Spezielle Themen
Filtern
Dokumenttyp
- Vortrag (4)
- Posterpräsentation (3)
- Zeitschriftenartikel (1)
Referierte Publikation
- nein (8)
Schlagworte
- Pyrotechnik (4)
- Aerosole (2)
- Fire (2)
- Missbräuchliche Verwendung (2)
- UKCA (2)
- BAM List (1)
- BAM-Liste (1)
- CE (1)
- CE-Kennzeichnung (1)
- Cryogenic Vessels (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (4)
Multilayer Insulation (MLI) is frequently used in vacuum conditions for the thermal insulation of cryogenic storage tanks. The severe consequences of the degradation of such materials in engulfing fire scenarios were recently evidenced by several large-scale experimental tests. In the present study, an innovative modelling approach was developed to assess the performance of heat transfer in polyester-based MLI materials for cryogenic applications under fire conditions. A specific layer-by-layer approach was integrated with an apparent kinetic thermal degradation model based on thermogravimetric analysis results. The modeling results provided a realistic simulation of the experimental data obtained by High-Temperature Thermal Vacuum Chamber tests reproducing fire exposure conditions. The model was then applied to assess the behavior of MLI systems for liquid hydrogen tanks in realistic fire scenarios. The results show that in intense fire scenarios degradation occurs rapidly, compromising the thermal insulation performances of the system within a few minutes.
Der Vortrag stellt die wesentlichen Inhalte sowie die wichtigsten Änderungen der TRGS 510 "Lagerung von Gefahrstoffen in ortsbeweglichen Behältern" vor.
Die TRGS 510 zeichnet sich durch ein gestuftes Maßnahmenkonzept in Abhängigkeit von der Art und Menge der gelagerten Gefahrstoffe aus. Folgende Maßnahmenstufen werden durch die TRGS 510 beschrieben:
1. Kleinmengen -> Allgemeine Maßnahmen
2. Überschreitung der Kleinmengen -> Lagerung im Lager
3. Überschreitung bestimmter Mengen für spezielle Gefahrstoffe -> Spezielle Maßnahmen
4. Verschiedene Gefahrstoffe und Lagerung im Lager erforderlich -> ggf. Getrenntlagerung und Separatlagerung
Das Poster beschreibt die aktuellen Aufgaben und Herausforderungen im Bereich der Konformitätsbewertung von zivilen Explosivstoffen und pyrotechnischen Gegenständen. Es wird dabei auf die Tätigkeiten der BAM als benannten Stelle in der EU (CE-System) und als approved body für das Vereinigte Königreich (UKCA-System) eingegangen.
The ongoing geo-political conflicts and the increasing need for the implementation of measures to improve the energetic system sustainability are increasing the importance of tanks for storing cryogenic fluids in the energy industry. The most common example of cryogenic tank applications is the transport of natural gas and hydrogen in their liquid form (LNG and LH2 respectively) for which, considering the same transport volume cryogenic storage ensures significantly higher transport capacities with respect storage based solely on overpressure.
A common feature of all cryogenic transported fluids is that their condition must be maintained minimizing heat leaks from the environment as much as possible. This is achieved by the implementation of thermal super Insulations (TSI) systems based on e. g. rock wool, perlites, microspheres, multilayer insulations (MLI), and vacuum which have proven to be effective in applications. However, due to the relatively short period of use in some applications, the small number of documented incidents, and the still few investigations carried out in the field, the exploitation of such systems in the cryogenic fluids transport sector still suffers from insufficient knowledge about the course and consequences of incidents. Accidents involving collisions, fires, and their combination are quite common in the transportation sector and may generate extraordinary loads on the tank and its insulation system, eventually leading to tank failure.
The present study focuses on the behavior of TSI systems in tanks when it is exposed to an external heat source representative of a hydrocarbon fire scenario. This may cause an increase of the heat flux into a tank by several orders of magnitude with respect to normal design conditions, thus inducing severe and in the TSI, causing the rapid release of flammable gas and even resulting in a Boiling Liquide Expanding Vapour Explosion (BLEVE).
To study such scenarios a test rig was developed at BAM that allows testing of TSI at industrial conditions and enables subsequent analysis of TSI samples. This test rig considers the typical double-walled design of tanks for cryogenic fluids with vacuum and an additional insulating material in the interspace. Adjustable electrical heating elements simulate the fire on one side of the double wall. This process allows the implementation of repeatable heat loads of up to 100 kW/m². The other side of the double wall is represented by a fluid-supported heat exchanger, which allows the simulation of cold or cryogenic conditions in the test rig, and to determine the heat flux transmitted through the double wall. Thus, the test rig allows thermal loading and performance analysis of TSI samples at the same time.
In the presentation, the results of diverse tested TSI systems will be presented and discussed. As a result of this study, the list of advantages and disadvantages for the choice of tested TSI expands. Within the test, all samples degraded as a consequence of a hydrocarbon fire-orientated thermal load. Strong differences in the behavior of the tested TSI systems over temperature, location, and time were observed. Additionally, the tested MLI insulations were significantly more resistant to their base materials. These results are relevant for the design, the definition of national and international regulations, the Risk assessment, and the development of safety concepts for cryogenic tanks.
Das Poster beschreibt die Ergebnisse von Messungen zur Freisetzung von Aerosolen beim Abbrand pyrotechnischer Gegenstände. Vor dem Hintergrund einer missbräuchlichen Verwendung (wie etwa in Fußballstadien) wird auf die speziellen Gefährdungen hingewiesen. Freigesetzte Partikel haben Größenbereiche von deutlich kleiner 100 nm und sind damit besonders alveolengängig.
Aerosolemissionen ausgewählter Pyrotechnik - Gefährdungsabschätzung bei missbräuchlicher Verwendung
(2024)
Der Vortrag beschreibt die Ergebnisse von Messungen zur Freisetzung von Aerosolen beim Abbrand pyrotechnischer Gegenstände. Vor dem Hintergrund einer missbräuchlichen Verwendung (wie etwa in Fußballstadien) wird auf die speziellen Gefährdungen hingewiesen. Freigesetzte Partikel haben Größenbereiche von deutlich kleiner 100 nm und sind damit besonders alveolengängig.