength are basic requirements for any coating/composite material. For coatings, adhesive strength in N/mm2 is of Major interest for various applications such as decorative and water-repellent coatings on wood (paints and varnishes), optical coatings on glass and polymers (reflectors and filters), electrical coatings on semiconductors, glass and polymers (conducting and bondable layers), mechanical coatings on metals and polymers (wear-reduction, scratch-resistance) and adhesion-promoting layers. For composite materials, tensile strength in N/mm2 is also a key quantity for carbon fiber reinforced composites (CFC), laminates and adhesive-bonded joints. Centrifugal adhesion testing (CAT) transfers the single-sample tensile test from a tensile or universal testing machine into an analytical centrifuge as multiple-sample test of up to eight test pieces. The one-sided sample support instead of a two-sided sample clamping and the absence of mounting- and testing-correlated shear forces provides fast and reliable results both for adhesive strength and bonding strength by means of bonded test stamps. For bonding strength, the evaluation of failure pattern from microscopic inspection is required in order to determine the failure pattern according to ISO 10365 such as adhesive failure (AF), delamination failure (DF) and cohesive failure (CF). Hence, one test run by CAT-technology provides either statistics or ranking of up to eight samples at once. For adhesive strength of coatings, a variety of examples is discussed such as ALD-Al203 layers as adhesion promoters, evaporated Ag-layers on N-BK7 glass, sputtered Cr- and Al-layers on Borofloat 33 glass, evaporated Au-films on N-BK7 glass and sputtered SiO2 -layers on CR39 Polymer. Provided adhesive or bonding strength are high enough, the substrate or the joining part may also fail.
The quantitative determination of adhesion and cohesion properties is a key requirement for adhesive-bonded joints and coated components in both R&D and Quality assurance. Because of the huge variety of layer/substrate Systems in terms of materials and large thickness range, adhesion tests display the same diversity as layer/substrate systems. There are only two tensile testing procedures available, that determine adhesive strength in terms of force per area (N/mm²), the single-sample pull-off test in a tensile testing machine and the multiple-sample-test using the Centrifugal Adhesion Testing (CAT) Technology.
The CAT Technology is a testing method which uses centrifugal force as tensile testing force in a multiple-sample arrangement within a drum rotor of a Desktop centrifuge. Hence, the adhesive/bonding strength A/B can be determined on a statistical basis under identical testing conditions for up to eight samples.
A variety of examples for bonding strength of adhesives, adhesive strength of coatings and compound strength of composite materials is discussed such as metalto-metal and glass-to-metal bonding, sputtered SiO2-layers on CR39 Polymer and carbon fiber reinforced polymer.
Phage display biopanning with Illumina next-generation sequencing (NGS) is applied to reveal insights into peptide-based adhesion domains for polypropylene (PP). One biopanning round followed by NGS selects robust PP-binding peptides that are not evident by Sanger sequencing. NGS provides a significant statistical base that enables motif analysis, statistics on positional residue depletion/enrichment, and data analysis to suppress false-positive sequences from amplification bias. The selected sequences are employed as water-based primers for PP-metal adhesion to condition PP surfaces and increase adhesive strength by 100% relative to nonprimed PP.
For the vast majority of ellipsometric measurements, the application of planar substrates is mandatory and requires a proper sample alignment prior to the measurement. Here, the authors present a generalized approach of how to extract the isotropic ellipsometric sample parameters from an imaging Mueller-matrix measurement even if the sample is significantly misaligned. They validate the method by layer-thickness calculations based on imaging Mueller-matrix measurements of flat crystalline silicon samples that were misaligned on purpose. Furthermore, they also exploit this method’s capabilities to perform spatially resolved layer-thickness measurements of a single-layer indium-tin-oxide coating on a fused-silica microlens without the need of realignment or repositioning of the sample during the measurement.
The authors describe and interpret curvature-related changes to the ellipsometric readout. As model system for a concave curvature, a set of three spherical microscopic indents in silicon (100) of different sizes was prepared by instrumented indentation testing using a spherical indenter. For reference, these samples were characterized by AFM to reveal the topography of each structure. The concavelike indents were analyzed by Mueller-Matrix imaging ellipsometry to extract lateral intensity images of 12 elements of the Mueller-Matrix. As a result of the detailed analysis of the image elements m22, m23, and m14, it was possible to correlate intensity changes and symmetry properties to depolarization and cross polarization induced by the edge threshold and the curved surface of the indent.
Up until several years ago, tensile and compressive tests have been exclusively carried out as single-sample tests within a tensile, hardness or universal testing machine. The availability of centrifuge technology changed this situation in 2013 in several ways because centrifugal force is used as testing force within a rotational reference frame.
Firstly, multiple-sample strength testing became feasible for both tensile load condi-tions, e.g. determination of composite, bonding or adhesive strength, and compressive load conditions, e.g. hardness, compressibility and compactibility. Secondly, there is no need for a two-sided sample clamping and double-cardanic suspensions as samples are simply inserted using a one-sided sample support. Thirdly, shear forces can be avoided by means of guiding sleeves which steer test stamps acting as mass bodies for either tensile or compressive testing. Fourthly, up to eight samples can be tested under identical conditions within a very short period of time, typically within 15 minutes including sample loading and unloading. Hence, either a reliable statistics (of identical samples) or a ranking (of different samples) can be derived from one test run.
The bench-top test system is described in detail and demonstrated that centrifugal force acts as testing force in an appropriate way because Euler and Coriolis force do not affect the testing results. Examples for both tensile strength testing, i.e. bonding strength of adhesives-bonded joints and adhesive strength of coatings, and compres-sive strength testing, i.e. Vickers-, Brinell- and ball indentation hardness and deter-mination of spring constants, are presented, discussed and compared with conven-tional tests within tensile, hardness or universal testing machines.
At present, a maximum testing force of 6.5 kN can be realized which results at test stamp diameters of 5 mm, 7 mm, and 10 mm in tensile or compressive stress values of 80 MPa, 160 MPa, and 320 MPa. For tensile strength, this is already beyond bonding strength of cold- and warm-curing adhesives. Moreover, centrifuge technology is compliant to standards such as EN 15870, EN ISO 4624, EN ISO 6506/6507 and VDI/VDE 2616. Programmable test cycles allow both short-term stress and log-term fatigue tests. Based on a variety of examples of surface and bonding technology, applications in both fields R&D and QC are presented. Meanwhile, centrifuge technology is also accredited according to DIN EN ISO/IEC 17025.
The in-situ monitoring of electrochemical deposition (ECD) processes is still a challenge regarding the measurement of the effective temperature of the substrate and the formation of mechanical stress in the layer under given plating conditions. Monitoring problems can be solved by applying a pre-coated fiber Bragg grating (FBG) to the electrolytic process as the shift of the Bragg wavelength is affected by both the temperature of the electrolyte near the substrate and the stress formation in the growing layer. The experimental FBG set-up and the quantitative determination of temperature- and stress-related strain is described for a nickel-iron electrolyte.
Transparent conductive oxide (TCO) films are a vital part of a large part of modern technology. The production of TCO materials has sparked much development in plasma coating technology. Quality control measurements of these layers are therefore important in many fields of optics and electronics such as high efficiency thin film photovoltaics. In this presentation, we report on optical measurements of ZnSnOx layers generated by DC/RF magnetron plasma co-sputtering. By changing the respective power on two different targets, the overall power, the gas composition and post-treatment, the properties of this type of layers can be varied in a number of parameters. The optical, electrical, and chemical properties of TCO layers are the technically most important properties together with the layer thickness. The dielectric function of layers is accessible by means of spectroscopic ellipsometry, which also yields the very important value for the layer thickness at the same time. It would be a significant step forward in quality control to use this non-destructive method also as a fast test for electrical properties. Therefore, we report on the optical properties connected to the production parameters, and also on our preliminary results connecting the optical dielectric function (in the visible and near infrared) to the electrical conductivity of the layers. We discuss the effect of deposition parameters on the optical properties of the layers and present an approach for correlating optical and electrical properties. Further, we discuss the question of accuracy of optical properties gained from model-fit-based optical methods and the use of different parameterised models for the dielectric function to achieve this.
The paper addresses the “State-of-the-Art in Multiple-Sample Evaluation of Adhesive and Bonding Strength” and the following points are discussed in more detail:
1. Motivation (coatings, varnishes, tapes, laminates, CFRP, adhesive-bonded joints)
2. Conventional single-sample testing (evaluation of adhesive and bonding strength; failure pattern)
3. Multiple-sample handling (MSH), bonding (MSB), and testing: centrifugal adhesion testing (CAT) (multiple-sample approach, tensile test within a centrifuge)
4. Application examples of CAT-Technology™ (laminates, optical coatings, CFRP joints)
Finally, a summary is given regarding status quo and benefits of CAT-technology under tensile stress conditions whereas examples of testing in a centrifuge under compressive stress conditions are mentioned in the outlook.
Bonding strength is crucial on polymers of low surface energy, for clean surfaces limited to 0.5, 1, and 2 MPa for PTFE, PP, and PE. Plasma treatment may improve bonding strength by a factor of 2 (PTFE) or 5 (PP and PE). The efficiency of treatment is usually 10% as both low pressure and atmospheric pressure processes show low topographic conformity.
Besides, lifetime of activation/modification is rather short. Hence, bonding has to be carried out immediately after plasma treatment.
The concept of plasma-assisted ALD (atomic layer deposition) interlayers was introduced in the project HARFE of SENTECH (modification/deposition/in-situ monitoring) and BAM (bonding, characterization, testing). ALD deposition has a high surface conformity and for dielectric films of Al2O3 also a good long-term stability given that the films are dense enough.
Based on TMA and O2/O3 precursors, ALD layer stacks from 60 to 375 monolayers were prepared under different conditions. For a transfer time of 24 hours from deposition to measurement, bonding strength could be increased up to 5 MPa (PTFE) respectively 10 MPa (PP, PE). The huge potential of ALD layers as adhesive interlayers was demonstrated for Al2O3 on stainless steel with bonding strength beyond 15 MPa, i.e. interface
strength within the ALD stack is also in this range.
This is a prerequisite for subsequent PVD/CVD-deposition in hybrid systems. By means of the SI ALD LL system of SENTECH thermal and plasma-supported ALD processes can be alternatively realized.
Ellipsometric in-situ monitoring provides monolayer sensitivity and reveals that the efficient bonding of the lower ALD layers on the polymer has to be further improved. Testing of bonding strength was realized by CAT (centrifugal adhesion testing) technology. It was shown that ALD modification correlates with the increase of surface energy and bonding strength.
The talk addresses the STANDARDIZATION OF ELLIPSOMETRY and the following points are discussed in more detail: historical background of ellipsometry, history of International Conferences on Ellipsometry, Workshops Ellipsometry in Germany and Europe, information on German/European Working Group Ellipsometry, technical/industrial importance of ellipsometry, applications on non-ideal material systems and standardization activities on ellipsometry.
Multi-functional coatings are a key requirement for surface engineering. General demands are adhesion and long-term stability under service conditions. The modification of surfaces by means of PVD-, ECD- or hybrid processes allows an add-on functionalization of surfaces by a huge diversity of materials with both lateral and vertical micro-/nano-designs. This fact is a prerequisite for micro- and sensor-systems in lab-on-chip and sensor-on-chip technology. Two layer-based sensor principles are presented, i.e. surface plasmon resonance enhanced spectroscopic ellipsometry (SPREE) for detection of hazardous gases and magneto-optical sensors on smart-coated fiber Bragg gratings (FBG) for structural health monitoring (SHM).
The interdependence of substrate features, coating properties, and layer design is discussed firstly for gas sensitivity and selectivity of SPREE-sensors and secondly for sensitivity and selectivity of magneto-strictive coatings to mechanical strain or external magnetic fields resulting in an optical displacement of the Bragg wavelength of FBG-sensors. Moreover, generic features such long-term stability, crucial process-related fabrication conditions, and effects of operational and environmental parameters are discussed with respect to the sensor performance. It has been shown that appropriate layer design and adapted selection of layer materials (SnOx/Au, Fe/Ni:SnOx/Au; Ni/NiFe-Cu-Cr) result in improved sensor parameters and may enable new sensor applications.
The application of PVD-coatings ranges from mechanical engineering, i.e. thicker tribological coatings, to precision optics, i.e. thinner optical coatings. For physical vapor deposition (PVD) technologies such as evaporation, sputtering, ion beam assisted/driven deposition, vacuum is a prerequisite for two reasons: at first process-related ones (evaporation source, plasma discharge, and mean free path) and at second coating-related ones (pure, perfect, and dense films). Usually, the goal is a homogenous coating of defined stoichiometry and micro-structure without any imperfection.
However, the implementation of micro- or nano-particles may occur accidentally or delibe-rately. Independent of the particle origin, there are two fundamental rules regarding coating functionality: at first, the larger the particle diameter to coating thickness ratio the more affected the functionality of the coating, and at second, the larger the material contrast in terms of the functional feature of interest the more affected the coating performance. Hence, embedded particles have to be avoided for the majority of thin films by all means. The unintended implementation of particles usually results in a malfunction of the coating from the beginning or is at least considered as a weak point of the coating creating a time-dependent defect under service conditions. The intended implementation of particles on surfaces and in coatings may create add-on features, topographic ones and functional ones, however, the facts mentioned hold true.
Examples of particle-initiated coating defects are demonstrated in dependence on the origin and the field of application. Strategies for deliberate attachment/embedding of particles on surfaces/in coatings are discussed regarding process compatibility and coating integrity. For industrial applications, both the validation of process compatibility of particle injection and the plasma resistance of particles under vacuum and plasma conditions have to be confirmed. Further points of interest are the homogeneity of particle distribution and the avoidance of particle agglomeration which is still a crucial point for dry dispersed particles. So far, technical applications are limited to PVD hybrid coatings, plasma dispersion coatings are still a challenge except for applications where homogeneity is not required as in case of product authentication.
Imaging of surfaces regarding topographical, morphological, micro-structural, and chemical features is a key requirement for quality control for the identification of contaminated, degraded, damaged or deliberately modified surface areas vs. clean, virgin, undamaged or unmodified regions. As optical functions may represent any of these changes on the micro- and nano-scale, imaging ellipsometry (IE) is the technique of choice using either intensity, phase, or/and amplitude contrast for visualization of low-contrast surface modifications [1, 2]. Defects or surface and film features whether native or artificial, intended or unintended, avoidable or unavoidable as well as surface pattern are of interest for quality control. In contrast to microscopic techniques operated at normal incidence, ellipsometry as oblique-incidence technique provides improved contrast for vertically nano-scaled add-on or sub-off features such as ultra-thin transparent films, metallic island films, carbon-based thin films, laser modification or laser induced damage, dried stain, cleaning agent or polymeric residue. Two-sample reference techniques, i.e. referenced spectroscopic ellipsometry (RSE) may further increase sensitivity and decrease measurement time. In case of particulate accumulations depolarization contrast imaging (DCI) may improve the lateral resolution beyond the Abbe limit. This has been proven for silica spheres as reference in terms of single particles, particulate accumulations or particulate monolayers and layer stacks. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used for reference measurements of particle diameter, particle height, or particulate layer/accumulation thickness. It has been shown that single silica particles of 250 nm in diameter, i.e. at least a factor of 4 better than the lateral resolution limit as of now, can be visualized on even substrates. However, the ellipsometric measurement of particle diameters of this size needs further efforts interpretation.
The paper addresses “WHITE LIGHT INTERFERENCE MICROSCOPY, ELLIPSOMETRY, AND INSTRUMENTED INDENTATION TESTING AS REFERENCE PROCEDURES“ and is subdivided in the following sections: 1. Measurement vs. testing vs. reference procedures, 2. White light interference microscopy (WLIM) for determination of step height h, 3. Spectroscopic ellipsometry (SE) for determination of layer thickness d and 4. Instrumented indentation testing (IIT) for determination of indentation hardness HIT. The following points are discussed in more detail: methodology of measurement and testing, uncertainty budgets for direct (WLIM), model-based (SE) and formula-based (IIT) reference procedures by means of specific examples. It is shown that standardization efforts are connected to reference procedures.
In this study, thickness related changes of the optical properties of doped tin oxide were studied. Two different sets of samples were prepared. The first set was doped with iron or nickel on silicon substrate with thicknesses of 29–56 nm, the second was iron doped on gold/glass substrate with 1.6–6.3 nm. The optical constants were determined by using spectral ellipsometry (SE) followed by modelling of the dielectric function with an oscillator model using Gaussian peaks. The analysis of the optical constants shows a dependence of the refraction and the absorption on the thickness of the doped tin oxide coating. In addition to the tin oxide absorption in the UV, one additional absorption peak was found in the near-IR/red which is related to plasmonic effects due to the doping. This peak shifts from the near-IR to the red part of the visible spectrum and becomes stronger by reducing the thickness, probably due to the formation of metal nanoparticles in this layer. These results were found for two different sets of samples by using the same optical model. Afterwards the second sample set was tested in the Surface Plasmon Resonance Enhanced Ellipsometric (SPREE) gas measurement with CO gas. It was found that the thickness has significant influence on the sensitivity and thus the adsorption of the CO gas. By increasing the thickness from 1.6 nm to 5.1 nm, the sensing ability is enhanced due to a higher coverage of the surface with the over coating. This is explained by the high affinity of CO molecules to the incorporated Fe-nanoparticles in the tin oxide coating. By increasing the thickness further to 6.3 nm, the sensing ability drops because the layer disturbs the SPR sensing effect too much.
The 7th International Conference on Spectroscopic Ellipsometry (ICSE-7) was held in Berlin in June 2016, jointly organised by ICSE and BAM. The publication of the proceedings special issue in Applied Surface Science follows this event. In the special issue, about 100 articles on current topics of optics and surface science related to ellipsometry, polarimetry, and similar techniques are presented, underpinning the high significance of these techniques for many fields of materials science.
Visualization of surface modifications may be very challenging for coating/substrate systems of either almost identical optical constants, e.g. transparent films on substrates of the same material, or minor film thickness, substance quantity and affected area, e.g. ultra-thin or island films. Methods for visualization are optical microscopy (OM), imaging ellipsometry (IE), and referenced spectroscopic ellipsometry (RSE). Imaging ellipsometry operates at oblique incidence near Brewster angle of the bare, clean or unmodified substrate. In this configuration, reflected intensities are rather weak. However, the contrast to add-on and sub-off features may be superior. Referenced spectroscopic ellipsometry operates in a two-sample configuration but with much higher intensities. In many cases, both ellipsometric techniques reveal and visualize thin films, printed-pattern, laser-induced changes, and impurities better than optical microscopy. In particular for stratified homogeneous modifications, ellipsometric techniques give access to modelling and hence thickness determination. Modifications under investigation are polymer foil residue on silicon, laser-induced changes of ta-C:H coatings on 100Cr6 steel, imperfections of ta-C:H on thermal silicon oxide, degradation of glass, thin film tin oxide pattern on silicon, printed and dried pattern of liquids such as deionized water, cleaning agents, and dissolved silicone. © 2016 Elsevier B.V. All rights reserved.
The talk addresses layer-based sensors for monitoring applications. In particular, sensor principles surface plasmon resonance (SPR), air-coupled ultrasonic, and magneto-optical coupling are discussed. Optical sensors on planar substrates are prepared by sol-gel, CVD- and PVD deposition techniques, ultrasonic sensors on planar and curved substrates are made by means of PVD processes, and magnetostrictive coatings for magneto-optical sensors are deposited on fibre-based Bragg gratings (FBGs) using PVD and ECD techniques. For all kinds of sensors design and function are explained and discussed, i.e. regarding sensitivity. It is shown that a) SPR enhanced ellipsometry is a promising tool for gas monitoring of hazardous gases, that b) thermos-acoustic and piezo-electric pulse-echo techniques are relevant for damage inspection of hidden volume defects of CFRPs, and that c) magnetostrictive-optical sensors with self-calibrating (magnetic reference field) function are useful for structural health monitoring in terms of strain sensors.
Background: Gas sensors are very important in several fields like gas monitoring, safety and environmental applications. In this approach, a new gas sensing concept is investigated which combines the powerful adsorption probability of metal oxide conductive sensors (MOS) with an optical ellipsometric readout. This concept Shows promising results to solve the problems of cross sensitivity of the MOS concept.
Results: Undoped tin oxide (SnOx) and iron doped tin oxide (Fe:SnOx) thin add-on films were prepared by magnetron sputtering on the top of the actual surface plasmon resonance (SPR) sensing gold layer. The films were tested for their sensitivity to several gas species in the surface plasmon resonance enhanced (SPREE) gas measurement. It was found that the undoped tin oxide (SnOx) shows higher sensitivities to propane (C3H8) then to carbon monoxide (CO). By using Fe:SnOx, this relation is inverted. This behavior was explained by a change of the amount of binding sites for CO in the layer due to this iron doping. For hydrogen (H2) no such relation was found but the sensing ability was identical for both layer materials. This observation was related to a different sensing mechanism for H2 which is driven by the Diffusion into the layer instead of adsorption on the surface.
Conclusion: The gas sensing selectivity can be enhanced by tuning the properties of the thin film overcoating. A relation of the binding sites in the doped and undoped SnOx films and the gas sensing abilities for CO and C3H8 was found. This could open the path for optimized gas sensing devices with different coated SPREE sensors.
Interlaboratory comparison: optical property classification of carbon-based films by ellipsometry
(2017)
The paper addresses the “INTERLABORATORY COMPARISON: OPTICAL PROPERTY CLASSIFICATION OF CARBON-BASED FILMS BY ELLIPSOMETRY” and the following points are discussed in more detail: Established classification for mechanical properties, Complementary classification for optical properties, Ellipsometry for determination of optical constants n-k plane as material fingerprint, Samples, participants & set-ups (samples: Japan, participants: Japan, Germany, France, set-ups: Japan, Germany, USA) and Results of interlaboratory comparison: thickness, n & k.
Iron-doped SnO2 coatings were deposited in a 50 kHz DC-pulsed magnetron sputtering discharge. The pulses had a duration of 4 µs in selected gas mixtures from pure argon up to
60% of oxygen at a constant total pressure of 0.2 Pa. A single target of SnO2 with Fe inset was used. The mass spectrometry study detected the gas-related ions Ar+, O2+ and O+, where the last one becomes the dominant positive ion at higher oxygen contents. Atomic oxygen ions had a higher energy as it resulted from the collision-caused dissociation on the target surface. The tin-related species were detected as Sn+ and SnO+. SnO2+ species were not detected. The deposition rate decreased by using gas mixtures with oxygen as well as the corresponding amount of Sn-related species in the plasma. The increase of oxygen also increased significantly the sheet resistance of the films. The XPS study showed that the iron concentration decreased by using additional oxygen. But the O/Sn ratio in the coatings was constant, contrary to the increased FeO/Fe ratio in the films. An additional analysis of the coatings by spectroscopic ellipsometry has shown a dependence of the polarizability and the permittivity on the amount of oxygen used during the deposition. In contrast, the study has found no such dependence for the absorption of the layers.
The comprehensive knowledge of material properties as engineered and the material behavior in use is of huge importance for the functionality and reliability of processes and products. Hence, the accurate determination of material properties is a prerequisite for the applicability of a given material. Nowadays, macroscopic product features are originated by material properties on the microscopic and nanoscopic scale. This is a general challenge for uncertainty budgets in measurement and testing based on a conformity assesment.
Testing labs accreditated according to DIN EN ISO/IEC 17025 have to meet these demands. This paper focuses on the measurement of physical quantities (measurand with value and unit) and on the testing of material properties (qualitative, semi-quantitative or quantitative characteristics) of solid state materials. For both measurement and testing, the expression of uncertainty according to GUM is essential. Regarding the object/sample one has to subdivide in surface and bulk features, from the measurement/testing point of view destructive vs. nondestructive procedures have to be distinguished. Moreover, direct mesurement/testing and model-based determination of quantities/properties of interest require different approaches regarding the expression of uncertainty. For surface quantities and properties as discussed here, further considerations have to be made with respect to localized (lateral extension, native or artificial) or stratified (homogeneity and isotropy) material features vs. mapping (integration area) and imaging (lateral resolution and field of analysis) specifications of the measurement/testing procedure.
The concept of uncertainty budgets and the expression of uncertainty is introduced and discussed in more detail for the nondestructive model-based determination of thickness by spectroscopic ellipsometry (SE), the destructive determination of adhesion by means of centrifugal adhesion testing (CAT). It is shown that the expression of uncertainty for these examples and real materials requires different approaches resulting in either quantitity values with unit or qualitative/quantititative attributes with calculated/estimated uncertainties in agreement with GUM.
The multiple-sample approach by means of centrifugal adhesion testing (CAT-technology) allows the determination of bonding strength of adhesive-bonded joints on a statistical basis of up to eight samples. Therefore, it is obvious to ensure the continuous handling and identical processing of an octet of samples within the entire process chain of wet-chemical cleaning, plasma-chemical pre-treatment, bonding of samples, and testing of bonding strength. Within the multiple-sample bonding set-up (MPKV-technology) a defined bonding pressure can be adjusted regardless the actual number of samples. A comparison of single- and multiple-sample approach is made for bonding strength of selected adhesives, double-sided adhesive tapes and different material combinations [stainless steel (V2A) vs. stainless steel, polyamide (PA), or polypropylene (PP)]. It is shown that both technologies improve reliability of results
The future commercial prospects for adhesive tapes are very good and its application range is very broad. From every-day-use in office, packaging, maintenance, and quick repair in workshops, it ranges from handicraft work, medical purposes and cosmetics up to workmanship. The study describes a new multi-sample approach in adhesive tape testing from theoretical background, preparation of test specimen for tensile as well as shear testing, detailed measurement procedures up to analysis and result interpretation. Various types of single and double-sided pressure sensitive adhesive tapes supplied by different manufacturers were investigated and compared
The validation of the plasma compatibility of particles is a prerequisite for their application in plasma dispersion layers. The goal is the realization of functional add-on features on surfaces, in films and coatings. Although intended applications primarily address nanoparticles, the compatibility tests were carried out at first with particles in the lower micrometer range in order to investigate material-, fluorescent marker- or surface-based degradation effects in a simple manner.
Plasma compatibility implies at least the short-term acceptance of charged species, plasma-UV radiation, vacuum and elevated temperatures. Otherwise, effects on geometrical dimensions, chemical bonds, fluorescence efficiency and plastic-elastic properties are expected.
The plasma compatibility of monodisperse fluorescent-labeled particles to microwave excitation was evaluated by means of microscopic and spectroscopic investigation methods (light, fluorescence, confocal, atomic force microscopy and FTIR). This study comprises particles of different materials (SiO₂, PMMA, PS, MF) and sizes (from 50 nm to 10 μm).
A special preparation technique ensures that smallest geometry changes of particles can be measured by atomic force microscopy. For the selected plasma conditions (P = 600 W, f = 2.46 GHz, d = 10 cm) and an exposure time of 10 minutes, the geometry of SiO₂ particles (approx. 1.7 μm) remains nearly unchanged, whereas PS particles shrink in diameter by 6% and PMMA particles by 11%. For selected core-particles (SiO₂, MF) with fluorescencemarked (rhodamine) shell-polyelectrolytes no remarkable plasma degradation of the fluorescence intensity was observed for the above mentioned plasma conditions, however a doubling of exposure time already results in a significant decrease in intensity. Two different injection systems have been studied for the particle injection into the plasma deposition process.
One of the selected systems also proves process compatibility regarding the expected pressure differences upon injection
The validation of the plasma compatibility of particles is a prerequisite for their application in plasma dispersion layers. The goal is the realization of functional add-on features on surfaces, in films and coatings. Although intended applications primarily address nanoparticles, the compatibility tests were carried out at first with particles in the lower micrometer range in order to investigate material-, fluorescent marker- or surface-based degradation effects in a simple manner.
Plasma compatibility implies at least the short-term acceptance of charged species, plasma-UV radiation, vacuum and elevated temperatures. Otherwise, effects on geometrical dimensions, chemical bonds, fluorescence efficiency and plastic-elastic properties are expected.
The plasma compatibility of monodisperse fluorescent-labeled particles to microwave excitation was evaluated by means of microscopic and spectroscopic investigation methods (light, fluorescence, confocal, atomic force microscopy and FTIR). This study comprises particles of different materials (SiO2, PMMA, PS, MF) and sizes (from 50 nm to 10 μm).
A special preparation technique ensures that smallest geometry changes of particles can be measured by atomic force microscopy. For the selected plasma conditions (P = 600 W, f = 2.46 GHz, d = 10 cm) and an exposure time of 10 minutes, the geometry of SiO2 particles (approx. 1.7 μm) remains nearly unchanged, whereas PS particles shrink in diameter by 6% and PMMA particles by 11%. For selected core-particles (SiO2, MF) with fluorescencemarked (rhodamine) shell-polyelectrolytes no remarkable plasma degradation of the fluorescence intensity was observed for the above mentioned plasma conditions, however a doubling of exposure time already results in a significant decrease in intensity. Two different injection systems have been studied for the particle injection into the plasma deposition process.
One of the selected systems also proves process compatibility regarding the expected pressure differences upon injection.
Glühentladung optischer Ausstrahlungsspektroskopie (GDOES) wurde ursprünglich für die elementare Analyse von Größenmaterialien entwickelt. Mehrere Gruppen führten diese Methode zur Analyse von Anstrichen, Laienstapeln und dünnen Filmen durch. In den frühen Neunzigern wurde eine ISO-TC 201-Arbeitsgruppe gegründet, um Normen für alle Formen der Glühentladungsspektroskopie (GDS) zu entwickeln und die Fähigkeiten der Oberflächenchemikalien-Analyse zu beurteilen, insbesondere für die Tiefe von gestuften Systemen. Die Quantifizierung von Tiefenprofilen, d.h. die Umwandlung von Intensitäts-Zeit- Profilen in Konzentrierungs-Tiefen-Profile ist für dc-mode entwickelt worden. 1997 wurde ein VAMAS TWA 2 Vorschlag für ein Referenzanstrich für GD-OES Tiefe gemacht. Entsprechend dem VAMAS Beurteilungsverfahren wurde dieser Vorschlag 1998 mit einigen geringfügigen Änderungen genehmigt.