Analytische Chemie
Filtern
Dokumenttyp
- Posterpräsentation (18) (entfernen)
Sprache
- Englisch (18) (entfernen)
Referierte Publikation
- nein (18)
Schlagworte
- Laser thermography (5)
- Super resolution (5)
- Joint sparsity (4)
- VCSEL array (4)
- Virtual wave (4)
- 1d laser (3)
- High-power laser (3)
- Laser array (3)
- Circular economy (2)
- Curing Monitoring (2)
Organisationseinheit der BAM
- 8.0 Abteilungsleitung und andere (18) (entfernen)
Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for examination of material defects. Material defects are often simulated by flat-bottom holes (FBH) or grooves. Typically, analytical 1D models are used to determine the defect depth of FBHs, grooves or delaminations. However, these models cannot take into account lateral heat flows, or only to a limited extent (semi-empirical model). They are therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Here, we present an approach for quantitative determination of the geometry of FBH or grooves. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a FBHs or groove and its diameter or width, respectively. The model takes lateral heat flows into account as well as thermal losses. Figure 1 shows the temperature increase of a pulsed thermography measurement at three different locations on the sample. The numerical model is fitted to the experimental data (red lines) to quantify the groove. The numerical simulation matches the experimental data well.
Other than commonly assumed the relaxation times observed in the electrical low-frequency range (1 mHz – 40 kHz) of natural porous media like sandstones and tuff stones cannot be directly related to the dominant (modal) pore throat sizes, measured (e.g.) with mercury intrusion porosimetry (MIP). Working with a great variety of sandstones from very different origins and featuring great variations in textural and chemical compositions as well as in geometrical pore space properties, we observed that particularly samples with narrow pore throats were characterized by long (low-frequency) relaxations. These, however, can (following the current theories) be rather explained by long “characteristic length scales” in these media or low diffusion coefficients along the electrical double layer. However, there is no straightforward way (or single approved method) of getting reliable numbers for properties such as the lengths of pore throats, the diameter and length of the wide pores and their respective distributions. Consequently we follow a multi-methodical approach and combine the benefits of MIP, micro-computed tomography (µ-CT) and nuclear magnetic resonance (NMR) to achieve much deeper insight due to the different resolutions and sensitivities to either pore constrictions (throats) or wide pores. This helps us to understand, whether the observed electrical relaxation phenomena actually depend on geometric length scales or rather on other properties such as chemical composition, clay content, clay type or cation exchange capacity. Our poster showcases selected results of a systematic study on texturally and petrophysically very different sandstones.
Thermographic NDE is based on the interaction of thermal waves with inhomogeneities. These inhomogeneities are related to sample geometry or material composition. Although thermography is suitable for a wide range of inhomogeneities and materials, the fundamental limitation is the diffusive nature of thermal waves and the need to measure their effect radiometrically at the sample surface only. The propagation of the thermal waves from the heat source to the inhomogeneity and to the detection surface results in a degradation in the spatial resolution of the technique. A new concerted ansatz based on a spatially structured heating and a joint sparsity of the signal ensemble allows an improved reconstruction of inhomogeneities. As a first step to establish an improved thermographic NDE method, an experimental setup was built based on structured 1D illumination using a flash lamp behind a mechanical aperture. As a follow-up to this approach, we now use direct structured illumination using a 1D laser array. The individual emitter cells are driven by a random binary pattern and additionally shifted by fractions of the cell period. The repeated measurement of these different configurations with simultaneously constant inhomogeneity allows for a reconstruction that makes use of joint sparsity. With analytical-numerical modelling or numerical FEM simulations, we study the influence of the parameters on the result of non-linear reconstruction. For example, the influence of the illumination pattern as a variable heat flux density and Neumann boundary condition for convolution with the constant Green's function can be studied. These studies can be used to derive optimal conditions for a measurement technique.
Optical lock-in thermography is a completely contactless and very sensitive NDE technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive, do not need any work safety measures and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Altogether using lasers considerably increases the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in testing [1, 2]. We report on the mentioned benefits of using such high-power lasers and analyze the range of materials to be tested using lock-in thermography in dependence on the laser irradiance, the modulation frequency, the infrared camera as well as the optical and thermal material parameters. In this context, we also address a number of systematic errors caused by the use of ideal and non-ideal heat sources. For example, the measured phase angle in lock-in thermography depends on the irradiance and the modulation bandwidth of the source. This in turn has a decisive influence on the uncertainty in the quantification of, e.g. layer thicknesses.
19th and 20th centuries glass paint layers consist of a colour body and a colourless lead silicate flux, in which borax or boric acid was added as further component to improve the paint ability and to reduce the firing temperature for multiple layers of paint. Model glasses were used in laboratory tests to investigate the stability of glass paints with additions of boron oxide. To determine boron in paint layers, a LIBS-system with pulsed NdYAG-laser was used.
Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or hardly accessible areas. A challenging task, however, is the generation of threedimensional distribution maps from these gas measurements.
Suitable reconstruction algorithms can be adapted, for instance, from the field of computed tomography (CT), but both their performance and strategies for selecting optimal measuring poses must be evaluated. For this purpose simulations are used, since, in contrast to field tests, they allow repeatable conditions. Although several simulation tools exist, they lack realistic models of remote gas sensors. Recently, we introduced a model for a Tunable Diode Laser Absorption Spectroscopy (TDLAS) gas sensor taking into account the conical shape of its laser beam. However, the novel model has not yet been validated with experiments. In this paper, we compare our model with a real sensor device and show that the assumptions made hold.
While sensors for monitoring the energy source, the melt pool size or temperatures during the process of metal-based Additive Manufacturing (AM) systems are commercially available, the impact of their results on the part quality are often unclear. In the BAM project ProMoAM, results of different process monitoring techniques are combined to achieve quality assurance for the produced parts during the build. Here, first results of simultaneous measurements of optical emission spectroscopy and thermography during the laser metal deposition process using 316L are presented.
EMPIR Project NanoXSpot
(2019)
The overall objective of project NanoXSpot (Nanometre X-ray Focal Spot Measurement) is to develop traceable measurement methods for determining the focal spot size, shape, and position of nanometre resolution X-ray tubes. The impact of the technical results will be ensured by preparing prenormative documents for submission to CEN TC 138 (Non-destructive testing) WG 1 (Radiographic testing), which directly addresses the research needs of CEN, currently revising standards in the series 12543 for focal spot measurements below 5 µm spot size to harmonise standards and measurement method between ASTM and CEN.
The separation of two closely located defects in fields of Thermographic NDE is very challenging. The diffusive nature of thermal waves leads to a fundamental limitation in spatial resolution. Therefore, super resolution image reconstruction can be used. A new concerted ansatz based on spatially structured heating and joint sparsity of the signal ensemble allows an improved reconstruction of closely located defects. This new technique has also been studied using 1D laser arrays in active thermography.
The post-processing can be roughly described by two steps: 1. Finding a sparse basis representation using a reconstruction algorithm such as the Fourier transform, 2. Application of an iterative joint sparsity (IJOSP) method to the firstly reconstructed data. For this reason, different methods in post-processing can be compared using the same measured data set.
The focus in this work was the variation of reconstruction algorithms in step 1 and its influence on the results from step 2. More precise, the measured thermal waves can be transformed to virtual (ultrasound) waves that can be processed by applying ultrasound reconstruction algorithms and finally the super resolution algorithm. Otherwise, it is also possible to make use of a Fourier transform with a subsequent super resolution routine. These super resolution thermographic image reconstruction techniques in post-processing are discussed and evaluated regarding performance, accuracy and repeatability.
The diffusive nature of heat propagation complicates the separation of two closely spaced defects. This results in a fundamental limitation in spatial resolution. Therefore, super resolution (SR) image reconstruction can be used. SR processing techniques based on spatially structured heating and joint sparsity of the signal ensemble allows for an improved reconstruction of closely spaced defects. This new technique has been studied using a 1D laser array with randomly chosen illumination pattern.
This paper presents the results after applying SR algorithms such as the iterative joint sparsity (IJOSP) algorithm, to our processed measurement data. Two different data processing strategies are evaluated and discussed regarding their influence on the reconstruction goodness as well as their complexity. Moreover, the degradation of the SR reconstruction by the choice of regularization parameters in data processing is discussed.
The application of both SR techniques that are evaluated in this paper results in a spatial resolution enhancement of approximately a factor of four which leads to a better separation of two closely spaced defects. The fundamental difference between both SR techniques is their complexity.
The separation of two closely located defects in fields of Thermographic NDE is very challenging. The diffusive nature of thermal waves leads to a fundamental limitation in spatial resolution. Therefore, super resolution image reconstruction can be used.
The measured thermal waves can be transformed to virtual (ultrasound) waves that can be processed by applying ultrasound reconstruction algorithms and finally the super resolution algorithm. Otherwise, it is also possible to make use of a Fourier transform with a subsequent super resolution routine.
These super resolution thermographic image reconstruction techniques in post-processing are discussed and evaluated regarding performance, accuracy and repeatability.
The knowledge of the cure situation during the production process of
thermosetting material is of enormous importance.
• Mid- and near- infrared (IR) spectroscopy in attenuated total
reflectance (ATR) geometry are promising techniques for curing
studies.
• An IR/THz sensor system was developed to investigate its suitability
for future online monitoring of curing processes in the production line.
Novel Technique for On-Line Monitoring of the Curing Process of Fiber Reinforced Polymer Composites
(2020)
A specially designed experimental set up has been integrated into a commercially available FT IR Spectrometer for ATR experiments on Epoxy Systems. Representative data of far infrared spectra measured during the curing process at different temperatures of an epoxy system will be presented in dependency of the curing situation. The experiments and the selected set up are discussed to demonstrate its potential for future monitoring and ageing control applications during a manufacturing process of polymer composites.
Etalon effects in THz transmittance spectra, either taken in time-domain or frequency-domain, often hamper or even hinder the interpretation of film properties. In this paper we discuss the transferability and applicability of spectroscopic methods usually employed in the near and mid infrared spectral range and exemplarily present the application field.
A joint project of partners from industry and research institutions for the research and construction of an analysis system for an automated, sensor-supported sorting of construction and demolition waste will be presented. This is intended to supplement or replace the previously practiced manual sorting, which harbors many risks and dangers for the staff and only enables obvious, visually detectable differences for separation. The method of laser-induced breakdown spectroscopy is to be used in combination with hyperspectral sensors. Due to the jointly processed information (data fusion), this should lead to a significant improvement in the separation of types. In addition to the sorting of different materials (concrete, main masonry building materials, organic components, glass, etc.), impurities such as SO3-containing building materials (gypsum, aerated concrete, etc.) could also be detected and separated.
The subsequent recycling and sales opportunities are examined, such as the use of recycled aggregates in concrete, the recycling of building materials containing sulphate as a gypsum substitute for the cement industry or the agglomeration of synthetic lightweight aggregates for lightweight concrete or as a substrate for green roofs. At the same time, it is investigated whether soluble components (sulfates, heavy metals, etc.) can be detected by LIBS without a wet chemical analysis and what impact the recycling materials have on the environment.
The entire value chain is examined using the example of the Berlin location in order to minimize economic / technological barriers and obstacles on a cluster level and to sustainably increase the recovery and recycling rates.
Photothermal characterization of polyester composites loaded with parallelly arranged graphite rods
(2022)
One of the biggest challenges in the measurement of thermal properties is to measure inhomogeneous materials This work focuses on measuring the thermal properties of cylindrical polyester resin composite materials loaded with graphite rods oriented in the direction of the resin thickness, varying the graphite concentrations starting from zero to 8 75 of volumetric fraction and changing the distribution of graphite rods inside the polyester matrix
Responsible treatment of the environment and resources is a key element of sustainability. The building and construction industry is one of the largest consumers of natural resources. Consequently, there is a particular need for regulations and technologies that help to create closed material cycles. From the technological point of view, such efforts are complicated by the growing material diversity and the amount of composites contained in present and future construction and demolition waste (CDW). Nowadays, simple but proven techniques like manual sorting are mainly used. However, this practice not only poses health risks and dangers to the staff performing the work, but also relies on merely obvious, visually striking differences. Automated, sensor-based sorting of these building materials could complement or replace this practice to improve processing speed, recycling rates, sorting quality, and prevailing health conditions. The preliminary results for the identification of a wide variety of building materials with LIBS are presented.
Thermographic non-destructive testing is based on the interaction of thermal waves with inhomogeneities. The propagation of thermal waves from the heat source to the inhomogeneity and to the detection surface according to the thermal diffusion equation leads to the fact that two closely spaced defects can be incorrectly detected as one defect in the measured thermogram. In order to break this spatial resolution limit (super resolution), the combination of spatially structured heating and numerical methods of compressed sensing can be used. The improvement of the spatial resolution for defect detection then depends in the classical sense directly on the number of measurements. Current practical implementations of this super resolution detection still suffer from long measurement times, since not only the achievable resolution depends on performing multiple measurements, but due to the use of single spot laser sources or laser arrays with low pixel count, also the scanning process itself is quite slow. With the application of most recent high-power digital micromirror device (DMD) based laser projector technology this issue can now be overcome.