Analytische Chemie
Filtern
Dokumenttyp
- Posterpräsentation (51) (entfernen)
Sprache
- Englisch (51)
Referierte Publikation
- nein (51)
Schlagworte
- MIPs (10)
- Fluorescence (9)
- LIBS (7)
- Sialic acid (6)
- Laser induced plasma (5)
- Microfluidics (5)
- Plasma modeling (5)
- Core-shell particles (4)
- Molecularly Imprinted Polymers (4)
- Plasma diagnostics (4)
Organisationseinheit der BAM
- 1.9 Chemische und optische Sensorik (51) (entfernen)
Welcome to the poster Towards Determination of Surface Roughness from a SEM Image, a contribution from BAM in Berlin, Germany. This work is part of the MamaLoCA project, which aims to develop a biosensor for the detection of mycotoxins in cereals. Biosensors come in a great variety, one of which makes use of microscopic beads produced by homogenous coating of polystyrene microspheres. The beads are functionalized by decorating them with bioreceptors – in our case antibodies – which then specifically react with the analyte – in our case mycotoxins – and emit an electrical or optical signal. The functionalization of the beads depends on the surface roughness because this determines the amount and orientation of binders. In other words, the surface roughness affects the accessibility to the binding sites and influences device sensitivity, hence its quantitative determination is an important step in evaluating the quality of the biosensor in general.
The presented solution to the problem of the estimation of surface roughness relies in the repetitive characteristics on the surface of the beads. A SEM image of the bead shows a raspberry like microparticle with a variation of grayscale values, which arise from the secondary electron yield. The principle of the measurement measures the variation of grayscale values along a circumference of a circle centred in the centre of the particle and with an arbitrary radius. The grayscale value variation along the given circumference gives the so-called z-modulation or the lateral profile. By performing Fast Fourier Transform on this profile we obtain the power spectrum as a function of the spatial frequencies through which the grayscales vary. The maximal value for spatial frequency then reveals the most common feature along one given circumference. Surface roughness then is the feature frequency in the spatial domain. This calculation is repeated for several concentric circles with different radii over the particle.
The results for the same particle but recorded at two different accelerating voltages show that the applied method has a potential to reveal the roughness. Interpretation of results from an SE InLens SEM image obtained using 3 kV shows that surface roughness is about 21 nm, which is in a good agreement with an alternative method given in a different presentation. The results from the 10 kV are underestimated due to the loss of surface sensitivity on the SE InLens detection at high voltages.
In conclusion, this method shows promise in determining quantitatively the surface roughness from a single SEM image and its validation is being sought using 3D SEM images and AFM methods.
Additive Manufacturing (AM) becomes widespread in many technological fields including the precise machining of steel. To assure quality of final products, thorough monitoring of online process is required. We test several monitoring techniques during the AM printing to quickly detect and possibly correct flaws while building a workpiece. Here we show how optical emission spectroscopy can be used to recognize defects that are artificially introduced on a steel printing substrate.
The globe's seas were used as dumping ground after the world wars and those millions of ammunition, most of all containing 2,4,6-trinitrotoluene (TNT), represent a pressing danger for fishermen, dredging operations, submarine cable installations and tourism. We developed an extremely selective indication method for TNT based on a specific reaction that produces a highly fluorescent compound. The indication system was integrated into a microfluidic PDMS chip for the solid-liquid extraction of TNT from water samples, offering environmental monitoring possibilities. Combining the advantages of a light-up indicator, microfluidics and a smartphone as detector, the embedded sensor allows for the remote and rapid detection of TNT down to ng in surface and sea waters.
Sensors are the scientific and technological extension of human senses and enormously expand human capabilities. Despite the fact that scientific and technological advances are usually seen in a positive light, the name of this conference, Sensors for Good, put me in a bit of a trouble, because in general science does not operate in ethical categories, but instead it just tells how far from the truth one is. In this respect, sensors help us in recognizing states and events beyond our immediate reach. Fortunately, sensors are used for many applications, such as environmental monitoring, food control, and alike, which unequivocally benefit society.
I will focus on a particular type of sensors, those that rely on microfluidics for operation and which are typically realized in lab-on-a-chip (LOC) devices. In this domain, where at least one of the dimensions through which a fluid flows is submillimetric, our natural senses fail, because the phenomena are too small to be detected either by eye, smell, touch, and even the common sense explanation that we learn for many years in school is not applicable, because the phenomena are dominated by different parameters. To give one simple example, in general the direction of flow in microfluidic channels does not depend on the up-down direction of the channel, because gravitational force or the weight of the fluid is negligible compared to the viscous forces present on the chip.
This presentation consists of three parts: initially, two sensors produced in our lab are presented, followed by a simulation oriented discussion on microfluidics and biosensors, and finally a project in progress that we are involved in is presented, concluding with a list of open issues raised during the presentation.
Type-I pyrethroids are frequently used for disinfection purposes on airplanes from and to tropical areas as a preventive health measure to control or kill the insect vectors of human diseases including dengue, yellow fever and malaria. The aim of the presented work was the development of such a simple, rapid and effective method for pyrethroid analysis
The urgent necessity to carry out reliable and relevant analytical measurements directly at a point-of-need is one of the current drivers for the development of miniaturised analytical systems, quick tests and wearables. Despite their simplicity, this type of tests must guarantee analytical relevance and reliability like laboratory-based analysis, e.g., in terms of sensitivity, selectivity, immunity against false positives and false negatives as well as robustness and repeatability. Keeping in mind the high sensitivity offered by gated indicator-releasing micro- and nanoparticles due to their inherent features of signal amplification, we performed several optimisations to develop a potential biosensor platform for use in rapid tests. Conceptually, these gated materials are closely related to drug delivery systems, consisting of high porous materials usually closed with macromolecular “caps” and loaded with indicator molecules that are released in presence of a target analyte. However, the key difference between the two types of functional materials is that many drug delivery systems should deliver their cargo over a longer period, often many hours, whereas the gated materials prepared for sensing should show fast release kinetics, on the order of <5 min.
With the aim to optimise and adapt gated materials for sensing purposes, we prepared in this work several antibody-gated materials for small-molecule sensing. The materials consisted of porous silica particles containing indicator molecules in the pores and certain hapten molecules grafted to the particle surface close to the pore openings. The pores were then capped with antibodies binding to these haptens, thus inhibiting the escape of the indicators from inside of the pores. In presence of the corresponding analyte, the antibody is displaced from the surface of the material, allowing the escape of the indicators. This allows the detection of the analyte indirectly through an inherent signal amplification. In this work, the insecticide permethrin, a type-I pyrethroid, was selected as target model, because type-I pyrethroids play an important role in airplane disinfection. A first in-depth study of the various chemical tuning options of such antibody gated systems was performed. Different mesoporous silica supports, different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material’s pore openings, the better the closing/opening mechanism can be controlled. Because such materials can be used in various different formats from suspension assays[1] via microfluidic chips[2] to test strip-based lateral flow assays,[3] such materials present a powerful analytical particle platform for the sensitive analytics and diagnostics outside of a laboratory, realising sensitivities down to the µg kg–1 range in less analysis times of less than 5 min as we have recently demonstrated.[4]
Combined Raman and LIBS using Spatial Heterodyne Spectrometer with High Repetition Rate Laser
(2020)
Spatial heterodyne spectroscopy is used for Raman and laser-induced breakdown spectroscopy of six rocks with various mineral content, using high repetition rate diode-pumped solid state lasers. While LIBS data are obtained for all samples, Raman signal was determined only for half of those. This work shows that it is possible to combine LIBS and Raman spectrometry into a single instrument consisting of a DPSS laser for excitation and SHS for spectral recording. For better results and gain from complementary spectrochemical information that the system provides, it is necessary to optimize light collection.
The spatial heterodyne spectrometer (SHS) concept, which is based on an interferometricoptical setup, boasts both the Fellgett and Jacquinot advantages. Theoretically it can provideboosted sensitivity and spectral resolution with respect to dispersion spectrometers in acompact, reasonably cheap arrangement without any moving components – this set ofcharacteristics can be attractive to a number of industrial, space and other field applications. The potential of SHS has already been demonstrated in IR and Raman spectroscopies(e.g.), and more recently also in LIBS. The scientific goal of our present project is toapply the SHS concept to the development of an optimized, but practical dual-grating,tunable SH-LIBS setup, which would possess appealing spectroscopic characteristics.During this development, we extensively rely on the computer-based simulation of theoptical setup, which is an efficient approach that we found to have been missing from earlierSHS efforts published. It can provide application-specific optimization of the SHS systemand predict the performance of the final system. In particular, we use optical simulation tostudy the effect of various important parameters on the relevant spectroscopic figures ofmerits of the system. We used the non-sequential ray-tracing mode of the Zemax/OpticStudio software for optical modelling of the SH-LIBS setup (Optical distortions were studiedin sequential mode). Characteristics of the setup and interferograms were calculated with atleast one million rays. All calculations were carried out for the visible spectral range(400-700 nm), using stepwise extension of monochromatic simulations with 5 nm steps.Wherever applicable, characteristic discrete visible wavelengths from the emissionspectrum of Hg discharge lamps (404.7 nm, 435.8 nm, 546.1 nm, 579.0 nm) were used for thecalculation of spectroscopy figures of merit and for the validation of simulation.
Asymmetrical laser-induced plasmas were investigated by a tomography approach based onthe inverse Radon transform. Two distinct sources of asymmetricity were investigated:double-pulsed laser-induced plasmas in the orthogonal configuration and single-pulsedlaser-induced plasmas under an inclined incidence angle. Both cases were observed atvarious delay times. The optical thinness of the laser-induced plasmas was achieved byappropriately adjusting the pulse energies. High temporal resolution was achieved by agated intensified charge-coupled-device camera. The asymmetrical laser-induced plasmaswere investigated in terms of their total emissivity, spectrally resolved emissivity, andtemperature. The latter was obtained by the Saha–Boltzmann plot method. The imagesrequired for the inverse Radon transform technique were obtained with a high angularaccuracy and reproducibility provided by mounting the spectrometer on a high-precisionnano-positioning rotary stage. The plasmas were induced in the center of rotation of thestage. This arrangement enabled the reconstruction of emissivity which was integrated overthe full spectral range (200–800 nm) or over a desired spectral range selected by a bandpassfilter (~10 nm). It also allowed for the reconstruction of spectrally-resolved emissivity ineach cross-sectional plasma slice by scanning the plasma across a spectrometer slit. The 3Dmaps of the temperature and electron density were thus obtained for different types ofasymmetric plasmas. The work will provide a more detailed description of the twoasymmetrical laser-induced plasmas. This might help with the development of LIBSinstrumentation using the orthogonal double-pulse geometry, or remote LIBS applicationswhich inherently rely on inclined-angle ablation.