Analytische Chemie
Filtern
Erscheinungsjahr
- 2022 (615) (entfernen)
Dokumenttyp
- Vortrag (217)
- Zeitschriftenartikel (191)
- Posterpräsentation (89)
- Beitrag zu einem Tagungsband (59)
- Forschungsbericht (17)
- Sonstiges (15)
- Forschungsdatensatz (10)
- Buchkapitel (7)
- Dissertation (2)
- Handbuch (2)
Sprache
- Englisch (529)
- Deutsch (85)
- Mehrsprachig (1)
Schlagworte
- Fluorescence (24)
- Digitalization (22)
- Certification (20)
- Conformity assessment (20)
- COVID-19 (19)
- Digital transformation (19)
- Sensor (19)
- Calibration (18)
- Conformity assessment body (18)
- Quality infrastructure (18)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (235)
- 1 Analytische Chemie; Referenzmaterialien (215)
- 6 Materialchemie (111)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (54)
- 8.4 Akustische und elektromagnetische Verfahren (53)
- 8.0 Abteilungsleitung und andere (52)
- 1.1 Anorganische Spurenanalytik (44)
- 8.5 Röntgenbildgebung (44)
- 6.1 Oberflächen- und Dünnschichtanalyse (42)
- 1.2 Biophotonik (40)
- 6.3 Strukturanalytik (40)
- 1.8 Umweltanalytik (35)
- S Qualitätsinfrastruktur (32)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (31)
- S.2 Digitalisierung der Qualitätsinfrastruktur (30)
- 1.3 Instrumentelle Analytik (28)
- 4 Material und Umwelt (27)
- 1.4 Prozessanalytik (26)
- 1.9 Chemische und optische Sensorik (21)
- 8.6 Faseroptische Sensorik (20)
- 1.7 Organische Spuren- und Lebensmittelanalytik (19)
- 6.6 Physik und chemische Analytik der Polymere (19)
- 1.5 Proteinanalytik (18)
- 1.6 Anorganische Referenzmaterialien (16)
- VP Vizepräsident (16)
- VP.1 eScience (16)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (15)
- 6.0 Abteilungsleitung und andere (14)
- 4.3 Schadstofftransfer und Umwelttechnologien (10)
- 4.2 Material-Mikrobiom Wechselwirkungen (9)
- 7 Bauwerkssicherheit (9)
- 9 Komponentensicherheit (9)
- 3 Gefahrgutumschließungen; Energiespeicher (7)
- 4.5 Kunst- und Kulturgutanalyse (6)
- 5 Werkstofftechnik (5)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (4)
- 9.0 Abteilungsleitung und andere (4)
- 5.1 Mikrostruktur Design und Degradation (3)
- 6.2 Material- und Oberflächentechnologien (3)
- 7.4 Baustofftechnologie (3)
- 7.6 Korrosion und Korrosionsschutz (3)
- 9.5 Tribologie und Verschleißschutz (3)
- 1.0 Abteilungsleitung und andere (2)
- 2 Prozess- und Anlagensicherheit (2)
- 3.5 Sicherheit von Gasspeichern (2)
- 4.1 Biologische Materialschädigung und Referenzorganismen (2)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (2)
- 5.4 Multimateriale Fertigungsprozesse (2)
- 9.4 Integrität von Schweißverbindungen (2)
- P Präsident (2)
- P.0 Präsident und andere (2)
- S.1 Qualität im Prüfwesen (2)
- 2.1 Sicherheit von Energieträgern (1)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (1)
- 3.2 Gefahrguttanks und Unfallmechanik (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 6.7 Materialsynthese und Design (1)
- 7.1 Baustoffe (1)
- 7.3 Brandingenieurwesen (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
- 7.7 Modellierung und Simulation (1)
- 9.2 Versuchsanlagen und Prüftechnik (1)
- 9.6 Additive Fertigung metallischer Komponenten (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (5)
While there is a extensive literature on the micro-mechanical behavior of metal matrix composites (MMCs) under uniaxial applied stress, very little is available on multi-phase MMCs. In order to cast light on the reinforcement and damage processes in such multi-phase composites, an Al alloy with one and two ceramic reinforcements (planar-random oriented alumina fibers and SiC particles) were studied. In-situ compression tests during neutron diffraction experiments were used to track the load transfer among phases, while X-ray computed tomography was used to investigate pre-strained samples, in order to monitor and quantify damage. We found that damage progresses differently in composites with different orientations of the fiber mat. Because of the presence of the intermetallic network, it was observed that the second ceramic reinforcement changes the load transfer scenario only at very high applied load, when also intermetallic particles break. We rationalized the experimental results by means of a micromechanical model based on Maxwell’s homogenization scheme, and we could explain why no damage is observed in the ductile matrix under compression: the matrix finds itself in hydrostatic compression, and the Poisson’s tensile strain is totally carried by the reinforcement phases
Global Status and Trends in Digital Transformation and Conformity Assessment – The Case of Germany
(2022)
This presentation summarizes findings from the first comprehensive study on digitalization in conformity assessment worldwide. The reults are based on data from a survey among conformity assessment bodies (CABs) in Germany conducted in 2022, as well as some first insights from Latin American countries. It highlights the digital maturity of the organizations, the motives, benefits and obstacles of digital transformation as well as the actual technology trends.
The study on CABs is part of a global project that covers various countries (see www.qi-fokus.de).
Die Optimierung und Validierung des digitalen Wasserstofftankstellenmanagements mit Sensortechnologien ist das übergeordnete Ziel des Teilprojekts Digitale Qualitätsinfrastruktur mit Sensortechnologien (QIST) am Use Case H2, im Rahmen der digitalen Qualitätsinfrastruktur (QI digital[1]). Hierfür sollen u.a. Sensornetzwerke mit digital-gestützten Auswertungsstrategien intelligent gestaltet werden (Stichwort KI bzw. digitaler Zwilling). Verschiedene, sich ergänzende Sensoren, Systemkomponenten und KI-Methoden stehen als Bausteine intelligenter Sensorsysteme zur Verfügung, mit dem Zweck, die physikalischen und chemischen Parameter an und in Anlagen umfassend und effizient zu überwachen sowie Fehlfunktionen zuverlässig zu detektieren und zu interpretieren, Abbildung 1.
Konkrete Arbeitsschritte sind, nach dem Aufbau der Versuchsplattform „Wasserstofftankstelle“, die Instrumentierung von Sensorik und deren digitale Integration in das Tankstellenmanagementsystem sowie die Validierung im Realbetrieb. Die somit erzielten Messergebisse sowie die Messunsicherheiten, Historien und Verfahren werden in digitaler Form aufbereitet, gespeichert und fortlaufend in die KI-basierte Datenauswertung einbezogen, inkl. der Anbindung an die metrologische Rückführungskette.
Ziele sind:
• Einführung eines neuen messtechnischen Ansatzes und eines digitalen Zwillings für den Anwendungsfall "Wasserstofftankstelle" auf Basis der H2-Sensorik sowie der Zustandsgrößen Druck und Temperatur
• Qualitätssicherung durch Applikationen zuverlässiger Gassensorik, Manometer und Thermometer sowie KI-Methoden zur Prozesskontrolle und Detektion von Fehlfunktionen
• Nutzung von digitalen Kalibrierscheinen (DCCs) insbesondere für die Messgröße Temperatur zur Realisierung der metrologischen Rückführung in einer digitalen Qualitätsinfrastruktur
Ultrasonic probes for high-temperature applications are provided with metallic wedges, which can withstand the contact with the high temperature of the inspected structure. The ultrasonic signal travels within the wedge and gets reflected from its boundaries, causing interference signals called “ghost echoes”. The current work presents an investigation of the additional damping effect provided by porous sintered metal plates applied onto the surface of the wedge. In particular, the study evaluates the effect of damping plate thickness on the interference signal level at different transmission frequencies. Damping plates made of sintered metal SIKA-R 15 AX were attached to a wedge prototype made of steel 1.4301. The study revealed, that the most effective thickness of damping plates in the selected frequency interval of 1 to 4 MHz is equal to 4 mm. The evaluation of the interference signal has shown that the application of such damping plates to the wedge surface contributes to an additional attenuation of an interference signal of 10 to 30 dB after 500 μs of signal propagation.
In this work, we report on a method for automatic inspection of components using laser scanning thermography, in which the relative motion is performed by a robot to fully inspect complex test objects such as turbine blades. We demonstrate our evaluation algorithms with the aim of automatically detecting surface defects on calibrated specimens. We show the influence of the excitation laser, which can be varied in terms of spot geometry, wavelength, and scan scheme. Additionally, we show some advantages, versatility, and current challenges of using a programmed robot for non-destructive evaluation in thermography.
Analysis of electrochemical and liver microsomal transformation products of lasalocid by LC/HRMS
(2022)
Rationale: Lasalocid (LAS), an ionophore, is used in cattle and poultry farming as feed additive for its antibiotic and growth-promoting properties. Literature on transformation products (TP) resulting from LAS degradation is limited. So far, only hydroxylation is found to occur as the metabolic reaction during the LAS degradation. To investigate potential TPs of LAS, we used electrochemistry (EC) and liver microsome (LM) assays to synthesize TPs, which were identified using liquid chromatography high-resolution mass spectrometry (LC/HRMS).
Methods: Electrochemically produced TPs were analyzed online by direct coupling of the electrochemical cell to the electrospray ionization (ESI) source of a Sciex Triple-TOF high resolution mass spectrometer. Then, EC-treated LAS solution was collected and analyzed offline using LC/HRMS to confirm stable TPs and improve their annotation with a chemical structure due to informative MS/MS spectra. In a complementary approach, TPs formed by rat and human microsomal incubation were investigated using LC/HRMS. The resulting data were used to investigate LAS modification reactions and elucidate the chemical structure of obtained TPs.
Results: The online measurements identified a broad variety of TPs, resulting from modification reactions like (de-)hydrogenation, hydration, methylation, oxidation as well as adduct formation with methanol. We consistently observed different ion complexations of LAS and LAS-TPs (Na+; 2Na+ K+; NaNH4 +; KNH4 +). Two stable methylated EC-TPs were found, structurally annotated, and assigned to a likely modification reaction. Using LM incubation, seven TPs were formed, mostly by oxidation/hydroxylation. After the identification of LM-TPs as Na+-complexes, we identified LM-TPs as K+-complexes.
Conclusion: We identified and characterized TPs of LAS using EC- and LM-based methods. Moreover, we found different ion complexes of LAS-based TPs. This knowledge, especially the different ion complexes, may help elucidate the metabolic and environmental degradation pathways of LAS.
Diffraction enhanced imaging (DEI) is an advanced digital radiographic imaging technique employing the refraction of X-rays to contrast internal interfaces. This study aims at qualitatively and quantitatively evaluating images acquired using this technique and to assess how different fitting functions to the typical rocking curves (RCs) influence the quality of images. RCs are obtained for every image pixel. This allows the separate determination of the absorption and the refraction properties of the material in a position-sensitive manner. Comparison of various types of fitting functions reveals that the Pseudo-Voigt (PsdV) function is best suited to fit typical RCs. A robust algorithm was developed in the Python programming language, which reliably extracts the physically meaningful information from each pixel of the image. We demonstrate the potential of the algorithm with two specimens: a silicone gel specimen that has well-defined interfaces, and an additively manufactured polycarbonate specimen.
CS particles show unique properties by merging individual characteristics of the core and the shell materials. An alteration particularly in their surface roughness affects the final performance of the particles in the targeted application. Quantitative evaluation of the roughness of CS microparticles is, however, a challenging task employing microscopic techniques being scarce and showing large differences in terms of methodology and results.
In our previous work, we have reported a systematic study with a reliable analysis tool, which evaluates profile roughness quantitatively, for individual core-shell microparticles using electron microscopy (EM) images of both types, Scanning Electron Microscopy (SEM) and transmission mode SEM (or TSEM). The SEM images contain two-dimensional (2D) information, therefore, provide profile roughness data only from the projection in the horizontal plane (in other words, from the “belly”) of a spherical particle. The present study offers a practical procedure to give access to more information by tilting the sample holder and hence allowing images of a single particle to be recorded at different orientations under the same view angle. From the analysis of these images, extended information on surface roughness of the particle can be extracted. Thus, instead of obtaining 2D information from a single SEM image, three-dimensional (3D) information is obtained from 2D projections recorded at different particle orientations.
This report summarizes findings from the first comprehensive study on digitalization in conformity assessment in Italy. The reults are based on data from a survey among conformity assessment bodies (CABs) conducted in 2022. It highlights the digital maturity of the organizations, the motives, benefits and obstacles of digital transformation as well as the actual technology trends.
The study on Italian CABs is part of a global project that covers various other countries (see www.qi-fokus.de).
Photothermal characterization of polyester composites loaded with parallelly arranged graphite rods
(2022)
One of the biggest challenges in the measurement of thermal properties is to measure inhomogeneous materials This work focuses on measuring the thermal properties of cylindrical polyester resin composite materials loaded with graphite rods oriented in the direction of the resin thickness, varying the graphite concentrations starting from zero to 8 75 of volumetric fraction and changing the distribution of graphite rods inside the polyester matrix
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays (MBBAs) allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
A first tricolor fluorescent pH nanosensor is presented, which was rationally designed from biocompatible carboxylated polystyrene nanoparticles and two analyte-responsive molecular fluorophores. Its fabrication involved particle staining with a blue-red-emissive dyad, consisting of a rhodamine moiety responsive to acidic pH values and a pH-inert quinoline fluorophore, followed by the covalent attachment of a fluorescein dye to the particle surface that signals neutral and basic pH values with a green fluorescence. These sensor particles change their fluorescence from blue to red and green, depending on the pH and excitation wavelength, and enable ratiometric pH measurements in the pH range of 3.0−9.0. The localization of the different sensor dyes in the particle core and at the particle surface was confirmed with fluorescence microscopy utilizing analogously prepared polystyrene microparticles. To show the application potential of these polystyrene-based multicolor sensor particles, fluorescence microscopy studies with a human A549 cell line were performed, which revealed the cellular uptake of the pH nanosensor and the differently colored emissions in different cell organelles, that is, compartments of the endosomal-lysosomal pathway. Our results demonstrate the underexplored potential of biocompatible polystyrene particles for multicolor and multianalyte sensing and bioimaging utilizing hydrophobic and/or hydrophilic stimuli-responsive luminophores.
A fluorolytic sol–gel method was used for the fast and simple synthesis of small cubic-phase SrF2:Yb3+, Er3+ upconversion (UC) nanocrystals (UCNC) of different composition at room temperature. Systematic studies of the crystal phase and particle size of this Yb3+,Er3+-concentration series as well as excitation power density (P)-dependent UC luminescence (UCL) spectra, UCL quantum yields (ΦUCL), and UCL decay kinetics yielded maximum UCL performance for doping amounts of Yb3+ of 13.5% and Er3+ of 1.3% in the studied doping and P-range (30–400 W cm−2). Furthermore, ΦUCL were determined to be similar to popular β-NaYF4:Yb3+,Er3+. The relative spectral UCL distributions revealed that all UCNC show a strong red emission in the studied doping and P-range (30–400 W cm−2) and suggest that the UCL quenching pathway for unshelled cubic-phase SrF2:Yb3+,Er3+ UCNC differs from the commonly accepted population and depopulation pathways of β-NaYF4:Yb3+,Er3+ UCNC. In SrF2:Yb3+,Er3+ UCNC the 4S3/2 →
4I13/2 transition exhibits a notably stronger sensitivity towards P and reveals increasing values for decreasing Yb3+–Yb3+ distances while the 4I9/2 → 4I15/2 transition is significantly less affected by P and energy migration facilitated UCL quenching. These results emphasize the complexity of the UC processes and the decisive role of the crystal phase and symmetry of the host lattice on the operative UCL quenching mechanism in addition to surface effects. Moreover, the room temperature UCNC synthesis enabled a systematic investigation of the influence of the calcination temperature on the crystal phase of powder-UCNC and the associated UCL properties. Calcination studies of solid UCNC of optimized doping concentration in the temperature range of 175 °C and 800 °C showed the beneficial influence of temperature-
induced healing of crystal defects on UCL and the onset of a phase separation connected with the oxygenation of the lanthanide ions at elevated temperature. This further emphasizes the sensitivity of the UC process to the crystal phase and quality of the host matrix.
Li-rich nanoparticles of Li1+xMn2–xO4 doped with Al, Co, or Ni are successfully synthesized using a facile, fast, and efficient microwave-assisted hydrothermal route. Synchrotron X-ray diffraction confirms the formation of the crystalline cubic spinel phase type. X-ray absorption spectroscopy analysis at the Co and Ni K- and L-edges verifies that the dopants are within the Li1+xMn2–xO4 spinel structure and are inactive during cycling in the bulk and at the surface. Moreover, we demonstrate that nanocrystallinity and cationic doping play an important role in improving the electrochemical performance with respect to LiMn2O4 microparticles. They significantly reduce the charge-transfer resistance, lower the first cycle irreversible capacity loss to 6%, and achieve a capacity retention between 85 and 90% after 380 cycles, with excellent Coulombic efficiency close to 99% without compromising the specific charge at a 5C cycling rate. Furthermore, the Mn K- and L-edges attest that after long cycling, the Mn oxidation state in the bulk differs from that at the surface caused by the Mn disproportion reaction; however, the cationic doping helps mitigate the Mn dissolution with respect to the undoped Li1+xMn2–xO4 nanoparticles, as indicated by inductively coupled plasma atomic emission spectrometry.
Fluid inclusion microthermometry is one of the analytical approaches that has been proposed for speleothem-based temperature reconstructions. The proxy of this paleothermometer is the density of drip water relicts that have been enclosed in microscopic fluid inclusions during speleothem growth. Prior to microthermometric analyses, the monophase liquid inclusions need to be transferred from a metastable liquid into a stable liquid-vapour two-phase state by stimulating vapour bubble nucleation by means of single ultra-short laser pulses. Subsequent microthermometric analyses determine the temperature at which the vapour bubble disappears again, the so-called liquid-vapour homogenisation temperature (Th(obs) ). The observed homogenisation temperature depends not only on the water density but also on the inclusion volume. In order to determine the water density, a thermodynamic model is used that takes account of the effect of surface tension on Th(obs) to calculate Th∞. This is the corresponding homogenisation temperature at saturation pressure that determines the water density and defines the formation temperature of the fluid inclusion. The analytical precision of the method ranges between 0.1 and 0.3 °C depending on the size of the inclusions.
Luminescence-encoded microbeads are important tools for many applications in the life and material sciences that utilize luminescence detection as well as multiplexing and barcoding strategies. The preparation of such beads often involves the staining of premanufactured beads with molecular luminophores using simple swelling procedures or surface functionalization with layer-by-layer (LbL) techniques. Alternatively, these luminophores are sterically incorporated during the polymerization reaction yielding the polymer beads. The favorable optical properties of semiconductor quantum dots (QDs), which present broadly excitable, size-tunable, narrow emission bands and low photobleaching sensitivity, triggered the preparation of beads stained with QDs. However, the colloidal nature and the surface chemistry of these QDs, which largely controls their luminescence properties, introduce new challenges to bead encoding that have been barely systematically assessed. To establish a straightforward approach for the bead encoding with QDs with minimized loss in luminescence, we systematically assessed the incorporation of oleic acid/oleylamine-stabilized CdSe/CdS-core/shell-QDs into 0.5–2.5 μm-sized polystyrene (PS) microspheres by a simple dispersion polymerization synthesis that was first optimized with the organic dye Nile Red. Parameters addressed for the preparation of luminophore-encoded beads include the use of a polymer-compatible ligand such as benzyldimethyloctadecylammonium chloride (OBDAC) for the QDs, and crosslinking to prevent luminophore leakage. The physico-chemical and optical properties of the resulting beads were investigated with electron microscopy, dynamic light scattering, optical spectroscopy, and fluorescence microscopy. Particle size distribution, fluorescence quantum yield of the encapsulated QDs, and QD leaking stability were used as measures for bead quality. The derived optimized bead encoding procedure enables the reproducible preparation of bright PS microbeads encoded with organic dyes as well as with CdSe/CdS-QDs. Although these beads show a reduced photoluminescence quantum yield compared to the initially very strongly luminescent QDs, with values of about 35%, their photoluminescence quantum yield is nevertheless still moderate.
Validation of a fast and traceable radiographic scale calibration of dimensional computed tomography
(2022)
A fast and highly precise method of determining the geometrical scale factor of computed tomography (CT) measurements has been validated successfully by Bundesanstalt für Materialforschung und -prüfung (BAM), the Federal Institute of Metrology (METAS) and Physikalisch-Technische Bundesanstalt (PTB) within the scope of AdvanCT (Advanced Computed Tomography for dimensional and surface measurements in industry), a project funded in the European Metrology Programme for Innovation and Research (EMPIR). The method has been developed by PTB and requires only two radiographic images of a calibrated thin 2D standard (hole grid standard) from two opposite directions. The mean grid distance is determined from both radiographs. From this and with the help of the calibration result, the radiographic scale and therefore the voxel size is determined. The procedure takes only a few minutes and avoids a time-consuming CT scan. To validate the method, the voxel sizes determined via this method were compared with voxel sizes determined from CT scans of calibrated objects. Relative deviations between the voxel sizes in the range of 10−5 were
achieved with minimal effort using cone-beam CT systems at moderate magnifications.
Methodologies for model parameterization of virtual CTs for measurement uncertainty estimation
(2022)
X-ray computed tomography (XCT) is a fast-growing technology for dimensional measurements in industrial applications. However, traceable and efficient methods to determine measurement uncertainties are not available. Guidelines like the VDI/VDE 2630 Part 2.1 suggest at least 20 repetitions of a specific measurement task, which is not feasible for industrial standards. Simulation-based approaches to determine task specific measurement uncertainties are promising, but require closely adjusted model parameters and an integration of error sources like geometrical deviations during a measurement. Unfortunately, the development of an automated process to parameterize and integrate geometrical deviations into XCT models is still an open issue. In this work, the whole processing chain of dimensional XCT measurements is taken into account with focus on the issues and requirements to determine suitable parameters of geometrical deviations. Starting off with baseline simulations of different XCT systems, two approaches are investigated to determine and integrate geometrical deviations of reference measurements. The first approach tries to iteratively estimate geometric deviation parameter values to match the characteristics of the missing error sources. The second approach estimates those values based on radiographs of a known calibrated reference object. In contrast to prior work both approaches only use a condensed set of parameters to map geometric deviations. In case of the iterative approach, some major issues regarding unhandled directional dependencies have been identified and discussed. Whereas the radiographic method resulted in task specific expanded measurements uncertainties below one micrometre even for bi-directional features, which is a step closer towards a true digital twin for uncertainty estimations in dimensional XCT.
i-TRIBOMAT will provide the world's first Open Innovation Test Bed dedicated to analysing and simulating materials in tribological systems. In order to make necessary results of tribological tests comparable, harmonised ways to produce data are mandatory. Many sources influence the outcome of a Tribological test. Different approaches of institutes were evaluated in best practices via quality management tools minimising the impact on results.