Analytische Chemie
Filtern
Erscheinungsjahr
- 2022 (615) (entfernen)
Dokumenttyp
- Vortrag (217)
- Zeitschriftenartikel (191)
- Posterpräsentation (89)
- Beitrag zu einem Tagungsband (59)
- Forschungsbericht (17)
- Sonstiges (15)
- Forschungsdatensatz (10)
- Buchkapitel (7)
- Dissertation (2)
- Handbuch (2)
Sprache
- Englisch (529)
- Deutsch (85)
- Mehrsprachig (1)
Schlagworte
- Fluorescence (24)
- Digitalization (22)
- Certification (20)
- Conformity assessment (20)
- COVID-19 (19)
- Digital transformation (19)
- Sensor (19)
- Calibration (18)
- Conformity assessment body (18)
- Quality infrastructure (18)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (235)
- 1 Analytische Chemie; Referenzmaterialien (215)
- 6 Materialchemie (111)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (54)
- 8.4 Akustische und elektromagnetische Verfahren (53)
- 8.0 Abteilungsleitung und andere (52)
- 1.1 Anorganische Spurenanalytik (44)
- 8.5 Röntgenbildgebung (44)
- 6.1 Oberflächen- und Dünnschichtanalyse (42)
- 1.2 Biophotonik (40)
- 6.3 Strukturanalytik (40)
- 1.8 Umweltanalytik (35)
- S Qualitätsinfrastruktur (32)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (31)
- S.2 Digitalisierung der Qualitätsinfrastruktur (30)
- 1.3 Instrumentelle Analytik (28)
- 4 Material und Umwelt (27)
- 1.4 Prozessanalytik (26)
- 1.9 Chemische und optische Sensorik (21)
- 8.6 Faseroptische Sensorik (20)
- 1.7 Organische Spuren- und Lebensmittelanalytik (19)
- 6.6 Physik und chemische Analytik der Polymere (19)
- 1.5 Proteinanalytik (18)
- 1.6 Anorganische Referenzmaterialien (16)
- VP Vizepräsident (16)
- VP.1 eScience (16)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (15)
- 6.0 Abteilungsleitung und andere (14)
- 4.3 Schadstofftransfer und Umwelttechnologien (10)
- 4.2 Material-Mikrobiom Wechselwirkungen (9)
- 7 Bauwerkssicherheit (9)
- 9 Komponentensicherheit (9)
- 3 Gefahrgutumschließungen; Energiespeicher (7)
- 4.5 Kunst- und Kulturgutanalyse (6)
- 5 Werkstofftechnik (5)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (4)
- 9.0 Abteilungsleitung und andere (4)
- 5.1 Mikrostruktur Design und Degradation (3)
- 6.2 Material- und Oberflächentechnologien (3)
- 7.4 Baustofftechnologie (3)
- 7.6 Korrosion und Korrosionsschutz (3)
- 9.5 Tribologie und Verschleißschutz (3)
- 1.0 Abteilungsleitung und andere (2)
- 2 Prozess- und Anlagensicherheit (2)
- 3.5 Sicherheit von Gasspeichern (2)
- 4.1 Biologische Materialschädigung und Referenzorganismen (2)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (2)
- 5.4 Multimateriale Fertigungsprozesse (2)
- 9.4 Integrität von Schweißverbindungen (2)
- P Präsident (2)
- P.0 Präsident und andere (2)
- S.1 Qualität im Prüfwesen (2)
- 2.1 Sicherheit von Energieträgern (1)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (1)
- 3.2 Gefahrguttanks und Unfallmechanik (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 6.7 Materialsynthese und Design (1)
- 7.1 Baustoffe (1)
- 7.3 Brandingenieurwesen (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
- 7.7 Modellierung und Simulation (1)
- 9.2 Versuchsanlagen und Prüftechnik (1)
- 9.6 Additive Fertigung metallischer Komponenten (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (5)
Validation of a fast and traceable radiographic scale calibration of dimensional computed tomography
(2022)
A fast and highly precise method of determining the geometrical scale factor of computed tomography (CT) measurements has been validated successfully by Bundesanstalt für Materialforschung und -prüfung (BAM), the Federal Institute of Metrology (METAS) and Physikalisch-Technische Bundesanstalt (PTB) within the scope of AdvanCT (Advanced Computed Tomography for dimensional and surface measurements in industry), a project funded in the European Metrology Programme for Innovation and Research (EMPIR). The method has been developed by PTB and requires only two radiographic images of a calibrated thin 2D standard (hole grid standard) from two opposite directions. The mean grid distance is determined from both radiographs. From this and with the help of the calibration result, the radiographic scale and therefore the voxel size is determined. The procedure takes only a few minutes and avoids a time-consuming CT scan. To validate the method, the voxel sizes determined via this method were compared with voxel sizes determined from CT scans of calibrated objects. Relative deviations between the voxel sizes in the range of 10−5 were
achieved with minimal effort using cone-beam CT systems at moderate magnifications.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is increasingly used to study the distribution of metal-containing drugs, imaging probes and nanomaterials in connection with disease related changes and therapy progress. Additionally, biomolecules can be detected indirectly by using metal-tagged antibodies.
The extracellular matrix (ECM) is, besides the cells, an important component of all body tissues. The macromolecular network of the ECM consists of structural proteins (e.g., collagen, elastin) and proteoglycans composed of highly negatively charged carbohydrates, the glycosaminoglycans (GAGs), which are covalently linked to a protein core. Many diseases, including inflammatory processes and tumors, are associated with characteristic ECM changes at an early stage. Recent studies have shown that contrast agents for magnetic resonance imaging (MRI), which are based on gadolinium containing chelate complexes or iron oxide nanoparticles, can bind themselves to ECM components.
To elucidate the role of GAGs like keratan sulfate (KS) and its modification state in disease, highly specific tools are necessary. As a complement to conventional immunohistochemistry LA-ICP-MS was applied to investigate the distribution of KS in tissue thin sections using a well characterized anti-KS antibody labelled with metal ions. Furthermore, LA-ICP-MS was used for the detection of MRI contrast agents and the identification of their target cells and molecules in tissue samples from animal models, e.g. for cardiovascular diseases. The results show the possibilities of LA-ICP-MS for the elucidation of pathological tissue changes.
Probe diagnostics is used to determine the electron temperature and electron number density in a low pressure inductively coupled plasma (ICP) ignited in the mixture of SiF4, Ar and H2. Emission spectra of mixtures with different stoichiometry of components are investigated and the electron density distribution function (EDDF) is estimated. The optimal conditions for high conversion of SiF4 into Si are found by studying the dependence of the yield of silicon upon the ratio of reagents. The maximum achieved yield of silicon is 85% under the optimal conditions. Based on the analysis of IR and MS spectra of exhaust gases, 5% of initial SiF4 converts into volatile fluorosilanes. A rate of production of Si is 0.9 g/h at the energy consumption 0.56 kWh /g.
Nanoforms with at least one dimension below 100 nm have an important part to play in more and more areas of our daily life. Therefore, risk assessment of these materials is becoming increasingly important. In this context, the European Chemical Agency (ECHA) considered eleven physico-chemical properties as relevant, of which the following six are essential for the registration: chemical composition, crystallinity, particle size, particle shape, surface chemistry and specific surface area. Four of these priority properties can be obtained with electron microscopy and surface analytics like XPS and ToF-SIMS. The reliability of this data must be ensured, especially for their use for grouping and read across approaches. On the other hand, the “reproducibility” crisis has revealed major shortcomings in the reliability of published data.
In a case study, we show how the quality of the data can be ensured by using existing standards and protocols of each step in the workflow of sample characterization. As exemplary samples, two Al-coated TiO2 samples as nanopowders were selected from the JRC repository, capped either with a hydrophilic or a hydrophobic organic ultrathin shell. SEM results provided the size and shape of the nanoparticles, a first overview about the composition was obtained with EDS. XPS and ToF-SIMS supplied the surface chemistry, especially information about the shell and the coating of the particles. Standards and protocols of all steps of the analytical workflow including preparation and data reduction are discussed regarding reliable and reproducible data. Additionally, uncertainties for the different steps are specified.
Only such a detailed description of all these factors allows a comprehensive physico-chemical characterization of the nanoparticles with understanding of their potential risk assessment.
The recent development of x-ray photoelectron spectroscopy using excitation sources different from the usual lab-source Mg Kα and Al Kα and spectrometers with more sophisticated lens systems requires flexible approaches for determining the transmission function. Therefore, the approach using quantified peak areas (QPA) was refined.1 A new algorithm allows a more precise estimation of the transmission function which could be shown by comparing the results obtained with the new version with former calculations. Furthermore, next to the established reference materials Cu, Ag and Au, ionic liquids can be used for estimating the transmission function at beamlines with variable excitation energies. Comparison between the measured and stoichiometric composition shows that a transmission function was determined which allows a reasonable quantification.
microscopy (AFM), or X-ray reflectometry. For the additional determination of thin film composition, techniques like X-ray photoelectron spectroscopy (XPS) or mass spectrometry-based techniques can be used. An alternative non-destructive technique is electron probe microanalysis (EPMA). This method assumes a sample of homogenous (bulk) chemical composition, so that it cannot be usually applied to thin film samples. However, in combination with the thin film software StrataGEM, the thickness as well as the composition of such films on a substrate can be determined.
This has been demonstrated for FeNi on Si and SiGe on Al2O3 film systems. For both systems five samples with different elemental composition and a reference were produced and characterised by Korean research institute KRISS using inductively coupled plasma mass spectrometry (ICP-MS), Rutherford backscattering (RBS), and transmission electron microscopy (TEM). These samples were used for an international round robin test.
In 2021, a new and open-source thin film evaluation programme called BadgerFilm has been released. It can also be used to determine thin film composition and thickness from intensity ratios of the unknown sample and standards (k-ratios).
In this contribution, we re-evaluated the data acquired for the FeNi and SiGe systems using the BadgerFilm software package and compared the resulting composition and thickness with the results of the established StrataGEM software and other reference methods. With the current evaluation, the BadgerFilm software shows good agreement with the composition and thickness calculated by StrataGEM and as the reference values provided by the KRISS.
The residual stresses and load transfer in multiphase metal alloys and their composites (with both random planar-oriented short fibers and particles) will be shown, as studied by neutron diffraction, by X-ray computed tomography, and by a model based on the reformulation of classic Maxwell’s homogenization method.
Contrary to common understanding and state-of-the-art models, we experimentally observe that randomly oriented phases possess non-hydrostatic residual stress. Moreover, we disclose that the unreinforced matrix alloy stays under hydrostatic compression even under external uniaxial compression.
The recently developed modeling approach allows calculating the residual stress in all phases of the composites. It rationalizes the presence of deviatoric stresses accounting for the interaction of random oriented phases with fibers having preferential orientation. It also allows the explanation of the unconventional in-situ behavior of the unreinforced alloy and the prediction of the micromechanical behavior of other similar alloys.
Im Rahmen des EMPIR-Projektes NanoXSpot (Nanometre X-Ray Focal Spot Measurement) werden rückführbare Messverfahren zur Bestimmung der Brennfleckgröße und -form von Röntgenröhren mit Submikrometerauflösung (100 nm – 20 µm) entwickelt, die die Grundlage für die Erarbeitung eines Standardentwurfes bilden. Der Standardentwurf wird bei CEN TC 138 (Non-destructive testing) WG 1 (Radiographic testing) eingereicht und mit ISO und ASTM harmonisiert. Zur Untersuchung der entwickelten Methoden (Brennfleck-CT, Fit-Prozedur für Strichgruppenkörper) und des im Projekt NanoXSpot neu entworfenen Testkörpers, NxS, wurde ein Ringversuch durchgeführt. Dabei wurde sowohl der angestrebte Überlappungsbereich mit EN 12543 Teil 5 (Messung der effektiven Brennfleckgröße von Mini- und Mikrofokus-Röntgenröhren) und ASTM E 2903 (Standard Test Method for Measurement of the Effective Focal Spot Size of Mini and Micro Focus X-ray Tubes) für Brennflecke >5 µm als auch Brennflecke <5 µm untersucht. Im Mittelpunkt standen dabei Stabilität und Wiederholbarkeit der entwickelten Methoden zur Bestimmung der Brennfleckgröße. In diesem Beitrag werden die Ergebnisse des durchgeführten Ringversuches vorgestellt und diskutiert, um Schlussfolgerungen und Empfehlungen für die Vorbereitung eines erweiterten Ringversuchs mit Partnern und Stakeholdern abzuleiten.
Even though we often do not knowingly recognize them, nanoparticles are present these days in most areas of our daily life, including food and its packaging, medicine, pharmaceuticals, cosmetics, pigments as well as electronic products, such as computer screens. The majority of these particles exhibits a core-shell morphology either intendedly or unintendedly. For the purpose of practicability, this core-shell nanoparticle (CSNP) morphology is often assumed to be ideal, namely a spherical core fully encapsulated by a shell of homogeneous thickness with a sharp interface between core and shell material. It is furthermore widely presumed that all nanoparticles in the sample possess the same shell thickness. As a matter of fact, most real CSNPs deviate in several ways from this ideal model with quite often severe impact on how efficiently they perform in a specific application.
The topic of this cumulative PhD thesis is the accurate characterization of the actual morphology of CSNPs by advanced X-ray analytical techniques, namely X-ray photoelectron spectroscopy (XPS) and scanning transmission X-ray microscopy (STXM). A special focus is on CSNPs which deviate from an ideal core-shell morphology. In the paper from 2019 nanoparticle shell thicknesses are extracted from the elastic-peak intensities in an XPS spectrum based on an ideal particle morphology. This happens for a series of CSNP samples comprising a poly(tetrafluoroethylene) (PTFE) core and either a poly(methyl methacrylate) (PMMA) or polystyrene (PS) shell. The same paper as well as the paper from 2020 demonstrate for the first time, that the analysis of the inelastic background in an XPS spectrum of CSNPs can identify and quantify the heterogeneity of the shell and the incomplete encapsulation of the core.
The result from an XPS experiment is always an average across a large nanoparticle ensemble. Deviations from an ideal morphology within a single particle of the sample cannot be assessed separately. As opposed to that, a spatial resolution of 35 nm enables STXM to visualize the interior of single CSNPs which exhibit a sufficient X-ray absorption contrast between core and shell material. In the paper from 2018 a STXM analysis is demonstrated based on the example of the PTFE-PS CSNP samples already mentioned in the previous paragraph.
In the publication from 2021 (Ca/Sr)F₂ core-shell like nanoparticle ensembles for the practical use in, among others, antireflective coatings are investigated. These nanoparticles do not possess a sharp interface between core and shell material, which is why a shell thickness determination as described in the second paragraph is inappropriate. Instead, in-depth profiles of the chemical composition are obtained by XPS experiments based on synchrotron radiation with variable X-ray photon energy to elucidate the internal morphology of the particles. Additionally, theoretical in-depth profiles of Ca and Sr XPS peak intensities are simulated, in order to facilitate the interpretation of the experiments. Thus, an enrichment of CaF₂ at the particle surface was determined, which could hardly have been assessed by any other analytical technique. Because this kind of non-destructive depth profiling by XPS is very demanding, more than usual effort is spent on gapless documentation of the experiments to ensure full reproducibility.
Due to the vast diversity of nanoparticles differing in material, composition and shape, a measurement procedure cannot unalteredly be transferred from one sample to another. Nevertheless, because the papers in this thesis present a greater depth of reporting on the experiments than comparable publications, they constitute an important guidance for other scientists on how to obtain meaningful information about CSNPs from surface analysis.
The fabrication of laser-generated surface structures on titanium and titanium alloys has recently gained remarkable interests, being technologically relevant for applications in optics, medicine, fluid transport, tribology, and wetting of surfaces. The morphology of these structures, and so their chemistry, is influenced by the different laser processing parameters such as the laser fluence, wavelength, pulse repetition rate, the effective number of laser pulses per beam spot area, etc. A simple way to characterize laser-generated surface structures is by means of optical microscopy (OM) or white light interference microscopy (WLIM). The latter can address the surface topography, while having a lateral resolution limit of ~(lambda)/2 (lambda = illumination wavelength). To resolve morphologies with spatial periods significantly smaller than (lambda)/2, scanning electron microscopy (SEM) is often used, taking benefit of the reduced de Broglie wavelength associated to the electrons of several keV energy. However, all the above-mentioned techniques lack the necessary depth-resolution to reveal and quantify sub-surface material modifications of these laser-generated structures. Time-of-Flight secondary ion mass spectrometry (ToF-SIMS) represents a promising surface analytical technique for studying laser-induced chemical surface alterations since the method combines a high surface sensitivity with the capability to perform a depth-profiling of the laser-affected surface zone. In this study we combine WLIM and high-resolution SEM with ToF-SIMS to fully characterize the evolution of various types of laser-generated micro- and nanostructures formed on Ti-6Al-4V alloys upon irradiation by near infrared ultrashort laser pulses (1030 nm, 925 fs) at different laser fluence levels, effective number of pulses, and at different pulse repetition rates (1 – 400 kHz). We show how this combined surface analytical approach allows to evaluate alterations in the surface chemistry and topography of the laser-generated surface structures depending on the laser processing parameters
We demonstrate here using a disulfide system the first example of reversible, selective, and quantitative transformation between three crystalline polymorphs by ball mill grinding. This includes the discovery of a previously unknown polymorph. Each polymorph is reproducibly obtained under well-defined neat or liquid-assisted grinding conditions, revealing subtle control over the apparent thermodynamic stability. We discovered that the presence of a contaminant as low as 1.5% mol mol−1 acting as a template is required to enable all these three polymorph transformations. The relative stabilities of the polymorphs are determined by the sizes of the nanocrystals produced under different conditions and by surface interactions with small amounts of added solvent. For the first time, we show evidence that each of the three polymorphs is obtained with a unique and reproducible crystalline size. This mechanochemical approach gives access to bulk quantities of metastable polymorphs that are inaccessible through recrystallisation.
Seit Jahren stellt die luftgekoppelte Ultraschallprüfung eine etablierte Alternative zur konventionellen Prüfung von Leichtbaukomponenten aus den Bereichen Luft- und Raumfahrt sowie Automotive dar. Im Gegenteil zur flüssigkeitsgekoppelten Prüfung in Kontakt oder im Tauchbecken ist sie weniger invasiv und bietet daher zeitliche und finanzielle Anreize.
Normalerweise wird die luftgekoppelte Prüfung mit Einzelelementschwingern in Durchschallung realisiert, wohingegen die Gruppenstrahlertechnik bereits Industriestandard im Bereich der Kontakttechnik darstellt. Die damit verbundenen Vorteile wie die aktive Fokussierung oder, die gezielte Manipulation des Einschallwinkels zur Anregung von geführten Wellen, finden im Bereich der luftgekoppelten Prüfung dabei noch wenig Anwendung.
Im Rahmen dieses Beitrags stellen wir die ersten Zwischenergebnisse des geförderten Projektes „PALUP – Phased- Array-Technik für Luftultraschall-Prüfungen“ vor. Ziel des Projektes ist die Entwicklung von Mehrelementschwingern auf Basis von zellulären Kunststoffen, die Entwicklung einer dedizierten Pulserstufe im Kilovoltbereich, sowie die nötige rauscharme messtechnische Auswertung jedes Einzelelements.
Seit Jahren stellt die luftgekoppelte Ultraschallprüfung eine etablierte Alternative zur konventionellen Prüfung von Leichtbaukomponenten aus den Bereichen Luft- und Raumfahrt sowie Automotive dar. Im Gegenteil zur flüssigkeitsgekoppelten Prüfung in Kontakt oder im Tauchbecken ist sie weniger invasiv und bietet daher zeitliche und finanzielle Anreize.
Normalerweise wird die luftgekoppelte Prüfung mit Einzelelementschwingern in Durchschallung realisiert, wohingegen die Gruppenstrahlertechnik bereits Industriestandard im Bereich der Kontakttechnik darstellt. Die damit verbundenen Vorteile wie die aktive Fokussierung oder, die gezielte Manipulation des Einschallwinkels zur Anregung von geführten Wellen, finden im Bereich der luftgekoppelten Prüfung dabei noch wenig Anwendung.
Im Rahmen dieses Beitrags stellen wir die ersten Zwischenergebnisse des geförderten Projektes „PALUP – Phased- Array-Technik für Luftultraschall-Prüfungen“ vor. Ziel des Projektes ist die Entwicklung von Mehrelementschwingern auf Basis von zellulären Kunststoffen, die Entwicklung einer dedizierten Pulserstufe im Kilovoltbereich, sowie die nötige rauscharme messtechnische Auswertung jedes Einzelelements.
Zur Simulation des Schallfeldes von beliebig geformten konventionellen Schallquellen existieren viele Ansätze (EFIT, GPSS). Sie alle basieren auf der Annahme eines monochromatischen akustischen Signals, was meist eine gültige Annäherung darstellt. Allerdings sind bei thermoakustischen Quellen aufgrund ihrer Funktionsweise und der hohen Bandbreite viele der existierenden Ansätze nicht direkt anwendbar und können Beobachtungen bei der Vermessung von thermoakustischen Wandlern nicht vollständig abbilden und erklären.
In diesem Beitrag wurde die bekannte Methode der generalisierten Punktquellensynthese (GPSS) für die Berechnung von Schallfeldern von thermoakustischen Schallquellen angewendet. Dabei gehen zahlreiche Parameter wie die Dicke und Geometrie der leitfähigen Schicht, Krümmung des Substrats, sowie die Signalform der Anregung in die Simulation ein. Neu an dem präsentierten Ansatz ist die Abweichung von der üblichen monochromatischen Annäherung und die Berücksichtigung der großen Bandbreite von thermoakustischen Wandlern. Für die Validierung der Simulationen wurden Schallfelder von Quellen mit bekannter Anregung und Geometrie breitbandig durch ein optisches Mikrofon vermessen.
The overview of the activity of group 8.5 Micro-NDT (BAM, Belin, Germany) in the field of additively manufacturing material characterization will be presented. The challenges in the residual stress analysis of AM components are discussed on the basis on the show studies performed in BAM. Also, the synchrotron X-ray refraction technique, available in BAM, is presented, showing example of in-situ heating test of Al10SiMg AM material.
Till now application of printed magnetoelectronics is hindered by lack of large area exchange coupled metallic multilayers required to produce printable magneto-sensory inks. Large-scale roll-to-roll (R2R) fabrication process is an attractive approach owing to its capabilities for high volume, high throughput, and large area manufacturing. Precise and high performance R2R sputtering technology is developed to fabricate large area giant magnetoresistive (GMR) thin-films stacks that contain 30 metallic bilayers prepared by continuous R2R sputtering of Co and Cu sequential on a hundred meters long polyethylene terephthalate (PET) web. The R2R sputtered Co/Cu multilayer on a 0.2 × 100 m2 PET web exhibits a GMR ratio of ≈40% achieving the largest area exchange coupled room temperature magneto-sensitive system demonstrated to date. The prepared GMR thin-film is converted to magnetosensitive ink that enables printing of magnetic sensors with high performance in a cost-efficient way, which promotes integration with printed electronics. An average GMR ratio of ≈18% is obtained for 370 printed magnetic sensors. The realized precise R2R sputtering approach can also be extended to a wide range of hybrid thin-film material systems opening up a path for new functional inks applied with printing technologies.
Acoustic methods are ideally suited for determining the mechanical properties of different materials non-destructively. The availability of such methods is particularly important for fiber-reinforced polymers (FRPs) because their properties strongly depend on the manufacturing process and in-service conditions. Since FRPs are mostly used in thin-walled components, properties can be derived from the dispersion curves of ultrasonic guided waves (UGWs).
Our approach is based on an inverse procedure in which the numerically calcu-lated dispersion curves are fitted to the measured curves. The acquisition is done by applying a broadband piezoelectric transducer (PZT) to excite and a 3D laser Doppler vibrometer (3D LDV) to record the waves. Compared to the ap-proaches based on laser excitation, the PZT provides a better signal-to-noise ra-tio because more energy is brought into the structure. Whereas the 3D LDV compared to a 1D LDV or a PZT allows capturing in-plane and out-of-plane components and thus providing more dispersion information. Since the inverse procedure requires many iterations before elastic properties are retrieved, an ef-ficient tool for the calculation of the dispersion curves is necessary. For this, the Scaled Boundary Finite Element Method is used. All in all, a good agreement between theoretical and experimental curves is demonstrated.
Several aspects were explored towards the standardization of a suitable procedure. The use of gaseous standards is necessary and a standard gas mixture containing 60 substances was successfully generated and employed for further investigations. The suitability of different chromatography columns was addressed: The use of PLOT (Porous Layer Open Tubular) columns is well suitable for VVOC analysis. The recoveries of the 60 analytes on several adsorbents and their combinations were determined: A combination of a graphitized carbon black and a carbon molecular sieve showed great results for all analytes. Carbon molecular sieves adsorb water which can impair the analysis. Different options such as purging, the use of a drying system or splitting were investigated for water removal. This contribution will present experimental results supporting the standardization of a method for VVOC analysis.
EXAFS analysis of pure elements, binary and ternary equiatomic refractory alloys within the Nb-Zr-Ti-Hf- Ta system is performed at the Nb and Zr K-edges to analyze the evolution of the chemical local environ- ment and the lattice distortion. A good mixing of the elements is found at the atomic scale. For some compounds, a distribution of distances between the central atom and its neighbors suggests a distortion of the structure. Finally, analysis of the Debye-Waller parameters shows some correlation with the lat- tice distortion parameter δ², and allows to quantify experimentally the static disorder in medium entropy alloys.
Fire-gilding is a historic technique for the application of golden layers on a number of different base materials utilizing a gold amalgam. This technique leaves a significant amount of Hg in the golden layer, giving archeometrists a reliable indicator to identify firegildings.
Recent findings on presumably fire-gilded objects have shown in several cases significantly lower Hg content than previously studied objects. This prompted a synchrotron-based X-ray fluorescence investigation into the Hg distribution along the material–gilding interface, as well as a series of measurements regarding the Hg content development in fire-gilded samples during artificial aging. This work presents findings on laboratory-prepared fire-gildings, indicating an Hg enrichment at the interface of firegilded silver samples. Notably, such an enrichment is missing in fire-gilded copper samples. Further, it is confirmed that fire-gilded layers typically do not undercut an Hg bulk content of 5%. In this light, it seems improbable that ancient samples that contain <5% Hg are fire-gilded. The results presented in this study might lead to a non-destructive method to identify the Hg enrichment at the interface. This might be obtained by a combination of different non-destructive measurements and might also work unambiguously in samples in which the gold top layer is altered.