In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study.
Isotope dilution mass spectrometry often is applied for the quantification of platinum group elements in environmental and geological samples. In most cases, however, certified spike solutions offering complete uncertainty statements and SI-traceability are missing. This report describes the production and certification of two isotope reference materials, ERM-AE140 and ERM-AE141, serving as calibrated spike solutions for IDMS based quantification of Pd and Pt, respectively. Both materials were produced by dissolving highly enriched isotopes 106Pd and 194Pt and determining the mass fraction of 106Pd and 194Pt in the final solution by reverse IDMS. Two independent back-spikes were produced for each material from high purity Pd and Pt. Characterization measurements were carried out by MC-ICPMS. For ERM-AE140 the certified mass fractions are w(106Pd) = 20.24(5) mg/kg and w(Pd) = 20.54(5) mg/kg. For ERM-AE141 the certified mass fractions are w(194Pt) = 18.18(11) mg/kg and w(Pt) = 19.90(12) mg/kg. These values are traceable to the International System of Units (SI) in the shortest possible way.
The use of magnetic materials as heterogeneous catalysts has attracted increasing attention in the last years since they proved to be promising candidates for water treatment. In the present study, two types of surface-modified magnetite (Fe3O4) nanoparticles, coated with non-hazardous naturally occurring agents—either tannic acid (TA) or dissolved natural organic matter—were evaluated as magnetic heterogeneous catalysts. Chemical synthesis (co-precipitation) was chosen to yield the nanocatalysts due to its well-established simplicity and efficiency. Subsequently, the properties of the final products were fully assessed by various characterization techniques. The catalytic activity in heterogeneous oxidation of aqueous solutions containing a model pollutant, Bisphenol A (BPA), was comparatively studied. The effect of operational parameters (catalyst loading, H2O2 dosage, and UV light irradiation) on the Degradation performance of the oxidation process was investigated. The optimum experimental parameters were found to be 1.0 g/L of catalysts and 10 mM H2O2, under UV irradiation. The highest mineralization rates were observed for Fe3O4-TA catalyst. More than 80 % of BPA was removed after 30 min of reaction time under the specified experimental conditions. The obtained results showed that the two catalysts studied here are suitable candidates for the removal of pollutants in wastewaters by means of heterogeneous reaction using a green sustainable treatment method.
The importance of microRNA (miRNA) dysregulation for the development and progression of diseases and the discovery of stable miRNAs in peripheral blood have made these short-sequence nucleic acids next-generation biomarkers. Here we present a fully homogeneous multiplexed miRNA FRET assay that combines careful biophotonic design with various RNA hybridization and ligation steps. The single-step, single-temperature, and amplification-free assay provides a unique combination of performance parameters compared to state-of-the-art miRNA detection technologies. Precise multiplexed quantification of miRNA-20a, -20b, and -21 at concentrations between 0.05 and 0.5 nm in a single 150 mL sample and detection limits between 0.2 and 0.9 nm in 7.5 mL serum samples demonstrate the feasibility of both highthroughput and point-of-care clinical diagnostics.
Laser-induced breakdown spectroscopy (LIBS) is a fast and versatile technique for (semi) quantitative element analysis of solids, liquids, gases, and particulate matter. The LIBS method is used for optical sensing in various branches of industrial production. In the contribution we review some of our recent results on LIBS analysis of slags from secondary metallurgy in industrial steel making. Major oxides in steel slags are measured at-line and after homogenization using a calibration-free (CF) method. Two approaches for CF analysis based on the Boltzmann plot method and on the calculation of synthetic spectra are compared for the analysis of quaternary oxides. We also present the research in cooperation with our industrial partners in the process-analytical chemistry network PAC.
For absorption processes with fluctuating feed gas compositions it is vital to continuously adjust
the operation point to achieve energy efficiency. In this contribution a Raman-based advanced
process control (APC) is introduced for the absorption of carbon dioxide (CO2) using an aqueous
solution of monoethanolamine (MEA). The APC is based on a Raman spectroscopic analysis of
the composition and CO2 load of the scrubbing liquid and a non-linear model predictive control
(NMPC) to adjust the scrubbing liquid cycle. In addition, an outer real-time optimization loop is
set in place to update the set points for the absorption process depending on the current feed gas composition minimizing the energy consumption of the process. Implementation and testing of the APC have been carried out in a mini-plant at TU Berlin. During a plant operation of more than 160 hours robustness and stability of the APC were shown.
Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectros-copy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical com-parison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory.
The Collaborative Research Center InPROMPT aims to establish a novel process concept for the hydroformylation of long-chained olefins, using a rhodium complex as catalyst in the presence of syngas. Recently, the hydroformylation in micro-emulsions, which allows for the efficient recycling of the expensive rhodium catalyst, was found to be feasible. However, the temperature and concentration sensitive multi-phase system demands a continuous observation of the reaction to achieve an operational and economically feasible plant operation. For that purpose, we tested the potential of both NMR and Raman spectroscopy for process control assistance. The lab-scale experiments were supported by sampling for off-line GC-analysis as reference analytics. The results of the NMR experiments will be part of another contribution.
Hydroformylation represents an important homogeneous catalyzed process, which is widely used within chemical industry. Usually applied with simple alkenes like Propene and Butene aldehydes obtained from alkenes >C6 are relevant intermediates in production of plasticizers, surfactants and polymers. Today the active catalyst species is often based on valuable Rhodium complexes in aqueous solution. This implies the problem of limited water solubility of the reactands, which is acceptable for short chain lengths, but states a problem in case of higher alkenes. Along with that efficient separation and recycling of the catalyst becomes more complicated. There are different approaches tackling this problem, e.g., by using of salt formation in the BASF process or downstream distillation within the Shell process
Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR.
Troubleshooting Samples Analytics:
Impurities in products: unexpected & unwanted occurrence, unknown identity, analytical method unclear, often various analytical methods, necessary, short response time important (< 1 d), benefits: allocation of its source within hours safes cost
• Investigations planned, coordinated and documented by TSA team
• Variety of analytical methods available
Polysaccharides modify the rheological properties of cement based systems. Depending upon their chemistry, molecular architecture, and adsorption tendency, they have different modes of action. Some polysaccharides like diutan gum have strong effect on the fluid phase; others like starch strongly interact with particles. This paper presents effects of diutan gum and starches in presence of polycarboxylates. Rheometric investigations with varied particle volume fractions and increasing coarse aggregate diameters were conducted. The results show that starches have stronger influence on the rheology at high particle volume fractions than diutan gum. At lower particle volume fractions this trend is inverted. Experiments with aggregates sizes up to 16 mm (0.63 in.) indicate that stabilizing agent influences on the effects of aggregates on yield stress were small; however up to 1.0 mm (0.04 in.), a significant effect on the plastic viscosity could be observed, which levelled off at larger diameters.
Ziel dieser Arbeit war die Entwicklung einer Methode zur Hochdurchsatzanalyse von partikelgebundenen Split-and-Mix-Peptidbibliotheken. Dabei wurde ein System entwickelt, das Partikelbibliotheken in kurzer Zeit auf ihre Bindung zu einem Zielmolekül hin untersucht und im nächsten Schritt eine direkte „Ein-Partikel“-Sequenzierung der Peptide von der festen Phase ermöglicht. Die Analyse der Bindung eines Zielmoleküls an ein selektiv bindendes Peptid wurde dabei in einem Modellsystem simuliert. Dazu wurde FITC-markiertes Neutravidin 3 mit festphasengebundenen biotinylierten und nicht-biotinylierten Peptiden inkubiert. Die Bindung von Neutravidin-FITC an die biotinylierten Peptide konnte erfolgreich mittels eines Fluoreszenzmikroskops nachgewiesen werden, wobei diese Methode für eine Hochdurchsatzanalyse ungeeignet war. So wurde die Analyse des Fluoreszenzassays auf einen Microarrayscanner übertragen (siehe Abbildung 33). Dies gelang erfolgreich wobei die hohe Eigenfluoreszenz des Tentagel-Harzes zu falsch positiven Ergebnissen führte. Mit einem Wechsel zum längerwelligen Fluoreszenzfarbstoff ATTO-633 konnten falsch positive Ergebnisse vermieden werden. Somit wurde die zeitintensive Fluoreszenzanalyse von einem Fluoreszenzmikroskop erfolgreich auf einen Microarrayscanner übertragen, welcher in kurzer Zeit (ca. 5 min pro Objektträger) eine Vielzahl an peptidbeladenen Partikeln gleichzeitig analysieren kann.
The catalytic efficiency of two magnetically responsive nanocatalysts was evaluated for the Degradation of Reactive Black 5 (RB5) and Reactive Yellow 84 (RY84) azo dyes using hydrogen peroxide as oxidant undervery mild conditions (atmospheric pressure, room temperature). In order to obtain the nanocatalysts, thesurface of magnetite (Fe3O4) nanoparticles, prepared by a co-precipitation method, was further modified with ferrous oxalate, a highly sensitive non-hazardous reducing agent. The sensitized nanomaterials were characterized by X-ray diffraction, scanning and transmission electron microscopy, energy-dispersive X-ray spectroscopy and vibrating sample magnetometry, and used in the catalytic wet hydrogen peroxideoxidation (CWHPO) of RB5 and RY84, in laboratory-scale experiments. The effect of important variables such as catalyst dosage, H2O2 concentration, and contact time was studied in the dye Degradation kinetics. The results showed that it was possible to remove up to 99.7% dye in the presence of 20 mM H2O2 after 240 min of oxidation for a catalyst concentration of 10 g L−1at 25◦C and initial pH value of 9.0.CWHPO of reactive dyes using sensitized magnetic nanocatalysts can be a suitable pre-treatment methodfor complete decolorization of effluents from textile dyeing and finishing processes, once the Optimum operating conditions are established.
N4-acetyl-SMX is the most important cross-reacting compound for the SMX-ELISA with concentrations of 1064 - 2488 ng/L in influent wastewater and 40 - 160 ng/L in effluent wastewater.
The ELISAgrams for estrone show less interfering signals than for SMX.
ELISAgrams of SMX and estrone display in effluent wastewater more interfering signals than in influent wastewater.
Zur Bestimmung von Arzneimittelrückständen in Oberflächengewässern wird häufig die LC-MS/MS als Methode der Wahl eingesetzt. Obwohl sich dieses Nachweisverfahren durch eine hohe Empfindlichkeit und Selektivität auszeichnet, gibt es vor allem bei geringen Substanzkonzentrationen häufig störende Einflüsse durch Matrixeffekte. Diese Matrixeffekte können unterschiedliche Ursachen haben.
Einige Matrixeffekte werden am Beispiel des Wirkstoffs Carbamazepin erläutert. Carbamazepin wird durch Kläranlagen nur partiell aus dem Abwasser entfernt und ist im Spurenbereich auch noch im Trinkwasser nachzuweisen. Wenn für die LC-MS/MS wasserbasierte Anteile in der mobilen Phase genutzt werden, befinden sich trotz Verwendung einer Labor-Reinstwasseranlage in der mobilen Phase noch kleinste Konzentrationen von Carbamazepin, welche einen Blindwert im unteren ppt-Bereich verursachen.
Weitere Matrixeffekte treten durch die unterschiedliche Qualität der Oberflächenwasserproben auf. Koelutionen von weiteren Inhaltstoffen zeitgleich mit dem Zielanalyten führen zu einer Diskriminierung des Meßsignals. Verbindungen, die den gleichen Massenübergang bei nahezu identischer Retentionszeit zeigen, erfordern eine reproduzierbare chromatographische Vortrennung oder die Wahl einer alternativen HPLC-Säule.
Fraunhofer Life Science Day
(2015)
Their high affinity, selectivity and specificity make monoclonal antibodies (mAbs) very important tools in research, diagnostics and therapy. The production of mAbs is routinely performed by hybridoma technique. Hybridomas are generated by fusing antibody-producing B cells with indefinitely proliferating myeloma cells. Both, cell fusion and the indispensable identification and isolation of the desired antibody-producing hybridoma clone is still far from being trivial.
We describe a novel method that should help to optimize the cell fusion, and the screening for antibody-secreting hapten-specific hybridoma cells by using fluorescence activated cell sorting and single-cell fusion. Hybridoma cells specific for a hapten were incubated with a hapten-peroxidase conjugate (hapten-HRP), which was subsequently incubated with a fluorophore-labeled polyclonal anti-peroxidase antibody (anti-HRP-Alexa Fluor® 488). To characterize the expression of membrane-bound immunoglobulin G (IgG) a fluorophore-labeled anti-mouse IgG antibody (anti-IgG-Alexa Fluor® 647) was used. Successful staining was verified by confocal laser scanning microscopy (CLSM). We show that it is possible to specifically label hapten-specific hybridoma cells. It should also be possible to use this labelling approach for the isolation of hapten-specific B cells from the spleen and use these cells for single-cell fusion. Parallelized cell fusion chips were developed to increase fusion efficiencies.
N-Hydroxysuccinimide (NHS) esters are the most important activated esters used in many different bioconjugation techniques, such as protein labelling by fluorescent dyes and enzymes, surface activation of chromatographic supports, microbeads, nanoparticles, and microarray slides, and also in the chemical synthesis of peptides. Usually, reactions with NHS esters are very reliable and of high yield, however, the compounds are sensitive to air moisture and water traces in solvents. Therefore, the quantification of NHS would be a very helpful approach to identify reagent impurities or degradation of stored NHS esters. No robust and sensitive method for the detection of NHS (or the more hydrophilic sulfo-NHS) has been reported yet. Here, a chromatographic method based on HILIC conditions and UV detection is presented, reaching a detection limit of about 1 mg L-1, which should be sensitive enough for most of the applications mentioned above. Exemplarily, the hydrolytic degradation of a biotin-NHS ester and a purity check of a fluorescent dye NHS ester are shown. An important advantage of this approach is its universality, since not the structurally variable ester compound is monitored, but the constant degradation product NHS or sulfo-NHS, which avoids the necessity to optimize the separation conditions and facilitates calibration considerably.