Validation of artificial defects for Non-destructive testing measurements on a reference structure
(2018)
Non-destructive testing was established over the last decades as an important tool for assessing damages, material characterization and quality assurance in civil engineering. For example, Ground Penetrating Radar (GPR) can be used to scan large areas of concrete structures to determine the spatial position of the reinforcement. With the ultrasonic echo method, the thickness of concrete structures can be easily determined even if a high density of reinforcement is given. Various methods and processes have been developed for the validation of NDT procedures aiming at ensuring the quality of measurements in practical use. The Probability of Detection (POD) for example, is an available method to compare different technical devices with each other quantitatively regarding their performance. With this method, the best suited testing device for a specific inspection task under defined boundary conditions can be selected. By using the Guide to the Expression of Uncertainty in Measurement (GUM), it is possible to quantify the measurement uncertainty of an inspection procedure for a specific task. Another important aspect to improve the acceptance of non-destructive testing methods is the development of reference specimens.
Reference specimens serve for the calibration and further development of NDT methods under realistic conditions in different laboratories under the same conditions. This is an essential prerequisite for round robin tests. A particular challenge here is the most realistic representation of a damage that can occur at building sites. Possible damages include for example horizontal and vertical cracks or honeycombs in concrete. Such a reference structure was built for the development of a new design of power plant constructions. Comparative studies on the manufacturing of realistic honeycombs and delaminations were carried out in advance on a test specimen. The results of this study are presented here.
LAUS - Erste praktische Erfahrungen mit einem neuartigen Ultraschallsystem großer Eindringtiefe
(2018)
Konventionelle Systeme zur Ultraschall-Echo-Prüfung von Betonbauteilen sind in ihrer Eindringtiefe auf etwa einem Meter begrenzt. Zur Prüfung stärkerer Objekte war die Entwicklung eines neuartigen Prüfsystems notwendig. Das LAUS-System (Large Aperture UltraSound) besteht aus 12 einzelnen Arrays, die mit jeweils 32 Einzelprüfköpfen (Scherwellen, 25 – 50 kHz) als Sender oder Empfänger betrieben werden können. Sie werden unabhängig auf Betonoberflächen mit Unterdruck befestigt und kommunizieren drahtlos untereinander und mit der Zentraleinheit. Alle möglichen Kombinationen ergeben 132 Einzelmessungen, die zur Rekonstruktion des durchschallten Volumens genutzt werden. Mehrere dieser Datensätze lassen sich zu einer 3D-Auswertung kombinieren. Das System wurde an mehreren Testobjekten und Bauwerken erfolgreich erprobt. So konnte die fünf Meter dicke, sehr stark bewehrte Fundamentplatte des Fallturms auf dem BAM-Testgelände bei Horstwalde durchschallt werden. Ein zweites Beispiel ist die erfolgreiche Detektion von Spannkanälen in 1,8 m Tiefe in einem massiven Brückenbauwerk.
Foundations
(2018)
The non-destructive testing methods available for civil engineering (NDT-CE) enable the measurements of quantitative parameters, which realistically describe the characteristics of existing buildings. In the past, methods for quality evaluation and concepts for validation expanded into NDT-CE to improve the objectivity of measured data. Thereby, a metrological foundation was developed to collect statistically sound and structurally relevant information about the inner construction of structures without destructive interventions. More recently, the demand for recalculations of structural safety was identified. This paper summarizes a basic research study on structural analyses of bridges in combination with NDT. The aim is to use measurement data of nondestructive testing methods as stochastic quantities in static calculations. Therefore, a methodical interface between the guide to the expression of uncertainty in measurement and probabilistic approximation procedures (e.g. FORM) has been proven to be suitable. The motivation is to relate the scientific approach of the structural analysis with real information coming from existing structures and not with those found in the literature. A case study about the probabilistic bending proof of a reinforced concrete bridge with statistically verified data from ultrasonic measurements shows that the measuring results fulfil the requirements concerning precision, trueness, objectivity and reliability.
The LAUS: First applications of a new system for ultrasonic imaging of very concrete structures
(2018)
The LAUS (Large Aperture Ultrasonic System) has been developed to image very thick concrete structures, which are not accessible for commercial systems. The device and the corresponding software is the result of joint research of BAM, an ultrasonic instrument manufacturer and University of Kassel, Germany. It consists of 12 separate arrays of 32 point-contact shear wave transducers each, which can be deployed in flexible configurations. Each array is combined with battery and transmitter, receiver and wireless communication electronics.
Three case histories are presented. First the system was deployed on a 5-m thick heavily reinforced foundation slab. The reflection of the slab’s bottom was imaged clearly. In addition, a multiple reflection was registered, thus giving hope that even thicker elements might be imaged by the instrument. Second, the LAUS was used to investigate a massive bridge girder where a heavy rainstorm during concreting had led to imperfections that were visible after removing the formwork was removed. The LAUS could image tendon ducts in 1.8m depth and the backwall closely behind them. Some limited areas showed blurred reflections and were checked by drill holes; these areas were affected by diffuse damage which could be repaired by injections. Third, a large retaining wall was checked for thickness.
Meanwhile, the LAUS has been used in underground waste deposits (nuclear and other) for quality assurance of sealing plugs. A confirmed penetration depth of about 7 m has been reached.
Das Ultraschallprüfverfahren wird im Bauwesen für die zerstörungsfreie Prüfung von Bauwerken eingesetzt, insbesondere für Strukturuntersuchungen. Dadurch sollen Lage und Größe von Bauschäden detektiert werden, um geeignete und kostengünstige Sanierungsmaßnahmen ergreifen zu können. Da in der Praxis meist nur eine einseitige Zugänglichkeit gegeben ist (z. B. Betonverschalung eines Tunnels), wird im Impuls-Echoverfahren gemessen. Dies bedeutet, dass ein Ultraschallsignal erzeugt und dessen Echo aufgenommen wird. Prüfköpfe, welche einen Oberflächenkontakt benötigen, erhöhen die benötigte Messzeit dramatisch. Mittels luftgekoppeltem Ultraschall können viele naupraktische Problem umgangen werden und die Messzeit kann deutlich reduziert werden. Als Möglichkeit zur Anregung eines luftgekoppeltem Ultraschallsignals werden fluidische Bauteile diskutiert
The ageing and decommissioning of nuclear concrete infrastructure (e. g. safety containments) as well as the building and closure of waste repositories gives new challenges to non-destructive testing. For example, the quality assurance of very thick concrete structures is beyond the limitations of commercial ultrasonic instrumentation.
The presentation introduces typical testing tasks and the application of state of the art NDT techniques. In addition, it describes some new developments in ultrasonic testing and monitoring. Specifically, the application of the unique deep penetration system LAUS is shown. Ultrasonic monitoring using embedded transducers to check for subtle and sudden changes in the material is introduced as well.
Measuring means knowing. The structural engineer’s Knowledge about structures is vitally important for the assessment of their structural safety. This contribution shows, how non-destructive testing methods can be used to collect valuable Information about existing structures. This value is expressed in this paper by the usability in probabilistic assessments and thus by the reliability of the information. The development of non-destructive testing methods in civil-engineering allows the realistic measurement and visualization of inner constructions of concrete components with a minimum of destructive interventions.
The evaluation of the quality of measurement data is of fundamental importance for quantitative measurements in order to ensure the objectivity of testing and evaluation and to assess the reliability of the knowledge acquired. Both systematic and random deviations must be identified, quantified and taken into account to obtain statistically sound data. The Focus of this contribution is on the methodical path, how displayed measurement data can be processed into reliable knowledge.
It is not about developing assessment methods but about providing
necessary knowledge to increase their operational usability.
Lock-in- and flash thermography are standard methods in active thermography. They are widely used in industrial inspection tasks e.g. for the detection of delaminations, cracks or pores. The requirements for the light sources of these two methods are substantially different. While lock-in thermography requires sources that can be easily and above all fast modulated, the use of flash thermography requires sources that release a very high optical energy in the very short time.
By introducing high-power vertical cavity surface emitting lasers (VCSELs) arrays to the field of thermography a source is now available that covers these two areas. VCSEL arrays combine the fast temporal behavior of a diode laser with the high optical irradiance and the wide illumination range of flash lamps or LEDs and can thus potentially replace all conventional light sources of thermography.
However, the main advantage of this laser technology lies in the independent control of individual array areas. It is therefore possible to heat not only in terms of time, but also in terms of space. This new degree of freedom allows the development of new NDT methods. We demonstrate this approach using a test problem that can only be solved to a limited extent in active thermography, namely the detection of very thin, hidden defects in metallic materials that are aligned vertically to the surface. For this purpose, we generate destructively interfering thermal wave fields, which make it possible to detect defects within the range of the thermal wave field high sensitivity. This is done without pre-treatment of the surface and without using a reference area to depths beyond the usual thermographic rule of thumb.
Metallische Druckgefäße werden aus Gründen der Gewichtseinsparung zunehmend durch Composite-Druckgefäße ersetzt. Während der Alterungsprozess bei metallischen Druckgefäßen durch Wöhlerkurven hinreichend beschrieben wird, ist der Alterungsmechanismus bei Composite-Druckgefäßen noch nicht vollständig geklärt. Im Rahmen des BAM-interne Themenfeldprojekts COD-AGE werden mit diversen Verfahren alterungsbegleitende, zerstörungsfreie Prüfungen an Composite-Druckgefäßen durchgeführt. Im ersten Teil dieses Vortrages werden Ergebnisse der konventionellen und hochfrequenten Wirbelstromprüfung vorgestellt.
Der zweite Teil des Vortrages beschäftigt sich mit der Prüfbarkeit von Kunststoffen aus Kunstharz und 3D-Druck mit dem Wirbelstromverfahren durch Zugabe ferromagnetischer Nanopartikel bzw. Verwendung von ferromagnetischem Filament.
Metallische Druckgefäße werden aus Gründen der Gewichtseinsparung zunehmend durch Composite-Druckgefäße ersetzt. Während der Alterungsprozess bei metallischen Druckgefäßen durch Wöhlerkurven hinreichend beschrieben wird, ist der Alterungsmechanismus bei Composite-Druckgefäßen noch nicht vollständig geklärt. Im Rahmen des BAM-interne Themenfeldprojekts COD-AGE werden mit diversen Verfahren alterungsbegleitende, zerstörungsfreie Prüfungen an Composite-Druckgefäßen durchgeführt. Nach einem kurzen Überblick über die BAM und den FB 8.4 werden zunächst die allgemeine Funktionsweise der Wirbelstromprüfung und die bildgebende Wirbelstromprüfung erklärt. Anschließend werden Ergebnisse der konventionellen und hochfrequenten Wirbelstromprüfung vorgestellt.
Der letzte Teil des Vortrages beschäftigt sich mit der Prüfbarkeit von Kunststoffen aus Kunstharz und 3D-Druck mit dem Wirbelstromverfahren durch Zugabe ferromagnetischer Nanopartikel bzw. Verwendung von ferromagnetischem Filament.
Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for evaluation of material defects. Material defects are often simulated by flat-bottom holes (FBH) or grooves. Typically, analytical 1D models are used to determine the defect depth of FBHs, grooves or delaminations. However, these models cannot take into account lateral heat flows, or only to a limited extent (semi-empirical model). Their applicability is therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Additionally, the surfaces of semi-transparent materials have to be blackened to absorb the radiation energy on the surface of the material. Without surface coatings, these models cannot be used for semi-transparent materials. Available 1D analytical models for determination of sample or layer thicknesses also do not take into account lateral heat flows.
Here, we present an approach for quantitative determination of the geometry of FBHs or grooves in semi-transparent materials by considering lateral heat flow. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a FBH or groove and its diameter or width, respectively. The model considers semi-transparency of the sample within the wavelength range of the excitation source as well as of the IR camera and thermal losses at its surfaces. Heat transport by radiation within the sample is neglected. It supports the use of an arbitrary temporal shape of the heating pulse to properly describe the measurement conditions for different heat sources.
Iterative numerical 2D-modeling for quantification of material defects by pulsed thermography
(2018)
Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for examination of material defects. Typically, analytical 1D models are used to determine the defect depth of flat-bottom holes (FBH), grooves or delamination. However, these models cannot take into account lateral heat flows, or only to a limited extent. They are therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Here, we present an approach for quantitative determination of the geometry for FBH or grooves. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a groove or FBH and its diameter of width. The model takes lateral heat flows into account as well as thermal losses. Figure 1 shows the temperature increase of a pulsed thermography measurement at three different locations on the sample. The numerical model is fitted to the experimental data (red lines) to quantify the groove. The numerical simulation matches the experimental data well.
More than 80 representatives of SMEs, industrial companies and research institutes met on September 12 at the workshop "Challenges in Additive Manufacturing: Innovative Materials and Quality Control" at BAM in Adlershof to discuss the latest developments in materials and quality control in additive manufacturing.
In special lectures, researchers, users and equipment manufacturers reported on the latest and future developments in additive manufacturing. Furthermore, funding opportunities for projects between SMEs and research institutions on a national and European level were presented.
The CLEAN ENERGY Flagship is an initiative designed to utilize recent game changing developments in digital, materials and manufacturing technologies to catalyze a radical paradigm shift towards clean, reliable, efficient and cost-optimal energy.
Unifying and drastically accelerating radically new energy material design, processing and integration across the entire value chain addressing energy production, conversion, storage and systems.
CLEAN ENERGY participants are all distinguished research organisations that each benefit from their own industry networks and contacts with regions and state-level activities and have a long history of collaborating with each other (for 10 years now under the umbrella of EERA) within a European collaborative framework.
Through EERA, CLEAN ENERGY aims to become a crucial partner in the SET-Plan, supporting long-lasting approaches through its established networks and internal collaborations.
Composite pressure vessels consist of an internal liner (Steel, aluminum, or plastic) which stores the liquid or gas and CFRP (carbon fiber reinforced plastics) which serves as pressure resistance. These vessels comprise some advantages compared with conventional vessels made of steel or aluminum and their application grew strongly over the last decade. The reason for this trend is the tremendous weight saving.
However, the long-time behavior for filling and discharging cycles and the creep strength of composite vessels is not fully understood. Therefore, BAM started an internal project to investigate degradation of these material systems. Normally, high-frequency eddy current testing (HF-ET, f > 10 MHz) is deployed for CFRP due to the low conductivity of the fibers, which is in the order of 0.01 MS/s, and the capacitive coupling between them. Nevertheless, in some cases conventional ET can be applied.
Some first results using conventional ET for detecting leakages in the internal liners are already presented. This contribution gives an update of our investigation using both conventional and high-frequency ET. Therefore, we developed an ET equipment based on a vector network analyzer using frequencies between 300 kHz and 2 GHz. The focus concerns the study of the aging effects.
In flash thermography, the temperature transient is strongly influenced by the temporal shape of the heating pulse for samples with high thermal diffusivity or very thin samples. Here, we present a closed phenomenological approximation of the temporal shape of pulses of Xe-flash lamps. It is a non-stitched solution, has a simple Laplace transform and is suitable for different lamps and energy settings. It is demonstrated that simulated temperature transients, based on this approximation, are well consistent with experimental data.
Die Varroose gilt weltweit als eine der bedeutendsten Erkrankungen der westlichen Honigbiene, Apis mellifera. Verursacht wird sie durch den Ektoparasiten Varroa destructor, der durch Saugen der Hämolymphe und Virenübertragung sowohl die Bienenbrut als auch die adulten Individuen schädigt.
Ohne imkerliche Unterstützung gehen betroffene Bienenvölker in der Regel innerhalb von drei Jahren ein. Als bewährte, häufige Behandlung wird flächendeckend 60%ige Ameisensäure (AS) -im Bienenstock appliziert über verschiedene Verdampfungssysteme- eingesetzt. Sie wirkt als einziger zugelassener Wirkstoff gegen die Varroamilbe auch in die verdeckelte Brut hinein und birgt kein Risiko der Resistenzentwicklung.
Allerdings ist das therapeutische Fenster, der Bereich zwischen Milbenabtötung und Bienenschädigung, relativ schmal und die tatsächliche AS-Konzentration im Bienenstock stark abhängig von äußeren Einflussfaktoren, wie Temperatur oder Applikationsart.
Eine Bestimmung der exakten AS-Konzentration im Bienenstock ist also notwendig, um einerseits das Wirkungsoptimum zu bestimmen und andererseits bei Übersteigen der Maximalkonzentrationen mit Folge-Schädigung der Bienen, ein rechtzeitiges Eingreifen der Imker zu ermöglichen.
Die Entwicklung eines Detektors zur Bestimmung der tatsächlichen AS-Konzentration in der Bienenstockluft würde einen großen Fortschritt in den Bereichen der Bienenforschung, der Varroa-Behandlung in der Imkerei, sowie einer gesundheitlich bedenklichen AS-Exposition für den Imker bedeuten.
Langfristiges Ziel dieses Projekts ist es, ein mobiles, einfach handhabbares Gerät zur Detektion der AS-Konzentration in der Bienenstock-Luft während einer AS-Behandlung zu entwickeln.
Grundlage hierfür bietet ein kommerziell verfügbares Multigassensorsystem (PEN3, AIRSENSE Analytics GmbH, Schwerin).
Ziel der beschriebenen Vorversuche ist die generelle Eignungsprüfung des Multigassensorsystems PEN3 zur Detektion der hohen AS-Konzentration in Gasgemischen unter Bedingungen wie sie im Bienenstock während einer AS-Behandlung herrschen.
Als Messplatz zur Detektion von AS in Luft wurden zwei Systeme vorbereitet:
A) Eine Plexiglasbox mit einem Volumen von ca.1,9 l diente als Prüfkammer, wurde von einem Gasstrom befeuchteter synthetischer Luft durchströmt (50 mL min-1, 100 mL min-1 oder 300 mL min-1) und zur Temperierung auf 25 °C auf einer Heizmatte bzw. auf 35 °C in einem Ofen platziert. AS-Wasser-Gemische verschiedener Volumenverhältnisse (0-100%) wurden in einer Glasschale (Oberfläche Flüssigphase 9,6 cm2) in der Prüfkammer vorgelegt.
B) In einer durch eine Heizmatte auf 25 °C temperierten, zwei-zargigen Segeberger Beute wurden vier Messpunkte angebracht (davon drei in der oberen und einer in der unteren Etage) und 60%ige AS über einen Nassenheider-Verdampfer vertikal vorgelegt.
Zur Detektion des AS-Luft-Gemischs wurde das PEN3 Multigassensorsystem genutzt. Das zu untersuchende Gasgemisch wurde über die internen zehn Metalloxid-Halbleiterdetektoren (1-10) der PEN3 geleitet. Das so generierte Messsignal beschreibt ein Widerstandsverhältnis zwischen dem Widerstandwert zum Zeitpunkt der Messung (R) und dem elektrischen Widerstand bei der Nullluft-Messung (R0), wobei hier befeuchtete synthetische Luft mit einer reltativen Feuchte von 49 % ± 4 % oder Raumluft genutzt wurde. Gase unterschiedlicher Zusammensetzung können anhand der dargestellten Signalmuster verschiedener Sensoren voneinander unterschieden werden.
In beiden Messsystemen wiesen die Sensorelemente 1, 6, 7, 8 und 9 gesteigerte Sensitivitäten beim Vorliegen von Ameisensäure im Gasgemisch auf. Die größten Widerstandsverhältnisse zeigten dabei die Sensorelemente 6, 8 und 9, sodass hier von der höchsten Empfindlichkeit für AS auszugehen ist.
Basierend auf den erhobenen Messdatensätzen wurden Hauptkomponenten- (PCA) und lineare Diskriminanzanalysen (LDA) zur Dimensionsreduktion durchgeführt, um charakteristische Muster aus den Messsignalen zu extrahieren. Die PCA- und LDA-Plots für die jeweils bedeutsamsten Komponenten PC 1 und PC 2 bzw. LD 1 und LD 2 eines Versuchslaufs in der Plexiglasbox (A) bei einer Temperatur von 35°C, einem Volumenstrom von 300 mL min-1 und variablen Ameisensäure-Wasser-Volumenverhältnissen von 0 % bis 100 %. Deutlich erkennbar sind die Abhängigkeiten der Komponenten PC 1 und LD 1 (Abszissen) vom vorgelegten AS-Wasser-Volumenverhältnis. Unsere Ergebnisse zeigen, dass das Multigassensorsystem zur Bestimmung von AS in Luft unter ähnlichen Bedingungen wie bei einer AS-Behandlung im Bienenstock angewandt werden kann.
Die Versuche zeigen, dass die im PEN3 eingesetzten Metalloxid-Sensoren bzw. Metalloxidsensor-Arrays zur Detektion von AS in Luft auch bei höheren Konzentrationen als beispielsweise der MAK-Wert von 5 µmol/mol zur Überwachung des AS-Gehaltes in Bienenstöcken angewandt werden können. Aufgrund der Möglichkeit der quasi Echtzeit-Messdatengenerierung, der geringen Kosten kommerziell verfügbarer Sensorelemente, der Portabilität und der Möglichkeit zur Miniaturisierung zeichnen sich solche Messsysteme zukünftig durch eine besondere Praxisnähe aus. Diese Erkenntnisse sind Grundlage für eine Verbesserung des Detektionsverfahrens und zur Vorhersage über die Effizienz und Effektivität der Varroha-Milbenbehandlung.
In this paper, we introduce a nano aerial robot swarm for Indoor Air Quality (IAQ) monitoring applications such as occupational health and safety of (industrial) workplaces. The robotic swarm is composed of nano Unmanned Aerial Vehicles (UAVs), based on the Crazyflie 2.0 quadrocopter, and small lightweight Metal Oxide (MOX) gas sensors for measuring the Total Volatile Organic Compound (TVOC), which is a measure for IAQ. An indoor localization and positioning system is used to estimate the absolute 3D position of the swarm similar to GPS. A test scenario was built up to validate and optimize the swarm for the intended applications. Besides calibration of the IAQ sensors, we performed experiments to investigate the influence of the rotor downwash on the gas measurements at different altitudes and compared them with stationary measurements. Moreover, we did a first evaluation of the gas distribution mapping performance. Based on this novel IAQ monitoring concept, new algorithms in the field of Mobile Robot Olfaction (MRO) are planned to be developed exploiting the abilities of an aerial robotic swarm.
Leitungswasserschäden nahmen im Jahr 2016 mit rund 2,6 Milliarden Euro den größten Posten bei Gebäudeversicherungen ein. Die Bestimmung und Lokalisierung des Schadensausmaßes ist dabei ein erster wichtiger Schritt, um die erforderlichen Sanierungsarbeiten abschätzen und effizient vornehmen zu können. Hierfür sind Radar und Neutronensonden bereits etablierte Verfahren. Für verlässliche Aussagen zum quantitativen Feuchtegehalt eines Baustoffes werden jedoch zerstörende Sondierungsbohrungen zur Kalibrierung der aufgenommenen Daten benötigt. Dieser hohe zeitliche und finanzielle Aufwand soll zukünftig durch den parallelen Einsatz der genannten Messverfahren verhindert werden.
In der durchgeführten Studie wurden Estrichprobekörper auf Zement- und Anhydritbasis mit variablen Dicken und Festigkeiten hergestellt und deren Austrocknung mit Radar und Neutronensonde über einen Zeitraum von 90 Tagen beobachtet. Als Referenzverfahren zur Ermittlung des Feuchteverlaufs dienten die gravimetrische Darr- und chemische Calcium-Carbid-Methode, welche an kleineren Schwesterproben der gleichen Charge angewendet wurden. Kontinuierliche Wägungen der größeren Probekörper gaben hierbei Aufschluss über den durch Austrocknung schwindende Wasseranteil.
Aus dem aufgenommen Radardatensatz konnten anschließend markante Signalmerkmale im Zeit- und Frequenzbereich extrahiert und deren Zusammenhang zum Feuchtegehalt der Estrichtypen untersucht werden. Hierbei wurden gängige Methoden aus der Literatur zur Feuchtemessung mit Radar angewandt, wobei die Kombination dieser und das Hinzuziehen der Neutronensonde mittels Datenfusion zu einem höheren Informationsgehalt beiträgt. Somit kann eine zerstörungsfreie Quantifizierung des Feuchteschadens an schwimmenden Fußbodenaufbauten vorgenommen werden
Das Projekt befasst sich mit einem neuen Ansatz, den pH-Wert im Beton zu bestimmen.
Der pH-Wert ist vor allem für Stahlbeton-Bauwerke von Bedeutung, da dieser maßgeblich die Korrosion des Stahls beeinflusst. Im frischen Beton liegt der pH-Wert im basischen Bereich.
Der Stahl ist in diesem Bereich passiviert, also vor schädlicher Korrosion geschützt. Durch die sogenannte Karbonatisierung sinkt der pH-Wert und die Korrosionswahrscheinlichkeit steigt deutlich an. Die Stabilität von Bauwerken in denen Stahlbeton verbaut ist, wird durch diese Korrosion langfristig beeinträchtigt. Allein in deutscher Infrastruktur rechnet man mit circa 5 Milliarden Euro Schaden jährlich.
Die entwickelte Methode verwendet Sonden, welche die Korrosion Monitoren sollen. Im Sondeninneren befindet sich eine Schicht pH-Indikator (Thymolblau) und eine Schicht mit Quantenpunkten. Die Quantenpunkte fluoreszieren, nach Anregung durch zum Beispiel einen Laser, bei circa 440 nm (blau) beziehungsweise 610 nm (gelb-orange). Das Thymolblau ist im basischen Milieu (pH > 9,6) blau, im neutralen Milieu (um pH 7) gelb-orange. Der Indikator wirkt wie ein Farbfilter und lässt, je nach pH-Wert, unterschiedliche Wellenlängen zur Glasfaser durch. Aus der gemessenen Intensität bei 440 nm und 610 nm kann ein Verhältnis ermittelt werden. Dieses Verhältnis lässt erkennen, welchen pH-Wert das Milieu besitzt, in dem sich die Sonde befindet.
Die entwickelte Methodik ist zerstörungsfrei, das heißt kein Material muss aus den Bauwerken entnommen werden. Vielmehr sollen die Sonden beim Betonieren in das Bauwerk eingebettet werden. Über Glasfasern können die Sonden jederzeit angesprochen werden. Dies ermöglicht permanentes pH-Monitoring, was die Früherkennung von Korrosionsgefahr verbessert und die Sanierungskosten verringert.
The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiographic process of industrial radiology. In this contribution we focus on virtual computer tomography, the simulation of tomographic scans. The possibilities to simulate complex scanning trajectories are shown in combination with the tomographic reconstruction using individual projection matrices.
Remote gas sensors like those based on the Tunable Diode Laser Absorption Spectroscopy (TDLAS) enable mobile robots to scan huge areas for gas concentrations in reasonable time and are therefore well suited for tasks such as gas emission surveillance and environmental monitoring.
A further advantage of remote sensors is that the gas distribution is not disturbed by the sensing platform itself if the measurements are carried out from a sufficient distance, which is particularly interesting when a rotary-wing platform is used.
Since there is no possibility to obtain ground truth measurements of gas distributions, simulations are used to develop and evaluate suitable olfaction algorithms.
For this purpose several models of in-situ gas sensors have been developed, but models of remote gas sensors are missing.
In this paper we present two novel 3D ray-tracer-based TDLAS sensor models. While the first model simplifies the laser beam as a line, the second model takes the conical shape of the beam into account.
Using a simulated gas plume, we compare the line model with the cone model in terms of accuracy and computational cost and show that the results generated by the cone model can differ significantly from those of the line model.
Issues that prevent Structural Health Monitoring (SHM) based on Guided Waves (GW) from being a part of today’s monitoring solutions in industry are not all obvious to the scientific community. To uncover and overcome these issues, scientists working on SHM and GW problems joined in an expert committee under the patronage of the German Society for Non-Destructive Testing. An initiated online survey among more than 700 experts and users reveals the hurdles hindering the practical application of GWbased SHM. Firstly, methods for proof of reliability of SHM approaches are missing.
Secondly, detailed understanding of phenomenological described wave-damage interactions is needed. Additionally, there are significant unsolved implementation issues and unsolved problems of signal processing including handling of environmental influences.
To enable substantial proof of reliability without unaffordable experimental effort also efficient simulation tools including realistic damage interaction are needed, enabling the joint use of experimental and simulated data to predict the capabilities of the Monitoring system. Considering these issues, the committee focusses on simulation, signal processing, as well as probability of detection and standardization. In the presented work, recent activities of the expert committee starting with survey results are summarized. An open access data basis of life-like measurements is presented to allow testing and comparison of signal processing and simulation algorithms. Finally, a strategy for efficient proof of reliability increasing the acceptance of SHM in industry and for successful Integration of SHM into real-world engineering structures is proposed.
3D images such as those produces by X-ray tomography can provide a wealth of information on the internal structure of materials, but quantification of specific geometrical or topological characteristics linked to some bulk physical property is far from being straightforward. This study focuses on methods to quantify the differences in physical properties as a function of direction, i.e. their anisotropy, and how it can be linked to measures of anisotropy of the internal structure of the material. The auto-correlation function gives a similarity measure in the volume as a function of distance and direction. This is a cross-correlation of the image with itself fast to compute and relatively insensitive to noise. It is why we focus on this method to compare with the physical property of our DPF material. Diesel Particulate Filter (DPF) materials are porous ceramics that; a) can be used at very high temperatures; b) have very good thermal shock resistance; c) are inert; d) can be manufactured with tailored porosity. Their usual way of production consists of the extrusion of a slurry into the desired filter shape, with successive ceramming at high temperature. This process causes anisotropy at both microscopic and macroscopic levels.
Der Beitrag beschreibt den Aufbau und die Entwicklung einer Heißluftquelle als Wärmequelle für die aktive Thermografie. Als Ausgangspunkt wird zunächst die Quellenlage betrachtet. In der Literatur über Thermografie spielt Heißluft als Wärmequelle nur in weniger als 0,1% eine Rolle, die Ursache dafür ist nicht bekannt. Es wird vermutet, dass dieser Erwärmungsmethode unterstellt wird, sie hätte Nachteile bezüglich Homogenität der Erwärmung sowie Leistungseintrag. In einer der raren Publikationen über einen Verfahrensvergleich schnitt die Heißluft-Thermografie jedoch nicht schlechter als die Vergleichsverfahren mit optischer Anregung ab, bei gleichzeitig deutlichem Zeitgewinn und geringerem technischen Aufwand.
Danach wird der fertige Versuchsaufbau mit seinen wesentlichen Komponenten dargestellt. Der Einfluss der Geometrie der Luftaustrittsdüse auf die erreichbare Wärmeverteilung an einem flachen Blech wurde an mehreren Düsen untersucht. Hierbei erwies sich eine langgestreckte Umlenkdüse mit einer Strahlumlenkung von etwa 20° als optimal zur Erzeugung einer möglichst homogenen Erwärmung.
Ein weiterer zu optimierender Parameter war die erreichbare Schaltdynamik des Heißgasstromes. Beim schnellen Schalten großer Volumenströme treten Druckstöße mit entsprechenden Temperaturänderungen auf. Hinzu kommt, dass der verwendete MFC (mass flow controller) bei großen Volumenströmen zum Einschwingen bei Schaltprozessen neigt.
Daher enthält der Aufbau einen offenen Bypass zur Stabilisierung des Volumenstroms. Mit dem so realisierten Messplatz wurde die Reproduzierbarkeit der erzielten Erwärmung durch mehrfache Wiederholungsmessungen über einen längeren Zeitraum untersucht. Hierzu wurde ein auch zu Validierungszwecken genutzter PVC-Block mit 13 mm Dicke jeweils für 60 s erwärmt und die Oberflächentemperatur des PVC-Blocks mit einer IR-Kamera aufgezeichnet. Bei jeweiligem Neuaufbau ohne Justierhilfe ergab sich eine Reproduzierbarkeit von etwa 22% bei 5 Versuchen. Unter Nutzung einer Justierhilfe (Schablone für Abstand in der Kamerasoftware) ließ sich die Reproduzierbarkeit auf 5% bei 7 Versuchen reduzieren.
Ein weiterer zu klärender Punkt war der erzielbare Wärmeeintrag im Vergleich zu einer Anregung mit Blitzlampen. Hierzu wurde eine Messung mit 60 s Heißluftheizung direkt mit einer Evaluierungsmessung mit Blitzlampen am gleichen PVC-Probekörper mit 4 FBB an der Rückseite verglichen. Die Inhomogenität der Erwärmung wurde durch eine Phasenauswertung unterdrückt. Die Phasenauswertung gestattete den Nachweis aller 4 FBB, wobei das Signal zu Rausch-Verhältnis bei der Heißlufterwärmung deutlich besser war. Der direkte Vergleich der Temperaturkurven zeigt, dass bei 60 s Heizlufterwärmung ca. 4,5 mal mehr Energie als bei der Blitzanregung vom Probekörper absorbiert wurde. Hieraus lässt sich die eingekoppelte Heizleistung mit 100 mW/cm² abschätzen. Das entspricht in etwa dem Niveau, wie es auch mit bewegten Halogenstrahlern, bewegten IR-Strahlern oder der Sonne erreicht wird.
Diese Ergebnisse belegen, dass eventuell vorhandene Vorbehalte gegenüber einer Heißluft als Wärmequelle für die aktive Thermografie zumindest für thermisch langsame Materialien wie Kunststoffe oder mineralische Baustoffe unbegründet sind. Die Einsatzgrenzen bei der Untersuchung thermisch schnellerer Materialien wie Metalle steht noch aus, hier ist mit Abstrichen zu rechnen. Auf der anderen Seite lässt eine mögliche Düsenoptimierung noch deutliche Verbesserungen erwarten.
Explosive spalling is caused by, among others, the thermohydraulic spalling mechanism. During this process, vaporization, dehydration, moisture-transport and condensation processes interact. As a result, a drying and dehydration zone as well as a saturated zone, known as a moisture clog, are observed inside the unilaterally-heated concrete. The presented research is focused on the experimental investigation of the underlying thermohydraulic processes.
To investigate these, a test methodology based on X-ray computed tomography (CT) and nuclear magnetic resonance (NMR) was developed. Thereby, the X-ray CT scans are carried out simultaneously during the application of a defined unilateral-heating regime on a specially-constructed specimen. This miniaturized specimen, equipped with a double-layer casing, reproduces the condition within a planar, unilaterally-heated building component.
A preliminary test methodology and the first experimental results were presented at the 5th International Workshop on Concrete Spalling in Borås, Sweden (2017). The contribution for the upcoming workshop presents an improved version of this test methodology and new results for a high-performance concrete (HPC) mixture exposed to temperatures up to 500 °C. Regarding the CT measurements, a higher time-resolution of 15 min was achieved and a quantification of the moisture changes was implemented. Due to an increase in signal quality of the NMR measurements, a pore-size specific moisture distribution can now be resolved. This allows to conclude about the moisture reconfiguration between small gel pores and larger interhydrate pores. Additionally, the NMR measurement are no longer limited to first 2.5 cm below the heated surface but a one-dimensional moisture distribution can now be estimated over the whole 10 cm long specimen.
The presented results demonstrate that the combination of X-ray CT and NMR measurements enables to image and quantify the thermally-induced moisture transport and reconfiguration from small gel pores up to macro pores. This provides important insights into the thermohydraulic damage mechanism and leads to a better understanding of spalling avoidance strategies, like the addition of polypropylene fibres.
An essential task in many industries, e.g. food, petrol or chemical industry, is the precise and accurate characterization of liquids. Therefore, the development of innovative in-line sensors is of great interest. New concepts based on periodic structures, so-called phononic crystals (PnCs), are an interesting idea for the design of innovative sensors.
A PnC-based sensor can be designed by introducing a resonance inside a bandgap, a frequency region where no wave propagation is allowed. High-Q measurement systems using PnCs are already reported in the literature. However, existing designs cannot be implemented into a piping system directly, but need special fittings, openings or by-passes to be in contact with the liquid.
To circumvent this issue, we develop a new sensor based on PnCs, which can be directly implemented as part of the piping system. For this purpose, we use a PnC consisting of hollow cylinders with a periodic change of the outer diameter.
A bandgap could be found for the described geometry without fluid in simulation and measurement. However, simulations show, that a bandgap for fluid-filled cylinders can only be obtained for quasi-longitudinal modes. Hence, we propose a mode selective excitation for the sensor.
The application of phased arrays in either linear or matrix arrangement in combination with signal processing opens the door for the mechanized inspection of different thin wall materials itself as well as their joining methods.
Modern lightweight components are typically manufactured by a composition of different types of e.g. steels, metals, fiber reinforced plastics and glass. Dependent on the material combinations e.g. welding, brazing, bonding, cladding or coating may be applied during the manufacturing process to join different semi-finished products to form the component.
The resulting complex material composition and different damage mechanisms pose new challenges to non-destructive testing with ultrasound due to the different material properties and the overall arrangement of the materials employed.
The sound field variation capabilities of array probes may be helpful to overcome some of these challenges if adapted to the specific inspection task.
Examples for the non-destructive mechanized phased array inspection of different types of materials and joining methods will be presented.
Recently, various guided wave tomography algorithms have been developed to map structural changes from remote locations. The focus has been on structures made of isotropic materials and little work has been done on structures made of anisotropic materials. Primary complication to implement tomography in composite laminates is associated with the complex forward model to accurately simulate the 3-D guided wave propagation. In this study, we demonstrate that guided wave propagation can be approximated by an equivalent 2-D acoustic model. It is based on finite-difference discretization method in which the wave-field is parameterized by phase velocity and dimensionless anisotropic parameters. The reconstruction of defects is based on a full-waveform inversion algorithm and was implemented on the data obtained from finite element simulations. Results on a localized stiffness defects in composite plates with various layups demonstrate the attractiveness of the proposed methodology.
This PhD project is part of the Marie Skłodowska-Curie International Training Network MUMMERING. The overarching goal of MUMMERING is the creation of a research tool that exploits the wealth of 3D imaging modalities applied in materials engineering.
The focus of this work is advanced reconstruction algorithms. The primary objective is the development and implementation of the DIRECTT algorithm. Due to restrictions introduced by the sample or the imaging setup during a measurement, it is not always possible to acquire data that fulfil the Nyquist sampling criterion. The DIRECTT algorithm is intended to produce reconstructions of superior quality for such cases of limited data sets, compared to those of other available algorithms, such as algebraic iterative ones. Although DIRECTT has been developed primarily for the reconstruction of volumes from data acquired by an X-ray Computed Tomography scanner, it can also be applied to the different modalities, such as laminography.
The talk describes the reconstruction principle of DIRECTT. Furthermore, reconstructions of measured data are presented and compared to reconstructions produced by other established algorithms.
Metallische Mikropartikel in der Größenfraktion von ca. 10 – 100 Mikrometer bilden das Grundmaterial für den additiven Aufbau komplexer Strukturen durch lokales Aufschmelzen mit einem Laserstrahl. Entscheidend für dieses Verfahren ist die Kenntnis der Größen-, Form- und Defektverteilungen von Partikelfraktionen, da sie direkten Einfluss auf die Fließfähigkeit des Pulvers während des lagenweisen Auftragens, als auch auf die finale innere Porosität des Bauteils haben. Im Pulver vorhandene Poren verlassen in der Regel das Schmelzbad vor dem Erstarren nicht wieder, da deren Konvektionszeiten größer sind als die Zeit, während der das lokale Schmelzbad besteht, so dass einmal durch die Ausgangspartikel eingebrachte Poren in der Regel auch im fertigen Bauteil verbleiben. Eine strenge Qualitätskontrolle des Ausgangspulvers ist also Voraussetzung, um hochwertige Bauteile mit geringer Restporosität zu erhalten. Der Vorteil der Röntgentomographie ist dabei, dass mit nur sehr geringem Präparationsaufwand innenliegende Poren bis zu einem Durchmesser von wenigen Mikrometern detektiert werden können. Dies ist mit konkurrierenden Verfahren (Licht- / Elektronenmikroskopie, Laserbeugung) so nicht möglich. Zusammenfassend werden wir zeigen, dass die zerstörungsfreie Bildgebung mit der Röntgen-Mikrotomographie für die Qualitätskontrolle in der additiven Fertigung ein leistungsfähiges Werkzeug ist. Wir erörtern die Grenzen der Methode durch eine numerische Studie mithilfe des Simulationsprogramms aRTist. Dabei werden verschiedene Partikelgrößen dahingehend untersucht, welche Poren mit mikroradiographischen Verfahren detektierbar sind. Dazu wird ein Modell für eine dreilagige dichteste Kugelpackung entwickelt, so dass auch Überlagerungen von Anzeigen untersucht werden können. Im Ergebnis werden verschiedene Partikel- und Porengrößenkombinationen untersucht und die entsprechenden Detektionsgrenzen bestimmt.
Neben der klassischen Durchstrahlung wird die bildgebende Röntgen-rückstreuung bisher nur sehr begrenzt eingesetzt. Vor über 20 Jahren hatte Philips mit „COMSCAN“ eine erste industrielle Anwendung in der Luftfahrt gefunden, die sogar eine Tiefenauflösung besaß. Die Firma AS&E in Boston bietet Röntgenrückstreu-Anlagen für den Sicherheitsbereich an. In diesen wird mit einem hochkollimierten Nadelstrahl aus einem rotierenden Blendenrad ein Objekt einseitig abgetastet. Zur Detektion der gestreuten Strahlung aus dem Objekt werden großflächige Detektoren direkt neben dem rotierenden Nadelstrahlkollimator eingesetzt. Ein solcher Prototyp wird an der BAM für den Einsatz in der zerstörungsfreien Prüfung untersucht und optimiert. Als neues industrielles Einsatzgebiet wird dabei die in situ Überwachung in der additiven Fertigung avisiert. Hier ist die Zugänglichkeit zum entstehenden Werkstück in den 3D-Druckanlagen stark eingeschränkt, was den Einsatz einer zweiseitigen Durchstrahlung oder der Computer-Tomographie, bei der das Objekt rotiert wird, verhindert. Auch sind die in der additiven Fertigung eingesetzten Werkstoffe (Polymere, Keramik, Leichtmetalle wie Al oder Ti) für die Rückstreuung besser geeignet als Metalle höherer Dichte, da das Streusignal mit der Ordnungszahl und der Materialdichte abnimmt. Allerdings sind die Anforderungen an räumliche Auflösung und Kontrastempfindlichkeit in der zerstörungsfreien Prüfung additiv gefertigter Bauteil deutlich höher als im Sicherheitsbereich, da hier Bauteilfehler mit typischen Dimensionen kleiner als 1 mm sicher detektiert werden müssen. Die Untersuchung dieser Grenzen des derzeitigen Standes der Röntgenrückstreutechnik mit Nadelstrahl ist ein Teilbereich des mehrjährigen BAM-Themenfeldprojektes „ProMoAM“. Im Vortrag werden die ersten Ergebnisse der Optimierung sowie die gefundenen Anwendungsgrenzen an Beispielen erläutert.
Neues aus der BAM 2019
(2019)
X-ray back scatter imaging is rarely applied compared to classical X-ray projection imaging. More than 20 years ago the company Philips developed “COMSCAN”, a first application case for aircraft industry, which allowed even a depth resolution using back scatter imaging. The company AS&E in Boston offers back scatter imaging solutions for the security market. The principle is to scan the object with a highly collimated X-ray needle beam from one side only and to detect the backscattered radiation by a large area detector side by side with the collimation wheel. A new prototype is investigated at BAM for application and optimization in non-destructive testing. As modern industrial application field in-situ inspection in additive manufacturing is targeted. The accessibility of the printed part during the production process is very limited. This prevent the application of a two sided X-ray inspection or Computed Tomography, were an rotation of the object is required to acquire projections from 360 degrees. An important advantage for the X-ray back scatter technique are also the materials used in additive manufacturing (polymers, ceramics, light metals like Aluminum or Titanium). These materials with lower density and lower Z values give better scatter signals than metals with higher densities and Z values. The back scatter intensity decreases with increasing density and Z value of the material. But the requirements on spatial resolution and contrast sensitivity are more stringent for non-destructive testing of additive manufactured parts compared to the security area. In NDT sizes of indications smaller than 1 mm have to be detected clearly. The investigation of these limits on a state-of-the-art prototype for X-ray back scattering using rotating collimated X-ray needle beams is a part of the BAM project “ProMoAM”. The contribution shows first results of the optimization for NDT and the achieved application limits for several example cases.
X-Ray Computed Tomography (CT) is applied in industry for flaw detection, flaw evaluation and dimensional measurement. This requires the correct CT system settings for sufficient visibility and detectability of flaws and structure elements. The visibility of indications for human observers on a monitor depends on the square root of the reconstructed flaw area (here pores with diameter < ½ inch) in the cross sectional 2D images, the Contrast to Noise Ratio (CNR) and the Modulation Transfer Function (MTF). This applies also to 2D-projections, meaning also to “normal” digital radiographs. The ASTM guide E 1441 describes three essential functions for prediction of the visibility of small circular indications in slice images of a 3D reconstruction or a 2D reconstruction. This is the Contrast Discrimination Function (CDF), the MTF (see also the revision of ASTM E 1695), and the Contrast Detail Dose (CDD) function. The prediction of the visibility of circular indications in reconstructed slice images can be determined from the Contrast Detail Dose function, which is the combination of CDF and MTF and a physiological factor c. The measurement procedures and formulas for the prediction of the detail visibility by CDD will be corrected, tested and verified by modelling and in a Round Robin Test with modern commercial 3D CT systems of different manufacturers. Conclusions will be reported and recommendations will be given for the correct psychological factor c and the consideration of the influence of artefacts, as e.g. cupping and scatter.
Der Ersatz von Röntgenfilmen durch digitale Detektoren in der Zerstörungsfreien Prüfung im Anlagenbau wird seit 2013 durch neue ISO-Normen unterstützt. Nach der Erfolgsgeschichte der digitalen Photographie und der fast voll-ständigen Ablösung der Filmtechnik in der optischen Bilderfassung wird erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollzieht. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Computerra-diographie mit Speicherfolien eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluorosko-pe gibt. Mit Einführung der DIN EN ISO 17636-2 zur Schweißnahtprüfung wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte (Fehlernachweiß-empfindlichkeit) erreicht wird. Ein Überblick zeigt, welche Parameter für den praktischen Einsatz wichtig sind und wie sie ermittelt werden. Praktische Einsatzbeispiele im Anlagenbau werden diskutiert.
Die Technologie der hybriden Teilchen (oder Photonen) zählenden Bilddetektoren wurde seit mehr als 2 Jahrzehnten durch Institutionen wie das CERN (MediPix-/ TimePix-Chips) oder das Paul-Scherrer-Institut (Pilatus-/ Eiger-Chips) entwickelt. Die Ursprünge dieser Technologie kommen aus der Hochenergie-Physik mit ihren Beschleuniger-basierten Experimenten, bei denen ein zuverlässiger und rauschfreier Nachweis jedes ionisierten Teilchens gefordert wird. Eine Energieauflösung wird ebenfalls oft verlangr. Das ist auch in der klassischen Radiographie von Nutzen, so wurden diese Detektoren auch dafür optimiert. Neueste Photonen zählenden Detektoren besitzen folgende exzellenten Bildeigenschaften: rauschfreie Photonen-Detektion in einem hohen Dynamikbereich (SNR >2500 erreichbar), hohe räumliche Auflösung (bis zu 10 µm Pixelgröße), Energieschwellen bis zur vollen spektralen Auflösung und eine sehr hohe Geschwindigkeit (bis zu Tausenden Bildern pro Sekunde). Diese hybriden Detektoren können mit hochabsorbierenden Sensorschichten aus CdTe, CZT oder GaAs bestückt werden, um bildgebende Anwendungen mit Gamma- oder harten Röntgenstrahlen zu realisieren, in denen bisher Szintillator basierende Bilddetektoren dominierten (z.B. für NDT, SPECT, PET). Im Beitrag wird der erste wirklich große Photonen zählende Detektor mit CdTe und einer lückenlosen Detektionsfläche, die aus einer theoretisch unbegrenzten Anzahl von MediPix-/ TimePix-Modulen besteht, gezeigt. Die erste kommerzielle Version eines solchen Detektors hat eine Fläche von 7cm x7cm, 1,6 Megapixel und erfüllt die Anforderungen der Prüfklasse „B“ in der industriellen Radiographie. Die Energie auflösenden Fähigkeiten dieses Detektors erlauben eine „Farb-Radiographie“, in der verschiedene Materialien in verschiedene Farben dargestellt werden. Der 2. Teil dieses Beitrags stellt einen voll spektral auflösenden Gamma- und Röntgen-Bilddetektor mit dickem CdTe und 2,4 Megapixel vor, der auf TimePix3-Chips basiert und eine sehr hohe Ortsauflösung von ~10 µm erreicht. Die hohe Zeitauflösung von TimePix3 wird mit großem Nutzen für eine substantielle Verbesserung der erhaltenen Bilder und Spektren zur Unterdrückung interner Fluoreszenzstrahlung sowie Comptonstreuungsanteilen, die die Bildinformation verschmieren, verwendet.
In den letzten zwei Jahren wurden 11 neue Standards/Standardrevisionen zur RT veröffentlicht (ohne Strahlenschutz) und 5 werden dafür gestrichen. Es wird über die neuen Anforderungen ausgewählter Normen bzw. Normrevisionen informiert und insbesondere auch über die veränderten Parameter, die bei Prüfpraxis und bei der Klassifizierung zu berücksichtigen sind. Das wichtigste Projekt ist die Revision der DIN EN ISO 17636-1, -2, RT von Schweißverbindungen, in ISO TC 44 SC 5 WG 1. Die Standards zur Schweißnahtprüfung in der Kerntechnik, DIN 25435, wurden ins Englische übertragen und bei ISO TC 85 SC 6 bearbeitet. Hauptaktivität bei ASTM ist gegenwärtig die Überarbeitung der CT-Standards und die Berücksichtigung der Anforderungen an das dimensionelle Messen. Der Guide ASTM E 1441 zur Bestimmung von MTF, Kontrast-Detail-Funktion (CDF) und Kontrast-Diskrimination-Diagramm (CDD) wird revidiert. E 2445 zur CR Long Term Stability wird ebenfalls revidiert. Die Revision soll auch in die ISO 16371-1 eingehen. Dazu ist ein Round Robin-Test geplant. Auch die Standards zur Durchstrahlungsprüfung auf Korrosion und Ablagerungen in Rohren mit Röntgen- und Gammastrahlen (EN 16407-1, -2, 2014) wurden revidiert. Diese Revision wurde als DIN EN ISO 20769-1, -2 2018 veröffentlicht und EN 16407 wird zurückgezogen. Die Revision der Standards EN 12543 und EN 12679 zur Messung der Brennfleckgröße und der Strahlergröße ist mit Verzögerung in Überarbeitung, um die digitalen Detektoren und Messmöglichkeiten mit Bildverarbeitungsprogrammen zu berücksichtigen. Ein Entwurf zur Messung der Brennfleckgröße von nano-Fokusröhren wird derzeit vom Europäischen Metrologie-Programm EMPIR gefördert. Zur radiographischen Gussteilprüfung wurde der Standard EN 12681 revidiert und 2018 veröffentlicht. Er wurde um Zulässigkeitsgrenzen erweitert und die digitale Radiographie wurde in Teil 2 berücksichtigt.
X-ray back scatter imaging is rarely applied compared to classical X-ray projection imaging. 20 years ago the company Philips developed “COMSCAN”, a first application case in the aircraft industry, which allowed even a depth resolution using back scatter imaging. The company AS&E in Boston offers back scatter imaging solutions for the security market. Their principle is to scan the object with a highly collimated X-ray needle beam from one side only and detect the backscattered radiation by a large area detector side by side with the collimation wheel. A new prototype is investigated at BAM for application and optimization in non-destructive testing. As modern industrial application field in-situ testing in additive manufacturing is targeted. The accessibility of the printed part during the production process is very limited. This prevent the application of a two sided X-ray inspection or Computed Tomography, were an rotation of the object is required to acquire projections from 360 degrees. An important advantage for the X-ray back scatter technique are also the materials used in additive manufacturing (polymers, ceramics, light metals like Aluminum or Titanium). These materials with lower density and lower Z values give better scatter signals than metals with higher densities and Z values. The back scatter intensity decreases with increasing density and Z value of the material. But the requirements on spatial resolution and contrast sensitivity are more stringent for non-destructive testing of additive manufactured parts compared to the security area. In NDT sizes of indications smaller than 1 mm have to be detected clearly. The investigation of these limits on a stateof-the-art prototype for X-ray back scattering using rotating collimated X-ray needle beams is a part of the BAM project “ProMoAM”. The contribution shows first results of the optimization for NDT and the achieved application limits for several example cases.