Analytische Chemie
Filtern
Erscheinungsjahr
- 2017 (193) (entfernen)
Dokumenttyp
- Posterpräsentation (193) (entfernen)
Sprache
- Englisch (169)
- Deutsch (23)
- Mehrsprachig (1)
Schlagworte
- Nanoparticles (14)
- Online NMR spectroscopy (10)
- XPS (9)
- CONSENS (8)
- In situ (7)
- LIBS (7)
- Nanoparticle (7)
- Fluorescence (6)
- Online NMR Spectroscopy (6)
- Process analytical technology (6)
- SEM/EDX (6)
- Thermoresponsive polymers (6)
- Mechanochemistry (5)
- Process Monitoring (5)
- ToF-SIMS (5)
- Boden (4)
- DNA (4)
- Electrochemistry (4)
- Indirect Hard Modeling (4)
- Knoevenagel condensation (4)
- NEXAFS (4)
- Nährstoffe (4)
- Process control (4)
- SEM (4)
- Bridge monitoring (3)
- C-C coupling (3)
- Dosimetry (3)
- Electrospray deposition (3)
- Flourescence (3)
- Functionalization (3)
- Graphene (3)
- Graphite furnace (3)
- High-Resolution Continuum Source Molecular Absorption Spectrometry (3)
- Imaging (3)
- Immunoassay (3)
- Indirect hard modeling (3)
- Isotopic shift (3)
- LA-ICP-MS (3)
- Localization of gas sources (3)
- MALDI-TOF MS (3)
- Mobile Robot Olfaction (3)
- Mycotoxin (3)
- PCA (3)
- Pollen (3)
- Reaction monitoring (3)
- SAXS (3)
- SMASH (3)
- Soil (3)
- Spectral modeling (3)
- TEM (3)
- Tomographic reconstruction of gas plumes (3)
- Tunable Diode Laser Absorption Spectroscopy (TDLAS) (3)
- Upconversion (3)
- XRD (3)
- Zerstörungsfreie Prüfung (3)
- Additive manufacturing (2)
- Air quality monitoring (2)
- Aktive Thermografie (2)
- Ammonia gas sensor (2)
- Analyse (2)
- Auger Electron Spectroscopy (2)
- Bead-based assay (2)
- Biofilms (2)
- Boron isotopes (2)
- Catalysis (2)
- Cement (2)
- Chemometrics (2)
- Click chemistry (2)
- Concrete (2)
- Conductive carbon tape (2)
- Core-shell nanoparticles (2)
- Core-shell particles (2)
- Data analysis (2)
- Elastic wave velocity (2)
- Electron microscopy (2)
- Flow cytometry (2)
- Fluorine (2)
- Food (2)
- HR-CS-MAS (2)
- Hepcidin-25 (2)
- Intercalibration (2)
- Isotope ratio (2)
- Isotope reference material (2)
- LC-MS/MS (2)
- Laser ablation (2)
- Mass spectrometry (2)
- Materialcharakterisierung (2)
- Microdosimetry (2)
- Molecular absorption (2)
- Multivariat (2)
- Mycotoxins (2)
- Nanomaterial classification (2)
- Nanoplatelets (2)
- Natural Zeolite Clinoptilolite (2)
- Online reaction monitoring (2)
- Perovskite (2)
- Process Analytical Technology (2)
- Prüfung (2)
- Quantum dot (2)
- RFA (2)
- RFID sensors (2)
- Radiation damage (2)
- Reinheitsgradbestimmung (2)
- Resonant mass measurement (2)
- Reverse glass painting (2)
- Rotaxane (2)
- Semiconductor (2)
- Sensors in concrete (2)
- Silver nanoparticles (2)
- Single particle spectroscopy (2)
- Solar cells (2)
- Spectroscopy (2)
- Standard gas generator (2)
- Superplasticizers (2)
- Surface analysis (2)
- Thin films (2)
- Titania (2)
- UAV-REGAS (2)
- Ultraschall (2)
- Ultraschalltauchtechnik (2)
- Wirbelstromprüfung (2)
- X-ray refraction (2)
- XRF (2)
- 3-axis gimbal (1)
- 3D (1)
- 3D High-temperatue shape screening (1)
- 3D-Printing (1)
- 87Sr/86Sr (1)
- AES (1)
- Ablaufdiagramme (1)
- Absolute flourometry (1)
- Acrylamide based polymers (1)
- Active thermography (1)
- Additive Fertigung (1)
- Additive Manufacturing (1)
- Adsorbentien (1)
- Adsorption (1)
- Aerial platform (1)
- Aerial systems (1)
- Agglomeration (1)
- Agriculture (1)
- Alginate (1)
- Alkali-silica-reaction (ASR) (1)
- Alkaline earth metal (1)
- Aluminum (1)
- Ambient ionization (1)
- Ambient noise (1)
- Ammonia (1)
- Analytical method (1)
- Annealing study (1)
- Anthropogenic markers (1)
- Antibody (1)
- Artificial digestion (1)
- Auger electron spectroscopy (1)
- BET (1)
- BFR (1)
- Bacterial Extracellular Electron Transfer Mechanisms (1)
- Bead based assay (1)
- Beton (1)
- Beton Ultraschall Monitoring (1)
- Biocorrosion (1)
- Bioimaging (1)
- Biomolecules (1)
- Boron monohydride (1)
- Brown-rot fungi (1)
- C Kedge NEXAFS (1)
- CFK (1)
- CO2 assisted impregnation (1)
- CO2 reduction (1)
- Cable-suspended parallel manipulator (1)
- Calcined clay (1)
- Capsules (1)
- Carboxy and amin (1)
- CdSe (1)
- Cearmics (1)
- Cell (1)
- Cellular uptake (1)
- Cement hydration (1)
- Certified reference materials (1)
- Chemical reaction (1)
- Chlorpyrifos (1)
- Citrinin (1)
- Coating (1)
- Cocrystal (1)
- Coda wave interferometry (1)
- Composites (1)
- Coordination polymer (1)
- Core-shell architecture (1)
- Core/Shell/Shell (1)
- Core/shell/shell (1)
- Corosion (1)
- Coulometric sensors (1)
- Crack detection (1)
- Cracks (1)
- Crystallization (1)
- Cyclohexane (1)
- Damage (1)
- Data Analysis (1)
- Data processig (1)
- Delta values (1)
- Depth profiling (1)
- Depth-profiling (1)
- Direct fluorine-metal bond (1)
- Direct loop control (1)
- Discotic Liquid Crystals (1)
- Dispersive (1)
- Doping study (1)
- Dyes (1)
- EC definition of a nanomaterial (1)
- EC definition of nanomaterial (1)
- Electrochemical synthesis (1)
- Electrodeposited Ni - coatings (1)
- Electron irradiation (1)
- Electron micrsocopy (1)
- Electronic nose (1)
- Embedded sensors (1)
- Embedded transducers (1)
- Emerging pollutants (1)
- Emerging technologies (1)
- Emissions testing (1)
- Energy resolved XPS (1)
- Environment (1)
- Environment monitoring and management (1)
- Environmental analysis (1)
- Epitope analysis (1)
- Er(III) (1)
- EuroPACT (1)
- Explosion Safety (1)
- FTIR (1)
- FeSnOx (1)
- Ferroelektret (1)
- Fertility management (1)
- Field Integration (1)
- Field robots (1)
- Flow cell (1)
- Flow-cytometry (1)
- Flowcytometry (1)
- Fluorescence materials (1)
- Fluorescence reference materials (1)
- Fluorescence sensors (1)
- Fluoride (1)
- Fontainebleau Sandstein (1)
- Food safety (1)
- Fundamente (1)
- Gas detection (1)
- Gas metrology (1)
- Gas sensing (1)
- Gas sensor (1)
- Gas sensors (1)
- Gas standard generator (1)
- Gassensing (1)
- Geant4 (1)
- Glass composition (1)
- Glass conservation (1)
- Glass-based fluorescence standard (1)
- Graphene 2D nanomaterial (1)
- Grundwasser (1)
- Haftfestigkeit (1)
- Hydride (1)
- Hydroformylation (1)
- Hydrogenation (1)
- Hydroxyl radicals (1)
- ICP-MS (1)
- Iisotope reference materials (1)
- Illite (1)
- Immobilization (1)
- Impuls-Thermografie (1)
- In-situ measurement (1)
- InPROMPT (1)
- Industrie 4.0 (1)
- Inhibition of HSV virus (1)
- Ink (1)
- Instrumented indentation testing (1)
- Integrating sphere spectroscopy (1)
- Interferometry (1)
- Iron biomarker (1)
- Isotope fractionation (1)
- Isotopes (1)
- Kaolinite (1)
- Keramikdurchflusszelle (1)
- KonSens (1)
- LC-MS/MS quantification (1)
- LC/MS (1)
- LCST (1)
- LEE (1)
- Labeling (1)
- Laser induced plasma (1)
- Laser profilometry (1)
- Laser-spark (1)
- Layer analysis (1)
- Layer analytics (1)
- Life sciences (1)
- Lifetime (1)
- Lifetime encoding (1)
- Line prediction (1)
- Liquefied petroleum gas (1)
- Lock-in-Thermografie (1)
- Long-term requirements (1)
- Low-Field NMR spectroscopy (1)
- Luftultraschall (1)
- Luminescence (1)
- MVA (1)
- Magnesium delta scale (1)
- Magnesium delta value (1)
- Magnesium isotope (1)
- Magnesium isotope ratio (1)
- Magnesium stable isotopes (1)
- Magnetostrictive actuator layer (1)
- Magnetostrictive layer (1)
- Magnetron sputtering (1)
- Malodour detection (1)
- Manuscript (1)
- Mapping (1)
- Mass Spectrometry (1)
- Matrix (1)
- Mechanochemical syntheses (1)
- Medieval glass composition (1)
- Medieval stained glass (1)
- Mehr-Proben-Kleben (MSB) (1)
- Mehr-Proben-Prüfen (CAT) (1)
- Memory effect (1)
- Metal hydrides (1)
- Metal organic frameworks (1)
- Metal phosphonate (1)
- Metrology (1)
- Micro-XRF (1)
- Micro-heterogeneity (1)
- Microbiological investigation (1)
- Microbiology (1)
- Microwave synthesis (1)
- Milling (1)
- Mini-plant (1)
- Miniaturized sensor device (1)
- Minitaurized sensor device (1)
- Mobile robot olfaction (1)
- Mobile sensors (1)
- Modular production plants (1)
- Modularised production (1)
- Moisture monitoring (1)
- Molecular dynamic simulation (1)
- Monte-Carlo simulation (1)
- Multi sensor device (1)
- Multi-element (1)
- Multicopter (1)
- Multivariate (1)
- NAP-XPS (1)
- NBT (1)
- NBT-Piezoceramics (1)
- NIR (1)
- NSO-Heterocyclen (1)
- Nanocluster (1)
- Nanomaterial classfication (1)
- Nanoparticles separation capillary electrophoresis asymmetrcial flow field flow fractionation (1)
- Natural zeolite clinoptilolite (1)
- Niederfeld-NMR (1)
- Niederfeld-NMR-Spektroskopie (1)
- Nominal properties (1)
- Normung (1)
- Nuclear Magnetic Resonance (1)
- Numerical methods (1)
- OH radicals (1)
- OPC UA (1)
- Olfaction (1)
- Online NMR Spektroskopie (1)
- Online monitoring (1)
- Online-NMR (1)
- Optical assays (1)
- Optical spectroscopy (1)
- Oxidation (1)
- PAT (1)
- PDMS (1)
- PLSR (1)
- PNA (1)
- PS (1)
- PTFE (1)
- PVD /ECD process (1)
- Pair distribution function analysis (1)
- Particle sizing techniques (1)
- Passive RFID (1)
- Passive Seismics (1)
- Passive seismics (1)
- Passive sensors (1)
- Passivsammler (1)
- Pattern recognition methods (1)
- Peptide losses (1)
- Perception and autonomy (1)
- Permeation method (1)
- Photoreaction (1)
- Photothermal (1)
- Piezoceramics (1)
- Pigments (1)
- Planung (1)
- Polymer blends (1)
- Polymer particles (1)
- Polymeric material (1)
- Polymers (1)
- Polymers based on 2,6-diaminopyridine (1)
- Polymorph (1)
- Polymorphism (1)
- Porosity (1)
- Powder (1)
- Precision (1)
- Prehydrated electrons (1)
- Process monitoring (1)
- Process sensors (1)
- Protein (1)
- Protein coating (1)
- Provenance (1)
- Prozessanalytik (1)
- Pump control (1)
- QD (1)
- Qualitative RM (1)
- Quantitative NMR spectroscopy (1)
- Quantum yield (1)
- Quantum yield standard (1)
- RFID based sensors (1)
- RNA detection (1)
- Radiation protection (1)
- Raman spectroscopy (1)
- Reduction 4-nitrophenol (1)
- Reference material (1)
- Residual stress (1)
- Response behavior (1)
- Reverse Time Migration (1)
- Riss (1)
- Rotaxanes (1)
- SAFT (1)
- SEM analysis (1)
- SEM-EDX (1)
- SERS (1)
- SP-ICP-MS (1)
- SPR (1)
- STXM (1)
- Sample preparation (1)
- Sample pretreatment (1)
- Sandstone (1)
- Schienenschleifen (1)
- Selective laser melting (1)
- Self-healing (1)
- Sensing (1)
- Sensor (1)
- Sensor requirements (1)
- Sensors (1)
- Shape (1)
- Shell (1)
- Silanization (1)
- Sintering (1)
- Site-specific (1)
- Size (1)
- Size effect (1)
- Small-angle scattering (1)
- Smart sensors (1)
- Smart structures (1)
- Smectite (1)
- Spectral Modeling (1)
- Spectral multiplexing (1)
- Spectroelectrochemical Techniques (1)
- Spektral Induzierte Polarisation (1)
- Standardization (1)
- Standards (1)
- Steel (1)
- Strain sensors (1)
- Strontiumfluoride (1)
- Structural health monitoring (1)
- Structured heating (1)
- Substrate effect (1)
- Substrates (1)
- Supplementary cementitious materials (1)
- Surface Enhanced Raman Spectroscopy (1)
- Surface Plasmon Resonance (1)
- Surface characterization (1)
- Surface chemistry (1)
- Surface groups (1)
- Surface modification (1)
- Synchrotron (1)
- Synchrotron X-ray diffraction (1)
- Synchrotron-XPS (1)
- Synthesis (1)
- Synthetic organic pigments (1)
- TEM grids (1)
- THz-time-domain spectroscopy (1)
- Tandem MS (1)
- Technological innovation (1)
- Tempeh (1)
- Temperature influence (1)
- Termites (1)
- Ternary quantum dot (1)
- Thermal cycling (1)
- Thermal wave (1)
- Thermografie (1)
- Thiol-ene coupling (1)
- TiO2 (1)
- Tiered approach (1)
- Time-gate Raman (1)
- Time-resolved (1)
- Tomography (1)
- Trace humidity measurement (1)
- Traceability (1)
- Transformation Products (1)
- Trophic level (1)
- UAV (1)
- UCST polymers (1)
- UCST-type copolymer (1)
- UCST-type polymers (1)
- USCT-type polymers (1)
- Ultraschallprüfung (1)
- Ultrasound (1)
- VOC (1)
- VSSA (1)
- Validation (1)
- Verbundfestigkeit (1)
- Volatile organic compounds (1)
- Wastewater (1)
- Water (1)
- Water transport (1)
- Wiedernutzung (1)
- X-ray computed tomography (CT) (1)
- XAFS (1)
- XANES (1)
- XRF analysis (1)
- Yb(III) (1)
- Zentrifugentechnologie (1)
- Zerstörungfreie Analytik (1)
- Zwitterionic graphene nanomaterials (1)
- low energy electrons (1)
- pH (1)
- µPAD (1)
Due to the demand of monitoring the water quality regarding emerging pollutants, such as drug residues, selective, high-throughput and multi-target analytical methods must be established. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affine and specific recognition of antibodies to target molecules. Batch-wise processing in microtiter plates allow the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex micro-bead based flow cytometric assay, which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core-silica-shell particles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica-shell creates a solid-support for the immunoassay: The target analytes, three drugs, carbamazepine, diclofenac and caffeine and the f ecal marker isolithocholic acid are covalently coupled to amino-groups on the surface via NHS-chemistry. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure. Finally, we could use SAFIA to assess the influent of treated and untreated waste water on the Douro river estuary in Portugal. The results of the analysis are comparable to ELISA. However, measurements could be carried out in 25% the time of analysis.
Coulometric sensors were tested in humidified synthetic air at various gas temperatures. Generated frost point temperature in the gas ranged from -30 °C to -60 °C and were measured by coulometric sensors and in addition by a calibrated dew point hygrometer. The gas temperatures, which were measured by a calibrated Pt100 sensor, were set to -20 °C, 0 °C, 23 °C, 40 °C, 50 °C, and 60 °C during the experiments. Empiric nonlinear functions were calculated between the humidity and the sensor signal. In comparison to the measured signals at 23 °C, the sensor signals were lower at the other gas temperatures. Measurements at 60 °C showed indistinct results due to a great signal noise. The response behavior of the sensors was similar at 23 °C, 40 °C and 50 °C. In contrast to that, the sensors reacted slowly at a gas temperature of -20 °C and 0 °C. In summary, with coulometric sensors it was possible to measure continuously trace humidity with an expanded uncertainty below 2 K.
Anemophilous plants produce pollen grains, which promote allergies. Therefore, pollen are monitored to provide a national information network. Their conventional identification and differentiation is performed by time-consuming microscopic examinations based on the genus-specific pollen morphology. A variety of spectroscopic and spectrometric approaches have been proposed to develop a fast and reliable pollen identification using specific molecular information. Amongst them, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) showed a high potential for the successful investigation of such complex biological samples. Specifically, it was illustrated that MALDI-MS imaging provides a powerful tool to identify pollen grains in pollen mixtures on the basis of ion intensity plots. More recently, the evaluation of the obtained peak patterns from pollen mass spectra with multivariate statistics enables a consistent and rapid identification of the taxonomic relationships. A novel application using conductive tape on the MALDI target simplifies sample preparation and enhanced the quality of the mass spectra. This led to a comprehensive analysis of the MS patterns, which is important when identifying pollen grains from different plant species in mixtures.
Here, we present further developments in MALDI-MS imaging of mixtures of pollen from different plant species. By combining conductive tape sample preparation with MALDI MSI and chemometric analysis, first promising results were obtained. In addition, we discuss the ability of partial least square regression (PLS-R) to identify pollen species based on independent reference spectra and present first results obtained with artificial pollen mixtures. These methods will be used in future online identification of pollen species in natural pollen mixtures.
Anemophilous plants produce pollen grains, which have to be monitored to provide a national information network for persons suffering from an allergy. The current conventional characterization and identification of pollen is performed by time-consuming microscopic examinations based on the genus-specific pollen shape and size. These examinations need proficient researchers, are not statistically validated, and additionally rely on relatively inaccurate observations of the pollination process.
A variety of spectroscopic and spectrometric approaches have been proposed to develop a fast and reliable pollen identification using specific molecular information. Amongst them, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was recently applied for the rapid investigation of such complex biological samples. The combination of obtained peak patterns from pollen mass spectra and multivariate statistic provide a powerful tool for identifying taxonomic relationships. A novel application based on the use of conductive carbon tape as MALDI target simplified the sample preparation and yielded enhanced the quality of the mass spectra. This led to a sufficient statistical analysis of the MS pattern, which is important when identify pollen grains in natural species mixtures.
Based on this approach, promising results could be obtained by MALDI-TOF MS imaging (MSI) of artificial pollen mixtures followed by multivariate analysis. Of special interest is here the determination of the detection limit (number of pollen grains). Therefore, different pollen grain compositions were investigated for quantitative profiling of each individual pollen species within these complex mixtures. Our results can be used to improve the taxonomic differentiation and identification of pollen species and might be useful for the development of a routine method to identify pollen based on imaging mass spectrometry.
Accurate measurements of stable isotope abundance ratio variations are often reported using artifact based delta-scales, which rely on suitable isotopic reference materials (iRM) for their realization. For example, variations in the 26Mg/24Mg isotope abundance ratio in natural systems are typically reported as delta26Mg values that represents the relative difference between the 26Mg/24Mg ratio measured in a sample relative to its measurement preferably in an iRM. In the past, such delta26Mg measurements were referenced to NIST SRM 980, the initial zero of the delta26Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. It was then replaced by a Mg solution (DSM3), the new zero of the delta26Mg scale. A potential replacement iRM for DSM3 has been developed, ERM-AE143. This iRM has also been measured for its absolute isotope amount ratios1,2 making it traceable to the SI.
The results of a delta26Mg intercomparison experiment include the Mg iRMs SRM 980, IRMM-009, ERM-AE143, AE144, AE145 standards DSM3 and Cambridge-1. The intercomparison involved 5 expert laboratories, consisting of 3 national metrological institutes (BAM, NIST, PTB) and 2 scientific research laboratories (GFZ Potsdam, UBremen).
The iRMs were measured relative to AE143 and cover a range of ≈5 ‰ in delta26Mg. IRMM-009 has the lowest delta26Mg value while DSM3 has the highest, spanning a range in values that covers natural Mg isotope variations. The 2SD reproducibilities of the individual values from the different laboratories range from 0.02 to 0.26 ‰. The mean delta26Mg values, calculated from the laboratory means however show 2SD reproducibilities varing between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for delta26Mg determinations.
1 JAAS, 2015, 31,179; 2JAAS, 2016, 31, 1440
In micro or nano particles development it is important to understand and control the particle structure, as it affects among other things the potential further surface functionalisation/modification possible.
This work shows the capability of resonant mass measurements (RMM) to measure the mass and density of micron sized particles. The technology utilizes a suspended MEMS microchannel resonator, through which individual particles transit across the resonator altering the resonant frequency, which is then detected using an optical-based method. Changes in frequency observed when a particle enters the microchannel resonator are proportional to the buoyant mass of the particle, and can be translated into mass, size or surface area. RMM therefore allows particle concentration to be determined as well as particle mass in a single measurement.
Furthermore, a method for estimating the density distribution of particles from RMM measurements has been developed. This uses the convolution of the buoyant mass distribution of the particles obtained when suspended in different fluids.
By combining the data from the density and mass determinations, small mass shifts arising from applying a coating to a particle can be estimated, and the resulting shell thicknesses calculated. These methods have been applied to silica coated and uncoated polystyrene latex particles.
RMM shows that it can be used to measure, and distinguish between, silica shell thicknesses that are in the order of 10 to 55 nanometres on hybrid micron-sized particles. RMM can also determine the shell density.
Polycrystalline Ni materials with grain sizes less than 100 nm (nano crystalline NC) and with grain sizes in the micrometer range (micro crystalline MC) in form of thin films have become important in many technologies due to their improved physical, chemical and mechanical properties. Usual the mechanical properties of such coatings are described by a Hardness value and a Young´s modulus measured by Instrumented Indentation Testing (IIT).The behavior of such coatings during indentation test is influenced by different size effects having their representative length scale – grain size, coating thickness, length that characterizes the depth dependence of the hardness (Indentation Size Effect ISE). To estimate realistic values for the intrinsic coating Hardness and Young´s modulus all size effects have to be considered.
For this work thin nano crystalline Ni – coatings (average grain size 30 nm) with thickness from 1 μm to 5 μm were electrodeposited on brass substrates. Indentation tests in the continuous stiffness measurement (CSM) mode were provided on as prepared Ni – coatings using a G200 Nanoindentation system (Fa. Keysight). For estimation of the intrinsic hardness of the coatings from composite hardness values calculated from the measured force –displacement curve using the Oliver & Pharr method, the model described by Z.S. Ma [1] was used.
It was found that the experimental data can be well described by the model. The fitted values for the intrinsic hardness and the fitting parameters will be given. The different values of intrinsic hardness and of length characterizing depth dependence of the hardness for different coating thickness are discussed as results of changes in the coating structure because of changes in deposition parameters.
[1] Z.S. Ma, Y.C. Zhou, S.G. Long, C. Lu: On the intrinsic hardness of a metallic film/substrate system: Indentation size and substrate effects. International Journal of Plasticity 34 (2012) 1-11.
This work is supported by European Metrology Program for Innovation and Research (EMPIR)
(JRP 14IND03 Strength – ABLE)
Self-assembly of TiO2 nanoparticles in multiple layers by layer-by-layer deposition has been selected of different deposition procedures usually applied for fabrication of TiO2 thin films with defined and homogeneous thickness on supports of interest for the large-scale applications. The substrates tested were: conductive (FTO) glass, silica glass and titanium alloy. The selected film fabrication technique consists of the deposition of alternating layers of oppositely charged, i.e. functionalized, TiO2 nanoparticle layers with wash steps in between. The controlled assembly of TiO2 nanoparticles on the supports surface requires both a proper functionalization of the supports to promote the adhesion of the TiO2 film to the substrates and proper functionalization of TiO2 nanoparticles to allow attachment to substrate and subsequent reaction between different NP layers. The current study focusses on the analytical control of the functionalization of the substrates with 3-Aminopropyltriethoxysilane (APTS) and glutaraldehyde (GA) by means of surface sensitive methods, XPS, Auger Electron Spectroscopy (AES) and ToF-SIMS. Chemical composition of surface of functionalized substrates shows differences in the degree and type of modification in dependence on substrate.
Manufacturing of new perovskite layered solar cells with constant high light conversion efficiency over time may be hampered by the loss of efficiency caused by structural and/or chemical alterations of the complex layered system. SEM/EDX combined with XPS were chosen as an appropriate methodical approach to characterize perovskite laboratory cells in depth and at surface, before and after light exposure. The layered perovskite system investigated here is based on glass covered with fluorine doped tin oxide (FTO), followed by thin films of TiO2, ZrO2 and a thick monolithic carbon. TiO2 film is subdivided into a dense layer covered by porous one constituted of nanoparticles (NPs) of truncated bipyramidal shape. This layered system serves as the matrix for the perovskite. EDX spectral maps on cross-sections of specimen have shown that Pb and I are distributed homogeneously throughout the porous layers C, ZrO2 and TiO2. SEM/EDX data show that 20 weeks of ambient daylight did not change significantly the indepth distribution of the elemental composition of Pb and I throughout the entire solar cell system. It was confirmed with EDX that NPs identified in high-resolution SEM micrographs contain mainly Pb and I, indicating these to be the perovskite crystals. However, a compositional and chemical altering began in the near-surface region of the outermost ~10 nm after 2 months of illumination which was observed with XPS.
The synthesis of TiO2 nanoplatelets with fluorine-containing reactants is carried out using Ti (IV) butoxide as precursor and concentrated HF as shape controller, the final product requires a working up in order to eliminate or at least to reduce the amount of residual fluorides, which is realized here by well-defined thermal treatment.
Qualitative investigation of the bulk elemental composition by means of EDX of TiO2 nanoparticles (NPs) has identified fluorine in case of the as-synthesized samples. EDX spectra of thermally treated products exhibit either a fluorine content close to the limit of detection. The latter holds also true for the reference sample, TiO2 NPs of bipyramidal shape and prepared by a different synthesis route. For differentiation whether fluorine is present in the bulk or at the surface of the TiO2 nanoplatelets, top-surface sensitive AES and ToF-SIMS has been applied. Secondary ions of fluorine are detected in ToF-SIMS spectra of all samples, but could be roughly quantified by measurement of same reference sample as for EDX, namely TiO2 nano-bipyramids. This revealed that the amount of fluorine within1 nm depth beneath the surface is reduced in the thermally treated specimen compared to the raw product down to a content about as low as in the reference sample. AES allows analyzing analysis of the first few nanometers from the top-surface of individual NPs by point analysis. An F KLL peak has been detected at the surface of samples of as-prepared TiO2 nanoplatelets under optimized measurement conditions, but was not detectable after their calcination, which is in agreement with ToF-SIMS results. Moreover, high resolution AES on single TiO2 nanoplatelets elucidated that the surface atomic layers surrounding the TiO2 nanopaltelet contain fluorides before thermal treatment of the NPs.
We report on the design, preparation and application of immobilized Oligonucleotides as biological sensors for dosimetry and protein activity. Oligonucleotides can be custom tailored in terms of sequence and length to the needs of the specific application. The preparation can be scaled from small lab-scales to higher output via spotting technology on various surfaces such as glass, silicon-dioxide or gold. They can be applied for the sensing of DNA-protein interaction and surface-plasmon resonance to detect the influence of cosolutes on the protein activity. This can be applied in the testing of pharmaceutical or cosmsetic applications and incorporated in microfluidic devices. Other important use cases are the usage in dosimetric application where the oligonucleotides are subjected to ionizing radiation. They can directly act as a sensor for biological damage which is detected and quantified by the subsequent hybridization of complementary strands who carry a fluorescence dye. The quantification can be performed by an array scanner or fluorescence microscope. Investigation on a molecular level can be performed with the AFM-IR technique. Applications are calibration of radiation sources and the investigation of interaction of ionizing radiation with biomolecules.
The damage caused by ionizing radiation to biomolecules, especially DNA, is the reason to treat cancer via radiation therapy. A better understanding of the molecular processes and the quantification of the various damaging mechanisms is the prerequisit to develope efficient therapies. Hereby the understanding of the processes involved in the damage to DNA are of key interest due to its central role in reproduction and mutation. Due to the high amount of water in biological tissue, most of the damage is caused by the secondary particles produced by the interaction of the IR with water. Thereby a multitude of species are produced, e.g. kinetic low energy electrons, prehydrated electrons, OH-radicals and ions. The quantification of the contribution to DNA damage of the various species is of interest. Here we present an experimental approach to disentangle their relative DNA strand break yield. Plasmid DNA is irradiated in water with electrons under the presence of different scavengers. With the presented method it will be possible to reveal the relative contributions of OH-radicals, low energy electrons and prehydrated electrons to the DNA single and double strand break yield.
The ambient air quality around residential areas is influenced by industrial objects, including industrial sewage, livestock farming and landfill sites. These sites are generating malodours or toxic gases involving degradation of ambient air quality, which may constitute a risk in human health if maximum emission limits are exceeded. Therefore, appropriate tools allowing detection of harmful or bad odorous, subsequently contributing to a reduction of odour nuisance are greatly needed. The aim of this study was to demonstrate the capability of an electronic nose E-nose to discriminate various gas samples collected from six different sites from the agglomeration of Meknès city corresponding to municipal landfill, in the city at 2 km of landfill, industrial estate wastewater, traffic road, and sheep breeding. The investigations were carried out with an E-nose system based on an array of six-commercial MQ sensors. Further, a pattern recognition technique known as Principal Component Analysis (PCA), Linear Discriminent Analysis (LDA), and Support Vector Machines (SVMs) was implemented to study the discrimination capability of the sensor array. PCA results demonstrate excellent discriminating ability of the dataset with a score of 99.47 %. Additionally, another measurement database containing 12 air atmospheric samples was projected on the previously built PCA model to check the stability of the E-nose. The LDA was applied to the same dataset and showed a good discrimination between the ambient air samples of the six sites. Furthermore, SVMs technique was also used to build a classifier and reached a score of 100 % success rate in the recognition of the analysed samples. The obtained results of six areas demonstrate the increasing interests and the applicability of E-noses for ambient air quality classification of six areas caused by emitted decomposed organic matters.
Evaluation of particle sizing techniques for implementation of the EC Definition of a nanomaterial
(2017)
Many techniques are available for measuring particle size distribution. For ideal materials (spherical particles, well dispersed) it is possible to evaluate the Performance of these methods. The performance of the analytical instrumentation for the purpose of classifying materials according to EC Definition is unknown. In this work the performance of commercially available particle sizing techniques on representative NanoDefine set of real-world testing materials (RTM) and quality control materials (QCM) for the implementation of the Definition is evaluated.
Electrospray ionization constitutes a promising deposition technique for high-resolution imaging. Particle distribution on TEM grids takes place homogeneously and no losses occur. Suspension must be appropriate (stabilizer may induce artefacts). ESI parameters need to be optimized for each material.
Volume specific surface area (VSSA) by BET: concept and demonstration on industrial materials
(2017)
Volume specific surface area (VSSA) as measured by BET constituites a simple and reliable solution to (most) powders. Porous, coated, polydisperse/multimodal materials are to be treated with care, i.e. doubled by analysis with electron microscopy or more advanced BET analysis (e.g. t-plot)for each material in part.
Qualitative reference materials (RM) cover a wide range of the overall RM market. Proficiency testing providers attract up to a thousand of participants in PT schemes purely oriented on qualitative results. The RM used for these kinds of PT are poorly regulated, nevertheless with a more and more general acceptance of accreditation in the field of RM production and PT provision, there is an ever increasing interest in assessing producers and providers according to rules already well accepted in the field of quantitative analysis.
The basic governing document, ISO 17034:2016, is written in a form that, at least for the overwhelming majority of requirements, may be applied to both qualitative and quantitative RM. However, problems remain. In particular, the expression of uncertainty of a purely qualitative result is still unresolved, and under discussion, the latter now lasting already dozens of years.
Some handles would be needed. In the poster, existing approaches and some pragmatic, new ways to tackle the problem are displayed and discussed.
A scanning transmission x-ray microscopy (STXM) based methodology is introduced for determining the dimensions (shell thickness, core and total diameter) of core-shell nanoparticles which exhibit a strong x-ray absorption contrast and a well-defined interface between core and shell material. A low radiation dosage during data acquisition and, therefore, less x-ray beam induced damage of the sample is achieved by recording STXM images only at two predetermined energies of maximum absorption contrast, instead of recording a stack of images across the whole absorption edge. A model core-shell nanoparticle, polytetrafluoroethylene (PTFE) cores with polystyrene (PS) shell, is used for demonstration. Near edge x-ray absorption fine structure (NEXAFS) spectroscopy confirms the significant difference in x-ray absorption behavior between PTFE and PS. Additionally, due to the insolubility of styrene in PTFE a well-defined interface between particle core and shell is expected. In order to validate the STXM results, both the naked PTFE cores as well as the complete core-shell nanoparticles are examined by scanning electron microscopy (SEM). The introduced STXM based methodology yields particle dimensions in good agreement with the SEM results (deviation equal or less than 10%) and provides additional information such as the position of the particle core which cannot be extracted from a SEM micrograph.
Seit dem Beginn der Anwendung der aktiven Thermografie für die zerstörungsfreie Prüfung werden für die optische Anregung zwei alternative Anregungstechniken eingesetzt: die Puls- oder Blitzthermografie und die Lock-in-Thermografie.
Bei der Puls-Thermografie ist der Anregungspuls wesentlich kürzer als die Zeit, die für die Wärmediffusion in das Bauteil hinein benötigt wird. Die Auswertung der erfassten Abkühlsequenzen wird zurzeit im Wesentlichen mit zwei Verfahren durchgeführt. Für die Auswertung im Zeitbereich werden verschiedene Auswertungsmodi des TSR-Verfahrens (TSR: thermal signal reconstruction) und Verfahren zur möglichst frühzeitigen Detektion des Intensitäts- oder Temperaturkontrastes der Fehlstellen herangezogen. Alternativ kann die Auswertung im Frequenzbereich nach dem Verfahren der Puls-Phasen-Thermografie (PPT) erfolgen. Dabei wird die Abkühlsequenz als Überlagerung vieler Einzelschwingungen betrachtet (Fouriersynthese). Die entsprechenden Phasenkontraste können unter bestimmten Umständen zur Abschätzung der Fehlstellentiefe genutzt werden.
Bei der Lock-in Anregung wird das zu untersuchende Prüfobjekt periodisch mit einer bestimmten Frequenz erwärmt und die Wärmestrahlung von der Oberfläche zeitgleich mit der Infrarotkamera erfasst. Für jede Anregungsfrequenz ist daher eine Einzelmessung erforderlich. Die Auswertung bezieht sich in den meisten Fällen allein auf die Berechnung des Phasen- und Amplitudenbildes bei der Anregungsfrequenz. Diese Berechnung kann bereits während der Messung (on-line) oder erst nach der Erfassung der Thermogrammsequenz (off-line) erfolgen.
Gemäß dem Superpositionsprinzip, das wegen des linearen Charakters der Wärmeleitungsgleichung für alle Lösungen der Differentialgleichung gilt, besteht Äquivalenz zwischen einer monofrequenten Anregung bei Lock-in-Thermografie und einer entsprechenden Komponente gleicher Frequenz bei der Puls-Thermografie. Daher sollten die Puls-Thermografie und die Lock-in-Thermografie in den Phasenbildern für die gleichen Fehlstellen die gleichen Phasenkontraste ergeben. Die experimentelle Bestätigung dieser Äquivalenz für unterschiedliche Fehlstellenarten ist der Schwerpunkt dieses Beitrages. Mögliche Gründe für Abweichungen werden benannt und sind Grundlage für weitere Diskussionen.
Da die Thermografie als zerstörungsfreies Prüfverfahren noch vergleichsweise neu in der Anwendung ist, beziehen sich die aktuell veröffentlichten und überarbeiteten Normen und Richtlinien im Wesentlichen auf die grundlegenden Prinzipien des Verfahrens und die verschiedenen Anregungs- und Auswertungstechniken, auf die Begriffe und auf die Gerätetechnik.
Die grundlegenden Normen zum Prinzip des Prüfverfahrens, zu den Geräten und zu den Begriffen wurden in 2016 grundlegend überarbeitet und als CEN-Normen neu veröffentlicht. Im Anschluss dazu wird in 2017 der überarbeitete Normentwurf zur aktiven Thermografie veröffentlicht. Mit der Bearbeitung einer europäischen Norm zur Laserthermografie wurde begonnen.
Auf nationaler Ebene werden zur Zeit Normen zu den verschiedenen Anregungstechniken erarbeitet. Anfang 2017 wurde der Normentwurf zur Impuls-Thermografie mit optischer Anregung veröffentlicht. Geplant sind weiterhin Entwurfsveröffentlichungen zur induktiv angeregten Thermografie sowie zur Lock-in-Thermografie mit optischer Anregung. Parallel dazu wurde die Überarbeitung der Norm zur Thermografischen Prüfung elektrischer Anlagen publiziert.
Mit der Richtlinie VDI/VDE 3511 Blatt 4 bis 4.4 gibt es ein anerkanntes Regelwerk für die rückführbare Temperaturmessung und Kalibrierung von Strahlungsthermometern, die bisher für Thermografiekameras fehlte. In 2016 wurde daher die VDI/VDE Richtlinie 5585 Blatt 1 zur messtechnischen Charakterisierung von Thermografiekameras als Entwurf veröffentlicht. In Bearbeitung ist momentan Blatt 2 zur Kalibrierung von Thermografiekameras mit dem Ziel, auch für Thermografiekameras anerkannte Regeln zur rückführbaren Temperaturmessung zu erstellen.
Im Beitrag werden die Anwendungsbereiche dieser Normen und Richtlinien vorgestellt und neue zukünftige Anwendungsbereiche in der Fertigung und Instandhaltung diskutiert.
Clinoptilolite is a natural, medium pore size zeolite. It contains a 2-deminsional pore system consisting of oxygen-8- membered and oxygen-10-membered rings. It is one of the most abundant natural zeolites. It is mainly used as ion exchanger and adsorbent for removal of toxic elements and compounds from the environment. Although clinoptilolite is microporous and can be acidified by ion exchange or acid treatment and a potential catalyst, reports on its application in catalysis are limited so far. This contribution deals with modification of a natural zeolite clinoptilolite, and the study of the influence of the textural and acidic properties on the catalytic performance in the acid catalyzed acetalization of bezaldehyde with butandiol-1,3 and the more demanding etherification of glycerol with t-butanol or isomerization of n-hexane. The samples were acidified by via ammonium-ion exchange followed by calcination and acid treatment. Samples were characterized by XRD regarding crystallinity and phase composition, FTIR, and N2-adsorption for porosity. The morphology was studied by TEM images. The acidity was studied by ammonia-TPD measurements and 1H solid state MAS NMR. Structure and structural changes caused by applied modifications were studied by 27Al- and 29Si MAS NMR measurements and TRAPDOR experiments as well as thermal analysis.
The studied natural zeolite tuff contained ca. 90 ma.-% of clinoptilolite. The ion exchange behavior was studied with ammonium nitrate solution and for comparison with HCl solution of similar concentration. The cation exchange was followed by AES. The activation temperature was varied between 400-600°C. The catalytic test was performed e.g. using ca. 0.2 g of the catalyst and ca.10g of the aldehyde or alcohol using toluene as solvent and under reflux. Reaction water was removed via a by-pass. The isomerization of n-hexane was performed in a fall stream reactor at elevated temperature at gas phase. Water vapour saturated air was passed over clinoptilolite samples at elevated temperature for different time.
The ion exchange experiments shows that ca 45% of the cations of clinoptilolite readily exchange with ammonium ions and protons supplied by acid treatment. However, exchange with the acid has a more severe impact on the clinoptilolite structure. More severe treatment times leads to a loss of activity in terms of acetal formation. Sample show all high conversions after 4 h of reaction, but show markedly differences after short reaction times. The presence of acidic protons of medium to strong strength is confirmed by ammonia-TPD and proton NMR measurements. The sample activation causes a partial dealumination as indicated by the appearance of 5- and 6-fold coordinated aluminum. Interestingly, the NMR results give first hints for a relation of the catalytic conversion with the amount of 5-fold coordinated aluminum. The results will be discussed in terms of a collaborative action of Brønsted acid sites and 5-fold coordinated aluminum.
Modified clinoptilpolite is highly active in acid catalyst acetalization of aldehydes, isomerization of n-hexane and etherification of glycerol with t-butanol. Acidic natural clinoptilolite catalysts prepared via ammonium exchange followed by calcination and acid treatment shows a positive influence on acidity and porosity. Modification creates hierarchical micro-nano porosity. The specific surface area varies between ca. 45 m2/g and 257 m2/g.
Volatile Organic Compounds (VOC) are ubiquitous in the indoor air, since they emit from materials used indoors. Investigations of these materials are mostly carried out in test chambers under controlled climatic conditions. Quality control of these test chamber measurements is important but there is a lack of commercially available homogenous reference materials as required for round robin tests or quality assurance of laboratories. The approach of the present study is the impregnation of a supporting material with VOC, which are reproducibly released in measurable chamber air concentrations under standardised test conditions. A polymer made of Thermoplastic Polyurethane (TPU) was chosen as carrier material. It was impregnated with the VOC trimethyl pentanediol isobutyrat (texanol).
We present the first spectroscopic study on a reverse glass painting form the classic modern period (1905-1955). Marianne Uhlenhuth’s painting “Ohne Titel, 1954” shows characteristics like experimental use of colorants and abstract compositions, which are well-established in classic modern art. Compared to stained glass, reverse glass paintings are viewed in reflected light, hence they reveal strong and intense colors. New inorganic pigments, development of synthetic organic pigments and the simultaneous supersession of well-known ancient colorants result in experimental works and remarkable pigment mixtures in this period of time. An in-situ, non-invasive approach was used to study the pigments and binding media. In-situ measurements were carried out using Raman spectroscopy (i-Raman®Plus, Bwtek Inc., 785 nm, 20× objective, resolution 4 cm-1), X-ray fluorescence (Tracer III-SD, Bruker AXS Microanalysis GmbH, 40 kV, 15 μA), VIS spectroscopy (SPM 100, Gretag-Imaging AG) and DRIFTS: Diffuse Reflection-Infrared-Fourier-Transform Spectroscopy (ExoScan, Agilent GmbH, 4000-650 cm-1, 256 scans, resolution 4cm-1). The pigments consist of inorganic as well as organic materials. Phthalocyanin green (PG7, colour index No. 74260), viridian and emerald green were used for the green areas. The yellow parts consist of chrome yellow and cadmium yellow. Pigment Yellow 1 (C.I. 11680) was used for the dark yellow/orange part. Red areas were characterized by the presence of cadmium and selenium (cadmium red) in the XRF spectrum. Ultramarine was detected in the blue parts. Concerning the violet color PR81 (bluish red, C.I. 45160:1) in mixture with PG7 (bluish green) were identified as main components. We want to outline that PR81 was rarely found in paintings. It was only recorded in the palettes of Lucio Fontana and Mary Cassatt before. The dark violet areas consist of Prussian blue and an unknown red (organic) colorant. Brown iron oxide was identified as the brown pigment. Bone black in mixture with black iron oxide were used as black materials and zinc white and titanium white as white pigments. XRF analysis of the metal color yields intense copper, zinc and nickel peaks (intensity ratio 3:3:1), which corresponds to “new silver” alloy. Barite and chalk are the fillers in this painting. Results of DRIFTS spectra show gum sometimes mixed with protein or oil (metal soaps) as binding media. The results point out that reverse glass paintings from the classic modern period are excellent examples to study the evolution of new pigments and their acceptance in artist’s palettes.
Tandem MS experiments allow the fast acquisition of spectral datasets with enormous size and unprecedented content of information. The most commonly used method is undoubtedly collision induced dissociation (CID). The relatively young technical adaptation of CID to modern day Orbitrap experiments needs a higher confinement voltage and has accordingly been named higher-energy collisional dissociation HCD. Despite the name the absolute value of transferred energy per collision in HCD is lower than in CID. Since for many proteins CID and HCD result in comparable fragmentation patterns the two techniques are often treated as interchangeable. This approach is, however, not without pitfalls as other classes of biomolecules often exhibit strongly pronounced fragmentation specificity. As an example, MS/MS experiments on several 4-mer oligonucleotides were conducted employing both collision methods and the results were thoroughly compared. It is apparent that not only the total fragment yield but also the identity of the observed fragments differ significantly between the two methods.
Cable-suspended parallel manipulators have been a topic of research for multiple decades and called special attention in the fields of simulations. However, they are also well-suited for the simple evaluation of aerial-based mobile robot olfaction (MRO) algorithms, such as gas source localization and gas distribution mapping. Based on an open source framework for 3D printers, we designed a low-cost underconstrained, cable-suspended parallel manipulator. Computations are carried out purely on an Atmel ATmega2560 microcontroller.
An important aspect of micro or nano particles development is the understanding and control of the particle structure, as it can be determining for particle’s final function, and it affects among other things potential further surface functionalisation/modification.
This work shows the capability of resonant mass measurements (RMM) to measure the mass and density of micron sized particles. The technology utilizes a suspended MEMS microchannel resonator, through which individual particles transit across the resonator altering the resonant frequency, which is then detected using an optical-based method. Changes in frequency observed when a particle enters the microchannel resonator are proportional to the buoyant mass of the particle, and can be translated into mass, size or surface area. RMM therefore allows particle concentration to be determined as well as particle mass in a single measurement.
Furthermore, a method for estimating the density distribution of particles from RMM measurements has been developed. This uses the convolution of the buoyant mass distribution of the particles obtained when suspended in different fluids.
By combining the data from the density and mass determinations, small mass shifts arising from applying a coating to a particle can be estimated, and the resulting shell thicknesses calculated. These methods have been applied to silica coated and uncoated polystyrene latex particles.
RMM shows that it can be used to measure, and distinguish between, silica shell thicknesses that are in the order of 10s of nanometres on hybrid micron-sized particles
Microfluidic paper-based analytical devices (μPADs) in combination with surface enhanced Raman scattering (SERS) provide a way for analyses of complex mixtures. The μPADs can be used for the chromatographic separation of different compounds of mixtures in combination with the separate detection of the analytes in different zones on the paper by SERS. SERS allows to observe analytes directly without labelling in low concentrations in aqueous solutions and to identify them by their spectral fingerprint.
SERS substrates on the μPADs were created by drying standard silver nanoparticle (AgNP) solution on the paper. The microfluidic structure of the μPADs was prepared by wax printing. As a model system, an aqueous solution of the non-fluorescent analyte adenine and two fluorescent dyes tris(2,2’-bipyridyl)dichlororuthenium(II) and sulforhodamine B was tested. The dependency of the SERS signal intensity on the analyte concentration can be fitted using a Langmuir isotherm curve progression. With this approach, a semi-quantitative analysis of the components is possible. The reproducibility and stability of the measurement procedure was tested with several measurements over time, different NP batches, and with different analytes in different concentrations and resulted in an average relative standard deviation of 16 %.
The SERS spectra of the mixture of the model system are dominated by one compound depending on the concentration ratio. For the detection and identification of all components of the mixture, the compounds were therefore separated on the μPADs and measured at different positions. The position of adenine on the μPADs is dependent on the AgNP coverage of the paper. Due to this effect, it possible to detect adenine on a defined point on the μPADs and to get an information on the concentration in a mixture of three components.
The identification of external paint layers on medieval stained glass windows in Lincoln Cathedral is not only of interest for art historians but is also important for the development of conservation proposals. For the gradual reduction and removal of corrosion layers conservators have to take care to preserve any remaining paint layers which are hidden underneath these corrosion and weathering crusts.
X-ray computed tomography (CT) model holds only for THz-TDS reconstruction if minor refraction index differences between the inhomogeneities and the surrounding material matrix exist. A Time Domain SAFT algorithm has been developed to overcome the restrictions. THz time domain measurement on representative sample sets with inherent artefacts were performed to use them for the Image reconstructions. The results will be presented and compared with optical surface images of the used test objects to evaluate the SAFT algorithm in relation to the reconstruction quality.
Luminescence techniques are amongst the most commonly used analytical methods in the life and the material sciences due to their sensitivity and nondestructive character. All photoluminescence signals are, however, affected by wavelength-, polarization- and time-dependent instrument-related effects. Furthermore, substantial challenges to measure absolute luminescence intensities complicate the comparison of data recorded with different instruments and on the same instrument at different times. These problems can be easily resolved with fluorescence standards used for instrument performance validation (IPV) and determination of instrument-to-instrument variations, which allow to measure, quantify, and monitor the wavelength-dependent spectral responsivity for typically used instrument settings. For example, a set of liquid fluorescence standards, the BAM Kit F001-F005, and a ready-to-use glass-based fluorescence standard BAM F-012 developed and certified by BAM enable the characterization of many fluorescence parameters in the UV/vis wavelength range. For the increasingly used near infrared (NIR) region, standards and calibration tools are still very rare. Reliable spectral fluorescence standards and intensity or quantum yield standards are currently not available for the NIR, even though in biology, molecular imaging, and clinical diagnostics fluorescence labels absorbing and emitting in the long wavelength region beyond 650 nm are being increasingly used.
This limitation hampers the reliability and comparability of fluorescence measurements in the NIR and calls for simple fluorescence standards for instrument characterization and for the quantification of fluorescence intensities and efficiencies to improve the comparability of the emission measurements in the NIR. This encouraged us to assess the potential of several NIR-emitting materials as spectral fluorescence standards, thereby extending the BAM Kit from the UV/vis into the NIR up to 950 nm. Moreover, we currently certify quantum yield standards for the UV/vis/NIR to improve the reliability of relative measurements of this spectroscopic key quantity particularly > 650 nm. These tools enable an instrument characterization, signal referencing, quality assurance, traceability, and method validation now also for wavelengths > 650 nm, thereby improving the reliability of fluorescence data in pharmaceutical research, medical and clinical diagnostics, material analysis, and environmental monitoring.
Monitoring chemical reactions is the key to process control. Today, mainly optical online methods are applied, which are calibration intensive. NMR spectroscopy has a high potential for direct loop process control while cutting the calibration and validation needs to an minimum and thus exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environments for advanced process monitoring and control.
Intensified continuous processes are in focus of current research. Flexible (modular) chemical plants can produce different products using the same equipment with short down-times between campaigns and quick introduction of new products to the market. In continuous flow processes online sensor data and tight closed-loop control of the product quality are mandatory. Data analysis techniques are available but currently mostly used for off-line data analysis to detect the causes of variations in the product quality.
This is addressed within the EU’s Research Project CONSENS by the development and integration of a smart NMR module for process monitoring. The presented NMR module is provided in a mobile explosion proof housing and involves a compact spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction), and evaluation. Such “smart sensors” provide the basis for the future project “Industrie 4.0”, and Industrial Internet of Things (IIoT), along with current requirements to process control, model based control, or soft sensing. The module transforms the acquired online spectra of various technically relevant reactions to either conventional 4‒20 mA signals as well as WiFi based OPC-UA communication protocols, which enables NMR-based advanced process control and funny discussions with plant managers along with automation and safety engineers.
Assessment and validation of various flow cell designs for quantitative online NMR spectroscopy
(2017)
Compact nuclear magnetic resonance (NMR) instruments make NMR spectroscopy and relaxometry accessible in industrial and harsh environments for reaction and process control. Robust field integration of NMR systems have to face explosion protection or integration into process control systems with short set-up times. This paves the way for industrial automation in real process environments.
The design of failsafe, temperature and pressure resistant flow through cells along with their NMR-specific requirements is an essential cornerstone to enter industrial production plants and fulfill explosion safety requirements. NMR-specific requirements aim at full quantitative pre-magnetization and acquisition with maximum sensitivity while reducing sample transfer times and dwell-times. All parameters are individually dependent on the applied NMR instrument. Luckily, an increasing number of applications are reported together with an increasing variety of commercial equipment. However, these contributions have to be reviewed thoroughly.
The performance of sample flow cells commonly used in online analytics and especially for low-field NMR spectroscopy was experimentally and theoretically investigated by 1H-NMR experiments and numerical simulations. Here, we demonstrate and discuss an automated test method to determine the critical parameters of flow through cells for quantitative online NMR spectroscopy. The setup is based on randomized setpoints of flow rates in order to reduce temperature related effects. Five flow cells and tubings were assessed and compared for high-field as well as low-field NMR spectrometers.
For reaction monitoring and process control using NMR instruments, in particular, after acquisition of the FID the data needs to be corrected in real-time for common effects using fast interfaces and automated methods. When it comes to NMR data evaluation under industrial process conditions, the shape of signals can change drastically due to nonlinear effects. Additionally, the multiplet structure becomes more dominant because of the comparably low-field strengths which results in overlapping of multiple signals. However, the structural and quantitative information is still present but needs to be extracted by applying predictive models.
We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modeling). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants, or derivatives and robust automation schemes.
The exploration of metal phosphonates chemistry has gained great interest during the last decades, because of their structural diversity. Transition metal phosphonates are promising candidates for an application as electrocatalysts in oxygen reduction reactions (ORR). Here, we present the in situ investigation of mechanochemical syntheses of two different manganese phosphonates by synchrotron X-ray diffraction. Nitrilotri(methylenephosphonic acid) and N,N-Bis(phosphonomethyl)glycine were chosen as ligands. The liquid-assisted milling process can be divided into three steps, including an amorphous stage. One of the products has not been obtained by classical solution chemistry before.
These metal phosphonates and/or their derivatives are considered to be active in electrochemical energy conversion. The verification of their applicability is one of the topics of our resent research.
UCST-type thermoresponsive polymers that phase separate from solution upon cooling present a tremendous potential not only in aqueous media where they can be used in drug delivery, diagnostic and microfluidic applications, but also in water/alcohol mixtures, where they can be used for instance in sensing systems for alcohol-soluble drugs. However, only a few thermoresponsive polymers have been reported that present an UCST in a relevant temperature range and “green” solvents such as water or ethanol. In this context, acrylamide-based monomers can be very useful building blocks for designing novel UCST-type polymers because of their hydrophilic nature (with the right side chain) and propensity to form hydrogen bonds.
We want to present our latest results on the copolymer poly(acrylamide-co-acrylonitrile) (P(AAm-co-AN)) that present a UCST in water as well as on two homopolymers based on an acrylamide derivative of 2,6-diaminopyridine, namely poly(N-(6-aminopyridin-2-yl)acrylamide) (PNAPAAm) and poly(N-(6-acetamidopyridin-2-yl)acrylamide) (PNAcAPAAm) that show UCST-type thermoresponsiveness in water/alcohol mixtures.
Our focus for P(AAm-co-AN)) is its aggregation behaviour above and below its phase transition temperature as the size of thermoresponsive polymeric systems is of prime importance for biomedical applications (as size dependent processes take place in the body) and is linked to the optical properties of a material that matter in materials science.
In the case of PNAPAAm and PNAcAPAAm, we focused on the co-solvency/co-non solvency effect on the phase transition temperature in water/alcohol mixture. Indeed, polymers with UCST behavior below 60°C in water/alcohol mixtures are extremely promising for the preparation of “smart” materials for sensing.
Nanoparticles (NPs) have potential applications in medical diagnostics, imaging, drug delivery and other kinds of therapy. Furthermore, studies concerning nanoparticle uptake by cells are important for risk assessment. Size, shape and surface modification of the NPs determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes. Understanding the different uptake mechanisms and involved processes require sub-cellular resolution to determine, for example, whether the nanoparticles are reaching the nucleus. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. However, sub-cellular imaging has traditionally been challenging to achieve due to a lack of sensitivity at small laser spots. But now novel laser ablation systems with improved sensitivity and washout time allow imaging at high lateral resolution with spot sizes down to 1 µm.
Here LA-ICP-MS was applied for the imaging of individual fibroblast cells to study the uptake and intracellular processing of metal-containing NPs. To indicate cell morphology the local distribution of naturally occurring elements in cells like P and Zn was measured, too. Our results show that LA-ICP-MS can be used to localise nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time. The potential of LA-ICP-MS for analysis at single cell level will be demonstrated.
Mechanaochemistry is an effecthive method to yield pure compounds within a short reaction time. Mechanochemical C-C bond forming reactions gained increasing interest in the past decade. Among those the Knoevenagel condensation is an important reaction for synthezing a,b-unsaturated compounds. The information on the underlying mechanisms of mechanochemical reactions are scarce. In situ investigations using Raman spectroscopy and synchroton XRD either alone or in combination address this challenge. We present the in situ results of a Knoevenagel condensation with p-nitrobenzaldehyde and malononitrile under neat grinding conditions.
Electroplated magnetostrictive actuator layer enabling the external diagnosis of strain sensors
(2017)
Embedded fibre-opticaloptical strain sensors are suitable for structural health monitoring. In order to validate long-term performance (e.g.sensors integrated in airplane wings or wind power turbine blades) an external diagnostics is required.
A strain-detecting region of the optical fibre, the fibre Bragg grating (FBG, is encased by a magnetostrictive layer system serving as actuator. For the validation of the correct sensor function, an external magnetic field introduces mechanical strain resulting in a defined shift of the Bragg wavelength. The layer system is realized by acombined PVD /ECD process optimized regarding magnetostrictive and mechanical properties. The long -term stability of layer adhesion and actuator function has been verified.
1. Introduction
Alumina coatings are one possibility to increase the corrosion resistance, lifetime and application range of thermally loaded steel components, e.g. in modern power plants where the use of the Oxy-fuel technology corrosive fuel gas (H2O-CO2-O2-SO2 at 650 °C) affects the steel parts. In previous investigations the efficacy of protective alumina coatings on steel P 92 under those conditions was demonstrated. A shutdown and re-start of power plants or parts of them causes thermal stresses of the components which can cause detrimental effects like microstructural changes in the steel itself, changes in its oxidation behavior, delamination or microstructural changes in the coating. All those effects can lead to failure of the components, resulting in lifetime reduction.
2. Objectives
As a first step, we concentrate on the influence of thermal cycling tests and observe the impact on the microstructure of the coating and the interface in laboratory air. These investigations will help understanding the processes which occur, show directions of potentially necessary changes of the coating due to improved thermal stress behaviour.
3. Materials & methods
P 92 is a ferritic-martensitic steel, containing 9% Cr which forms protective Cr-oxide-rich scales in dry environments and non-protective ones in water-containing environments. Coupons of P 92, having ground surfaces, were dip-coated via a sol-gel process and subjected to thermal cycling for 500 h (1000 cycles) in laboratory air in a temperature range between room temperature and 660° C. The resulting mass loss was determined by weighing.
Samples for TEM investigations were produced as cross sections normal to the sample surface by FIB preparation (Quanta 3D, (FEI)). The TEM/STEM investigations were performed using a JEM2200FS (JEOL) operated at 200 kV. The microstructure of the coating and the interface after cycling tests was characterized via TEM, HREM, and STEM images, electron diffraction as well as EDX and EFTEM methods.
4. Results
At steep edges in the surface profile the coating was imperfect and cracks have formed during the thermal cycling. Flat surface regions are well-covered. The whole interface region between the steel and the coating shows a dense Cr-oxide-rich zone, which can form protective regions in case of local failure. The Cr-oxide zone is followed by a region of mixed oxides, containing Cr, Mn, Fe, and Al in variable composition, to which a porous δ-Al2O3 zone is joined.
5. Conclusions
• Alumina coatings promote the formation of dense, Cr-rich zones at the interface, which makes the system self-healing.
• These zones are stable during thermal stresses, even in regions with cracked coatings.
• They cause reduction of outward diffusion and mass loss during thermal cycling.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which are calibration intensive. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environments for advanced process monitoring and control.
Within the European Union’s Research Project CONSENS (Integrated CONtrol and SENsing by development and integration of a smart NMR module for process monitoring was designed and delivers online spectra of various reactions. The presented NMR module is provided in an explosion proof housing of 57 x 57 x 85 cm module size and involves a compact spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction), and evaluation.
For reaction monitoring and process control using NMR instruments after acquisition of the FID the data needs to be corrected in real-time for common effects using fast interfaces and automated methods.
When it comes to NMR data evaluation under industrial process conditions, the shape of signals can change drastically due to nonlinear effects. Additionally, the multiplet structure becomes more dominant because of the comparably low-field strengths which results in overlapping of multiple signals. However, the structural and quantitative information is still present but needs to be extracted by applying predictive models.
We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants, or derivatives and robust automation schemes.
The potential of electrospray deposition, for the controlled preparation of particles for imaging in electron microscopes, is evaluated on various materials: from mono-modal suspensions of spherical particles to multimodal suspensions and to real-world industrial materials. It is shown that agglomeration is reduced substantially on the sample carrier, compared with conventional sample preparation techniques. For the first time, it is possible to assess the number concentration of a tri-modal polystyrene suspension by electron microscopy, due to the high Deposition efficiency of the electrospray. We discovered that some suspension stabilizing surfactants form artifact particles during electrospraying. These can be avoided by optimizing the sprayed suspension.
Hydrothermal synthesis of anatase TiO2 nanosheets with a high fraction of exposed {001} facets and related high photocatalytic activity - as an alternative to bipyramidal anatase TiO2 nanoparticles mainly exposing the {101} facets. The scope of the material preparation work is the thermal reduction of residual fluorides from HF (capping agent) induced during the synthesis of TiO2 nanosheets by calcination at 873K. The analytical task consists of detection and localization of fluorine present at the surface and/or in the bulk of TiO2 nanosheets before and after calcination by SEM/EDX, Auger electron spectroscopy and ToF-SIMS.
Knowledge about feeding behavior is essential to determine trophic interactions and reconstruct predator-prey relationships in modern and past foodwebs. Traditionally, nitrogen isotopes (δ15N) of collagen are used to quantify the ingestion of animal protein, however collagen usually does not preserve over geological time scales. To infer the diet of extinct vertebrates from fossil material more resistant dietary proxies such as Ca and Mg isotopes are needed, which are major elements in the bioapatite of bones and teeth. Magnesium is a bio-essential element that replaces calcium in the bioapatite lattice and bone and enamel δ26Mg values of extant mammals increase systematically along the foodchain [1, 2].
The existing δ26Mg data, however, is scarce, in particular with respect to carnivores, thus still limiting the capability of this dietary proxy to reliably determine trophic differences between plant- and animal-feeders. To better constrain trophic-level effects recorded in Mg isotopes, we analyzed δ26Mg of bioapatite from modern mammals with a focus on faunivores, both carnivores and as yet unexplored insectivores.
The trophic level effect of δ26Mg is influenced by the geological substrate which causes isotope variability in δ26Mg of faunal remains between different ecosystems [1, 2]. Therefore, as first-order proxy for sample provenance and to assess potential influences of the bedrock substrate of the animals´ habitats on δ26Mg of bones and teeth, we measured the 87Sr/86Sr on the same specimens. This information will enable us to refine trophic level effects and determine whether δ26Mg can be used to distinguish different faunivores isotopically. This will be of paramount importance for dietary reconstructions of trophic niches in fossil foodwebs.
[1] Martin et al. (2014) Geochmica Cosmochimica Acta 130, 12-20. [2] Martin et al. (2015) Proceedings of the National Academy of Sciences 112, 430-435.
Mit der Verfügbarkeit der Mehr-Proben-Prüfung von bis zu 8 Klebverbunden mittels CAT-Technologie (CAT: centrifugal adhesion testing) wurde im Forschungsvorhaben OKTETT ein durchgehendes Mehr-Proben-Konzept zur Validierung der Klebfestigkeit angewendet. Dazu gehört ein universeller Probenteller (Abb.1) zur Mehr-Proben-Handhabung bei Vorbehandlung, Lagerung, Transport und Klebung. Für das Mehr-Proben-Kleben wurde die MSB-Technologie (MSB: multiple sample bonding) unter Verwendung einer instrumentierten hydraulischen Mehr-Proben-Kleb-vorrichtung entwickelt. Damit kann der Klebandruck für bis zu 8 Prüfkörper über einen Drucksensor definiert eingestellt und die gesamte Vorrichtung beim Kleben Temperaturen von bis zu 180°C ausgesetzt werden.
HPLC-MS/MS quantification of hepcidin-25, a new promising iron biomarker, in human serum samples
(2017)
Hepcidin-25 has attracted much attention ever since its discovery in 2001. It is widely recognized that this liver produced peptide hormone plays a major role in the regulation of iron levels in mammals. Hepcidin levels could reveal important clinical information about several pathological states in patients suffering from iron-related disorders such as chronic kidney disease (CKD) or hereditary haemochromatosis (HH). Despite significant efforts though, the development of a reliable assay to quantify hepcidin proved to be problematic for the last 15 years.
With the aim to tackle the current difficulties in hepcidin quantification and improve the status of this promising biomarker in the clinical field, we developed a rapid and robust analytical strategy for the quantification of hepcidin-25 in human samples based on HPLC-MS/MS (QqQ) to be implemented in routine laboratories. The novelty of the method is the use of special HPLC vials to avoid adsorptive losses due to the basic character of the peptide that causes interaction with the silanol groups of the vial’s glass surface. Up to 90% decrease in the MS/MS signal was observed, when commercial HPLC vials were used, while vials treated with 3-(2-aminoethylamino)propylmethyl-dimethoxysilane or 1H,1H,2H,2H-perfluorooctyltriethoxysilane, leading to no significant losses in the dynamic range of physiological hepcidin-25 mean serum levels (10-20 µg/L).
Careful analytical validation was performed for determining the reproducibility, repeatability, limit of quantification (0.5 µg/L) and linearity (0.5-40 µg/L) of the method. Serum samples from 9 healthy volunteers were analyzed with a median hepcidin-25 level of 3.3 µg/L, comparable to results reported in the literature.
"The optical properties of semiconductor nanocrystals (SCNC) are controlled by constituent material, particle size, and surface chemistry, specifically the number of dangling bonds favoring nonradiative deactivation. This can lead to a distribution of photoluminescence Quantum yields (PL QY) amongst the SCNC particles, i.e., mixtures of “bright” and “grey” or “dark” SCNCs.
Particularly the number of absorbing, yet not emitting particles can have a significant effect on the PL quantum yield obtained in ensemble measurements, leading to ist underestimation. The “dark fraction” is not assessable in common ensemble measurements; it can be probed only on a single particle level using a confocal laser scanning microscope coupled with an AFM. Such a setup was used to study core‐shell CdSe SCNCs with different shells and surface chemistries. Special emphasis was dedicated to correlate brightness, blinking, dark fraction, and decay kinetics of the single SCNCs with the ensemble PL QY and the PL decay kinetics. The results of this study can help to identify new synthetic routes and surface modifications to colloidally and photochemically stable SCNCs with a PL QY of close to unity."
A method for the examination of the epitope of a monoclonal antibody against a peptide related to hepcidin-25, known as a biomarker in the ion metabolism, was developed. Characterizing the exact binding site helps to understand the properties of the antibody. A peptide consists of different amino acids, each contributing differently to the binding strength. To examine the influence of the amino acids, each amino acid was subsequently exchanged by glycine. If the respective amino acid is critical for binding to the antibody, a significant drop in the binding affinity should be observed.
The epitope screening of monoclonal antibodies is a complex and elaborate procedure. For this approach, variants of the peptides were synthesized by conventional Fmoc-based peptide synthesis. The solid support was chosen to be suitable for the synthesis and additional screening against the antibody. To determine the binding affinity, the bead-bound peptides were incubated with a fluorophore-labeled antibody. After the incubation, the beads were placed on a slide and the fluorescence was detected by a fluorescence scanner. A high fluorescence indicates a high binding affinity and vice versa.
Raman spectroscopy is becoming a powerful process analytical technology (PAT) tool. Until now Raman technology has not shown its full potential in bioprocess on-line monitoring due to several technical challenges. Because of only small? interference from water molecules, Raman-spectroscopy is in contrast to IR spectroscopy able to follow changes of metabolite concentrations in dilute aqueous solutions. Results from common CCD-based process Raman-spectrometers reveal only barely identifiable peaks with a dominating (fluorescence) background. To solve this, Raman spectroscopy needs: (A) an enhancement to increase the limit of detection (LOD), and (B) a reliable method to distinguish the Raman signal from the sample-related auto-fluorescence.
SERS (surface enhanced Raman spectroscopy) acts as an optical "nano-antenna"-effect. It causes a dipolar localized surface Plasmon resonance effect due to noble metallic nanoparticles or roughened metal and improves the limit of detection (LOD) significantly. Another new process-monitoring technique, which removes the fluorescence background in Raman-measurements is called time-gated Raman spectroscopy. It uses a picosecond pulsed Nd:YVO4-laser as emission source (exc= 532 nm) and a gated SPAD-array (Single Photon Avalanche Detector) detector instead of commonly used CCD (Charged Coupled Device)-detectors and CW (Continues Wave) laser emission. Time-Gate can measure the Raman-signal before the stronger fluorescence signal reaches the detector.
In this study we utilized both SERS (Surface Enhanced Raman Spectroscopy) and time-gated Raman spectroscopy (TG-Raman) in combination on cell-free supernatant samples of an Escherichia coli cultivation with mineral salt media and a lactic acid bacteria fermentation with complex media. As a reference method for the estimation of amino acids and other metabolites, HPLC-RID and HPLC-FLD were used to evaluate the Raman-based detection. The quantitative evaluation of Raman data was performed by multivariate data analysis such as principal component analysis (PCA) and partial least squares regression (PLSR). For the first time, we can show that both qualitative and quantitative measurements are conducted successfully with both, SERS and time-gated Raman methods in industrially relevant media, so that a fast and reliable in situ or bypassed concentration measurement becomes feasible.