Schlagworte
- Mobile Robot Olfaction (26)
- Nano aerial robot (18)
- TDLAS (13)
- Swarm (12)
- Environmental monitoring (11)
- Sensor network (11)
- Aerial robot (10)
- Gas tomography (10)
- Low-cost (10)
- Tomographic reconstruction of gas plumes (10)
Organisationseinheit der BAM
- 8.1 Sensorik, mess- und prüftechnische Verfahren (230) (entfernen)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (80)
Wyciek metanu (CH4) z infrastruktury takiej jak rurociągi czy zbiorniki magazynowe ma kluczowe znaczenie dla środowiska oraz stwarza zagrożenie dla bezpieczeństwa ludzi i mienia. Obecnie, po okresie bezawaryjnej eksploatacji, można zaobserwować wzrost liczby incydentów spowodowanych nieszczelnościami rurociągów przesyłowych.
W Polsce szczególnie problematyczne okazują się gazociągi, które powstały dekady temu. W tamtym czasie normy techniczne i przepisy budowlane były łagodniejsze niż obecnie obowiązujące. Integralność tych gazociągów jest trudna do skontrolowania, gdyż na etapie budowy nie zostały one przystosowane do badania tłokami pomiarowymi. Aby sprostać temu wyzwaniu, UDT poszukuje metod umożliwiających szybkie i niezawodne wykrywanie oraz lokalizowanie nieszczelności gazociągów na duże odległości.
In this study, nanoscopic particles of magnesium Fluoride (MgF2) and calcium fluoride (CaF2) also known as nano metal fluorides (NMFs), were evaluated for their potential to improve wood durability. Even though these fluorides are sparingly soluble, their synthesis in the form of nano-sized particles turns them into promising candidates for wood preservation. Their distinct property of low-water solubility is proposed to maintain long-lasting protection of treated wood by reducing the leaching of fluoride. Analytical methods were used to characterize the synthesized NMFs and their distribution in treated wood specimens. Transmission electron microscopy images showed that these fluoride particles are smaller than 10 nm. In nano metal fluoride (NMF) treated specimens, aggregates of these particles are uniformly distributed in the wood matrix as confirmed with scanning electron microscopy images and their corresponding energy-dispersive X-ray spectroscopy maps. The fluoride aggregates form a protective layer around the tracheid walls and block the bordered pits, thus reducing the possible flow path for water absorption into wood. This is reflected in the reduced swelling and increased hydrophobicity of wood treated with NMFs. The biocidal efficacy of NMFs was tested against brown-rot fungi (Coniophora puteanaand Rhodonia placenta), white-rot fungus (Trametes versicolor), and termites (Coptotermes formosanus). The fungal and termite tests were performed in accordance with the EN 113 (1996) and EN 117 (2012) standards, respectively. Prior to fungal tests, the NMF treated wood specimens were leached according to the EN 84 (1997)standard. Compared to untreated specimens, the NMF treated wood specimens have a higher resistance to decay caused by brown-rot fungi, white-rot fungus, and termites. Although all NMF treatments in wood reduce the mass loss caused by fungal decay, only the combined treatment of MgF2 and CaF2 has efficacy against both brown-rot fungi and white-rot fungus. Similarly, wood treated with the combined NMF formulation is the least susceptible to attack by C. formosanus.It is proposed that combining MgF2 and CaF2changes their overall solubility to promote the release of fluoride ions at the optimal concentration needed for biocidal efficacy against fungi and termites. In this thesis, it was proven that even after leaching, sufficient fluoride was present to protect NMF treated wood from fungal decay. This shows that NMFs are robust enough for above ground contact outdoor applications of wood, where permanent wetness cannot be avoided according to Use Class 3.2, as per the EN 335 (2013) standard. Also, they pose a low risk to human health and the environment because they are sparingly soluble. Since NMFs significantly reduce the decay of wood, the CO2 fixed in it will be retained for longer than in unpreserved wood. Overall, the novel results of this study show the potential of NMFs to increase the service life of building materials made from non-durable wood.
This paper describes a wireless mobile prototype able to perform optical measurements by means of a miniaturized spectrometer for low light analysis, e.g. fluorescent sensors.
Evaluations, calculations, calibration management and result display are performed by a computer or a standard tablet. The device was designed primarily to detect traces of oil in drinking or ground water and for the analyses of crude oils. However, it can also address a wide range of fluorescent sensors. The fast and user-friendly inspection of water quality or oil properties, as well as the adaptability and mobility, make the device attractive for a variety of users. Further application areas could be easily implemented by adapting the optics and the software (database, data processing and calibration plots, etc.).
This paper describes a wireless mobile prototype able to perform optical measurements by means of a miniatur-ized spectrometer for low light analysis, e.g. fluorescent sensors. Evaluations, calculations, calibration management and result display are performed by a computer or a standard tablet. The device was designed primarily to detect traces of oil in drinking or ground water and for the analyses of crude oils. However, it can also address a wide range of fluorescent sensors. The fast and user-friendly inspection of water quality or oil properties, as well as the adaptability and mobility, make the device attractive for a variety of users. Further application areas could be easily imple-mented by adapting the optics and the software (database, data processing and calibration plots, etc.)
Small unmanned aircraft are used increasingly as flying sensor platforms to perform tasks such as gas distribution mapping or environmental monitoring. Sometimes, these applications require knowledge of the ambient wind field.
In general, it would be interesting to avoid any additional hardware, both on ground and on the aircraft. Here, we present an approach to estimate the wind vector just by exploiting the state variables of the aircraft.
Small unmanned aircraft (UA) are used increasingly as flying sensor platforms. Amongst other things they are used for environmental monitoring, for example gas distribution mapping. Sometimes, these applications require knowledge of the ambient wind field, which can be measured by additional devices like anemometers. In general, it would be interesting to avoid such additional apparatuses. One way to achieve this is to estimate the wind vector, that is both the wind direction and speed, from the state variables of the UA.
An equation for wind vector estimation using a multirotor aircraft as a flying anemometer is shown. To compute the wind vector an estimate of the thrust of the aircraft is required, which is related to the rotational speed of the rotors. Hence, a sensing system for the rotational speed using phototransistors is presented.
Um die Versagensabläufe über die verschiedenen Skalen im Holzwerkstoff verfolgen zu können, werden Zugversuche an Lagenhölzern mittels Schallemissionsmessung überwacht. Synchron erfolgen In-situ-Messungen mit Digitaler Bildkorrelation bzw. Synchrotron-Mikro-Computertomographie. Die Kombination aller Ergebnisse wie auch die Anwendung der frequenzbasierten Mustererkennung und die Simulation ausgewählter Versuche zielen auf die Identifizierung zugrunde liegender Mechanismen hin. Abschließend werden Ansätze für ein Monitoring von Holzstrukturen diskutiert.
The presence of wastewater and air pollution has become an important risk factor for citizens, not only in terms of problems related to health risks, but also because of its negative impact on the country's image. For this reason, malodorous emission monitoring and control techniques are in high demand in urban areas and industries. The aim of this work is first to build an electronic nose (e-nose) and a Voltammetric Electronic tongue (VE-tongue) in order to study their ability to discriminate between polluted and clean environmental samples. Secondly, Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS), and Solid Phase Micro Extraction-Gas Chromatography–Mass Spectrometry (SPME-GC-MS) are utilized to explain this discrimination by identifying specific compounds from these samples. Indeed, the e-nose, consisted of metal oxide semiconductor gas sensors, is used for the assessment of the studied odorous air and headspace samples from water and wastewater sites. Moreover, the VE-tongue, based on metal electrodes, is utilized to determine the patterns of the sensor array responses, which serve as fingerprints profiles of the analyzed liquid samples. Chemometric tools, such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA), and Support Vector Machines (SVMs) are operated for the processing of data from the e-nose and the VE-tongue. By using the both systems, the analyses of headspace and liquid samples from the seven sites allow better discrimination. To explain the cause of the obtained discrimination, TD-GC-MS and SPME-GC-MS analyses are well performed to identify compounds related sites. According to these outcomes, the proposed e-nose and VE-tongue are proved to be rapid and valuable tools for analysis of environmental polluted matrices.
Technische Richtlinien enthalten Empfehlungen sowie Anforderungen zum Stand der Technik zur Aufstellung von Bewertungskriterien und Behandlung wissenschaftlich-technischer Fragen. Sie fördern den Erfahrungsaustausch und Technologietransfer zwischen Entwicklern und Anwendern.
In unserem Beitrag stellen wir die Richtlinie VDI/VDE 3518 vor. Diese Richtlinienreihe definiert Begriffe, beschreibt den Aufbau und klassifiziert Multigassensoren (Blatt 1), befasst sich mit den Anforderungen für das Unterscheiden, Erkennen und mengenmäßige Bestimmen von Gemischen gasförmiger Stoffe und die Prüfung von Multigassensoren (Blatt 2) und gibt Anleitung für geruchsbezogene Messungen mit „Elektronischen Nasen“ (Blatt 3). Multigassensoren können als elektronische Nasen in Anlehnung an den biologischen Geruchssinn zur Wahrnehmung und Charakterisierung von Gerüchen eingesetzt werden. Die Spezifik von Multigassensoren besteht darin, dass durch die Wahl und Betriebsweise der Sensoren eine Vielzahl von geeigneten Messsignalen erzeugt werden, aus denen mit mathematischen Verfahren die für die Anwendung gewünschten Informationen extrahiert werden. Dazu ist ein Training der Messeinrichtung mit Proben bekannter Eigenschaften notwendig.
Diese Richtlinie soll Herstellern, Anbietern und Nutzern als ein Leitfaden Informationen und Erläuterungen für die korrekte und sichere Arbeit mit Multigassensoren liefern. Sie soll Prüflaboratorien und Anwendern helfen, bei der Beurteilung von Qualitätsmerkmalen einheitlich vorzugehen und dafür gemeinsame Randbedingungen anzugeben
Der Beitrag präsentiert die erarbeiteten technischen Richtlinien zur Anwendung und Prüfung von Multigassensoren innerhalb der Richtlinienreihe VDI/VDE 3518 sowie in diesem Zusammenhang die Möglichkeiten der Sensorprüfung im akkreditierten Prüflabor des Fachbereichs 8.1 der BAM. Im Speziellen wird das in Kürze veröffentlichte Blatt 3 der Richtlinienreihe vorgestellt, das Bezug auf Multigassensoren für geruchsbezogene Messungen mit elektronischen Nasen nimmt.
Der Beitrag präsentiert die erarbeiteten technischen Richtlinien zur Anwendung und Prüfung von Multigassensoren innerhalb der Richtlinienreihe VDI/VDE 3518 sowie in diesem Zusammenhang die Möglichkeiten der Sensorprüfung im akkreditierten Prüflabor des Fachbereichs 8.1 der BAM. Im Speziellen wird das in Kürze veröffentlichte Blatt 3 der Richtlinienreihe vorgestellt, das Bezug auf Multigassensoren für geruchsbezogene Messungen mit elektronischen Nasen nimmt.
Der Beitrag präsentiert die erarbeiteten technischen Richtlinien zur Anwendung und Prüfung von Multigassensoren innerhalb der Richtlinienreihe VDI/VDE 3518 sowie in diesem Zusammenhang die Möglichkeiten der Sensorprüfung im akkreditierten Prüflabor des Fachbereichs 8.1 der BAM. Im Speziellen wird das in Kürze veröffentlichte Blatt 3 der Richtlinienreihe vorgestellt, das Bezug auf Multigassensoren für geruchsbezogene Messungen mit elektronischen Nasen nimmt.
Wireless sensor networks provide occupational health experts with valuable information about the distribution of air pollutants in an environment. However, especially low-cost sensors may produce faulty measurements or fail completely. Consequently, not only spatial coverage but also redundancy should be a design criterion for the deployment of a sensor network. For a sensor network deployed in a steel factory, we analyze the correlations between sensors and build machine learning forecasting models, to investigate how well the sensor network can compensate for the outage of sensors. While our results show promising prediction quality of the models, they also indicate the presence of spatially very limited events. We, therefore, conclude that initial measurements with, e.g., mobile units, could help to identify important locations to design redundant sensor networks.
Sensors can fail. Redundancy should therefore be a design driver of wireless sensor networks. For a sensor network deployed in a steel factory, we analyze the correlations between sensors and build machine learning forecasting models, to investigate how well the network can compensate for the outage of sensors.
Die Optimierung und Validierung des digitalen Wasserstofftankstellenmanagements mit Sensortechnologien ist das übergeordnete Ziel des Teilprojekts Digitale Qualitätsinfrastruktur mit Sensortechnologien (QIST) am Use Case H2, im Rahmen der digitalen Qualitätsinfrastruktur (QI digital[1]). Hierfür sollen u.a. Sensornetzwerke mit digital-gestützten Auswertungsstrategien intelligent gestaltet werden (Stichwort KI bzw. digitaler Zwilling). Verschiedene, sich ergänzende Sensoren, Systemkomponenten und KI-Methoden stehen als Bausteine intelligenter Sensorsysteme zur Verfügung, mit dem Zweck, die physikalischen und chemischen Parameter an und in Anlagen umfassend und effizient zu überwachen sowie Fehlfunktionen zuverlässig zu detektieren und zu interpretieren, Abbildung 1.
Konkrete Arbeitsschritte sind, nach dem Aufbau der Versuchsplattform „Wasserstofftankstelle“, die Instrumentierung von Sensorik und deren digitale Integration in das Tankstellenmanagementsystem sowie die Validierung im Realbetrieb. Die somit erzielten Messergebisse sowie die Messunsicherheiten, Historien und Verfahren werden in digitaler Form aufbereitet, gespeichert und fortlaufend in die KI-basierte Datenauswertung einbezogen, inkl. der Anbindung an die metrologische Rückführungskette.
Ziele sind:
• Einführung eines neuen messtechnischen Ansatzes und eines digitalen Zwillings für den Anwendungsfall "Wasserstofftankstelle" auf Basis der H2-Sensorik sowie der Zustandsgrößen Druck und Temperatur
• Qualitätssicherung durch Applikationen zuverlässiger Gassensorik, Manometer und Thermometer sowie KI-Methoden zur Prozesskontrolle und Detektion von Fehlfunktionen
• Nutzung von digitalen Kalibrierscheinen (DCCs) insbesondere für die Messgröße Temperatur zur Realisierung der metrologischen Rückführung in einer digitalen Qualitätsinfrastruktur
Feuchte, sei es Material- oder Gasfeuchte, ist eine wichtige Messgröße bei der Qualitätsbeurteilung von Kunststoffen, landwirtschaftlichen Erzeugnissen, Energieträgern, Arzneimitteln, industriell und medizinisch verwendeten Gasen. Deswegen gibt es ein Interesse Feuchtemesserfahren hinsichtlich Präzision, Wiederholbarkeit, Rückführbarkeit und Stabilität kontinuierlich zu verbessern. Ein bewährtes Messprinzip für diese Aufgabe wurde bereits 1959 von Keidel entwickelt und basiert auf der Absorption und Elektrolyse von Wasserdampf. Der einfache Aufbau dieses Prinzips besteht aus einem Sensorelement, einer Gleichspannungsquelle, einem Digitalmultimeter und einen geregelten Gasstrom über den Sensor. Nach dem Faraday’schen Gesetz der Elektrolyse korreliert bei dem Messprinzip die Ladungsmenge mit der elektrolysierten Wassermasse. Jedoch bedarf es in der heutigen Zeit einer Validierung der Sensoren, weil durch gezielte Miniaturisierung weniger aktive Fläche vorhanden ist und somit das Faraday’sche Gesetz nicht vollständig anwendbar ist. In dieser Arbeit wurden coulometrische Sensoren mit einer planaren Elektrodenstruktur hinsichtlich der Einflüsse von unterschiedlichen Gasen, der Gastemperatur und dem -druck untersucht. Zusätzlich wurde eine neuartige Sensorbeschichtung basierend auf einer ionischen Flüssigkeit getestet. Des Weiteren wurde ein Messgerät für die abgestufte Bestimmung der Materialfeuchte und Wasseraktivität entwickelt und dessen messtechnischer Einsatz untersucht.
Die BAM ist nahezu über die gesamte Wertschöpfungskette hinweg wissenschaftlich tätig. Von der sicheren und effizienten Wasserstofferzeugung (POWER-to-GAS), über die (Zwischen-)Speicherung von Wasserstoff in Druckgasspeichern bis hin zum Transport bspw. mittels Trailerfahrzeug zum Endverbraucher.
Komplettiert werden die Aktivitäten der BAM durch die sicherheitstechnische Beurteilung von wasserstoffhaltigen Gasgemischen, die Verträglichkeitsbewertung von Werkstoffen bis hin zur Detektion von Wasserstoffkonzentrationen über geeignete Sensorik, auch mittels ferngesteuerter Messdrohnen (sog. UAV-Drohnen).
Zudem untersucht die BAM proaktiv Schadensrisiken und Unfallszenarien für die Sicherheitsbetrachtung, um mögliche Schwachstellen aufzeigen und potenzielle Gefährdungen erkennen zu können.
The applicability of three methods developed by finite element analysis (FEM) and proposed in the literature are studied on steel S355. Instrumented indentation tests using spherical indenters of radius 200 and 500 μ m are performed in the macro range at depths of more than 6 μ m. The results of the selected methods are compared with the tensile test. To evaluate the partially strongly varying results, the uncertainties of the calculated strain hardening exponent, n, and yield stress, Y, are estimated. Recommendations for an appropriated procedure of the indentation test are given. The machine compliance and the determination of the zero point of Depth play an essential role. If the certain conditions are considered, the instrumented indentation Tests can be used, in particular for investigations of specimens with inhomogeneous elastoplasticity.
Emissions of ammonia into the environment are mainly caused by agriculture, but also by combustion processes in waste and by road traffic. Even at low concentrations, this substance is not only an odour nuisance, but also a substance with ecological and climatic relevance. Therefore, BAM tested commercial electrochemical, and metal oxide based sensors, which have limited suitability for measuring in the environmental molar fraction range. Alternatively, own developments for the detection of ammonia in the trace range were implemented, wherein the analyte is measured by changing the fluorescence of a BODIPY dye at 550 nm by means of a portable fluorescence sensor directly from the gas phase. For the calibration of ammonia sensors and measuring instruments, a stationary system based on the mixture of certified test gases from pressure cylinders with calibrated mass flow controllers is available. A test gas generator was developed for on-site calibration and testing of sensors and measuring devices. The generation of ammonia-containing gases in the environmental relevant range of levels below 1000 nmol/mol is carried out by the permeation method according to ISO 6145-10. For the traceability of ammonia, standards are provided and further developed by the National Metrological Institutes and designated institutes. Metrological standards are based on SI units and are a basis for traceability of sensors or gas analysers.
Leaking methane from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, BAM developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the copter downwash on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile multicopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available systems and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions.
Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. Nowadays, after a period of failure-free exploitation, a significant increase in fires and explosions due to pipeline leakages, can be observed. Particularly problematic are the gas pipelines in Poland that were built several decades ago. At that time, the technical standards and building regulations were more lenient than those currently being in force. The integrity of the gas pipelines is difficult to inspect as they are not piston-optimized (they were not built for this purpose). To overcome this challenge, the UDT is looking for methods that enable a fast and reliable detection and localization of leaking pipelines over long distances.
The BAM has developed a robotic platform for aerial remote gas sensing that meets the expectations of UDT. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer several advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of minicopters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile octocopter. It enables tomographic reconstruction of gas plumes and a localization of gas sources.
Currently, UDT and BAM are cooperating to develop and validate an effective leakage detection method based on the UAV-REGAS platform. We present first results showing its performance under realistic conditions. Depending on the results, UDT may use this platform in their inspection practice in the near future.
Against the background of sustainable resource management and efficiency, wood-based materials are currently experiencing a revival and, among others, plywood, Laminated Veneer Lumber and glued laminated timber are becoming increasingly more important in the building sector. Even though these materials are so-called engineered products, the element wood is naturally grown with intrinsic variability in mechanical properties and requires professional handling on-site. Otherwise, load-bearing structures made of wood materials may entail certain risks. Critical situations can, in principle, be avoided by implementing a structural health monitoring system into components or structures made from wood material. The aim is to indicate accumulation of mechanical damage and to eliminate or at least significantly reduce the risk of unexpected failure. Toward this purpose, the failure behavior of several layered wood materials under quasi-static tension was investigated in laboratory-scale experiments by means of acoustic emission (AE) measurement. Based on spectral analysis and pattern recognition, two classes of AE signals are identified for each investigated lay-up that are characterized by either low or high frequency contents in the respective power spectra. AE activity and intensity of both signal classes are analyzed, striving for predictors appropriate for AE monitoring concepts.
Against the background of sustainable resource management and efficiency, wood-based materials are currently experiencing a revival and, among others, plywood, Laminated Veneer Lumber and glued laminated timber are becoming increasingly more important in the building sector. Even though these materials are so-called engineered products, the element wood is naturally grown with intrinsic variability in mechanical properties and requires professional handling on-site. Otherwise, load-bearing structures made of wood materials may entail certain risks. Critical situations can, in principle, be avoided by implementing a structural health monitoring system into components or structures made from wood material. The aim is to indicate accumulation of mechanical damage and to eliminate or at least significantly reduce the risk of unexpected failure. Toward this purpose, the failure behavior of several layered wood materials under quasi-static tension was investigated in laboratory-scale experiments by means of acoustic emission (AE) measurement. Based on spectral analysis and pattern recognition, two classes of AE signals are identified for each investigated lay-up that are characterized by either low or high frequency contents in the respective power spectra. AE activity and intensity of both signal classes are analyzed, striving for predictors appropriate for AE monitoring concepts.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
This poster reports an improved outdoor gas source localization algorithm, showing promising results under simulations with a realistic gas plume. In the scenario assumed in this work, an unmanned ground vehicle searches for the location of a gas source in an open outdoor field. The simulated gas plume in this work consists of frequent and large meandering as a real outdoor plume. The source location is estimated using gas and wind measurements obtained from sensors fixed on a mobile platform. When a gas puff is detected, its source is likely to be in the upwind direction. Particle filter-based algorithms have been proposed in previous work to estimate the most likely source location from multiple gas detection events. In this work, the particle weight update function has been modified by adopting a 2D Gaussian plume model, to improve the accuracy in estimating the likelihood of the source location. We have evaluated the performance of this algorithm combined with an estimation-based route planning algorithm. The simulator uses wind data recorded outdoors to calculate transport of gas puffs allowing a formation of a gas plume containing large meandering, due to real fluctuations of outdoor wind. Simulations of the improved particle filter with the estimation-based route planning algorithm have yielded more accurate, stable and time-efficient results than the pre-modified version.
Occupational health is an important topic, especially in industry, where workers are exposed to airborne by-products (e.g., dust particles and gases). Therefore, continuous monitoring of the air quality in industrial environments is crucial to meet safety standards. For practical and economic reasons, high-quality, costly measurements are currently only carried out sparsely, both in time and space, i.e., measurement data are collected in single day campaigns at selected locations only.
The project “Robot-assisted Environmental Monitoring for Air Quality Assessment in Industrial Scenarios” (RASEM) addresses this issue by bringing together the benefits of both – low- and high-cost – measuring technologies enabling costefficient long-term air quality monitoring in realtime: A stationary network of low-cost sensors that is augmented by mobile units carrying high-quality sensors. By mapping the distribution of gases and particles in industrial environments with the proposed RASEM system, measures can be identified to improve on-site working conditions much faster than using traditional methods.
In this paper, we detail the technical aspects of RASEM and introduce the mobile platforms used.
Occupational health is an important topic, especially in industry, where workers are exposed to airborne by-products (e.g., dust particles and gases). Therefore, continuous monitoring of the air quality in industrial environments is crucial to meet safety standards. For practical and economic reasons, high-quality, costly measurements are currently only carried out sparsely, both in time and space, i.e., measurement data are collected in single day campaigns at selected locations only.
The project “Robot-assisted Environmental Monitoring for Air Quality Assessment in Industrial Scenarios” (RASEM) addresses this issue by bringing together the benefits of both – low- and high-cost – measuring technologies enabling cost-efficient long-term air quality monitoring in realtime: A stationary network of low-cost sensors that is augmented by mobile units carrying high-quality sensors. By mapping the distribution of gases and particles in industrial environments with the proposed RASEM system, measures can be identified to improve on-site working conditions much faster than using traditional methods.
In this presentation, we detail the technical aspects of RASEM and introduce the mobile platforms used.
Occupational health is an important topic, especially in industry, where workers are exposed to airborne by-products (e.g., dust particles and gases). Therefore, continuous monitoring of the air quality in industrial environments is crucial to meet safety standards. For practical and economic reasons, high-quality, costly measurements are currently only carried out sparsely, both in time and space, i.e., measurement data are collected in single day campaigns at selected locations only.
The project “Robot-assisted Environmental Monitoring for Air Quality Assessment in Industrial Scenarios” (RASEM) addresses this issue by bringing together the benefits of both – low- and high-cost – measuring technologies enabling cost-efficient long-term air quality monitoring in realtime: A stationary network of low-cost sensors that is augmented by mobile units carrying high-quality sensors. By mapping the distribution of gases and particles in industrial environments with the proposed RASEM system, measures can be identified to improve on-site working conditions much faster than using traditional methods.
In this presentation, we detail the technical aspects of RASEM and introduce the mobile platforms used.
The finite volume method (FVM), like the finite element method (FEM), is a numerical method for determining an approximate solution for partial differential equations. The derivation of the two methods is based on very different considerations, as they have historically evolved from two distinct engineering disciplines, namely solid mechanics and fluid mechanics. This makes FVM difficult to learn for someone familiar with FEM. In this paper we want to show that a slight modification of the FEM procedure leads to an alternative derivation of the FVM. Both numerical methods are starting from the same strong formulation of the problem represented by differential equations, which are only satisfied by their exact solution. For an approximation of the exact solution, the strong formulation must be converted to a so-called weak form. From here on, the two numerical methods differ. By appropriate choice of the trial function and the test function, we can obtain different numerical methods for solving the weak formulation of the problem. While typically in FEM the basis functions of the trial function and test function are identical, in FVM they are chosen differently. In this paper, we show which trial and test function must be chosen to derive the FVM alternatively: The trial function of the FVM is a “shifted” trial function of the FEM, where the nodal points are now located in the middle of an integration interval rather than at the ends. Moreover, the basis functions of the test function are no longer the same as those of the trial function as in the FEM, but are shown to be a constant equal to 1. This is demonstrated by the example of a 1D Poisson equation.
The best-known discretization methods for solving engineering problems formulated as partial differential equations are finite difference method (FDM), finite element method (FEM) and finite volume method (FVM). While the finite volume method is used in fluid mechanics, the finite element method is predominant in solid state mechanics. At first glance, FVM and FEM are two highly specialized methods. However, both methods can solve problems of both solid mechanics and fluid mechanics well. Since experimental mechanics deals not only with solid state physics but also with fluid mechanics problems, we want to understand FVM in the sense of FEM in this work. In the long term, we want to use the variational calculus to unify many important numerical methods in engineering science into a common framework. In this way, we expect that experiences can be better exchanged between different engineering sciences and thus innovations in the field of experimental mechanics can be advanced. But in this work, we limit ourselves to the understanding of the FVM with the help of the variational calculus already known in FEM. We use a simple 1D Poisson equation to clarify the point. First, we briefly summarize the FVM and FEM. Then we will deal with the actual topic of this paper, as we establish the FEM and the FVM on a common basis by variation formulation. It is shown here that the FVM can be understood in terms of the finite element method with the so-called Galerkin-Petrov approach.
The best-known discretization methods for solving engineering problems formulated as partial differential equations are finite difference method (FDM), finite element method (FEM) and finite volume method (FVM). While the finite volume method is used in fluid mechanics, the finite element method is predominant in solid state mechanics. At first glance, FVM and FEM are two highly specialized methods. However, both methods can solve problems of both solid mechanics and fluid mechanics well. Since experimental mechanics deals not only with solid state physics but also with fluid mechanics problems, we want to understand FVM in the sense of FEM in this work. In the long term, we want to use the variational calculus to unify many important numerical methods in engineering science into a common framework. In this way, we expect that experiences can be better exchanged between different engineering sciences and thus innovations in the field of experimental mechanics can be advanced. But in this work, we limit ourselves to the understanding of the FVM with the help of the variational calculus already known in FEM. We use a simple 1D Poisson equation to clarify the point. First, we briefly summarize the FVM and FEM. Then we will deal with the actual topic of this paper, as we establish the FEM and the FVM on a common basis by variation formulation. It is shown here that the FVM can be understood in terms of the finite element method with the so-called Galerkin-Petrov approach.
The transfer of data for the metrological traceability of measurement results is currently taking place in the form of paper-based calibration certificates, mostly. Especially accredited metrology services providers are often bound to paper certificates by regulatory constrictions and sometimes lack of IT-infrastructure. This analog form of metrology data transfer, however, implies hands-on work, in particular for the certificate receiver, as its key values need to be translated into the device- and quality management (QM) system, manually. With thousands of certificates transferred from accredited calibration labs until the industrial regime, this binds a significant amount of human resources and is a well-known source of errors, thus constricting cost-effective and secure workflows.
This contribution highlights the status of the advancing digital transformation in metrology, on the example of force calibration. Although this appealing initiative is to a large extend driven by German stakeholders, it currently evolves to extend across all Europe and far beyond.
The testing of gas and humidity sensors is essential for the application of sensing devices. The testing determines properties of an investigated humidity sensor or gas sensor. In testing, the sensor property is the observed response of a sensing system to an input stimulus in comparison to a reference within a test procedure. This tutorial is structured into six chapters. The first chapter is about basics of hygrometry and gas sensing. It includes definitions, sensor classification, overview of application categories, as well as construction and functional principles. The chapter on requirements of deployed sensors focus on stability, response time, cross-sensitivity, electrical and mechanical requirements, and other. The sensing performance is characterised by determinations of parameters like accuracy, repeatability, detection limits (low and high), and response/recovery time. The description of testing signals on specified qualitative and quantitative characteristics, and the adequately estimated measurement uncertainty is the content of the analysis chapter. All chapters contain examples of testing procedures from testing/calibration labs for hygrometers and gas sensors which are essential for implementation into quality management systems.
This work presents the testing of a developed elec¬tronic nose for outdoor odour nuisance monitoring. The sensor system consists of a sampling system, a measuring cell equipped with commercially available low-cost gas sensor elements and a data acquisition system. The sensor testing showed that the developed prototype is able to distinguish, identify and partially quantify individual odorous substances like ethanol, ammonia and hydrogen sulphide. Ethanol and ammonia could even be detected below or near their odour threshold.
This work presents the testing of a developed electronic nose for outdoor odour nuisance monitoring. The sensor system consists of a sampling system, a measuring cell equipped with commercially available low-cost gas sensor elements and a data acquisition system. The sensor testing showed that the developed prototype is able to distinguish, identify and partially quantify individual odorous substances like ethanol, ammonia and hydrogen sulphide. Ethanol and ammonia could even be detected below or near their odour threshold.
Fluorides are well-known as wood preservatives. One of the limitations of fluoride-based wood preservatives is their high leachability. Alternative to current fluoride salts such as NaF used in wood protection are low water-soluble fluorides. However, impregnation of low water-soluble fluorides into wood poses a challenge. To address this challenge, low water-soluble fluorides like calcium fluoride (CaF2) and magnesium fluoride (MgF2) were synthesized as nanoparticles via the fluorolytic sol−gel synthesis and then impregnated into wood specimens. In this study, the toxicity of nano metal fluorides was assessed by termite mortality, mass loss and visual analysis of treated specimens after eight weeks of exposure to termites, Coptotermes formosanus. Nano metal fluorides with sol concentrations of 0.5 M and higher were found to be effective against termites resulting in 100% termite mortality and significantly inhibited termite feeding. Among the formulations tested, the least damage was found for specimens treated with combinations of CaF2 and MgF2 with an average mass loss less than 1% and visual rating of “1”. These results demonstrate the efficacy of low water-soluble nano metal fluorides to protect wood from termite attack.
Temperature characteristics of a piezoresistive accelerometer for high impact shock application
(2018)
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
Temperature characteristics of a piezoresistive accelerometer for high impact shock application
(2018)
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
Gas distribution mapping is important to have an accurate understanding of gas concentration levels in hazardous environments. A major problem is that in-situ gas sensors are only able to measure concentrations at their specific location. The gas distribution in-between the sampling locations must therefore be modeled. In this research, we interpret the task of spatial interpolation between sparsely distributed sensors as a task of enhancing an image's resolution, namely super-resolution. Because autoencoders are proven to perform well for this super-resolution task, we trained a convolutional encoder-decoder neural network to map the gas distribution over a spatially sparse sensor network. Due to the difficulty to collect real-world gas distribution data and missing ground truth, we used synthetic data generated with a gas distribution simulator for training and evaluation of the model. Our results show that the neural network was able to learn the behavior of gas plumes and outperforms simpler interpolation techniques.
Gas distribution mapping is important to have an accurate understanding of gas concentration levels in hazardous environments. A major problem is that in-situ gas sensors are only able to measure concentrations at their specific location. The gas distribution in-between the sampling locations must therefore be modeled. In this research, we interpret the task of spatial interpolation between sparsely distributed sensors as a task of enhancing an image's resolution, namely super-resolution. Because autoencoders are proven to perform well for this super-resolution task, we trained a convolutional encoder-decoder neural network to map the gas distribution over a spatially sparse sensor network. Due to the difficulty to collect real-world gas distribution data and missing ground truth, we used synthetic data generated with a gas distribution simulator for training and evaluation of the model. Our results show that the neural network was able to learn the behavior of gas plumes and outperforms simpler interpolation techniques.
In civil engineering, many structures are made of reinforced concrete. Most Degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture.
Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days.
Moreover, long-term moisture monitoring is performed for more than 1000 days. The Experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
Simulating a Gas Source Localization Algorithm with Gas Dispersion Produced by Recorded Outdoor Wind
(2022)
This presentation reports the use of the first gas dispersion simulator capable of generating large wind fluctuation, to test a modification to a gas source localization algorithm and study how the change affects it. Gas source localization at an outdoor environment is a challenging task mainly due to the complexity of the spreading gas caused by the unpredictable nature of constantly changing wind. Therefore, a novel use of outdoor wind in developing a gas source localization system by simulation will be shared. To consider the characteristic of sudden but large and unpredictable changes in wind direction, recorded outdoor wind was used to simulate a realistic outdoor gas dispersion which has been done for the first time. With the use of this simulator, a modification to a mobile robot-based gas source localization algorithm was evaluated. Multiple simulations of the modified and the original algorithm were done to study the effect of the tested modification. The results showed that a small difference in the algorithm can greatly impact the results. From this study, we consider the use of simulation consisting of the necessary traits to evaluate outdoor gas source localization, has the potential to accelerate the development of a reliable localization system.
Simulating a Gas Source Localization Algorithm with Gas Dispersion Produced by Recorded Outdoor Wind
(2023)
This paper reports the use of the first gas dispersion simulator capable of introducing large wind fluctuations into simulations. The proposed simulator enables testing of a modification made to a gas source localization algorithm in a realistic scenario in order to study how the change affects it. Gas source localization in an outdoor environment is a challenging task mainly due to the complexity of the gas spread caused by the unpredictable nature of constantly changing wind. Therefore, a novel use of outdoor wind in developing a gas source localization system by simulation is presented in this paper. To consider the characteristic of sudden but large and unpredictable changes in wind direction, we propose to use recorded outdoor wind to simulate a realistic outdoor gas dispersion which has been done for the first time to the best of our knowledge. With the use of this simulator, we have tested a modification to a mobile robot-based gas source localization algorithm. Multiple simulations of the modified and the original particle filter-based algorithm have been done to study the effect of the tested modification. The results showed that a small difference in the algorithm can greatly impact the results. From this study, we show that the use of simulation consisting of the necessary traits to evaluate outdoor gas source localization, has the potential to accelerate the development of a reliable localization system.
The determination of the measurement uncertainty of quantitative and qualitative results is an important quality management tool, for example to describe measuring equipment, procedures, measurement results and the quality of products. The lecture presents the process description for the determination of the measurement uncertainty according to GUM, the determination of uncertainties in qualitative measurement results and the application of the measurement uncertainty for conformity assessment.