Analytische Chemie
Filtern
Erscheinungsjahr
- 2017 (169) (entfernen)
Dokumenttyp
- Posterpräsentation (169) (entfernen)
Sprache
- Englisch (169) (entfernen)
Schlagworte
- Nanoparticles (14)
- Online NMR spectroscopy (10)
- XPS (9)
- CONSENS (8)
- In situ (7)
- Nanoparticle (7)
- Fluorescence (6)
- Online NMR Spectroscopy (6)
- Process analytical technology (6)
- SEM/EDX (6)
We developed a rapid and robust HPLC-MS/MS (QqQ) method for the quantification of hepcidin-25, a promising new biomarker in iron metabolism, in human samples. The novelty of the method is the use of special HPLC vials to avoid adsorptive losses due to the basic character of the peptide that causes interaction with the silanol groups of the vial’s glass surface. Up to 90% decrease in the MS/MS signal was observed, when commercial HPLC vials were used, while vials treated with 3-(2-aminoethylamino)propylmethyldimethoxysilane or 1H,1H,2H,2H-perfluorooctyltriethoxysilane, leading to no losses in the range of physiological hepcidin-25 mean serum levels (10-20 µg/L).
Due to the demand of monitoring the water quality regarding emerging pollutants, such as drug residues, selective, high-throughput and multi-target analytical methods must be established. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affine and specific recognition of antibodies to target molecules. Batch-wise processing in microtiter plates allow the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex micro-bead based flow cytometric assay, which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core-silica-shell particles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica-shell creates a solid-support for the immunoassay: The target analytes, three drugs, carbamazepine, diclofenac and caffeine and the f ecal marker isolithocholic acid are covalently coupled to amino-groups on the surface via NHS-chemistry. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure. Finally, we could use SAFIA to assess the influent of treated and untreated waste water on the Douro river estuary in Portugal. The results of the analysis are comparable to ELISA. However, measurements could be carried out in 25% the time of analysis.
Mechanaochemistry is an effective method to yield pure compounds within a short reaction time. Mechanochemical C-C bond forming reactions gained increasing interest in the past decade. Among those the Knoevenagel condensation is an important reaction for synthezing a,b-unsaturated compounds. The information on the underlying mechanisms of mechanochemical reactions are scarce. In situ investigations using Raman spectroscopy and synchroton XRD either alone or in combination address this challenge. We present the in situ results of a Knoevenagel condensation with p-nitrobenzaldehyde and malononitrile under neat grinding conditions.
Mechanaochemistry is an effective method to yield pure compounds within a short reaction time. Mechanochemical C-C bond forming reactions gained increasing interest in the past decade. Among those the Knoevenagel condensation is an important reaction for synthezing a,b-unsaturated compounds. The information on the underlying mechanisms of
mechanochemical reactions are scarce. In situ investigations using Raman spectroscopy and synchroton XRD either alone or in combination address this challenge. We present the in situ results of a Knoevenagel condensation with p-nitrobenzaldehyde and malononitrile under neat grinding conditions.
Mechanaochemistry is an effective method to yield pure compounds within a short reaction time. Mechanochemical C-C bond forming reactions gained increasing interest in the past decade. Among those the Knoevenagel condensation is an important reaction for synthezing a,b-unsaturated compounds. The information on the underlying mechanisms of mechanochemical reactions are scarce. In situ investigations using Raman spectroscopy and synchroton XRD either alone or in combination address this challenge. We present the in situ results of a Knoevenagel condensation with p-nitrobenzaldehyde and malononitrile under neat grinding conditions.
The EC recommendation for the definition of nanomaterial [2011/696/EU] requires the quantitative size determination of constituent particles in samples down to 1 nm. Accordingly, a material is a nanomaterial if 50 % or more of the particles are in the size range 1-100 nm. The fact that engineered nanomaterials already exist in many industrial and consumer products challenges the development of measurement methods to reliably identify, characterize and quantify their occurrence as substance and in various matrices.
The EU FP7 NanoDefine project [www.nanodefine.eu] has addressed this challenge by developing a robust, readily implementable and cost-effective measurement strategy to obtain quantitative particle size distributions and to distinguish between nano and non-nano materials according to the EU definition. Based on a comprehensive evaluation of existing methodologies and intra- and inter-lab comparisons, validated measurement methods and instrument calibration procedures have been established to reliably measure the size of particles within 1-100 nm, and beyond, including different shapes, coatings and chemical compositions in industrial materials and consumer products. Case studies prove their applicability for various sectors, including food, pigments and cosmetics.
Main outcome is the establishment of an integrated tiered approach including rapid screening (tier 1) and confirmatory methods (tier 2), and a user manual to guide end-users, such as manufacturers, in selecting appropriate methods. Another main product is the “NanoDefiner” e-Tool allowing the standardised / semi-automated selection of appropriate methods for material classification according to the EU definition. Results also contribute to standardization efforts, such as CEN TC 352 or ISO TC 229.
Accurate measurements of stable isotope abundance ratio variations are often reported using artifact based delta-scales, which rely on suitable isotopic reference materials (iRM) for their realization. For example, variations in the 26Mg/24Mg isotope abundance ratio in natural systems are typically reported as delta26Mg values that represents the relative difference between the 26Mg/24Mg ratio measured in a sample relative to its measurement preferably in an iRM. In the past, such delta26Mg measurements were referenced to NIST SRM 980, the initial zero of the delta26Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. It was then replaced by a Mg solution (DSM3), the new zero of the delta26Mg scale. A potential replacement iRM for DSM3 has been developed, ERM-AE143. This iRM has also been measured for its absolute isotope amount ratios1,2 making it traceable to the SI.
The results of an delta26Mg intercomparison experiment include the Mg iRMs SRM 980, IRMM-009, ERM-AE143, AE144, AE145 standards DSM3 and Cambridge-1. The intercomparison involved 5 expert laboratories, consisting of 3 national metrological institutes (BAM, NIST, PTB) and 2 scientific research laboratories (GFZ Potsdam, UBremen).
The iRMs were measured relative to AE143 and cover a range of ≈5 ‰ in delta26Mg. IRMM-009 has the lowest delta26Mg value while DSM3 has the highest, spanning a range in values that covers natural Mg isotope variations. The 2SD reproducibilities of the individual values from the different laboratories range from 0.02 to 0.26 ‰. The mean delta26Mg values, calculated from the laboratory means however show 2SD reproducibilities varing between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for delta26Mg determinations.
1 JAAS, 2015, 31,179; 2JAAS, 2016, 31, 1440
Scanning Electron Microscopy (SEM) or Transmission Electron Microscopy (TEM) ? This is a question, nowadays discussed in EM labs of research and industry involved in the characterization and metrology of nanoparticles. The Scanning principle is adapted to TEM, the Transmission mode is adapted to Ultra High Resolution SEM. Can modern SEM replace TEM, reach atomic resolution even without Cs corrector or nm lateral resolution for energydispersive X-ray spectroscopy (EDX)?
Due to the development of a New Cold Field Emission (NCFE) electron source Hitachi SEMs SU9000 and SU8200 can deliver routinely sub-nm image resolution and EDX mappings at very high count rates and a lateral EDX resolution of a few nm. A TiO2 sample provided by BAM was analysed at 30kV using low kV STEM – simultaneously with the Through-the-lens (TTL) SE detector, the Bright Field transmitted and Dark Field transmitted signals. By this method a pixel precise information of the particles surface using SE, its chemical nature using DF-STEM and its crystalline structure using Bright Field signal is given in one 40sec scan. The advantage of this observation mode compared to Ultra Low Voltage imaging is outlined.
The development of low carbon cements has gained great importance over the last decades. In the effort to limit the carbon content related to its production, cement is often replaced with supplementary cementitious materials (SCMs). Commonly used SCMs such as fly ash and slag have undergone extensive research, but are currently limited in supply and availability. Among the researched SCMs, calcined clays have proven to be a suitable alternative pozzolan due to their worldwide availability and extremely low calcination temperatures when compared to clinker. This poster presents the results from an ongoing project, aimed at obtaining pozzolans, available in sufficient quantities for Portland-pozzolana cement production in Germany. The poster shows the analyses of seven brick clays from various deposits in central Germany. The chemical and mineral composition of the brick clays was evaluated through inductively coupled plasma – optical emission spectroscopy (ICP-OES), X-ray diffraction (XRD), and thermogravimetric analysis (TG/DTG). The particle size distribution (PSD) was also evaluated by laser granulometry. The results show that the brick clays contain a substantial amount of kaolinite, illite and smectite minerals, the relative proportions differing significantly between deposits. The suitable calcination temperature range of the clays is also evaluated through TG/DTG analysis to obtain the optimum degree of dehydroxylation from which the bricks clays can be suitable for use as a pozzolan.
A multilayer consisting of two different rotaxanes was investigated with different analytical methods. The rotaxanes can be switched with two different stimuli - chemical and photochemical. XPS indicates that our layer-by-layer approach worked and a layer growth with every deposition step is present. NEXAFS showed that both stimuli cause an increase of the multilayer's preferential orientation.