Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Erscheinungsjahr
- 2019 (68) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (37)
- Vortrag (21)
- Posterpräsentation (7)
- Sonstiges (3)
Schlagworte
- Fluorescence (16)
- Quantum yield (13)
- Lifetime (12)
- Dye (9)
- Nanoparticle (8)
- Photoluminescence (8)
- NIR (7)
- Nano (7)
- Nanomaterial (7)
- Quantum dot (7)
- Lanthanide (6)
- AIS (5)
- Flow cytometry (5)
- Method (5)
- Multiplexing (5)
- Photophysics (5)
- Quantum dots (5)
- Sensor (5)
- Assay (4)
- Bead (4)
- Calibration (4)
- Encoding (4)
- Mechanism (4)
- Nanoparticles (4)
- Surface chemistry (4)
- Barcoding (3)
- Energy transfer (3)
- IgG (3)
- InP (3)
- Indium phosphide (3)
- Nanomaterialien (3)
- Protein G (3)
- Quality assurance (3)
- SWIR (3)
- Uncertainty (3)
- Upconversion nanoparticle (3)
- Absolute fluorometry (2)
- Additive manufacturing (2)
- Advanced Materials (2)
- Antibody coating (2)
- Antikörper (2)
- Biosensor (2)
- Cleavable probe (2)
- Cytotoxicity (2)
- Degradation (2)
- Funtional Groups (2)
- Herceptin (2)
- IR (2)
- Immunoassay (2)
- Immunocapture (2)
- Immunoglobulins (2)
- Immunoprecipitation (2)
- Immunosensor (2)
- Integrating sphere spectroscopy (2)
- Oriented immobilization (2)
- PEG (2)
- Probe (2)
- Process monitoring (2)
- Protein A (2)
- Proximity-enhanced reaction (2)
- Quantitative Analysis (2)
- Semiconductor nanocrystal (2)
- Sensitization (2)
- Single particle spectroscopy (2)
- Spectroscopy (2)
- Synthesis (2)
- Ternary quantum dots (2)
- Thermography (2)
- Upconversion (2)
- Upconversion nanoparticles (2)
- fluorescence (2)
- 18HLT01 MetVes II (1)
- ABID (1)
- AIS QD (1)
- Acoustic Emission (1)
- Additive Fertigung (1)
- Additive Manufacturing (1)
- Affinity chromatography (1)
- Affinitätschromatographie (1)
- Affinitätsextraktion (1)
- Ameisensäure (1)
- Aneurism (1)
- Antibodies (1)
- Artificial weathering (1)
- BODIPY (1)
- Ball milling (1)
- Bead-based assay (1)
- Biochip (1)
- Bioconjugation (1)
- Borosilikatglas (1)
- Brightness (1)
- Bundesoberbehörden (1)
- C-C coupling (1)
- CE-ICP-MS (1)
- Carbon dot (1)
- Catch and release assay (1)
- Cell (1)
- Central Taurus (1)
- Characterization (1)
- Cleavable linker (1)
- Click chemistry (1)
- Combinatorial chemistry (1)
- Combinatorial polymer libraries (1)
- Conductometry (1)
- Conjugates (1)
- Core/shell quantum dot (1)
- Crosslinker (1)
- Crosslinking (1)
- DPA (1)
- Defect photoluminescence (1)
- Diagnostic antibodies (1)
- Dipole moment (1)
- Druckstabilität (1)
- Drug (1)
- Dual sensing (1)
- Dye degradation (1)
- Dye labeling (1)
- ELISA (1)
- EMPIR project (1)
- ESI MS (1)
- Elastin (1)
- Elemental composition (1)
- Energetic Materials (1)
- Excitation power density (1)
- Extracellualr vesicles (1)
- Extracellular matrix (1)
- Extracellular vesicles (EV) (1)
- FLIM (1)
- FPLC (1)
- FRET (1)
- FTIR (1)
- Ferumoxytol (1)
- Festphasenextraktion (1)
- Fingerprint (1)
- Flow Chemistry (1)
- Fluorescence standard (1)
- Fluorescent label (1)
- Forschungsstrategie (1)
- Friction (1)
- Fully aromatic frameworks (1)
- Gadolinium (1)
- Gallium doping (1)
- Glasmonolith (1)
- Glue (1)
- Gold nanoclusters (1)
- Graphene (1)
- HPLC (1)
- Hot steam (1)
- Human antibodies (1)
- ICP-MS (1)
- Immobilisierung (1)
- Immobilization (1)
- Immunglobulin (1)
- Immunoaffinity extraction (1)
- In situ (1)
- Inflammation (1)
- Infrared Thermography (1)
- Inline NMR Spectroscopy (1)
- Integrated Processes (1)
- Integrating sphere spectroscopy, (1)
- Iron isotope fractionation (1)
- Iron oxide (1)
- Korrelationsmatrix (1)
- LMD (1)
- LT-FCM (1)
- Laser metal deposition (1)
- Lead isotope composition (1)
- Lead-free (1)
- Legionella (1)
- Ligand (1)
- MALDI-TOF (1)
- MOF (1)
- Macrophage (1)
- Magnetic (1)
- Magnetic resonance imaging (1)
- Mass spectrometry (1)
- Massenspektrometrie (1)
- Mechanochemistry (1)
- Method comparison (1)
- Method validation (1)
- Methos comparision (1)
- Microarray (1)
- Microbially induced corrosion (1)
- Microparticle (1)
- Microparticles (1)
- Modeling (1)
- Modelling (1)
- Modular Production (1)
- Moisture (1)
- Multivariate data analysis (1)
- NDT (1)
- NIR dyes (1)
- NMR (1)
- Nanocomposite (1)
- Nanocrystal (1)
- Nanohybrid (1)
- Nanoparticle characterization (1)
- Nanotechnologie (1)
- Nd excitation (1)
- Neuartige Materialien (1)
- Next Generation Sequencing (1)
- Optical Emission Spectroscopy (1)
- Optical assay (1)
- Optical emission spectroscopy (1)
- Optical properties (1)
- Optical spectroscopy (1)
- Ore provenance (1)
- Organic–inorganic nanostructures (1)
- Oxygen sensitive (1)
- PDT (1)
- PH (1)
- Paint (1)
- Peptide (1)
- Peptide Library (1)
- Peptide mass fingerprinting (1)
- Peptides (1)
- Performance validation (1)
- Perovskite (1)
- Phage Display (1)
- Phosphinine (1)
- Photocatalyst (1)
- Photoluminescence quantum yield (1)
- Photooxidation (1)
- Photostability (1)
- Polyethylene Glycol (1)
- Polyethylene glycol (1)
- Polymer particle (1)
- Polymers (1)
- Polyurethane (1)
- Porosity (1)
- Porphyrin (1)
- Precision polymer sequencing (1)
- Priam's treasure (1)
- Process Analytical Technology (1)
- Pseudo peptides (1)
- Quality assurcance (1)
- Quantum yields (1)
- Quinones (1)
- Raman spectroscopy (1)
- Reaction Monitoring (1)
- Reference material (1)
- Reference materials (1)
- Reference methods (1)
- Reference particles (1)
- Regeneration (1)
- Reverse microemulsion (1)
- SWIR photoluminescence (1)
- Saure Hydrolyse (1)
- Screening (1)
- Self-assembly (1)
- Semiconductor (1)
- Sequence-defined oligomer (1)
- Sequencing (1)
- Shape (1)
- Silica coating (1)
- Silver indium sulfide (1)
- Single cell-ICP-ToF-MS (1)
- Single molecule (1)
- Single particle-ICP-ToF-MS (1)
- Single-dot spectroscopy (1)
- Singlet oxygen (1)
- Size (1)
- Small-angle scattering (1)
- Solubilizer (1)
- Sonochemical synthesis (1)
- Speciation analysis (1)
- Stabilization (1)
- Static Mixing (1)
- Stepwise growth (1)
- Surface (1)
- Surface Chemistry (1)
- Surface analysis (1)
- Surface group (1)
- Surface group analysis (1)
- Surface group quantification (1)
- Surfaces (1)
- Suzuki-Miyaura coupling (1)
- Switch (1)
- Temperature (1)
- Therapeutic antibodies (1)
- Thick shells (1)
- Time-gated emission (1)
- Time-resolved flow cytometry (1)
- Titan-Halterung (1)
- Trastuzumab (1)
- Tribofilm (1)
- Triplet-triplet annihilation (1)
- Trojan silver artefacts (1)
- UV Vis (1)
- UpConversion (1)
- Upconverstion (1)
- Vernetzung (1)
- Wastewater (1)
- Wear (1)
- X-ray microspectroscopy (1)
- Yb(III) complex (1)
- Zirconia (1)
- anion-exchange (1)
- antibody (1)
- bacteria (1)
- bacteria detection (1)
- biokompatibel (1)
- flow cytometry (1)
- fluorescence microscopy (1)
- gesintert (1)
- immunoseparation (1)
- lifetime (1)
- magnetic nanoparticle (1)
- method (1)
- nanoparticle (1)
- pH (1)
- particle (1)
- quantum dot (1)
- quantum yield (1)
- screening tes (1)
- single cell-ICP-ToF-MS (1)
- single particle-ICP-ToF-MS (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (68) (entfernen)
Eingeladener Vortrag
- nein (21)
Organic and inorganic micro- and nanoparticles are increasingly used as drug carriers, fluorescent sensors, and multimodal labels in the life and material sciences. Typically, these applications require further functionalization of the particles with, e.g., antifouling ligands, targeting bioligands, stimuli-responjsive caps, or sensor molecules. Besides serving as an anchor point for subsequent functionalization, the surface chemistry of these particles also fundamentally influences their interaction with the surrounding medium and can have a significant effect on colloidal stability, particle uptake, biodistribution, and particle toxicity in biological systems. Moreover, functional groups enable size control and tuning of the surface during the synthesis of particle systems.
For these reasons, a precise knowledge of the chemical nature, the total number of surface groups, and the number of groups on the particle surface that are accessible for further functionalization is highly important. In this contribution, we will will discuss the advantages and limitiations of different approaches to quantify the amount of commonly used surface functional groups such as amino,[1,2] carboxy,[1,2] and aldehyde groups.[3] Preferably, the quantification is carried out using sensitive and fast photometric or fluorometric assays, which can be read out with simple, inexpensive instrumentation and can be validated by complimentary analytic techniques such as ICP-OES and quantitative NMR.
Die gemeinsame Forschungsstrategie der Bundesoberbehörden zur Nanotechnologie wurde 2016 veröffentlicht. Die darin enthaltenen Aufgaben wurden von den Bundesoberbehörden vielfältig bearbeitet. Diese Präsentation gibt einen Überblick über die Projekte, die von der BAM bis 2019 bearbeitet wurden/werden und sich in den Rahmen der Forschungsstrategie einordnen.
Multiplexed encoding schemes of nano- and micrometer sized particles with fluorescent dyes or quantum dots (QDs) and their optical detection, are of increasing interest for applications in the life sciences, for example in flow cytometry. Almost all strategies utilizing fluorescence focus on spectrally distinguishable emission bands or colors and different intensity levels as fluorescence codes. The fluorescence parameter lifetime has been, however, barely exploited. In this work the goal is to perform multiplexing with encoding fluorophores with different fluorescence lifetimes (LTs). In comparison to the spectral multiplexing strategies this has the advantage, that the different fluorescence LT codes can be measured with the excitation and emission wavelength, thus reducing instrument costs. Moreover, LTs should not depend on emitter concentration. Unlike organic dyes, the LTs of which are typically < 10 ns, the fluorescence LTs of ternary semiconductor QDs that represent a “green” alternative to conventional Cd-containing QDs are in the range of several hundred ns, independent of oxygen concentration, and can be tuned to a certain extent by chemical composition and surface chemistry. This present a time region that can be barely covered by other emitters that have either much shorter or longer lifetimes. In this project, different encoding strategies will be assessed and the encoded particles will be then used for fluorescence assays for the analysis of several targets in parallel. Therefor the encoded particles will be functionalized with different target-specific bioligands and read out with a specifically designed flow cytometer enabling time-resolved fluorescence detection. With this instrument, the particles will be discriminated by their fluorescence LTs In one detection channel while the analytes will be quantified by fluorescence labels in a second channel in the intensity domain.
Metal oxide/graphene photocatalysts have been attracting considerable attention in solving environmental pollution problems because of the limitations of the semiconductor-based photocatalysts. In this study, highly efficient and inexpensive zinc oxide (ZnO) nanoparticles with three different morphologies, such as nanospheres, nanodisks, and nanorods, anchored on reduced graphene oxide (RGO) were synthesized in solvent mixtures with different ethanol to water ratios. Among the three morphologies, the nanospherical ZnO/RGO (sZG) Composite exhibited the highest methylene blue (MB) and rhodamine B removal efficiencies at 99% and 98%, respectively, after only 60 min under low-power (40 W) ultraviolet irradiation at a low catalyst loading of 0.1 g L−1. This nanocomposite also showed excellent photocatalytic stability under UV irradiation, retaining 96% Efficiency even after 15 cycles of MB degradation. Moreover, the sZG composite exhibited a high MB degradation Efficiency of approximately 99% after 100 min at a low catalyst loading of 0.2 g L−1 under solar light illumination. The
excellent photocatalytic performance and high stability of this low-cost nanospherical ZnO/RGO Composite exemplarily highlights the potential of sustainable next-generation photocatalysis for treating wastewater containing organic pollutants.
Photon upconversion nanomaterials have a wide range of applications, including biosensing and deep-tissue imaging. Their typically very weak and narrow absorption bands together with their size dependent luminescence efficiency can limit their application potential. This has been addressed by increasingly sophisticated core-shell particle architectures including the sensitization with organic dyes that strongly absorb in the near infrared (NIR). In this work, we present a simple water-dispersible micellar system that features energy transfer from the novel NIR excitable dye, 1859 SL with a high molar absorption coefficient and a moderate fluorescence quantum yield to oleate-capped NaYF4:20%Yb(III), 2%Er(III) upconversion nanoparticles (UCNP) upon 808 nm excitation. The micelles were formed using the surfactants Pluronic F-127 and Tween 80 to produce a hydrophilic dye-UCNP system. Successful energy transfer from the dye to the UCNP could be confirmed by emission measurements that revealed the occurrence of upconversion emission upon excitation at 808 nm and an enhancement of the green Er(III) emission compared to direct Er(III) excitation at 808 nm.
Relative and Absolute Methods for Measuring Photoluminescence Quantum Yields of UV/vis/NIR Emitters
(2019)
One of the key spectroscopic performance parameters of molecular and particulate emitters is the photoluminescence quantum yield (PL QY) that provides a direct measure for the number of emitted per absorbed photons. This triggered the interest in methods suitable for measuring this property for emitters in various environments in the UV/vis/NIR and above 1000 nm as well as on the ensemble and single emitter level. Moreover, for nonlinear emitters like lanthanide-based upconversion nanocrystals methods including instrumentation for power density-dependent PL QY studies are required.
An overview of the research activities in Division Biophotonics of BAM is given and suitable relative and absolute methods for the deter-mination of PL QY of organic dyes and different types of application-relevant nanomaterials in dispersion and in the solid state are presen-ted. This covers also the design and calibration of integrating sphere setups, achievable uncertainties, and candidates for PL QY reference materials.
Aldehyde moieties on 2D-supports or microand nanoparticles can function as anchor groups for the attachment of biomolecules or as reversible binding sites for proteins on cell surfaces. The use of aldehyde-based materials in bioanalytical and medical settings calls for reliable methods to detect and quantify this functionality. We report here on a versatile concept to quantify the accessible aldehyde moieties on particle surfaces through the specific binding and subsequent release of small reporter molecules such as fluorescent dyes and nonfluorescent chromophores utilizing acylhydrazone formation as a reversible covalent labeling strategy. This is representatively demonstrated for a set of polymer microparticles with different aldehyde labeling densities. Excess reporter molecules can be easily removed by washing, eliminating inaccuracies caused by unspecific adsorption to hydrophobic surfaces. Cleavage of hydrazones at acidic pH assisted by a carbonyl trap releases the fluorescent reporters rapidly and quasi-quantitatively and allows for their fluorometric detection at low concentration. Importantly, this strategy separates the signal-generating molecules from the bead surface. This circumvents common issues associated with light scattering and signal distortions that are caused by binding-induced changes in reporter fluorescence as well as quenching dye−
dye interactions on crowded particle surfaces. In addition, we demonstrate that the release of a nonfluorescent chromophore via disulfide cleavage and subsequent quantification by absorption spectroscopy gives comparable results, verifying that both assays
are capable of rapid and sensitive quantification of aldehydes on microbead surfaces. These strategies enable a quantitative
comparison of bead batches with different functionalization densities, and a qualitative prediction of their coupling efficiencies in bioconjugations, as demonstrated in reductive amination reactions with Streptavidin.
The project ProMoAM is presented. The goal of the project is to evaluate which NDT techniques or combination of techniques is suited for in-situ quality assurance in additive manufacturing of metals. To this end, also 3d-data fusion and visualization techniques are applied. Additional ex-situ NDT-techniques are used as references for defect detection and quantification. Feasability studies for NDT-techniques that are presently not applicable for in-situ use are performed as well.
The presentation gives a brief overview of the whole project and the different involved NDT-techniques.
Extracellular vesicles (EV) are cell-derived particles in body fluids, which have excellent potential as next-generation biomarkers. The exploitation of EV requires reliable measurements, which is currently very difficult, as most EV are smaller than 200 nm. At present, flow cytometry (FCM) is the most appropriate technique for EV analysis in biological samples, as FCM is readily available in many clinical laboratories and allows to identify cell-specific EV at high throughput. However, due to technical variations between different FCM instruments, EV concentration measurements are currently not well comparable between most laboratories. Therefore, EV reference materials and standardized reference methods are urgently needed to calibrate flow rate, light scattering intensity, and fluorescence intensity of FCM in the sub-micrometer size range. This requires a better matching of the optical properties of calibration beads and EV as can be realized with current polystyrene calibration beads.
The EMPIR project 18HLT01 “MetVes II” aims to develop synthetic reference materials and traceable measurement methods to standardize EV measurements. The reference materials should resemble EV properties, so that calibrations are reliable and do not require a change of acquisition settings. Hence, the reference materials should contain particles with a traceable number concentration in the range of 109–1012 particles/mL to calibrate flow rate, a traceable size with discrete diameters between 50–1000 nm and a refractive index (RI) in the range of 1.37–1.42 to calibrate scattering intensity, and a traceable fluorescence intensity between 100–100,000 molecules of equivalent soluble fluorochromes (MESF). At BAM, various approaches to prepare such low-RI nanometer-sized reference materials will be studied, preliminary results of the primary characterization of these candidate reference particles will be presented, and possible applications besides FCM-based EV detection will be outlined.