Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Dokumenttyp
Sprache
- Englisch (4) (entfernen)
Schlagworte
- Archaeology (1)
- Compressive strength (1)
- Computed tomography (1)
- Durability (1)
- Fibres (1)
- Functionalization (1)
- Historical earthen building (1)
- Hydrogarnet (1)
- Hydrothermal treatment (1)
- Hydroxylellestadite (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (2)
- 7.1 Baustoffe (2)
- 7.4 Baustofftechnologie (1)
Several studies show that thermal and hydrothermal treatment can further improve the excellent properties of UHPC in terms of mechanical strength and durability. While for the thermal treatment the increase in strength is attributed to an intensified pozzolanic and hydraulic reaction, for the hydrothermal treatment previous studies accredited it mostly to the formation of tobermorite. In the presented study thermal and hydrothermal treatment of UHPC samples was systematically varied and the phase formation analysed related to the strength development of a reference sample cured for 28 days in water. For the thermal treatment the results show that the strength increase depends on the protection against desiccation and can be ascribed to an improved pozzolanic reaction of the siliceous fillers. To achieve a significant enhancement of strength, a pre-storage time of few days and a long dwell time at elevated temperature/pressure are required. For the hydrothermal treatment already heating the specimens up to 185 °C in saturated steam followed by an immediate cooling leads to a substantial increase in compressive strength. Pre-storage time did not affect the result as far as a minimum of several hours is guaranteed. The improved performance is due to an increase in the pozzolanic and hydraulic reaction. Surprisingly, tobermorite was only found within a very thin layer at the surface of the sample, but not in the bulk. Sulphate and aluminium stemming from the decomposition of the ettringite are bound in the newly formed phases hydroxylellestadite and hydrogarnet.
The low tensile strength of cement-based materials can be improved by the addition of fibres. In a joint research project, an industrial partner designed special coatings for polymer and carbon fibres by integrating surfactants and hydrophilic compounds. Aim of the developed functionalization was to ensure an even coverage of the fibre surfaces and to anchor them chemically in the cement-based matrix. Task of the BAM was to quantify the effect of the improved bond. In a first step a workable mortar adjusted to the strength of the tested fibres was developed and the fibre distribution assessed by light microscopy and computed tomography. To test the new coating for its efficiency to prevent cracking during hardening and to improve the loadbearing behaviour new test setups were developed or existing methods were adjusted.
The experiments showed that the functionalization leads to a reduction of the crack area measured after the exposure of the wet mortar to strong drying conditions in the wind channel. Regarding the Efficiency to mitigate shrinkage cracks the functionalisation turned out to be more efficient for fibres made from polyacrylonitrile (PAN) than for carbon fibres. An improvement of the tensile strength after cracking of the cementitious matrix could only be documented for the coated carbon fibres. It could be quantified, however, only in the three-point bending tests because the fibres turned out to be too brittle for the applied single fibre pull-through test.
This study assesses the structural vulnerability of part of a later medieval earthen building at
Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military
Orders. An inspection of its morphology and materials coupled with the results of an extensive
campaign of static monitoring reveals marked structural inhomogeneities, the product of more
than a thousand years of construction, failure, and repair from the 10th century to the present
day. Building materials are inappropriately juxtaposed, there are discontinuities between construction
phases and fundamental concerns remain over the long-term stability of the structure.
The current condition of the structure is mainly influenced by structural discontinuities introduced
at the time of construction, the unintended consequences of repair and modification and the
material decay that has affected the base of the rammed earth walls. The overall findings of the
static monitoring show that there is no related damage, variations in crack widths are related to
the building seasonal cycle. While static analysis is an essential prerequisite before a suitable
maintenance program can be fully defined, this study argues that no evaluation of the structural
behavior of any historic building can afford to ignore its archaeological “biography” of modification
and repair.
This study presents diagnostic techniques to assess the structural vulnerability of earthen buildings. Medieval structures at Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military Orders, provide a useful case study. After more than a thousand years of construction, failure and repair from the 10th century to the present day, Ambel preceptory today is characterised by marked inhomogeneities: construction materials and structural typologies are juxtaposed, with structural discontinuities at the interfaces between construction phases. This paper argues that, while static analysis is an essential prerequisite before a suitable maintenance program can be defined, no evaluation of the structural behaviour of any historic building can ignore an understanding of the building’s history.