Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Erscheinungsjahr
- 2019 (976) (entfernen)
Dokumenttyp
- Vortrag (443)
- Zeitschriftenartikel (257)
- Posterpräsentation (116)
- Beitrag zu einem Tagungsband (104)
- Sonstiges (18)
- Forschungsbericht (10)
- Buchkapitel (9)
- Dissertation (6)
- Monografie (3)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (3)
- Beitrag zu einem Sammelband (2)
- Sammelband (Herausgeberschaft für den kompletten Band) (1)
- Tagungsband (Herausgeberschaft für den kompletten Band) (1)
- Handbuch (1)
- Preprint (1)
- Forschungsdatensatz (1)
Sprache
- Englisch (731)
- Deutsch (235)
- Mehrsprachig (8)
- Russisch (1)
- Spanisch (1)
Schlagworte
- Additive Manufacturing (47)
- Corrosion (45)
- Korrosion (33)
- Additive manufacturing (29)
- Additive Fertigung (20)
- Microstructure (17)
- Nanoparticles (17)
- Fluorescence (16)
- Computed tomography (15)
- Mechanochemistry (14)
Organisationseinheit der BAM
- 6 Materialchemie (229)
- 9 Komponentensicherheit (215)
- 7 Bauwerkssicherheit (164)
- 8 Zerstörungsfreie Prüfung (163)
- 5 Werkstofftechnik (161)
- 9.3 Schweißtechnische Fertigungsverfahren (118)
- 7.6 Korrosion und Korrosionsschutz (96)
- 8.5 Röntgenbildgebung (84)
- 6.6 Physik und chemische Analytik der Polymere (70)
- 1 Analytische Chemie; Referenzmaterialien (68)
- 9.4 Integrität von Schweißverbindungen (63)
- 4 Material und Umwelt (55)
- 6.3 Strukturanalytik (55)
- 5.1 Mikrostruktur Design und Degradation (51)
- 8.0 Abteilungsleitung und andere (51)
- 1.2 Biophotonik (44)
- 2 Prozess- und Anlagensicherheit (43)
- 6.1 Oberflächen- und Dünnschichtanalyse (40)
- 6.2 Material- und Oberflächentechnologien (40)
- 3 Gefahrgutumschließungen; Energiespeicher (39)
- 5.4 Multimateriale Fertigungsprozesse (35)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (32)
- 6.7 Materialsynthese und Design (29)
- 5.2 Metallische Hochtemperaturwerkstoffe (28)
- 5.6 Glas (27)
- 9.5 Tribologie und Verschleißschutz (24)
- 5.3 Polymere Verbundwerkstoffe (23)
- 7.1 Baustoffe (23)
- 8.4 Akustische und elektromagnetische Verfahren (21)
- 4.5 Kunst- und Kulturgutanalyse (19)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (18)
- 4.1 Biologische Materialschädigung und Referenzorganismen (16)
- 9.0 Abteilungsleitung und andere (16)
- 4.2 Material-Mikrobiom Wechselwirkungen (15)
- 2.1 Sicherheit von Energieträgern (12)
- 3.2 Gefahrguttanks und Unfallmechanik (12)
- 7.4 Baustofftechnologie (12)
- 9.2 Versuchsanlagen und Prüftechnik (12)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (10)
- 1.5 Proteinanalytik (9)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (9)
- 5.5 Materialmodellierung (9)
- 2.0 Abteilungsleitung und andere (8)
- 8.6 Faseroptische Sensorik (8)
- 2.2 Prozesssimulation (7)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (7)
- 3.0 Abteilungsleitung und andere (7)
- 3.4 Sicherheit von Lagerbehältern (7)
- 2.4 Prüfung und Bewertung von Explosivstoffen/Pyrotechnik (6)
- 5.0 Abteilungsleitung und andere (6)
- 1.4 Prozessanalytik (5)
- 3.3 Sicherheit von Transportbehältern (5)
- 1.1 Anorganische Spurenanalytik (4)
- 1.9 Chemische und optische Sensorik (4)
- 4.3 Schadstofftransfer und Umwelttechnologien (4)
- 6.0 Abteilungsleitung und andere (4)
- 9.6 Additive Fertigung metallischer Komponenten (4)
- 2.3 Einstufung von Gefahrstoffen und -gütern (3)
- 4.0 Abteilungsleitung und andere (3)
- 7.0 Abteilungsleitung und andere (3)
- S Qualitätsinfrastruktur (3)
- 7.2 Ingenieurbau (2)
- S.2 Digitalisierung der Qualitätsinfrastruktur (2)
- Z Zentrale Dienstleistungen (2)
- Z.1 Organisation, Controlling (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 1.8 Umweltanalytik (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- P Präsident (1)
- P.0 Präsident und andere (1)
- S.0 Abteilungsleitung und andere (1)
Eingeladener Vortrag
- nein (443)
Dielectric strength testing of ceramics can be performed with various setups and parameters. Comparisons of results from different sources are often not meaningful, because the results are strongly dependent on the actual testing procedure. The aim of this study is to quantify the influence of voltage ramp rate, electrode size, electrode conditioning, and sample thickness on the measured AC dielectric strength of a commercial alumina. Mean values, Weibull moduli, and failure probabilities determined in standardized short time tests are evaluated and related to withstand voltage tests. Dielectric strength values in the range from 21.6 to 33.2 kV/mm were obtained for the same material using different testing procedures. Short time tests resulted in small standard deviations (< 2 kV/mm) and high Weibull moduli around 30, while withstand tests at voltage levels with low and virtual zero failure probability in short time tests resulted in large scatter of withstand time and Weibull moduli < 1. The strong decrease in Weibull moduli is attributed to progressive damage from partial discharge and depolarization during AC testing. These findings emphasize the necessity of a thorough documentation of testing procedure and highlight the importance of withstand voltage tests for a comprehensive material characterization.
Preactivation Crosslinking - An Efficient Method for the Oriented Immobilization of Antibodies
(2019)
Crosslinking of proteins for their irreversible immobilization on surfaces is a proven and popular method. However, many protocols lead to random orientation and the formation of undefined or even inactive by-products. Most concepts to obtain a more targeted conjugation or immobilization requires the recombinant modification of at least one binding partner, which is often impractical or prohibitively expensive. Here a novel method is presented, which is based on the chemical preactivation of Protein A or G with selected conventional crosslinkers. In a second step, the antibody is added, which is subsequently crosslinked in the Fc part. This leads to an oriented and covalent immobilization of the immunoglobulin with a very high yield. Protocols for Protein A and Protein G with murine and human IgG are presented. This method may be useful for the preparation of columns for affinity chromatography, immunoprecipitation, antibodies conjugated to magnetic particles, permanent and oriented immobilization of antibodies in biosensor systems, microarrays, microtitration plates or any other system, where the loss of antibodies needs to be avoided, and maximum binding capacity is desired. This method is directly applicable even to antibodies in crude cell culture supernatants, raw sera or protein-stabilized antibody preparations without any purification nor enrichment of the IgG. This new method delivered much higher signals as a traditional method and, hence, seems to be preferable in many applications.
Preactivation crosslinking – An efficient method for the oriented immobilization of antibodies
(2019)
Crosslinking of proteins for their irreversible immobilization on surfaces is a proven and popular method. However, many protocols lead to random orientation and the formation of undefined or even inactive by-products. Most concepts to obtain a more targeted conjugation or immobilization requires the recombinant modification of at least one binding partner, which is often impractical or prohibitively expensive. Here a novel method is presented, which is based on the chemical preactivation of Protein A or G with selected conventional crosslinkers. In a second step, the antibody is added, which is subsequently crosslinked in the Fc part. This leads to an oriented and covalent immobilization of the immunoglobulin with a very high yield. Protocols for Protein A and Protein G with murine and human IgG are presented. This method may be useful for the preparation of columns for affinity chromatography, immunoprecipitation, antibodies conjugated to magnetic particles, permanent and oriented immobilization of antibodies in biosensor systems, microarrays, microtitration plates or any other system, where the loss of antibodies needs to be avoided, and maximum binding capacity is desired. This method is directly applicable even to antibodies in crude cell culture supernatants, raw sera or protein-stabilized antibody preparations without any purification nor enrichment of the IgG. This new method delivered much higher signals as a traditional method and, hence, seems to be preferable in many applications.
The reassessment of bridges is becoming increasingly important. The basic requirement for analyses of structural safety is reliable knowledge about individual structures. This paper introduces the new approach to evaluate the quality of measured data gained from non-destructive testing (NDT) to provide reliable, objective, and relevant information about existing bridges. The purpose is to relate this validated knowledge to probabilistic analyses. Bridging the gap between NDT and numerical reassessments indicates reduced numerical uncertainties and residual service time extensions. This paper deals with an application of this approach using measurement data collected by ultrasonic technique at a prestressed concrete bridge.