Analytische Chemie
Filtern
Erscheinungsjahr
- 2022 (89) (entfernen)
Dokumenttyp
- Posterpräsentation (89) (entfernen)
Referierte Publikation
- nein (89)
Schlagworte
- Fluorescence (6)
- BAMline (5)
- Process Analytical Technology (4)
- X-ray imaging (4)
- Additive manufacturing (3)
- Amperometry (3)
- Benchtop NMR (3)
- Bioinformatics (3)
- Luminescence (3)
- Metrology (3)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (38)
- 8 Zerstörungsfreie Prüfung (27)
- 6 Materialchemie (18)
- 1.8 Umweltanalytik (10)
- 8.5 Röntgenbildgebung (10)
- 6.1 Oberflächen- und Dünnschichtanalyse (9)
- 1.1 Anorganische Spurenanalytik (6)
- 1.2 Biophotonik (6)
- 4 Material und Umwelt (6)
- 6.3 Strukturanalytik (6)
- 1.4 Prozessanalytik (5)
- 1.9 Chemische und optische Sensorik (5)
- 8.0 Abteilungsleitung und andere (5)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (5)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (5)
- VP Vizepräsident (5)
- VP.1 eScience (5)
- 6.6 Physik und chemische Analytik der Polymere (4)
- 8.4 Akustische und elektromagnetische Verfahren (4)
- 1.6 Anorganische Referenzmaterialien (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 4.2 Material-Mikrobiom Wechselwirkungen (3)
- 1.5 Proteinanalytik (2)
- 1.3 Instrumentelle Analytik (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.5 Sicherheit von Gasspeichern (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 4.3 Schadstofftransfer und Umwelttechnologien (1)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 8.6 Faseroptische Sensorik (1)
Steps Forward in the Application of 3,3’,5,5’- Tetramethylbenzidine (TMB) in Amperometric Assays
(2022)
Electrochemical methods make great promise to meet the demand for user-friendly on-site devices for monitoring important parameters. Food industry often runs own lab procedures, e.g. for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with miniaturized technologies. Enzyme-linked immunosorbent assays, with photometric detection of the horseradish peroxidase (HRP) substrate, 3,3’,5,5’-tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straight-forward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material.
It was found that screen-printed gold electrodes and a highly acidic pH value (pH 1) are well-suited to perform the electrochemical detection of TMB, due to the reversible character of the redox reaction under these conditions. This set-up provides a good signal stability over several measuring cycles, providing the basis for analysing multiple samples. In contrast to this, for carbon screen-printed electrodes, it was found that the signal response has changed after the electrochemical reaction with TMB at pH 1. At a weakly acidic pH value (pH 4), neither with carbon nor with gold electrodes a reproducible electrochemical detection of TMB could be achieved [1].
Based on these findings we created a smartphone-based, electrochemical, immunomagnetic assay for the detection of ochratoxin A and ergometrine in real samples. Therefore, a competitive assay was performed on magnetic beads using HRP and TMB/H2O2 to generate the signal. Enzymatically oxidized TMB was quantified after addition of H2SO4 by amperometry with screen-printed gold electrodes in a custom-made wall-jet flow cell. The results are in good correlation with the established photometric detection method, providing a solid basis for sensing of further analytes in HRP-based assays using the newly developed miniaturized smartphone-based, electrochemical, immunomagnetic assay.
Soil acts as a final sink for pollutants. Microplastics from different sources such as plastic mulching, littering, compost, sewage sludge, sedimentary deposition, and tyre abrasion are expected to be found in soil. However, representative and comprehensive information is missing on the sources, transport, and fate. Therefore, a reliable analysis method for microplastics in soils needs to be developed.
The presented work describes the development of a procedure for microplastics analysis in soils. A representative sampling based on the on-site conditions and a sample preparation method was established and comprised of a drying step, the separation of microplastic particles > 1 mm, and a density separation for particles < 1 mm. The detection of the large microplastic particles (> 1 mm) was conducted with Attenuated Total Reflection - Fourier Transform infrared Spectroscopy (ATR-FTIR) , while Thermal Extraction Desorption - Gas Chromatography / Mass Spectrometry (TED-GC/MS) was applied for particles < 1 mm, gaining information on the type of polymer and mass fraction. Based on the established method, 14 environmental soil samples ? with different exposure of microplastics from agriculture, industrial sites, roads, and floods were investigated.
Due to the arbitrary microplastic particle distribution among the samples for large microplastics, it was reasoned that the found particles were unrepresentative. In contrast, microplastic particles < 1 mm were discovered in a high mass in soil samples exposed to plastic mulching or fertilization with sewage sludge or compost (0 – 115 mg/kg). On average, microplastic contents detected in soil samples taken from a construction site and an inner-city lake were higher (13 – 238 mg/kg). As expected, microplastic content in soil sampled in proximity to roads was more pronounced in the upper soil layers. In contrast, very remote sampling sites, expectably uncontaminated, did not lead to the detection of microplastic regarding to thermoanalytical detection method.
In a proof of concept experiment several in vivo and in vitro ecotoxicological tests were applied to evaluate the effect of microplastics (tyre abrasion, polystyrene containing hexabromocyclododecane) in natural soils. In summary, while no effects of the examined probes could be detected on higher levels of biological organization after exposures to earthworm E. andrei, significant changes in several oxidative stress related biomarkers were observed.
MXenes are a new family of two-dimensional (2D) transition metal carbides, carbonitrides, and nitrides discovered in 2011. Among many reported family members, titanium carbide is the most widely studied and explored due to the optimized synthesis conditions and promising characteristics like good mechanical strength, solution processability, and excellent conductivity. Here, we report the development of an electrochemical biosensor involving the amine-functionalized Few-Layered-Titanium Carbide Nanosheets and monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SARS-CoV-2 mAb) to design a point-of-care device for detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 NP) antigen.
The European Metrology Network (EMN) for Advanced Manufacturing has been established in June 2021. Currently nine EMNs focussing on different important topics of strategic importance for Europe exist and form an integral part of EURAMET, the European Association of National Metrology Institutes (NMI). EMNs are tasked to ▪ develop a high-level coordination of the metrology community in Europe in a close dialogue with the respective stakeholders (SH)
▪ develop a strategic research agenda (SRA) within their thematic areas
▪ provide contributions to the European Partnership on Metrology research programme Based on the analysis of existing metrology infrastructures and capabilities of NMIs, the metrology research needs for advanced manufacturing are identified in close cooperation with academic, governmental and industrial stakeholders.
Here, we report on the progress of the EMN for Advanced Manufacturing.
The BAMline at the synchrotron X-ray source BESSY II (Berlin, Germany) is supporting researchers in a wide range of research areas since more than 20 years. These fields include biology, cultural heritage, medicine, and also materials science. As a non-destructive characterization method, synchrotron X-ray imaging, especially tomography with hard X-Rays, plays an important role in structural 3D characterization. A recent upgrade of key equipment at the BAMline expands the imaging capabilities towards shorter acquisition times. Therefore, in-situ and operando experiments can now be routinely conducted. Also, different energy resolutions can be set up to optimize flux and energy resolution as desired. This requires an adaptation of the used reconstruction methods in order to perform necessary analyses also during the experiment. In this presentation the equipment, data handling pipeline as well as various examples from material science are presented.
The BAMline at the 3rd generation synchrotron X-ray source BESSY II has been supporting researchers in a wide range of research areas for over 20 years. In addition to materials science, these fields also include biology, cultural heritage, and medicine. Being a non-destructive characterization method, synchrotron X-ray imaging, in particular tomography (SXCT), plays a particularly important role in structural characterization. A recent upgrade of key BAMline equipment expands the imaging capabilities: The upgraded dual multilayer monochromator offers flexibility by providing different energy spectra to optimize flux and energy resolution as desired. Different spectra (8 – 60 keV with ΔE/E 0.01%, 1.5%, 4% and pink beam) can be selected. The upgraded detector (in white beam configuration, equipped with an sCMOS camera) allows the higher flux to be exploited with reduced readout times. Shorter tomographic acquisition times in the range of seconds are now possible. Hence, in-situ and operando examinations are routinely available. An integrated slip ring allows continuous rotation of the sample stage for ease of wiring. The pink beam option allows tomographic observation of processes occurring in the time domain of a few seconds with a resolution down to ~ 1 µm. Different scan methods, optimized for quality and speed are available and discussed. Examples of energy related materials from fuel cell and battery research are shown.
An optional end station allows refraction enhanced imaging (synchrotron X-Ray refraction radiography (SXRR) and tomography (SXRCT)). That includes an analyzer Si-crystal in Bragg alignment between sample and detector. This technique obtains sensitivity to smaller structures (cracks, pores) down to a few wavelengths, while obtaining field of view sizes in the range of several mm. Besides medicine (e.g., teeth explants), several applications are found in material science, like studies on diesel particulate filters, ceramics, additively manufactured (AM) alloys and metal matrix composites (MMC). The in-situ capabilities include mechanical load (tension and compression) and heating up to 1100°C. A case study, the microstructural evolution during heat treatment of an AM AlSi10Mg, will be shown.
Thirteen laboratories participated in an international interlaboratory comparison for the determination of 87Sr/86Sr isotope ratios in four cement reference materials (RM) using the conventional method for 87Sr/86Sr isotope ratios analyses. Sample dissolution and Sr isolation via ion exchange chromatography were required since the cement samples were distributed as powders. Analytical preparation included the use of various digestion methods including mixed mineral acids, microwave/acid, bomb/acid digestion or borate fusion, followed by Sr separation using ion exchange chromatography. In this study, we evaluated whether any statistically significant differences were attributable to instrumental differences (i.e., MC-ICP-MS and MC-TIMS), or to laboratory-specific techniques (different sample preparation techniques, Sr isolation and the procedures for correcting the data outputs). To evaluate these effects, consensus values for cement RMs and associated standard uncertainties were estimated by fitting a linear, Gaussian mixed effects model using the R function “lmer” defined in package “lme4”. No statistically significant effects (SSE) attributable to instrumental differences regardless of whether the materials are considered together or separately were evident. There were SSE attributable to differences between laboratories for three cement RMs when the individual cements were considered separately. Since consideration or disregard for such differences does not induce significant changes in the estimate of the consensus values for the 87Sr/86Sr isotope ratios in cement RMs, these effects can safely be neglected when calculating the best estimates for the true values of 87Sr/86Sr isotope ratios in these RMs.
Responsible treatment of the environment and resources is a key element of sustainability. The building and construction industry is one of the largest consumers of natural resources. Consequently, there is a particular need for regulations and technologies that help to create closed material cycles. From the technological point of view, such efforts are complicated by the growing material diversity and the amount of composites contained in present and future construction and demolition waste (CDW). Nowadays, simple but proven techniques like manual sorting are mainly used. However, this practice not only poses health risks and dangers to the staff performing the work, but also relies on merely obvious, visually striking differences. Automated, sensor-based sorting of these building materials could complement or replace this practice to improve processing speed, recycling rates, sorting quality, and prevailing health conditions. The preliminary results for the identification of a wide variety of building materials with LIBS are presented.
pH presents one of the most important analytes in the life and material sciences, indicating, e.g., diseases and corrosion processes. This includes the optical monitoring of pH in living cells for studying cellular internalization pathways, such as phagocytosis, endocytosis, and receptor mediated internalization with the aid of molecular and nanoscale fluorescent sensors. Nanoparticle (NP)-based sensors, that are labelled or stained with a multitude of sensor dyes, have several advantages as compared to conventional molecular probes like enhanced brightness, i.e., amplified signals, ease of designing ratiometric systems by combining analyte-sensitive and inert reference dyes, and increased photostability. Moreover, this can enable the use of hydrophobic dyes in aqueous environments. Versatile templates and carriers for the fabrication of nanosensors by staining and/or labelling with different fluorophores and sensor molecules are surface-functionalized particles like silica (SiO2) and polystyrene (PS) particles. Here we present a platform of blue-red-green fluorescent pH nanosensors for the measurement of acidic, neutral, and basic pH utilizing both types of matrices and two spectrally distinguishable sensor dyes with an integrated reference dye and demonstrate its applicability for cellular studies.