Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Dokumenttyp
Sprache
- Englisch (8) (entfernen)
Schlagworte
- Strengthening (3)
- Polyester fabric strips (2)
- Rammed earth (2)
- Shear-compression tests (2)
- Adhesion (1)
- Building Materials (1)
- Cob (1)
- Compression behavior (1)
- Cracks grouting (1)
- Diagonal compression test (1)
Organisationseinheit der BAM
Wild bees are important pollinators for agricultural crops and solitary species such as Osmia bicornis are particularly suitable for pollination management. Wild bees share floral resources with managed honey bees and may be exposed to emerging infectious diseases. Although studies have explored the prevalence of pathogens in solitary wild bee species, data regarding the impact of pathogens on solitary bee health are lacking.
We carried out experiments examining whether the solitary bee species O. bicornis is susceptible to infection with the emerging pathogen The results obtained indicate that N. ceranae may be able to infect O. bicornis but its impact on host fitness is negligible: survival rates did not differ between Control and inoculated bees, although male survival was marginally lower after infection. To explore the possible field-relevance of our findings, we collected wild bees near an infected and a non-infected hive and showed that N. ceranae was shared between managed and wild bees, although only the in presence of infected honey bees.
The findings of the present study show that O. bicornis is susceptible to pathogen spillover and could act as a potential reservoir host for N. ceranae in pollinator networks. Additional studies on this species incorporating sublethal effects, multiple infections and other interacting stressors are warranted.
The aim of this paper is to implement a numerical model to reproduce the nonlinear behavior of cob walls under shear loading.
Axial compression, pull-off, and diagonal compression tests were carried out to derive the mechanical parameters. In addition, the stressstrain relationships, the nonlinear behavior, and the failure modes were defined. The experimental results were then used to calibrate a finiteelement model. The material behavior was simulated through a macromodeling approach adopting the total strain rotating crack model.
A sensitivity analysis was conducted to assess the effects of varying the parameters with higher uncertainty on the structural behavior.
The numerical model achieved good correspondence with the experimental results in terms of simulation of the shear stress–shear strain relationship and of damage pattern.
This study analyses the mechanical behaviour under pseudo-dynamic loading of structural elements built in rammed earth and strengthened with polyester fabric strips. This strengthening technique was developed to exploit the strength potential of rammed earth and to solve its lack of tensile strength. For this reason, in-plane cyclic tests were carried out to investigate the shear behaviour of unstrengthened and strengthened walls. The strengthening technique requires low-tech equipment and workmanship, uses readily available, not expensive and industrially standardised materials. The experimental results were analysed in terms of stiffness degradation, energy dissipation capacity and equivalent viscous damping. Although the unstrengthened and strengthened walls confirmed a limited ductile behaviour, the findings confirm that the strengthening contributes to limit the spread of the diagonal cracks and provide an increase of strength in terms of horizontal load and displacement capacity.
An experimental investigation was carried out to study the in-plane shear behaviour of rammed earth structural elements strengthened with polyester fabric strips. The original idea for the retrofitting with polyester fabric strips was to introduce a vertical element for walls in order to take up horizontal loads resulting in a shear response of the building element. It has to be considered that vertical slits into the walls for fixing the strips are points of weakness and have to be mitigated by the adhesive. In this case a base coat mortar was employed. Strengthened elements were tested to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. As part of the study results of a testing campaign of unstrengthened structural elements were considered. Strengthened elements were tested in diagonal compression/shear and cyclic shear-compression. A unique reinforcement orientation was used. The results of these tests are presented in this paper and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective under cyclic shear-compression tests, with increase in load and displacement capacity observed. Under diagonal compression the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips.
The purpose of this paper is to numerically simulate the in-plane behaviour of rammed earth walls under cyclic shear-compression tests. The experimental testing allowed obtaining the maximum horizontal loads, the displacement capacity and the level of non-linear behaviour of the respective loaddisplacement relationships as well as the failure modes. The calibration of the numerical model (finite element method) was carried out based on the experimental results. Within this framework, a micromodelling approach was considered. The behaviour of the rammed earth material was simulated using a total strain rotating crack model. A Mohr-Coulomb failure criterion was used to reproduce the behaviour of the interfaces between the layers.
Although the numerical results achieved a satisfactory agreement with the experimental results a sensitivity analysis of the parameters involved was performed. The sensitivity analysis aimed at determining which parameters of the model have a significant impact in the model’s results. As expected the sensitivity analysis pointed out that the sliding failure occurrence is mainly influenced by two parameters of the interface elements: the interface tensile strength fit and the friction angle u. Moreover the cohesion c and the layers thickness showed a limited effect on the shear behaviour. It should be noted that the results mentioned above are related to the cases where a significant level of vertical compressive stress r is employed.
The study presents the results from the development of a grouting material based on hydrated lime with addition of pozzolana, which is referred to as hydraulic lime, suitable for the repair of cracks in a variety of earthen building techniques. The goal was to develop a material also compatible with earthen structures exposed to dynamic loads. The grouting mortar was designed to be adaptable in strength properties and at the same time to have sufficient robustness for preparation and use on the construction site.
Results showed a satisfactory performance of the grout concerning fresh and hardened mortar properties as well as injectability.
In-plane shear behaviour of earthen materials panels strengthened with polyester fabric strips
(2016)
An experimental investigation was carried out to study the in-plane shear behaviour of earthen material Panels strengthened with polyester fabric strips. Strengthened panels were developed to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. Three earthen materials were considered: cob, earth block masonry (EBM) and rammed earth (RE). As first approach the strengthening configuration, based on different adhesive materials, was tested only for cob panels. As part of the study the results of a big testing campaign of unstrengthened Panels were considered. Seven strengthened panels were tested in diagonal compression/shear.A unique reinforcement orientation was used. The results of these tests are presented in this paper, and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective in EBM panels, with increase in strength and ductility observed. In RE and cob panels the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips. Instead, in EBM it was likely that the vertical reinforcement acted in tension to restrain shear induced dilation and to restrain sliding.
The repair of earthen structures is not an easy task. Earth as a construction material has comparatively weak mechanical properties. It is also susceptible towards liquid water, were it can lose cohesion very quickly if certain moisture contents are exceeded. Repair concepts of structures built with such materials are therefore challenging. Historical earthen structures often exhibit damages in form of extensive cracking, which may have been caused by static or dynamic loads. Frequently these cracks are insufficiently or inappropriately repaired because of lack of knowledge and / or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage. Grouting materials require additional specifications such as compatible strengths and Young’s modulus as well as good adhesion to the earthen substrates. In addition, grouts have to be sufficiently flowable to fill small cracks and voids without segregation or bleeding. Therefore, the rheological behaviour has to be well understood and controlled to gain the desired effects.
The repair of cracks in earthen buildings is traditionally done by stuffing manually mortar into the gap. Naturally, this method is only usable for cracks with large widths. Another disadvantage is that cracks going through thicker walls cannot be completely reached by the tools used for stuffing the mortar into the crack. Lime based grouts for earthen materials were usually used for re-attachment of plasters but less for structural reasons. Due to the nature of earthen materials grouts based on formulated or hydraulic lime (according to the definition in EN 459-1) have to meet considerable demands on a variety of properties, which are related to compatibility, durability and in particular to the ability of being injected. The goal of this study was to create a grout, which can be used to re-establish structural continuity in cracked earthen masonry or other massive earth walls (rammed earth and cob) with the focus on grouting cracks. The grout material was based on hydrated lime (calcium hydroxide) with additions of pozzolana and lime stone filler.