Analytische Chemie
Filtern
Dokumenttyp
- Zeitschriftenartikel (611)
- Vortrag (487)
- Posterpräsentation (288)
- Sonstiges (29)
- Beitrag zu einem Tagungsband (20)
- Forschungsdatensatz (11)
- Dissertation (9)
- Buchkapitel (8)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (2)
- Forschungsbericht (2)
Sprache
- Englisch (1297)
- Deutsch (169)
- Mehrsprachig (5)
Schlagworte
- Fluorescence (165)
- Quantum yield (85)
- Dye (62)
- Nanoparticle (62)
- Lifetime (60)
- Sensor (58)
- Nano (57)
- Immunoassay (51)
- ICP-MS (49)
- Photophysics (49)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (1471) (entfernen)
Paper des Monats
- ja (14)
This is the first time that PE frits were used to quantify sulfur in copper and its alloys by isotope dilution combined with LA-ICP-MS: an alternative approach for sample preparation. The following properties of the PE frit meet the requirements for isotope dilution LA-ICPMS: porous material, thermo plastic (melting point >100°C), chemical resistance (nitric acid >70%) and high adsorption efficiency. The breakthrough, however, as a support material, especially when comparing the PE frit with other materials such gelatin or sodium silicate is the low blank, which is only two times of the gas flow blank (2.3-4.0 x 10⁴ cps). Additionally, the porosity of the frit was considered, as it directly affects the adsorption efficiency for the sample solution, which is present in the cavities of the frit.
Adsorption efficiency was studied by depositing sulfur standards with varying sulfur amounts (0, 2, 5, 10, 20, 40 and 80 µg S) on the frits. The remaining sulfur which was not absorbed by the frit was rinsed off and was measured by ICP-MS. This indirect method shows that more than 99.5 % of the loaded sulfur was absorbed by the frit. Such high absorption efficiency is completely sufficient for a support material to be used in LA-ICP-IDMS. The so prepared frits with increasing sulfur amount were measured by LA-ICP-MS showing a good linearity between 0 µg S and 40 µg S with a correlation coefficient r2 of 0.9987 and sensitivity of 3.4x10⁴ cps µgˉ¹ for 32S.
Three copper reference materials produced by BAM were selected to develop and validate the LA-ICP-IDMS procedure. The IDMS technique was applied to these samples as follows: the samples were spiked, dissolved, digested and then the digest was adsorbed on the frits.
Quantitative analysis of complex proteins is a challenging task in modern bioanalytical chemistry. Commonly available isotope labels are still suffering from limitations and drawbacks, whereas new metal labels open numerous possibilities in mass spectrometric analyses. In this work, we have developed a newmetal labeling strategy to tag glycan structures of proteins, more particularly antibodies. The oligosaccharide glycans were selectively trimmed to the last N-acetylglucosamine to which an artificial azide containing galactose residue was bound. This azide can be used for subsequent cycloaddition of an alkyne. Therefore, we developed a lanthanide-containing macrocyclic reagent to selectively connect to this azido galactose. In summary, the glycan structures of an antibody can be labeled with a metal functionality using this approach. Furthermore, the functionality of the antibodies can be fully maintained by labeling the Fc glycans instead of using labeling reagents that target amino or thiol groups. This approach enables the possibility of using elemental, besides molecular mass spectrometry, for quantitative analyses or imaging experiments of antibodies in complex biological samples.
We designed and synthesized triphenylamine based and coumarin fused rhodamine hybrid dyes and characterized using 1H, 13C NMR and HR-LCMS analysis. Both the newly synthesized hybrid dyes were found to show red shifted absorption as well as emissions and large Stokes shift (40e68 nm) as compared to the small Stokes shift (25e30 nm) of reported dyes Rhodamine B and 101. Photophysical properties of these dyes were studied in different solvents and according to the solvents acidity or basicity they preferred to remain in their spirocyclic or open form in different ratio. We studied the spirocyclic as well as open form derivatives of these dyes for their viscosity sensitivity in three different mixture of solvents i.e. polar-protic [EtOH-PEG 400], polar-aprotic [toluene-PEG 400] and non-polaraprotic [toluene-paraffin]. They are found to show very high viscosity sensitivity in polar-protic mixture of solvents [EtOH-PEG 400] and hence concluded that both polarity as well as viscosity factor worked together for the higher emission enhancement rather than only viscosity factor. As these dyes showed very high viscosity sensitivity in their spirocyclic as well as open form, they can be utilized as viscosity sensors in visible as well as deep red region. We also correlated our experimental finding theoretically by using Density Functional theory computations.
A frequently studied environmental contaminant is the active substance diclofenac, which is removed insufficiently in sewage treatment plants. Since its inclusion in the watch list of the EU Water Framework Directive, the concentrations in surface waters will be determined throughout Europe. For this, still, more precise analytical methods are needed. As a reference, HPLC-MS is frequently employed. One of the major metabolites is 4’-hydroxydiclofenac (4’-OH-DCF). Also, diclofenac lactam is important for assessing degradation and transformation. Aceclofenac (ACF), the glycolic acid ester of diclofenac is used as a drug, too, and could potentially be cleaved to yield diclofenac again. In various sewage treatment plant influent samples, diclofenac, 4’-OH-DCF, DCF lactam and ACF could be determined with detection limits of 3 µg/L, 0.2 µg/L, 0.17 µg/L and 10 ng/L, respectively.
The overall interest in nanotoxicity, triggered by the increasing use of nanomaterials in the material and life sciences, and the synthesis of an ever increasing number of new functional nanoparticles calls for standardized test procedures1,2 and for efficient approaches to screen the potential genotoxicity of these materials. Aiming at the development of fast and easy to use, automated microscopic methods for the determination of the genotoxicity of different types of nanoparticles, we assess the potential of the fluorometric γH2AX assay for this purpose. This assay, which can be run on an automated microscopic detection system, relies on the detection of DNA double strand breaks as a sign for genotoxicity3. Here, we provide first results obtained with broadly used nanomaterials like CdSe/CdS and InP/ZnS quantum dots as well as iron oxide, gold, and polymer particles of different surface chemistry with previously tested colloidal stability and different cell lines like Hep-2 and 8E11 cells, which reveal a dependence of the genotoxicity on the chemical composition as well as the surface chemistry of these nanomaterials. These studies will be also used to establish nanomaterials as positive and negative genotoxicity controls or standards for assay performance validation for users of this fluorometric genotoxicity assay. In the future, after proper validation, this microscopic platform technology will be expanded to other typical toxicity assays.
Fuel contamination of soils display complex and variable hydrocarbon mixtures with different volatility and toxicity characteristics. A recently suggested headspace procedure for the structure-based quantification of volatile hydrocarbons is evaluated regarding repeatability, reproducibility, and practical robustness. Three aliphatic and three aromatic fractions covering the boiling range between 69 and 216°C were defined as summation parameters by their respective equivalent carbon number ranges. A standard mixture of 35 aliphatic and aromatic hydrocarbons was used for calibration on basis of selected mass fragments specific for the aliphatics and aromatics, respectively. Two standard soils were fortified with the standard mixture or different fuels, respectively, and submitted to the analytical procedure. Limit of detection (LOD) and limit of quantification (LOQ) were for all fractions lower than 0.1 and 0.3 mg/kg, respectively. Analyte recovery was linear up to between 20 and 110 mg hydrocarbons/kg soil depending on the fraction. Hydrocarbon recovery ranged between 80% and 110% depending on the fraction and the repeatability was typically better than 10%. Finally, the impact of extraction solvent variation, column solid-phase polarity, and alternative summation of fractions were investigated. The procedure was applied to liner samples taken from a site contaminated with aviation fuel and its practicability is discussed.
Der kürzlich publizierte Chrom(III)-Komplex 13+([Cr(ddpd)2]3+) zeigt in wässriger Lösung unter Umgebungsbedingungen eine bemerkenswert starke Emission im nahen Infrarot-Bereich mit einer Emissionswellenlänge von 775 nm.
Geschicktes Ligandendesign verhindert strahlungslose Desaktivierungsprozesse wie Photosubstitution, Rück-Intersystem-Crossing und trigonale Verzerrungen und führt damit zu einer Phosphoreszenzlebensdauer im Bereich von Mikrosekunden.
In Abwesenheit von Energieakzeptoren wie molekularem Sauerstoff verbleibt nur Energietransfer zu hochenergetischen Oszillatoren der Liganden und Lösungsmittelmoleküle wie beispielsweise OH- und CH-Streckschwingungen als Desaktivierungspfad. Selektive Deuterierung der ddpd-Liganden und der Lösungsmittel l-sst die Effizienz dieser Oszillatoren bei der Desaktivierung angeregter Zustände erkennbar werden. Gezieltes Ausschalten dieser Relaxationspfade führt zu einer Quantenausbeute von 30% und einer Lebensdauer von 2.3 Millisekunden bei Raumtemperatur in Lösung – Rekordwerte für einen Komplex, der auf dem Element Chrom basiert. Diese fundamentalen Erkenntnisse ebnen den Weg für gezieltes Ligandendesign zur Synthese lumineszierender Komplexe mit gut verfügbaren Übergangsmetallen.
The recently reported luminescent chromium(III) complex 13+ ([Cr(ddpd)2]3+; ddpd=N,N’-dimethyl-N,N’-dipyridine-2-yl-pyridine-2,6-diamine) shows exceptionally strong near-IR emission at 775 nm in water under ambient conditions (F=11%) with a microsecond lifetime as the ligand design in 13+ effectively eliminates non-radiative decay pathways, such as photosubstitution, back-intersystem crossing, and trigonal twists. In the absence of energy acceptors, such as dioxygen, the remaining decay pathways are energy transfer to high energy solvent and ligand oscillators, namely OH and CH stretching vibrations. Selective deuteration of the solvents and the ddpd ligands probes the efficiency of these oscillators in the excited state deactivation. Addressing these energytransfer pathways in the first and second coordination sphere furnishes a record 30% quantum yield and a 2.3 millisecond lifetime for a metal complex with an earth-abundant metal ion in solution at room temperature.
Several works evaluated the toxicity of pharmaceutical drugs and climate related changes in invertebrates but few explored the combined effects of both stressors, namely considering their mode of action (MoA). Carbamazepine (CBZ) and cetirizine (CTZ) are pharmaceutical drugs detected in the environment and the toxicity derived from the combined effects of these drugs with ocean acidification (OA) is poorly explored. Thus, the present study investigated the biochemical parameters related to an oxidative stress response and the transcription of genes related to the MoA of CBZ (1.0 mg/L) and CTZ (0.6 mg/L) in the clam Ruditapes philippinarum chronically exposed (28 days) to control (7.8) and low (7.5) pH conditions. The results obtained showed that despite the clams accumulated both drugs, at low pH the clams exposed to CTZ decreased drug concentration and BCF values (CTZ uptake: 2.0 ± 0.5 ng/g fresh weight; BCF: 3.8 ± 0.9) in comparison with clams exposed to control pH (CTZ uptake: 2.9 ± 0.3 ng/g fresh weight; BCF: 5.5 ± 0.6). No oxidative stress was induced by the exposure to CBZ or CTZ at each pH level, but the transcription of several genes related with the MoA (neurotransmission, immunity and biomineralization) was altered by low pH, drug exposure and the combination of both stressors. At both pH conditions, CBZ increased the transcription of GABA receptor gene (neurotransmission) and CTZ led to a decrease of Perlucin gene (biomineralization) transcription. The transcription of MyD88 gene (immunity) decreased at low pH (7.5) combined with drug exposure (CBZ or CTZ). Thus, it was highlighted that the interaction of drug exposure and low pH conditions can change bivalves’ sensitivity to drugs or alter drugs toxicity.
Equipping ZIF particles with a polyelectrolyte membrane provides functional groups at their interface, enabling further conjugations necessary for applications such as targeted drug delivery. Previous approaches to coat ZIF particles with polyelectrolytes led to surface corrosion of the template material. This work overcomes previous limitations by performing a Layer-by-Layer (LbL) polyelectrolyte coating onto ZIF-8 and ZIF-67 particles in nonaqueous environment. Using the 2-methylimidazolium salt of polystyrensulfonic acid instead of the acid itself and polyethyleneimine in methanol led to intact ZIF particles after polyelectrolyte coating. This was verified by electron microscopy. Further, zetapotential and atomic force microscopy measurements confirmed a continuous polyelectrolyte multilayer built up. The here reported adaption to the well-studied (LbL) polyelectrolyte selfassembly process provides a facile method to equip ZIF particles with a nanometer thin polyelectrolyte multilayer membrane.
Nano- and microparticles are of increasing importance for a wide range of applications in the material and life sciences. Examples are their use as carriers for dye molecules and drugs, multichromophoric reporters for signal enhancement strategies in optical assays, targeted probes for bioimaging, and biosensors. All these applications require surface functionalization of the particles with e.g., ligands (to tune the dispersibility and prevent unspecific interactions), crosslinkers, sensor dyes, or analyte recognition moieties like biomolecules, and subsequently, the knowledge of the chemical nature and total number of surface groups as well as the number of groups accessible for coupling reactions. Particularly attractive for the latter are sensitive and fast photometric or fluorometric assays, which can be read out with simple, inexpensive instrumentation. Here, we present a novel family of cleavable photometric and multimodal reporters for the quantification of conjugatable amino and carboxyl surface groups on nano- and microparticles. These probes allow for the determination of particle-bound labels, unbound reporters in the supernatant, and reporters cleaved off from the particle surface as well as the remaining thiol groups on the particles by photometry and inductively coupled optical emission spectrometry (32S ICP-OES).3 Comparison of the performance of these cleavable reporters with conventional labels, utilizing changes in intensity and/or colour of absorption and/or emission, underlines the analytical potential of this versatile concept which elegantly circumvents signal distortions by light scattering and encoding dyes, and enables straightforward validation by method comparison.
Cost-effective water cleaning approaches using improved Treatment technologies, for instance based on catalytic processes with high activity catalysts, are urgently needed. The aim of our study was to synthesize efficient Fenton-like photo-catalysts for rapid degradation of persistent organic micropollutants in aqueous medium. Iron-based nanomaterials were chemically synthesized through simple procedures by immobilization of either iron(II) oxalate (FeO) or iron(III) citrate (FeC) on magnetite (M) nanoparticles stabilized with polyethylene glycol (PEG). Various investigation techniques were performed in order to characterize the freshly prepared catalysts. By applying advanced oxidation processes, the effect of catalyst dosage, hydrogen peroxide concentration and UV-A light exposure were examined for Bisphenol A (BPA) conversion, at laboratory scale, in mild conditions. The obtained results revealed that BPA degradation was rapidly enhanced in the presence of low-concentration H2O2, as well as under UV-A light, and is highly dependent on the surface characteristics of the catalyst. Complete photo-degradation of BPA was achieved over the M/PEG/FeO catalyst in less than 15 minutes. Based on the catalytic performance, a hierarchy of the tested catalysts was established: M/PEG/FeO > M/PEG/FeC > M/PEG. The results of cytotoxicity assay using MCF-7 cells indicated that the aqueous samples after treatment are less cytotoxic.
Many applications of nanometer- and micrometer-sized particles include their surface functionalization with linkers, sensor molecules, and analyte recognition moieties like (bio)ligands. This requires knowledge of the chemical nature and number of surface groups accessible for subsequent coupling reactions. Particularly attractive for the quantification of these groups are spectrophotometric and fluorometric assays, which can be read out with simple instrumentation. In this respect, we present here a novel Family of cleavable spectrophotometric and multimodal reporters for conjugatable amino and carboxyl surface groups on nano- and microparticles. This allows determination of particle-bound labels, unbound reporters in the supernatant, and reporters cleaved off from the particle surface, as well as the remaining thiol groups on particle, by spectrophotometry and inductively coupled optical emission spectrometry (32S ICP-OES). Comparison of the performance of these cleavable reporters with conductometry and conventional labels, utilizing changes in intensity or Color of absorption or emission, underlines the analytical potential of this versatile concept which elegantly circumvents Signal distortions by scattering and Encoding dyes and enables straightforward validation by method comparison.
Polymeric nanoparticles (NP) are of increasing importance for a wide range of applications in the material and life sciences, including their use as drug carriers, fluorescent sensors and multimodal reporters in a large variety of bioassays and bioimaging studies. Application-relevant properties of NP include their size (and size distribution), shape, optical properties, and ease of subsequent functionalization, e.g. with linkers, sensor molecules, and bioligands. In this respect, knowledge of the chemical nature, the total number of surface groups and the number of groups accessible for subsequent coupling reactions is mandatory.1 Commercially available polystyrene NP often contain different additives like stabilizers, radical starters and crosslinkers, which can influence the quantification of surface functionalities. Moreover, they often have unknown surface group densities that may vary from batch to batch, which complicates or even hampers their reliable use in many (bio)applications. To circumvent these issues, we synthesized amino- and carboxy-functionalized, monodisperse 100 nm polystyrene NP with three different, well-defined surface group densities. Using a recently developed approach for the quantification of functional groups on nano- and microparticles with cleavable reporters,2 we quantified the assessible functional groups on the self-synthesised PS particles via optical spectroscopy (photometry) and inductively coupled optical emission spectrometry (32S ICP-OES). In addition, we developed a fluorimetric approach for the quantification of surface functional groups on nanoparticles based on the labelling with luminescent lanthanide complexes (LLC). In contrast to common organic dyes, LLC are not prone to photo¬luminescence quenching arising from reabsorption or dye aggregation, and thus, enable a reliable fluorometric quantification of the assessible functional groups on NP surfaces. Moreover, lanthanide tags can be detected with high specificity and sensitivity with analytical techniques such as XPS and ICP-MS, which allow for the multimodal validation of the fluorometric quantification approach.
Solid state multi-band emitters like lanthanide doped up-conversion nanoparticles (UCNPs) are promising materials for energy and biotechnologies. These materials are excitable in the near infrared (NIR) and show emission bands from UV to SWIR with excellent photostability, and long luminescence lifetimes in the µs range. The efficiency of these materials, i.e. the multiphoton absorption processes, the excitation power dependent population, and deactivation dynamics are strongly influenced by the particle size, structure, doping concentration, surface chemistry, and microenvironment. For applications UCNPs have to be optimized to meet the application relevant optical properties like the upconversion quantum yield (UC) and downshifting quantum yield (PL), luminescence lifetime and emission spectra.
We investigated ß-NaYF4 NPs co-doped with Yb3+ and Er3+ in aqueous and organic media and as powder. For the later, bulk and nanomaterial is compared. For dispersed particles the influence of surface chemistry (ligands), microenvironment (solvent) and size (10 to 43 nm) was studied. Especially for bioapplications the Förster-Resonance-Energy-Transfer (FRET) efficiency from UCNPs to organic dye molecules (rose bengal and sulforhodamine B) was optimized with respect to the UCNP size.
We found cascade IR generation in Al laser induced plasma. This generation includes doublet transitions 3s25s 2S1∕2→ 3s24p 2P1∕2,3∕2 → 3s24s 2S1∕2; corresponding to strong lines at 2110 and 2117 nm, and much weaker lines at 1312–1315 nm. The 3s25s2S 1∕2 starting IR generation level is directly pumped from the 3s23p 2P3∕2 ground level. The starting level for UV generation at 396.2 nm (transitions 3s24s 2S1∕2 → 4p 2P3∕2) is populated due to the fast collisional processes in the plasma plume. These differences led to different time and special dependences on the lasing in the IR and UV spectral range within the aluminum laser induced plasma.
Non-invasive Cereal Analysis by GC-MS detection of Trichodiene as a Volatile Mycotoxin Biomarker
(2018)
Due to the increasing consumption of cereals worldwide, the monitoring of growth, storage and processing is becoming more and more crucial. Particularly when stored, infested grains breed fungal clusters (“hot spots”) in which mycotoxins greatly exceed allowed maximum levels. Because of their unpredictable presence, current sample drawing and procedures for mycotoxin analysis represent a complex challenge for operators, involving invasive and cost intensive steps.
Therefore, new time- and labour-saving mycotoxin control methods including sampling and analysis steps are needed. A possible approach is the non-invasive analysis of the homogeneous gas phase above the crops, instead of analyzing random samples. However, this procedure requires microbial volatile organic compounds (MVOC´s) being released by the samples and representing the present mycotoxins. Previous investigations revealed trichodiene to be a precursor in trichothecenes biosynthesis – one of the largest mycotoxin groups with over 180 compounds. Due to its non-functionalized sesquiterpene structure, trichodiene has already been quantified using Headspace GC-MS methods (for instance]). Thereby, it can possibly be used as a biomarker for trichothecene contamination in foodstuff.
However, further investigations are necessary. The correlation between trichodiene concentration in the gas phase and trichothecenes mass fraction in the sample must be examined closely to draw conclusions about the exact trichothecene content within samples. Realizing this idea, would widely extend the applicability of trichodiene and enormously simplify trichothecene quantification. Hence, this first step of an ongoing study aims to develop a laboratory reference method using trichodiene as volatile biomarker to quantify trichothecenes in cereals. Static headspace and SPME-enrichment coupled to gas chromatography with mass spectrometry (GC-MS) were employed. In a second step, this reference method is intended to validate new approaches for fast on-site screening of trichodiene in cereals.
Non-invasive Cereal Analysis by GC-MS detection of Trichodiene as a Volatile Mycotoxin Biomarker
(2018)
Due to the increasing consumption of cereals worldwide, the monitoring of growth, storage and processing is becoming more and more crucial. Particularly when stored, infested grains breed fungal clusters (“hot spots”) in which mycotoxins greatly exceed allowed maximum levels. Because of their unpredictable presence, current sample drawing and procedures for mycotoxin analysis represent a complex challenge for operators, involving invasive and cost intensive steps.
Therefore, new time- and labour-saving mycotoxin control methods including sampling and analysis steps are needed. A possible approach is the non-invasive analysis of the homogeneous gas phase above the crops, instead of analyzing random samples. However, this procedure requires microbial volatile organic compounds (MVOC´s) being released by the samples and representing the present mycotoxins. Previous investigations revealed trichodiene to be a precursor in trichothecenes biosynthesis – one of the largest mycotoxin groups with over 180 compounds. Due to its non-functionalized sesquiterpene structure, trichodiene has already been quantified using Headspace GC-MS methods (for instance). Thereby, it can possibly be used as a biomarker for trichothecene contamination in foodstuff.
However, further investigations are necessary. The correlation between trichodiene concentration in the gas phase and trichothecenes mass fraction in the sample must be examined closely to draw conclusions about the exact trichothecene content within samples. Realizing this idea, would widely extend the applicability of trichodiene and enormously simplify trichothecene quantification. Hence, this first step of an ongoing study aims to develop a laboratory reference method using trichodiene as volatile biomarker to quantify trichothecenes in cereals. Static headspace and SPME-enrichment coupled to gas chromatography with mass spectrometry (GC-MS) were employed. In a second step, this reference method is intended to validate new approaches for fast on-site screening of trichodiene in cereals.
Zearalenone (ZEN) and its sulfate and glucoside conjugates have been detected in (a broad variety of) food and feed commodities1. Both conjugated derivatives are formed as part of fungal or plant secondary metabolism and thus, belong to the group of modified mycotoxins2. After consumption of contaminated foodstuff, the conjugates can be hydrolyzed by human intestinal microbiota leading to liberation of ZEN that implies an underestimation of the true ZEN exposure. In order to include ZEN conjugates in routine analysis, as well as for toxicological investigation reliable standards are needed.
The objective of the present study was to develop a simple and economic method for biosynthesis of ZEN conjugates. Preceding experiments on the biotransformation of ZEN by Rhizopus and Aspergillus species showed a mixed metabolite formation3. Therefore, these known ZEN conjugating fungal strains were screened for their potential to selectively synthesize the ZEN derivatives ZEN-14-sulfate (Z14S), ZEN-14-glucoside (Z14G) and ZEN-16-glucoside (Z16G). The screening was conducted by adding ZEN to liquid fungal cultures. Cultivation conditions and ZEN incubation time were varied. All media samples were analyzed for metabolite formation by HPLC-MS/MS. Z14S was exclusively formed by A. oryzae. Under optimized conditions a specific biosynthesis of Z14G by R. oryzae and Z16G by R. oligosporus was achieved. After liquid-liquid-extraction and preparative chromatographic cleanup 1H-NMR purities of ≥ 73% for Z14S, ≥ 82% for Z14G and ≥ 50% for Z16G were obtained. In addition, a consecutive biosynthesis was developed by first using Fusarium graminearum for ZEN biosynthesis on rice based liquid medium. After inactivation of Fusarium the subsequent conjugation reaction was conducted utilizing Aspergillus and Rhizopus species under the various optimized conditions.
In this study an easy and cost-efficient biosynthesis for Z14S, Z14G and Z16G was developed. The developed biosynthesis could be also used for other metabolites like ZEL conjugates. Our results of the in vitro screening indicate also the formation of a ZEL-glucoside and α ZEL-sulfate as major metabolites by R. oryzae. In sum, under optimized cultivation conditions fungi can be easily utilized for a targeted and stereospecific synthesis of ZEN conjugates.
This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, microreactions, pump and probe diagnostics, tomography, temporal and spatial resolution. Basis of plasma computer modeling will be presented.
Laser induced plasma (LIP) is a dynamic, short living event which presents significant difficulty for modeling. In this report, a collisional-dominated chemical model developed earlier* is expanded by the inclusion of a new method for calculation of chemical reactions. The model consists of the coupled Navier-Stokes, state, radiative transfer, material transport, and chemical equations. The latter are written in terms of atomic and molecular partition functions rather than reaction rates. Typically, a solution of such the system of chemical equations is difficult for the entire range of plasma temperatures and densities because reaction constants may vary by hundreds orders of magnitude owing to extreme plasma conditions. No numerical solver of non-linear systems of equations handles this situation with ease. We resolve the problem by using a hierarchical approach. First, we rank the reactions according to their ascendancy. Second, we exploit either the contraction or Newton-Raphson algorithms to solve the system of chemical equations. We illustrate the approach by performing a series of calculations for reacting species Si, C, N, Ca, Cl and their molecules in laser induced plasmas.
Monitoring water quality regarding emerging pollutants, such as drug residues, demands for selective, high-throughput and multi-target analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affinity and specificity of target recognition by antibodies. Batch-wise processing in microtiter plates allows for the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex Suspension Array Fluorescence Immunoassay (SAFIA), which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core silica-shell microparticles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica shell creates a solid-support for the immunoassay: the target analytes, three drugs, carbamazepine, diclofenac and caffeine, and the fecal marker isolithocholic acid are covalently coupled to amino groups on the surface via NHS chemistry. Specific recognition of these haptens is accomplished by further introduction of PEG moieties, suppressing non-specific binding. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure, eliminating the demand for laborious washing steps and decreasing time-to-result. An automated flow cytometer is used for simultaneous decoding and quantification.
After optimization, the SAFIA showed limits of detection for all analytes in the low µg L 1 range, meeting the sensitivity criteria for wastewater analysis. Then, applicability of the SAFIA was studied on real wastewater samples from three different wastewater treatment plants in Berlin. The results were in good comparability to LC-MS/MS indicating high matrix stability. Moreover, the accuracy of the assay exceeded that of the respective ELISA. Finally, we used SAFIA to assess the influent of treated and untreated wastewater on the Douro river estuary in Portugal. The obtained results of the analysis were comparable to ELISA. However, the measurements by SAFIA could be carried out in one quarter the time of analysis required for ELISA.
Acknowledgements: The authors acknowledge financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16, DAAD Zuwendungsvertrag 57212899).
The improvement of immunoanalytical methods for the determination of pharmaceuticals in wastewaters is a crucial yet challenging endeavor. In this work, the development of an automated miniaturized ELISA based on micro-Bead Injection Spectroscopy (μ-BIS) [1] for the determination of carbamazepine, a widely employed anti-epileptic drug and emergent pollutant [2], was pursued.
The experimental workflow comprised the offline functionalization of Sepharose beads with specific anti-CBZ antibodies via affinity immobilization using protein G, and 3 online steps inside the microfluidic analyzer lab-on-valve (LOV): I) packing of the bead column into the detection unit; II) sequential percolation of sample and a CBZ competitor- labeled with horseradish peroxidase (tracer) through the bead column; and III) on-column colorimetric detection employing the enzyme substrate 3,3’,5,5’-tetramethylbenzidine. After each analysis, the bead column was discarded, and the flow cell was washed before receiving new beads.
The elimination of manual washing steps is a novel feature compared to batch-wise ELISA, making the method less error-prone and therefore more robust. The replacement of the solid support prevents memory effects and cross-contamination between runs. The use of microparticles as solid support for the molecular recognition elements accounts for high area-to-volume ratios, and low molecular diffusion distances. For that reason, time-to-result was reduced from several hours to less than 10 min. The consumption of reagents was also very low. For instance, only ca. 200 μg of solid support and 900 ng of anti-CBZ antibody were required per determination. At last, the versatility of the LOV platform offers the possibility of adapting the assay to other relevant pharmaceuticals and anthropogenic markers in water.
Acknowledgements: Inês I. Ramos thanks FCT (Fundação para a Ciência e a Tecnologia) and POPH (Programa Operacional Potencial Humano) for her grant (SFRH/BD/97540/2013). This work received financial support from the European Union (FEDER funds POCI/01/0145/FEDER/007265) and National Funds (FCT/MEC - Ministério da Educação e Ciência) under the Partnership Agreement PT2020 UID/QUI/50006/2013. Financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16) is also acknowledged.
[1] Gutzman, Y.; Carrol, A. D. Analyst 2006, 131, 809.
[2] Murray, K. E.; Thomas, S. M.; Bodour, A. A. Environ. Pollut. 2010, 158, 3462.
Imaging of elemental distributions in single cell assays as well as tissue sections can be performed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). This powerful technique offers precise spatially resolved measurements at the trace and ultratrace level and has been established as an excellent tool to answer analytical, biological and biomedical questions. To date, imaging mass cytometry is already able to simultaneously detect up to 40 cellular targets due to conjugation of isotopically pure lanthanides to affinity binders, e.g. antibodies.
To further enhance the ability of multiparametric analysis to more than 100 analytes at once, we investigated lanthanide nanocrystals as new, highly sensitive metal tags for identification of targets in clinical cell assays and tissue samples. Multiparametric analysis will be possible by encoding the lanthanide composition of nanocrystals associated to the affinity binders. Nanocrystals showed remarkable potential for sensitive detection in MS due to high stability and signal amplification compared to e.g. polymer tags, carrying fewer metal atoms.
Synthesis of functionalized lanthanide nanocrystals for further bioconjugation was performed with high reproducibility and monodisperse size distribution. For proof of principle, the uptake and distribution of these nanocrystals within the monolayered cell line A549 were investigated by mapping the intensities at subcellular resolution using LA-ICP-MS. It could be shown, that the cells were efficiently labeled with the nanocrystals and mostly accumulate near the nucleus. Additionally, the bioconjugation of the nanocrystals to antibodies and particularly the preservation of the antibody specificity was investigated using Dot Blot experiments. All in all, the results imply high sensitivity and the possibility of multiparametric analysis by doting various lanthanides into the nanocrystals.
The fundamental properties of a polymeric material are ultimately governed by its structure, which mainly relies on monomercomposition and connection, topology, chain length, and polydispersity. Thus far, these structural characteristics are typicallyset ex situ by the specific polymerization procedure, eventually limiting the future design space for the creation of moresophisticated polymers. Herein, we report on a single photoswitchable catalyst system, which enables in situ remote controlover the ring-opening polymerization of l-lactide and further allows regulation of the incorporation of trimethylene carbonateand δ -valerolactone monomers in copolymerizations. By implementing a phenol moiety into a diarylethene-type structure,we exploit light-induced keto–enol tautomerism to switch the hydrogen-bonding-mediated monomer activation reversiblyON and OFF. This general and versatile principle allows for exquisite external modulation of ground-state catalysis of a livingpolymerization process in a closed system by ultraviolet and visible light and should thereby facilitate the generation of newpolymer structures.
Due to their toxicity and widespread application for mining and industrial purposes, cyanides are ranking among the most important inorganic pollutants which should be tested and monitored not only in the aquatic environment, but also in soils and soil-like materials. Reference materials of soils with relevant contents of cyanide to ensure reliable test results of laboratories are rare today.
New certified reference material (CRM) BAM-U116/CGL306 “Cyanide in soil” was produced within a framework of cooperation between Central Geological Laboratory (CGL) of Mongolia and Federal Institute for Materials Research and Testing (BAM) of Germany in 2013-2017.
The CRM BAM-U116/CGL306 represents a mixture of a sandy soil collected from a contaminated former gasworks area in the Berlin region (Germany) and an unpolluted sandy soil from Nalaikh region (Mongolia). The bulk candidate material for this reference material was prepared at CGL CRM Laboratory exclusively destined to the preparation of reference materials and equipped with modern technical equipment. Homogeneity, stability and shelf life were studied in full compliance with ISO Guide 35. The CRM was evaluated as sufficiently homogeneous. Statistical evaluation of certification analysis was performed using software packages SoftCRM and ProLab Plus. Certified value of total cyanide of the CRM is 12.0 mg/kg and expanded uncertainty was assigned as 0.8 mg/kg.
The intended purpose of this material is the verification of analytical results obtained for the mass fraction of total cyanide in soils and soil-like materials applying the standardized procedure ISO 11262:2011. As any reference material, it can also be used for routine performance checks (quality control charts) or validation studies.
Cancer is a leading cause of death worldwide, and its early detection and resultant treatment contributes significantly to patient recovery and survival. Detection is currently based on magnetic resonance imaging and computed tomography, methods that are expensive, while processing of the results is time consuming. There is a need for low-cost cancer-detection techniques that give conclusive results in the shortest time possible. Molecularly imprinted polymers (MIPs) targeting tumor markers on cancerous cells may provide a cheaper solution for cancer detection. Thin MIP layers immobilized on particle platforms are known to give faster response times and increased selectivity in comparison to bulk MIPs. It has been reported that a fluorescent monomer can be incorporated into the MIP layer, allowing for faster detection of the target group, thus significantly shortening the turn-around time for biopsies.
Changes in sialylation patterns of cell surface glycoproteins indicate malignancy. Here, we present the development of MIPs that target sialic acid-terminated glycoproteins (SA MIPs), prepared as a thin layer on a silica nanoparticle platform. A fluorescent monomer is incorporated into the MIP layer, and upon binding of the target group to the specific binding pockets in the MIP, the fluorescence signal is enhanced. Transmission electron microscopy (TEM) and scanning electron microscopy (SEM) are used for structural characterization. To validate the specificity, fluorescence changes of MIPs in the presence and absence of template are compared to their corresponding non-imprinted polymer particles (NIP). Initial binding experiments with tumor cells using fluorescence microscopy demonstrate that the presented technique shows promise as a cheaper alternative to current detection methods, while allowing for relatively shorter analysis of biopsy results.
Accuracy of calibration-free (CF) methods in laser-induced breakdown spectroscopy (LIBS) depends on experimental conditions and instrumental parameters that must match a CF LIBS model. Here, the numerical study is performed to investigate effects of various factors, such as the optical density, plasma uniformity, line overlap, noise, spectral resolution, electron density and path length on the results of CF-LIBS analyses. The effects are examined one-by-one using synthetic spectra of steel slag samples that fully comply with the mathematical model of the method. Also, the algorithm includes several new features in comparison with previously proposed CF algorithms. In particular, it removes limits on the optical thickness of spectral lines that are used for the construction of the Saha-Boltzmann plot; it retrieves the absorption path length (Plasma diameter) directly from spectral lines; it uses the more realistic Voigt line profile function instead of the Lorentzian function; and it employs the pre-calculated and tabulated thin-to-thick line ratios instead of approximating functions for selfabsorption correction.
An improved algorithm for calibration-free laser induced breakdown spectroscopy (CF LIBS) is presented which includes several novel features in comparison with previously proposed similar algorithms. In particular, it allows using spectral lines with arbitrary optical thickness for the construction of Saha-Boltzmann plots, retrieves the absorption path length (plasma diameter) directly from a spectrum, replaces the Lorentzian line profile function by the Voigt function, and allows for self-absorption correction using pre-calculated and tabulated data rather than approximating functions. The tabulated data embody the solutions of the radiative transfer equation for numerous combinations of optical thicknesses and line widths. The algorithm is thoroughly verified with synthetic spectra.
Laser-induced plasmas are widely used in many areas of science and technology; examples include spectrochemical analysis, thin film deposition, material processing, and even jet propulsion. Several topics will be addressed. First, general phenomenology of laser-induced plasmas will be discussed. Then, a chemical model will be presented based on a coupled solution of Navier-Stokes, state, radiative transfer, material transport, and chemical (Guldberg-Waage) equations. Results of computer simulations for several chemical systems will be shown and compared to experimental observations obtained by optical imaging, spectroscopy, and tomography. The latter diagnostic tools will also be briefly discussed. Finally, a prospective application of laser-induced plasma and plasma modeling will be illustrated on the example of calibration-free MC LIBS (Monte Carlo Laser Induced Breakdown Spectroscopy), in which concentrations of elements in materials are found by fitting model-generated and experimental spectra.
Selected resonance states of the deuterated formyl radical in the electronic ground state X^2A´ are computed using our recently introduced dynamically pruned discrete variable representation [H. R. Larsson, B. Hartke, and D. J. Tannor, J. Chem. Phys. 145, 204108 (2016)]. Their decay and asymptotic distributions are analyzed and, for selected resonances, compared to experimental results obtained by a combination of stimulated emission pumping and velocity-map Imaging of the product D atoms.
The theoretical results show good agreement with the experimental kinetic energy distributions. The intramolecular vibrational energy redistribution is analyzed and compared with previous results from an effective polyad Hamiltonian. Specifically, we analyzed the part of the wavefunction that remains in the interaction region during the decay. The results from the polyad Hamiltonian could mainly be confirmed. The C=O stretch quantum number is typically conserved, while the D-C=O bend quantum number decreases. Differences are due to strong anharmonic coupling such that all resonances have major contributions from several zero-order states. For some of the resonances, the coupling is so strong that no further zero-order states appear during the dynamics in the interaction region, even after propagating for 300 ps.
Probe 1, which contains an anilinopyridine chromophore and an azaoxa macrocyclic subunit, presented an absorption band centered at 340 nm in acetonitrile. Addition of Fe(III), Cr(III) and Hg(II) induced the growth of a new absorption band at 430 nm (with color change from colorless to yellow), whereas in the presence of Cu(II), Zn(II) and Pb(II), less marked changes were observed. The color changes observed upon addition of Fe(III), Cr(III) and Hg(II) were ascribed to the formation of 1:1 stoichiometry complexes with probe 1. Coordination of Fe(III), Cr(III) and Hg(II) with the pyridine fragment of 1 induced an enhancement of the charge transfer character accompanied with a marked bathochromic shift that was reflected in a color change from colorless to yellow. The strength of the interaction between probe 1 and Fe(III) cation was modulated upon interaction with anions. Of all the anions tested, only cyanide was able to induce the bleaching of the yellow 1·Fe(III) complex solution. This bleaching was ascribed to
the formation of 1·Fe(III)-CN complex that restored, to some extent, the optical features of the free probe allowing the chromogenic sensing of cyanide. Besides, 1·Fe(III) complex was used to detect
cyanide in acetonitrile-water 90:10 v/v mixtures with good recoveries.
Small-molecule oxoanions are often imprinted noncovalently as carboxylates into molecularly imprinted polymers (MIPs), requiring the use of an organic counterion. Popular species are either pentamethylpiperidine (PMP) as a protonatable cation or tetraalkylammonium (TXA) ions as permanent cations. The present work explores the influence of the TXA as a function of their alkyl chain length, from methyl to octyl, using UV/vis absorption, fluorescence titrations, and HPLC as well as MD simulations. Protected phenylalanines (Z-L/D-Phe) served as templates/analytes. While the influence of the counterion on the complex stability constants and anion-induced spectral changes shows a monotonous trend with increasing alkyl chain length at the prepolymerization stage, the cross-imprinting/rebinding studies showed a unique pattern that suggested the presence of adaptive cavities in the MIP matrix, related to the concept of induced fit of enzyme−substrate interaction. Larger cavities formed in the presence of larger counterions can take up pairs of Z-X-Phe and smaller TXA, eventually escaping spectroscopic detection. Correlation of the experimental data with the MD simulations revealed that counterion mobility, the relative distances between the three partners, and the hydrogen bond lifetimes are more decisive for the response features observed than actual distances between interacting atoms in a complex or the orientation of binding moieties. TBA has been found to yield the highest imprinting factor, also showing a unique dual behavior regarding the interaction with template and fluorescent monomer. Finally, interesting differences between both enantiomers have been observed in both theory and experiment, suggesting true control of enantioselectivity. The contribution concludes with suggestions for translating the findings into actual MIP development.
Due to the increasing consumption of cereals worldwide, monitoring of growth, storage and processing is becoming more crucial. Particularly when stored, infested grains breed fungal clusters (“hot spots”) in which mycotoxins greatly exceed allowed maximum levels. Because of their unpredictable presence, current sampling and procedures for mycotoxin analysis are complex and contain invasive and cost intensive steps.
A possible approach to avoid sampling inaccuracies is the non-invasive analysis of the homogeneous gas phase above the crops, instead of analyzing random samples. However, this procedure requires microbial volatile organic compounds (MVOC´s) being released by the samples. Previous investigations revealed trichodiene to be a precursor in trichothecenes biosynthesis – one of the largest mycotoxin groups with more than 180 compounds. Due to its non-functionalized sesquiterpene structure, quantification of trichodiene using Headspace GC-MS methods is possible (e.g. [1]). Thereby, it could be used as biomarker for trichothecene contamination in foodstuff.
However, further studies are necessary. The correlation between trichodiene concentration in the gas phase and trichothecenes mass fraction in the sample must be examined closely to draw conclusions about the trichothecene content in samples. Realizing this idea, would widely extend the applicability of trichodiene and enormously simplify trichothecene quantification. Hence, this first step of an ongoing study aims to develop a laboratory reference method using trichodiene as volatile biomarker to quantify trichothecenes in cereals. Static headspace and SPME-enrichment coupled to gas chromatography with mass spectrometry (GC-MS) were employed. In a second step, this reference method is intended to validate new approaches for fast on-site screening of trichodiene in cereals.
Statistic process control as well as process capability demand for calibrated determination of layer thicknesses in various industries, e.g. automotive, aerospace, microelectronics manufacturing. Calibration requires well know and well characterized samples. A calibration laboratory accredited according to DIN EN ISO 17025 has the objective to distribute standards traceable to SI units to industrial laboratories for quality control of manufacturing of various products. Especially, the thickness determination of thin metallic coatings e.g. from galvanic processes or layer deposition using X-Ray Fluorescence can be significantly improved by customized calibration samples. This is essential as the measurement uncertainty directly correlates to the capability performing reliable control of processes with high yield. For calibration laboratories, the validation of results using round robins and the direct comparison to national metrology institutes is a prerequisite to demonstrate the competence to perform calibration services.
In this paper a strategy to obtain traceability and validation for thin alloy layers as well as first results are presented. The combined use of the accredited method for determination of mass per area from measurement of mass and area combined with standard free X-Ray Fluorescence as well as chemical analysis of dissolved samples with thin layers is deployed for material systems as NixZn1-x as well as NixP1-x. The obtained results are compared to reference free X-Ray Fluorescence at the BESSY II laboratories of Physikalisch-Technische Bundesanstalt. An excellent agreement of the obtained measured values as mass per unit area and alloy concentrations from the different applied methods within the measurement uncertainty was observed for NixP1-x showing the successful performed traceability of the calibration samples to SI units in combination with a validation of results by national metrology institutes and the round robin approach.
IAPR participates in the EMPIR 16SRT02, entitled ‘Certified forensic alcohol reference materials - ALCOREF’ funded by EURAMET as an external funded partner. The Research in this project will address the needs for better enforcement of drink-driving legislation in several European countries, by building up long-term capacities for the production and certification of forensic alcohol reference materials, suitable for the calibration of evidential breath alcohol analyzers. The certification procedure includes characterization of the materials, assessment of homogeneity, stability, and uncertainty estimation. An interlaboratory comparison will be conducted to test the materials and capabilities developed. EMPIR 16SRT02-ALCOREF project is coordinated by BAM (DE).
We synthesized and characterized a set of ultrasmall hexagonal-phase NaGdF4: 20% Yb3+, 2% Er3+ upconversion nanoparticles with core diameters of 3.7 ± 0.5 nm. In order to assess passivation effects and the influence of possible core−shell intermixing and to identify optimum particle structures for combined imaging in the visible and near-infrared (vis−NIR: 410−850 nm) and short-wave infrared (SWIR: 1520 nm), NaYF4 shells of varying thicknesses (monolayer to 10 nm) were introduced and the influence of this parameter on the upconversion and downshifting photoluminescence of these particles was studied at different excitation power densities. This included excitation power-dependent emission spectra, slope factors, quantum yields, and excited state decay kinetics. These measurements revealed enhancement factors of the upconversion quantum yield of >10 000 in the low power region and an excitation power density-independent quantum yield of the downshifted emission at 1520 nm between 0.1 and 14%. The optimized shell thickness for combined vis and SWIR imaging was identified as 5 nm. Moreover, lifetimes and quantum yields can be continuously tuned by shell thickness which can be exploited for lifetime multiplexing and encoding. The fact that we did not observe a saturation of the upconversion quantum yield or the excited state decay kinetics with increasing shell thickness is ascribed to a strong intermixing of the active core with the inert shell during the shelling procedure. This indicates the potential of spectroscopic tools to detect cation intermixing.
Sialic acid (SA) is a cell surface glycan, which has a decisive role in many cell activities including differentiation, proliferation, and the immune response. The amount of SA has been found to correlate with cancer, with an upregulation on more aggressive cancers. Therefore, there is a great interest in developing methods for detection of SA on cancer cells. We are screening SA on cancer cell lines by using fluorescent molecularly imprinted polymers, SA-MIPs. Macrophages, which evolve from mono-cytes, are well known for their extraordinary ability to phagocytose foreign objects. This could lead to the hypothesis that the SA-MIPs can be recognized by macrophages as foreign object; thus leading to internalization and potentially degradation.
We have demonstrated that SA-MIPs can be detected after incubation with the RAW macrophage cells, with increasing fluorescence over time. The microscopy analysis shows that the RAW cells ingest the SA-MIP particles. This information is important when planning to use SA-MIPs in future in vivo applications.
Sialic acid (SA) is a cell surface glycan, which has a strong role in many cell activities including differentiation, proliferation, and the immune response. The amount of SA has been found to be correlated with cancer, with an upregulation on more aggressive cancers. Therefore, there is great interest in developing methods for detection of SA on cancer cells. We are screening SA on cancer cell lines by using fluorescent molecularly imprinted polymers, SA-MIPs.Macrophages, which evolve from mono-cytes, are well known for their extraordinary ability to phagocytose foreign objects. This could lead to the hypothesis that the SA-MIPs can be recognized by macrophages as foreign object; thus leading to internalization and potential degradation. We have discovered that SA-MIPs can be detected after incubation with the RAW macrophage cells, with increasing fluorescence over time. The microscopy analysis shows that the RAW cells ingest the SA-MIP particles. This information is important when planning to use SA-MIPs in future in vivo applications.
Fluorescent carbon nanodots (CNDs) are very promising nanomaterials for a broad range of applications because of their high photostability, presumed selective luminescence, and low cost at which they can be produced. In this respect, CNDs are superior to well-established semiconductor quantum dots and organic dyes. However, reported synthesis protocols for CNDs typically lead to low photoluminescence quantum yield (PLQY) and low reproducibility, resulting in a poor understanding of the CND chemistry and photophysics. Here, we report a one-step synthesis of nitrogen-doped carbon nanodots (N-CNDs) from various carboxylic acids, Tris, and ethylenediaminetetraacetic acid resulting in high PLQY of up to 90%. The reaction conditions in terms of starting materials, temperature, and reaction time are carefully optimized and their influence on the photophysical properties is characterized. We find that citric acid-derived N-CNDs can result in a very high PLQY of 90%, but they do not Show selective luminescence. By contrast, acetic acid-derived N-CNDs show selective luminescence but a PLQY of 50%. The chemical
composition of the surface and core of these two selected N-CND types is characterized among others by high-Resolution synchrotron X-ray photoelectron spectroscopy using single isolated N-CND clusters. The results indicate that photoexcitation occurs in the N-CND core, whereas the emission properties are determined by the N-CND surface groups.
The impact of nanoparticles, NPs, at the single cell level has become a major field of toxicological research and different analytical methodologies are being investigated to obtain biological and toxicological information to better understand the mechanisms of cell–NP interactions. Here, inductively coupled plasma mass spectrometry in the single cell measurement mode (SC-ICP-MS) is proposed to study the uptake of silver NPs, AgNPs, with a diameter of 50 nm by human THP-1 monocytes in a proof-ofprinciple experiment. The main operating parameters of SC-ICP-MS have been optimized and applied for subsequent quantitative analysis of AgNPs to determine the number of particles in individual cells using AgNP suspensions for calibration. THP-1 cells were incubated with AgNP suspensions with concentrations of 0.1 and 1 µg/mL for 4 and 24 hours. The results reveal that the AgNP uptake by THP-1 monocytes is minimal at the lower dose of 0.1 µg/mL (roughly 1 AgNP per cell was determined), whereas a large cell-to-cell variance dependent on the exposure time is observed for a 10 times higher concentration (roughly 7 AgNPs per cell). The method was further applied to monitor the AgNP uptake by THP-1 cells differentiated macrophages incubated at the same AgNP concentration levels and exposure times demonstrating a much higher AgNP uptake (roughly from 9 to 45 AgNPs per cell) that was dependent on exposure concentration and remained constant over time. The results have been compared and validated by sample digestion followed by ICP-MS analysis as well as with other alternative promising techniques providing single cell analysis.
Carbamazepine (CBZ) and cetirizine (CTZ) are pharmaceutical drugs detected in the aquatic environment. However, the effects to marine invertebrates derived from the combination of these drugs with decreased pH conditions due to ocean acidification are poorly explored. This study investigated the biochemical parameters related to metabolic capacity and oxidative stress response and the transcription of genes related to the mode of action (MoA) of CBZ (1.0 μg/L) and CTZ (0.6 μg/L) in the clam Ruditapes philippinarum chronically exposed (28 days) to control (7.8) and low (7.5) pH conditions. The biochemical parameters applied were: the activity of electron transport system (indicator of organisms’ metabolic capacity); lipid peroxidation content (indicator of cell damage); total glutathione peroxidase activity (indicator of antioxidant defense). The transcription of genes related with drug neurotransmission and metabolism, cell defense and immunity and biomineralization was studied. No metabolic changes and oxidative stress was induced by the exposure to CBZ or CTZ at each pH level, but the transcription of several genes related with the MoA (neurotransmission, immunity and biomineralization) was altered by low pH, drug exposure and the combination of both stressors. In conclusion, it was shown that the interaction of drug exposure and low pH conditions can change bivalves’ sensitivity to drugs or alter drugs toxicity.
Diclofenac (DCF) is a widely used drug against fever, inflammation, pain, and rheumatic diseases. An average of 70 % of the ingested diclofenac is excreted in the urine. Thus, 63 tons per year are introduced into the water cycle in Germany. Due to insufficient removal of diclofenac in wastewater treatment plants, residues of diclofenac can be found in surface water and sometimes in drinking water. In order to establish an immunoassay, an anti-DCF antibody was required. Some antibody developments have been reported, based on an immunogen resulting from direct coupling of diclofenac to proteins via the carboxylic function. Finally, we used a monoclonal antibody, clone F01G21.
Highly selective and sensitive antibodies are only available for a limited number of small molecules. Hence the development of new antibodies is important to exploit the full potential of immunoanalytics. Small molecules do not elicit an immune response in mammals unless conjugated to carrier molecules. The choice of the structures to be conjugated, called haptens, is critical for the antibody production. Here we present our Approach to produce antibodies for the plasticizer diisononyl 1,2-cyclehexane-dicarboxylic acid (DINCH) and di-2-ethylhexyl terephthalate (DEHT) as well as the bile acid isolithocholic acid (ILA).
A 2-dimensional high-throughput screening method is presented to select peptide sequences from large peptide libraries for precision formulation additives, having a high capacity to specifically host a drug of interest and provide tailored drug release properties. The identified sequences are conjugated with poly(ethylene glycol) (PEG) to obtain peptide-PEG conjugates that proved to be valuable as solubilizers for small organic molecule drugs to overcome limitations of poor water-solubility and low bio-availability. The 2D-screening method selects peptide sequences on both (i) high loading capacities and (ii) preferred drug-release capabilities as demonstrated on an experimental Tau-protein aggregation inhibitor/Tau- deaggregator with potentials for an anti-Alzheimer disease drug (BB17). To enable 2D-screening, a one-bead one-compound (OBOC) peptide library was immobilized on a glass slide, allocating individual beads to permanent positions. While the first screening step involved incubation of the supported OBOC library with BB17 to identify beads with high drug binding capacities by fluorescence scanner readouts, the second step reveals release properties of the high capacity binders by incubation with blood plasma protein model solutions. Efficiently peptides with high BB17 capacities and either keeper or medium or fast releaser properties can be identified by direct sequence readouts from the glass slide supported resin beads via matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometry. Four peptides are synthesized as peptide-PEG solubilizers representing strong, medium, weak releasers and non-binders. Loading capacities reached up to 1:3.4 (mol drug per mol carrier) and release kinetics (fast/medium/slow) are in agreement with the selection process as investigated by fluorescence anisotropy and fluorescence correlation spectroscopy. The ability of BB17/conjugate complexes to inhibit the aggregation of Tau4RDΔK (four repeat Tau ((M)Q244-E372 with deletion of K280), 129 residues) in N2a cells is studied by a Tau-pelleting assay showing the modulation of cellular Tau aggregation. Promising effects such as the reduction of 55% of total Tau load are observed for the strong releaser additive. Studies of in vitro Thioflavin S Tau-aggregation assays show half-maximal inhibitory activities (IC50 values) of BB17/conjugates in the low micro-molar range.
Dye-stained micrometer-sized polymer beads are important tools in the life sciences with applications in biomedical, biochemical, and clinical research. Here, bead-based assays are increasingly used, for example, in DNA sequencing and the detection of autoimmune diseases or pathogenic microorganisms. Moreover, stained beads are employed as calibration tools for fluorescence microscopy and flow cytometry methods with increasing complexity. To address the requirements concerning the relevant fluorescence features, the spectroscopic properties of representative polymer beads with diameters ranging from about 1 to 10 μm stained with varying concentrations of rhodamine 6G were systematically assessed. The observed dependence of the spectral properties, fluorescence decay kinetics, and fluorescence quantum yields on bead size and dye loading concentration is attributed to different fluorescence characteristics of fluorophores located in the particle core and near-surface dye molecules. Supported by the fluorescence anisotropy measurements, the origin of the observed alteration of fluorescence features is ascribed to a combination of excitation energy transfer and polarity-related effects that are especially pronounced at the interface of the bead and the surrounding medium. The results of our studies underline the need to carefully control and optimize all Parameters that can affect the fluorescence properties of the dye-stained beads.
Raw data from metabolomics experiments are initially subjected to peak identification and signal deconvolution to generate raw data matrices m × n, where m are samples and n are metabolites. We describe here simple statistical procedures on such multivariate data matrices, all provided as functions in the programming environment R, useful to normalize data, detect biomarkers, and perform sample classification.
“Fluxomics” refers to the systematic analysis of metabolic fluxes in a biological system and may uncover novel dynamic properties of metabolism that remain undetected in conventional metabolomic approaches. In labeling experiments, tracer molecules are used to track changes in the isotopologue distribution of metabolites, which allows one to estimate fluxes in the metabolic network. Because unidentified compounds cannot be mapped on pathways, they are often neglected in labeling experiments. However, using recent developments in de novo annotation may allow to harvest the information present in these compounds if they can be identified. Here, we present a novel tool (HiResTEC) to detect tracer incorporation in high-resolution mass spectrometry data sets. The software automatically extracts a comprehensive, nonredundant list of all compounds showing more than 1% tracer incorporation in a nontargeted fashion. We explain and show in an example data set how mass precision and other filter heuristics, calculated on the raw data, can efficiently be used to reduce redundancy and noninformative signals by 95%. Ultimately, this allows to quickly investigate any labeling experiment for a complete set of labeled compounds (here 149) with acceptable false positive rates. We further re-evaluate a published data set from liquid chromatography-electrospray ionization (LC-ESI) to demonstrate broad applicability of our tool and emphasize importance of quality control (QC) tests. HiResTEC is provided as a package in the open source software framework R and is freely available on CRAN.
Gold-shell coated NaYF4:Er3+, Yb3+ nanoparticles for the enhancement of fluorescence emission
(2018)
In the present work, we aim to explore how far the UCNP emission intensity can be enhanced by the aid of plasmonic interactions using a gold shell. The distance between the UCNP core and the gold shell is varied by adding a silica spacer of different thicknesses.
The synthetic conditions for obtaining UCNP@SiO2@Au core-shell nanoparticles with precisely tuneable silica shell thicknesses were investigated. A gold shell on the UCNP@SiO2 nanoparticles is expected to give rise to a noticeable enhancement of particle brightness and fluorescence, given that the thicknesses of the silica shell and the gold coating can be controlled and fine-tuned. First single particle studies revealing shortening of the Er3+ lifetimes suggest that plasmonic enhancement occurs.
Comparing the photoluminescence (PL) properties of ensembles of nanocrystals like semiconductor quantum dots (QDs) with single particle studies is of increasing interest for many applications of These materials as reporters in bioimaging studies performed under very dilute conditions or even at the single particle level. Particularly relevant is here the PL quantum yield (ΦF), which determines the signal size together with the reporter’s molar extinction coefficient and is a direct measure for nanocrystal quality, especially for the inorganic surface passivation shell and its tightness, which can be correlated also with nanocrystal stability and the possible release of heavy metal ions. Exemplarily for red and green emitting CdTe nanocrystals, we present a method for the determination of ΦF of nanoparticle dispersions at ultralow concentration compared to cuvette measurements using fluorescence correlation spectroscopy (FCS), a single molecule method, and compared to molecular dyes with closely matching spectral properties and known ΦF. Our results underline the potential of this approach, provided that material-inherent limitations like ligand- and QD-specific aggregation affecting particle diffusion and QD drawbacks such as their complex and power-dependent blinking behavior are properly considered as shown here.
Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the sticky character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing an LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend an LC-MS/MS-based quantification method with a dynamic range of 0.5–40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials.
Phage display is used to find specific target binding peptides for polypropylene (PP) surfaces. PP is one of the most commonly used plastics in the world. Millions of tons are produced every year. PP binders are of particular interest because so far gluing or printing on PP is challenging due to its low surface energy. A phage display protocol for PP was developed followed by Next Generation DNA Sequencing of the whole phage library. Data analysis of millions of sequences yields promising peptide candidates which were synthesized as PEG conjugates. Fluorescence-based adsorption-elution-experiments show high adsorption on PP for several sequences.
Gold-shell coated NaYF4:Er3+, Yb3+ nanoparticles for the enhancement of fluorescence emission
(2018)
In the present work, we aim to explore how far the UCNP emission intensity can be enhanced by the aid of plasmonic interactions using a gold shell. The distance between the UCNP core and the gold shell is varied by adding a silica spacer of different thicknesses.
The synthetic conditions for obtaining UCNP@SiO2@Au core-shell nanoparticles with precisely tuneable silica shell thicknesses were investigated. A gold shell on the UCNP@SiO2 nanoparticles is expected to give rise to a noticeable enhancement of particle brightness and fluorescence, given that the thicknesses of the silica shell and the gold coating can be controlled and fine-tuned. First single particle studies revealing shortening of the Er3+ lifetimes suggest that plasmonic enhancement occurs.
The comparison required the assignment of the mass fraction of folic acid present as the main component in the comparison sample. Performance in the comparison is representative of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molecular weight range 300–500] and high polarity (pKOW < −2).
Methods used by the eighteen participating NMIs or DIs were based on a mass balance (summation of impurities) or qNMR approach, or the combination of data obtained using both methods. The qNMR results tended to give slightly lower values for the content of folic acid, albeit with larger associated uncertainties, compared with the results obtained by mass balance procedures. Possible reasons for this divergence are discussed in the report, without reaching a definitive conclusion as to their origin.
The comparison demonstrates that for a structurally complex polar organic compound containing a high water content and presenting a number of additional analytical challenges, the assignment of the mass fraction content property value of the main component can reasonably be achieved with an associated relative standard uncertainty in the assigned value of 0.5%
Aim of the Federal Institute for Materials Research and Testing (BAM) in the frame of I4S - “Intelligence for Soil” is the characterization of an X-ray fluorescence (XRF) based sensor for robust online-application of arable land.Fast soil mapping for agricultural purpose allows the site-specific optimized introduction of plant essential nutrients like S, K, Ca, and Fe. This is important given that the distribution of minor and trace elements varies widely. The non-destructive and contactless XRF is suitable for rapid in-situ analysis on the field due to minimal sample preparation and simultaneous multi-element analysis.
Soils are already considered as a complex matrix due to their wide range of elements in different contents, especially light elements with low atomic numbers (Z<19). Problems by measuring soil samples also arise from heterogeneity of the sample and matrix effects. Large grain size distribution causes strong inhomogeneity and matrix effects occur through physical properties related to high concentration of main components. Matrix-specific calibration strategies for determination of total major and minor plant essential nutrients are particularly important regarding these difficulties. For accurate calibration, data treatment and evaluation must also be considered. Empirical univariate and multivariate data analysis were compared regarding their analytical figures of merit. Using principal component analysis (PCA) it was possible to classify German soils in different groups as sand, clay and silt. A calibration curve was obtained by partial least squares regression (PLSR) and the elemental content of German soils was predicted. Elemental distribution maps for different German arable lands were created and the results compared to reference measurements. The correlation between predicted values and reference values were in good agreement for most major and minor nutrients.
In respect of an efficient cultivation of agricultural cropland, a site-specific fertility management is necessary. Therefore, affordable and extensive mapping methods are needed. The research projects I4S (intelligence for soil) has the goal to develop a system for this purpose. I4S is one of ten interdisciplinary research project associations of the innovation programme called BonaRes, which is funded by the German Federal Ministry of Education and Research (BMBF).
The system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS. The main task of LIBS measurements in this project is the real-time determination of the elemental contents of major and minor nutrients in soils, like calcium, magnesium, potassium. LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. The main task of LIBS measurements in this project is the real-time determination of the elemental contents of nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate which circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better reproducibility of the obtained signal, a double-pulse Nd:YAG laser (1064 nm)was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated. When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, chemometric methods were used. With the principal component analysis (PCA) a classification of soils into different soil types was performed and a calibration curve based on partial least squares regression (PLSR) was generated. With this calibration model’s elemental distribution maps for different German agricultural fields were created.
Many applications of nanomaterials in the life sciences require the controlled functionalization of these materials with ligands like polyethylene glycol (PEG) and/or biomolecules such as peptides, proteins, and DNA. This enables to tune their hydrophilicity and biocompatibility, minimize unspecific interactions, improve biofunction-nalization efficiencies, and enhance blood circulation times and is the ultimate prerequisite for their use as reporters in assays or the design of targeted optial probes for bioimaging.
At the core of these functionalization strategies are reliable and validated methods for surface group and ligand quantification that can be preferably performed with routine laboratory instrumentation, require only small amounts of substances, and are suitable for many different types of nanomaterials.
We present here versatile and simple concepts for the quantification of common functional groups, ligands, and biomolecules on different types of organic and inorganic nano-materials, using different types of optical reporters and method validation with the aid of multimodal reporters and mass balances.
The aim of this work is to investigate the Synthesis of core-shell upconverting nanoparticles (UCNP).
The UCNP are coated with a Gold Shell to plasmonically enhance the fluorescence emision. The distance between the UCNP core and the plasmonic structure is tuned by the aid of a silica at different Shell thicknesses.
The interaction of nanoparticles (NPs) with cells has become a major field of interest, ranging from medical applications to nanotoxicology. Size, shape and surface modification of the NPs determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. In recent years, it was shown that LA-ICP-MS can provide quantitative as well as distribution information of NPs in cell samples.
Here LA-ICP-MS was applied for the imaging of individual cells to study the uptake and intracellular processing of metal-containing nanostructures. Additionally, the local distribution of naturally occurring elements in cells like P was measured to indicate cell morphology. The cells were incubated with different types of NPs under varying experimental conditions. For LA analysis, the cells were fixed and dried.
Our findings show, that LA-ICP-MS is suitable for the localisation of nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physicochemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time.
The results demonstrate the potential of LA-ICP-MS providing insight into NP uptake, intracellular distribution and cell-to-cell variation dependent on experimental parameters.
As part of the BonaRes research initiative funded by the German Federal Ministry of Education and Research (BMBF), strategies are being developed to use soil as a sustainable resource in the bioeconomy. The interdisciplinary subproject I4S - “Intelligence for soil” - is responsible for the development of an integrated system for site-specific management of soil fertility. For this purpose, a platform is constructed and various sensors are installed. Real-time data will be summarized in models and decision-making algorithms will be used to control fertilization and accordingly improve soil functions. This would allow investigations in close meshed dynamic grid and fast analysis of large areas to generate higher yields. This is important given that the distribution of minor and trace elements varies widely. Aim of the Federal Institute for Materials Research and Testing (BAM) in the frame of I4S is the characterization of an X-ray fluorescence (XRF) based sensor for robust online-analysis of arable land. The non-destructive and contactless XRF is suitable for rapid in-situ analysis on the field due to minimal sample preparation and simultaneous multi-element analysis.
Soils are already considered as a complex matrix due to their wide range of elements in different contents, especially light elements with low atomic numbers (Z<19). Problems by measuring soil samples also arise from heterogeneity of the sample and matrix effects. Large grain size distribution causes strong inhomogeneity and matrix effects occur through physical properties related to high concentration of main components. Matrix-specific calibration strategies for determination of total major and minor plant essential nutrients are particularly important regarding these difficulties. For accurate calibration, data treatment and evaluation must also be considered. Univariate and multivariate data analysis were compared regarding their analytical figures of merit. Using principal component analysis (PCA) it was possible to classify German soils in different groups as sand, clay and silt. Calibration models were obtained by partial least squares regression (PLSR) and the content of macro- and micronutrients in German soils was predicted. Elemental distribution maps for different German arable lands were created and the results compared to reference measurements. The correlation between predicted values and reference values were in good agreement for most major and minor nutrients.
In respect of an efficient cultivation of agricultural cropland, a site-specific fertility management is necessary. Therefore, affordable and extensive mapping methods are needed. For this purpose, the research project I4S (intelligence for soil) has the goal to develop an integrated system. This system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS.
LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. The main task of LIBS measurements in this project is the real time determination of the elemental contents of nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate which circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better reproducibility of the obtained signal, a double-pulse Nd:YAG laser (1064 nm) was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated.[1] When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, chemometric methods were used. With the principal component analysis (PCA) a classification of soils into different soil types was performed and a calibration curve based on partial least squares regression (PLSR) was generated. With this calibration model’s elemental distribution maps for different German agricultural fields were created.
Bestimmung von Makro- und Mikronährstoffen in Böden mittels laserinduzierter Plasmaspektroskopie
(2018)
In respect of an efficient cultivation of agricultural cropland, a site-specific fertility management is necessary. Therefore, affordable and extensive mapping methods are needed. The research projects I4S (intelligence for soil) has the goal to develop a system for this purpose. I4S is one of ten interdisciplinary research project associations of the innovation programme called BonaRes, which is funded by the German Federal Ministry of Education and Research (BMBF).
The system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS. The main task of LIBS measurements in this project is the real-time determination of the elemental contents of major and minor nutrients in soils, like calcium, magnesium, potassium. LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. The main task of LIBS measurements in this project is the real-time determination of the elemental contents of nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate which circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better reproducibility of the obtained signal, a double-pulse Nd:YAG laser (1064 nm) was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated. When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, chemometric methods were used. With the principal component analysis (PCA) a classification of soils into different soil types was performed and a calibration curve based on partial least squares regression (PLSR) was generated. With this calibration model’s elemental distribution maps for different German agricultural fields were created.
Studies on the development of antibodies for the highly hydrophobic plasticizers DINCH and DEHT
(2018)
Diisononylcyclohexane-1,2-dicarboxylate (DINCH) and di-2-ethylhexyl terephthalate (DEHT), two of the most important substitutes for phthalate plasticizers, are used for a wide range of applications. Consequently, an increasing occurrence in urine and environmental samples is reported. Reliable and fast analytical methods for the quantification of these plasticizers are needed. So far, mainly GC-MS or LC-MS methods are used. We aimed to develop the first antibodies and immunoassays allowing for high-throughput analysis of samples. We designed two DINCH hapten structures and one DEHT hapten structure and employed hapten-protein conjugates for the immunization of rabbits. Sensitive competitive enzyme-linked immunosorbent assays (ELISAs) against each hapten using the produced polyclonal antibodies were established. Yet, binding of DINCH to the respective antibodies was not observed in neither direct nor indirect assay formats, even when using protein conjugates with the heterologous haptens and different carrier proteins in the indirect format. The use of surfactants and solvents in the sample buffer did not result in recognition of the plasticizers. Also, no binding of DEHT in ELISA employing the respective antibodies was detected. We speculate that the production of antibodies against these highly hydrophobic molecules is not possible via our route, however a different hapten design could overcome this obstacle.
The aim of this study was to identify specific chemical bonds and characteristic structures in melanoidins formed from D-glucose and L-alanine between 130 and 200 °C. The results might be used to control the type and amount of melanoidin produced during food processing. For this purpose, complementary techniques, such as FTIR, NMR, EPR, and MALDI-ToF, were employed. At 160 °C color, solubility and UV/Vis absorption change characteristically and consequently, structural transformations could be observed in FTIR and NMR spectra. For example, sharp signals of N-H, C-N, and C-H oscillations in the L-alanine spectrum are prone to inhomogeneous broadening in melanoidins prepared above 150 °C. These changes are caused due to formation of heterogeneous macromolecular structures and occur during condensation reactions that lead to an increasing loss of water from the melanoidins with increasing temperatures. Additionally, MALDI-ToF-MS indicates the polymerization of glyoxal/glyoxylic acid and EPR shows the formation of radical structures.
An immunohistochemical method is described to visualize the distribution of metallothioneins 1/2 (MT 1/2) and metallothionein 3 (MT 3) in human ocular tissue. It is making use of (a) antibodies conjugated to gold nanoclusters (AuNCs) acting as labels, and (b) laser ablation (LA) coupled to inductively coupled plasma – mass spectrometry (ICP-MS).Water-soluble fluorescent AuNCs (with an average size of 2.7 nm) were synthesized and then conjugated to antibody by carbodiimide coupling. The surface of the modified AuNCs was then blocked with hydroxylamine to avoid nonspecific interactions with biological tissue. Immunoassays for MT 1/2 and MT 3 in ocular tissue sections (5 μm thick) from two post mortem human donors were performed. Imaging studies were then performed by fluorescence using confocal microscopy, and LA-ICP-MS was performed in the retina to measure the signal for gold. Signal amplification by the >500 gold atoms in each nanocluster allowed the antigens (MT 1/2 and MT 3) to be imaged by LA-ICP-MS using a laser spot size as small as 4 μm. The image patterns found in retina are in good agreement with those obtained by conventional fluorescence immunohistochemistry which was used as an established reference method.
Heritage Lecture
(2018)
After finishing my diploma thesis in plasma physics in 1981, I dreamt of a future in a research lab to develop novel fusion reactors for energy production or to study universal plasmas and their emission in the cosmos. This dream never became real, however I found my first job in a team to build up a new museum dedicated to “Energy”, and this first part of my career was already finished after a year, because the funding was not extended. So, I found immediately a new job as a young scientist in the institute for analytical sciences (originally ISAS: Institute for Plasmachemistry and Applied Spectroscopy) in 1982 to develop novel plasma ion sources for inorganic mass spectrometry. The first source of interest was based on a glow discharge for direct analysis of conducting solids (technically supported by Finnigan MAT, Bremen). Here I adopted the design of the Grimm type discharge for the first time, which was well known in optical emission spectroscopy, and coupled it to a quadrupole mass analyzer. The advantage of this design was that flat craters are produced by sputtering which made this source very powerful for in-depth analysis of technical layers. This then became the topic of my PhD, which was not originally planned, and I had to learn a lot about surface analysis. However, since the first project was too successful we established a small team (in cooperation with Jose Broekaert - an expert in ICP-OES) which started with the development of our own inductively coupled plasma ion source in 1986 coupled to a quadrupole and in 1989 to a sector field mass spectrometer (funded by the Minister of Science and Technology; again in cooperation with Finnigan MAT). The latter device was launched to the market in 1993 as the Element 1.
The second decade of my career was still related to instrumental development but mainly of glow discharge sources. In an EU funded project first an automated glow discharge sector field instrument was developed where the Grimm type geometry was combined with a fast flow concept (in cooperation with Volker Hoffmann at IFW in Dresden). This was done in cooperation with VG (which became later a part of Thermo Fisher Scientific together with Finnigan MAT), so that it is not surprising that this concept for the Element GD. This project was later continued in the third phase of my career, again funded by the EU and in cooperation with the group of Alfredo Sanz-Medel (Rosario Pereiro and Jorge Pisonero), to develop a fast flow, but now rf-powered GD ion source in combination with a time-of-flight mass spectrometer, which was later launched to the market commercially by Horiba Jobin Yvon (France) for in-depth profiling of thin layers even of non-conducting materials.
In the first decade of my career I started to study already “analytical chemistry” from the scratch because the instruments developed have been applied now for direct analysis of solid materials, technical layers and environmental samples. In case of environmental applications our ICP-MS (the quadrupole and the sector field instrument) was coupled with separation techniques, so that this period of instrumental development was dominated in the second decade by development of high efficiency sample introduction systems in combination with speciation studies of Pt group elements, arsenic, selenium and phosphorus (in DNA and phosphorylated proteins), Ni and Cr. Additionally, we continued with the analysis of solid ceramic materials (Al2O3, SiC, SiN) and ambient air-born particles. At the end of the second decade we complemented our instrumental pool by a collision and reaction cell instrument in cooperation with Micromass and used this instrument for speciation studies of peptides and proteins and demonstrated that by ICP-HEX-MS quantitative proteomics is feasible. Therefore, we more and more focused in the following years on metalloproteins and published a famous paper on “Metallobiomolecules: The basis of life, the challenge of atomic spectroscopy” (together with Luc Moens and Ryszard Lobinski). For detection of metalloproteins we applied typical workflows of biochemistry and proteomics, for which I had to extend my knowledge about biochemistry and proteomics. As a new analytical tool, we used a homemade laser ablation cell for sample introduction of metalloproteins after their separation by gel electrophoresis and extended this work by applying metal-tagging of antibodies for Western blot assays. For this purpose, proteins were separated in SDS-PAGE and electroblotted onto membranes. Specific detection of proteins even not containing any metal could be performed by laser ablation ICP-MS using the metal tagged antibodies for indirect detection. This research was interrupted in 2009 by a movement from ISAS (where atomic spectroscopy was declining) to BAM (the Federal Institute for Materials Research and Testing, Berlin) where this research direction was fostered. The experience we achieved at ISAS in the previously mentioned projects were now used here at BAM in the fourth decade for materials research and the development of a quantitative elemental microscope with cellular resolution. So, at the end of my career I am trying to apply all my knowledge and expertise to develop analytical methods and to apply multimodal spectroscopies to decipher the construction code of the cellular machinery, which is the most precise and complex machinery I have ever seen. If we were able to understand how this machinery works, we can better diagnose and treat a malfunction in case of the development of a disease.
Finally, I can conclude that lifelong learning starts before school but does not end at the end of this lecture. It looks like this heritage lecture will be focused on my career only, but this is not the case because some highlights of my career will be used to illustrate a few universal principles: how to have fun, how to find friends and how this all leads to an increase of joy and joy is the basis of new ideas (which must not always be related to your profession) and novel ideas are essential for a successful and satisfying career. So, this heritage lecture wants to answer the most important question of a life which was dedicated to plasma spectrochemistry:
1) Is it possible - at all - to have fun in this research direction?
2) Can we learn already today what we need tomorrow?
3) How can we still realize our scientific dreams of cutting edge research in times of cutting budgets? Which automatically leads to the next question:
4) Is necessity the mother of invention?
All questions will be answered! Controversial discussions (for angry or disappointed colleagues) will be stimulated and my visions of future research (for students and postdocs) and instrumental developments (for manufacturer) will be presented. Finally, conclusions will be drawn by the auditorium (everybody) and thanks will be given to Ramon Barnes (by me) already in advance!
Heritage Lecture
(2018)
After finishing my diploma thesis in plasma physics in 1981, I dreamt of a future in a research lab to develop novel fusion reactors for energy production or to study universal plasmas and their emission in the cosmos. This dream never became real, however I found my first job in a team to build up a new museum dedicated to “Energy”, and this first part of my career was already finished after a year, because the funding was not extended. So, I found immediately a new job as a young scientist in the institute for analytical sciences (originally ISAS: Institute for Plasmachemistry and Applied Spectroscopy) in 1982 to develop novel plasma ion sources for inorganic mass spectrometry. The first source of interest was based on a glow discharge for direct analysis of conducting solids (technically supported by Finnigan MAT, Bremen). Here I adopted the design of the Grimm type discharge for the first time, which was well known in optical emission spectroscopy, and coupled it to a quadrupole mass analyzer. The advantage of this design was that flat craters are produced by sputtering which made this source very powerful for in-depth analysis of technical layers. This then became the topic of my PhD, which was not originally planned, and I had to learn a lot about surface analysis. However, since the first project was too successful we established a small team (in cooperation with Jose Broekaert - an expert in ICP-OES) which started with the development of our own inductively coupled plasma ion source in 1986 coupled to a quadrupole and in 1989 to a sector field mass spectrometer (funded by the Minister of Science and Technology; again in cooperation with Finnigan MAT). The latter device was launched to the market in 1993 as the Element 1.
The second decade of my career was still related to instrumental development but mainly of glow discharge sources. In an EU funded project first an automated glow discharge sector field instrument was developed where the Grimm type geometry was combined with a fast flow concept (in cooperation with Volker Hoffmann at IFW in Dresden). This was done in cooperation with VG (which became later a part of Thermo Fisher Scientific together with Finnigan MAT), so that it is not surprising that this concept for the Element GD. This project was later continued in the third phase of my career, again funded by the EU and in cooperation with the group of Alfredo Sanz-Medel (Rosario Pereiro and Jorge Pisonero), to develop a fast flow, but now rf-powered GD ion source in combination with a time-of-flight mass spectrometer, which was later launched to the market commercially by Horiba Jobin Yvon (France) for in-depth profiling of thin layers even of non-conducting materials.
In the first decade of my career I started to study already “analytical chemistry” from the scratch because the instruments developed have been applied now for direct analysis of solid materials, technical layers and environmental samples. In case of environmental applications our ICP-MS (the quadrupole and the sector field instrument) was coupled with separation techniques, so that this period of instrumental development was dominated in the second decade by development of high efficiency sample introduction systems in combination with speciation studies of Pt group elements, arsenic, selenium and phosphorus (in DNA and phosphorylated proteins), Ni and Cr. Additionally, we continued with the analysis of solid ceramic materials (Al2O3, SiC, SiN) and ambient air-born particles. At the end of the second decade we complemented our instrumental pool by a collision and reaction cell instrument in cooperation with Micromass and used this instrument for speciation studies of peptides and proteins and demonstrated that by ICP-HEX-MS quantitative proteomics is feasible. Therefore, we more and more focused in the following years on metalloproteins and published a famous paper on “Metallobiomolecules: The basis of life, the challenge of atomic spectroscopy” (together with Luc Moens and Ryszard Lobinski). For detection of metalloproteins we applied typical workflows of biochemistry and proteomics, for which I had to extend my knowledge about biochemistry and proteomics. As a new analytical tool, we used a homemade laser ablation cell for sample introduction of metalloproteins after their separation by gel electrophoresis and extended this work by applying metal-tagging of antibodies for Western blot assays. For this purpose, proteins were separated in SDS-PAGE and electroblotted onto membranes. Specific detection of proteins even not containing any metal could be performed by laser ablation ICP-MS using the metal tagged antibodies for indirect detection. This research was interrupted in 2009 by a movement from ISAS (where atomic spectroscopy was declining) to BAM (the Federal Institute for Materials Research and Testing, Berlin) where this research direction was fostered. The experience we achieved at ISAS in the previously mentioned projects were now used here at BAM in the fourth decade for materials research and the development of a quantitative elemental microscope with cellular resolution. So, at the end of my career I am trying to apply all my knowledge and expertise to develop analytical methods and to apply multimodal spectroscopies to decipher the construction code of the cellular machinery, which is the most precise and complex machinery I have ever seen. If we were able to understand how this machinery works, we can better diagnose and treat a malfunction in case of the development of a disease.
Finally, I can conclude that lifelong learning starts before school but does not end at the end of this lecture. It looks like this heritage lecture will be focused on my career only, but this is not the case because some highlights of my career will be used to illustrate a few universal principles: how to have fun, how to find friends and how this all leads to an increase of joy and joy is the basis of new ideas (which must not always be related to your profession) and novel ideas are essential for a successful and satisfying career. So, this heritage lecture wants to answer the most important question of a life which was dedicated to plasma spectrochemistry:
1) Is it possible - at all - to have fun in this research direction?
2) Can we learn already today what we need tomorrow?
3) How can we still realize our scientific dreams of cutting edge research in times of cutting budgets? Which automatically leads to the next question:
4) Is necessity the mother of invention?
All questions will be answered! Controversial discussions (for angry or disappointed colleagues) will be stimulated and my visions of future research (for students and postdocs) and instrumental developments (for manufacturer) will be presented. Finally, conclusions will be drawn by the auditorium (everybody) and thanks will be given to Ramon Barnes (by me) already in advance!
A Proof of Concept: Are Detection Dogs a Useful Tool to Verify Potential Biomarkers for Lung Cancer?
(2018)
Early and reliable diagnostic test is essential for effective therapy of lung cancer. Volatile organic compounds that are characteristic for cancer could serve as valuable biomarkers in cancer diagnosis. Both trace analytical and detection dog approaches give some evidence for the existence of such biomarkers. In this proof of concept, study dogs and trace analysis were implemented in combination to gain more information concerning cancer biomarkers. Two dogs were trained to distinguish between absorbed breath samples of lung cancer patients and healthy persons and succeeded with correct identification of patients with 9/9 and 8/9 and correct negative indications from of 8/10 and 4/10 samples from healthy individuals. A recent observational study found that breath samples from lung cancer patients showed an increase in 1-butanol, 2-butanone, 2-pentanone, and hexanal. Synthetic air samples were therefore fortified with these compounds and adsorbed to a fleece. Tested against breath samples from healthy probands, on presentation to the dogs these synthetic samples provoked an indication in three out of four samples. We were able to demonstrate that a combination of the natural nose of a dog and a trace analytic technique can be a valuable concept in the search for cancer biomarkers.
Zearalenone (ZEN) and its phase II sulfate and glucoside metabolites have been detected in food and feed commodities. After consumption, the conjugates can be hydrolyzed by the human intestinal microbiota leading to liberation of ZEN that implies an underestimation of the true ZEN exposure. To include ZEN conjugates in routine analysis, reliable standards are needed, which are currently not available. Thus, the aim of the present study was to develop a facilitated biosynthesis of ZEN-14-sulfate, ZEN-14-glucoside and ZEN-16-glucoside. A metabolite screening was conducted by adding ZEN to liquid fungi cultures of known ZEN conjugating Aspergillus and Rhizopus strains. Cultivation conditions and ZEN incubation time were varied. All media samples were analyzed for metabolite formation by HPLC-MS/MS. In addition, a consecutive biosynthesis was developed by using Fusarium graminearum for ZEN biosynthesis with subsequent conjugation of the toxin by utilizing Aspergillus and Rhizopus species. ZEN-14-sulfate (yield: 49%) is exclusively formed by Aspergillus oryzae. ZEN-14-glucoside (yield: 67%) and ZEN-16-glucoside (yield: 39%) are formed by Rhizopus oryzae and Rhizopus oligosporus, respectively. Purities of ≥73% ZEN-14-sulfate, ≥82% ZEN-14-glucoside and ≥50% ZEN-16-glucoside were obtained by 1H-NMR. In total, under optimized cultivation conditions, fungi can be easily utilized for a targeted and regioselective synthesis of ZEN conjugates.
Mykotoxine werden als sekundäre Metabolite von Schimmelpilzen gebildet und haben diverse schädliche Effekte auf Menschen, Tiere und Pflanzen. Laut FAO sind weltweit bis zu 25 % aller Lebens- und Futtermittel mit Mykotoxinen kontaminiert, wodurch jährlich immense ökonomische Verluste entstehen.
Neben den eigentlichen Mykotoxinen rücken zunehmend deren Transformationsprodukte (TPs) in den Fokus. Diese können als natürliche Stoffwechselprodukte toxischer sein als das eigentliche Mykotoxin und stellen eine potenzielle zusätzliche Gefahr für den Verbraucher dar. TPs werden überwiegend mit in vitro und in vivo Techniken untersucht, welche sowohl zeit- als auch kostenintensiv sind. Ziel war es nun, schnelle und zudem verlässliche Techniken zur Simulation von TPs diverser Mykotoxine zu testen. Die Kopplung von Elektrochemie und Massenspektrometrie, kurz EC/MS, als rein instrumenteller Ansatz ist seit vielen Jahren in der pharmazeutischen Forschung etabliert. Hierbei wird mithilfe einer elektrochemischen Durchflusszelle der oxidative Metabolismus einer Substanz simuliert und zugleich analysiert.
Unter Verwendung von EC/MS, EC/LC/MS und HPLC-MS Techniken (MS/MS und FT-ICR) wurden nun die Mykotoxine Zearalenon, Citrinin und Dihydroergocristin (als Modellsubstanz für die Ergotalkaloide) elektrochemisch bei Potentialen bis zu 2500 mV vs. Pd/H2 oxidiert und deren TPs mit mikrosomalen in vitro Ansätzen verglichen. Hierbei konnten mehrere Übereinstimmungen hydroxylierter Spezies, sowohl elektrochemisch als auch biochemisch generiert, festgestellt werden. Die EC/MS ist somit auch in der Lebensmittelanalytik als nützliches und vielseitiges Werkzeug verwendbar.
Mass spectrometry is applied as a tool for the elucidation of molecular structures. This premises that gas-phase structures reflect the original geometry of the analytes, while it requires a thorough understanding and investigation of the forces controlling and affecting the gas-phase structures. However, only little is known about conformational changes of oligonucleotides in the gas phase. In this study, a series of multiply charged DNA oligonucleotides (n¼15–40) has been subjected to a comprehensive tandem mass spectrometric study to unravel transitions between different ionic gas-phase structures. The nucleobase sequence and the chain length were varied to gain insights into their influence on the geometrical oligonucleotide organization. Altogether, 23 oligonucleotides were analyzed using collision-induced fragmentation. All sequences showed comparable correlation regarding the characteristic collision energy. This value that is also a measure for stability, strongly correlates with the net charge density of the precursor ions. With decreasing charge of the oligonucleotides, an increase in the fragmentation energy was observed. At a distinct charge density, a deviation from linearity was observed for all studied species, indicating a structural reorganization. To corroborate the proposed geometrical change, collisional cross-sections of the oligonucleotides at different charge states were determined using ion mobility-mass spectrometry. The results clearly indicate that an increase in charge density and thus Coulomb repulsion results in the transition from a folded, compact form to elongated structures of the precursor ions. Our data show this structural transition to depend mainly on the charge density, whereas sequence and size do not have an influence.
Rationale: The most commonly used fragmentation methods in tandem mass spectrometry (MS/MS) are collision‐induced dissociation (CID) and higher energy collisional dissociation (HCD). While in CID the preselected ions in the trap are resonantly (and m/z exclusively) excited, in HCD the entire m/z range experiences the dissociative acceleration. The different excitation is reflected in different fragment distributions. Methods: As a test‐bed for particularly pronounced fragmentation specificity, here MS/MS experiments on several 4‐mer oligonucleotides were conducted employing both collision methods and the results were thoroughly compared. Oligonucleotides are shown to be sensitive probes to subtle changes, especially in the negative ion mode. A detailed analysis of these differences reveals insight into the dissociation mechanics. Results: Thedifferencesarerepresentedinheat‐maps,whichallowforadirectvisualinspection oflargeamountsofdata.Inthesefalsecolourrepresentationsthe,sometimessubtle,changesinthe individual dissociation product distributions become distinct. Another advantage of these graphic plots can be found in the formation of systematic patterns. These patterns reflect trends in dissociation specificity which allow for the formulation of general rules in fragmentation behavior. Conclusions: Instruments equipped with two different excitation schemes for MS/MS are today widely available. Nonetheless, direct comparisons between the individual results are scarcely made. Such comparative studies bear a powerful analytical potential to elucidate fragmentation reaction mechanism.
The quality of research antibodies is an issue for decades. Although several papers have been published to improve the situation, their impact seems to be limited. This publication makes the effort to simplify the description of validation criteria in a way that the occasional antibody user is able to assess the validation level of an immunochemical reagent. A simple, 1-page checklist is supplied for the practical application of these criteria.
2,4-D ist ein in der Landwirtschaft weitverbreitetes Pflanzenschutzmittel, das Grundwasser kontaminiert, sich innerhalb der Nahrungskette anreichert und Umwelt- und Gesundheitsprobleme verursachen kann. Hier stellen die Autoren ein mikrofluidisches Nachweissystem für die Echtzeitdetektion von 2,4-D in Grund- oder Oberflächenwasser vor. Es basiert auf der Kombination 2,4-D-selektiver, fluoreszierender, molekular geprägter Polymer-(MIP-)Mikropartikel mit einem 3D-mikrofluidischen Extraktions- und Detektionssystem. Messungen vor Ort sollen damit künftig möglich sein.
Silver nanoparticles (AgNPs), have a high scientific and commercial impact due to their important antibacterial properties. However, there are serious concerns about their toxicological adverse effects as a consequence of their broad range of applications. Particularly, the impact of AgNPs on cells is not very well understood yet and there is a current demand to develop analytical methodologies providing information about the interaction and distribution of AgNPs at a single cell level. In this research, mass cytometry was used to introduce a new quantitative approach to study the uptake of AgNPs by individual THP-1 macrophages as a cell model system. Here, we show that this methodology provides not only multi-variate phenotypic information of individual cells but enables the quantitative analysis of AgNPs associated to cells in a single measurement by performing an external calibration using AgNPs suspension. Using differentiated THP-1 cells, we monitored and quantified the uptake of 50 nm AgNPs in a time and dose-dependent manner by mass cytometry. 7 to 120 AgNPs per cell (2 to 89 fg Ag/cell) were determined after exposure of differentiated THP-1 cells to low AgNPs concentrations of 0.1 and 1.0 mg L-1, at time points of 4 and 24 h. The results were validated by mass cytometric analysis of digested cells working as a conventional inductively coupled plasma mass spectrometry, ICP-MS. This study demonstrates the power of single cell analysis by mass cytometry even for low doses experiments as a new analytical tool for hitherto unaddressed questions in nanotoxicology.
Silver nanoparticles (AgNPs), have a high scientific and commercial impact due to their important antibacterial properties. However, there are serious concerns about their toxicological adverse effects as a consequence of their broad range of applications. Particularly, the impact of AgNPs on cells is not very well understood yet and there is a current demand to develop analytical methodologies providing information about the interaction and distribution of AgNPs at a single cell level. In this research, mass cytometry was used to introduce a new quantitative approach to study the uptake of AgNPs by individual THP-1 macrophages as a cell model system. Here, we show that this methodology provides not only multi-variate phenotypic information of individual cells but enables the quantitative analysis of AgNPs associated to cells in a single measurement by performing an external calibration using AgNPs suspension. Using differentiated THP-1 cells, we monitored and quantified the uptake of 50 nm AgNPs in a time and dose-dependent manner by mass cytometry. 7 to 120 AgNPs per cell (2 to 89 fg Ag/cell) were determined after exposure of differentiated THP-1 cells to low AgNPs concentrations of 0.1 and 1.0 mg L-1, at time points of 4 and 24 h. The results were validated by mass cytometric analysis of digested cells working as a conventional inductively coupled plasma mass spectrometry, ICP-MS. This study demonstrates the power of single cell analysis by mass cytometry even for low doses experiments as a new analytical tool for hitherto unaddressed questions in nanotoxicology.
A magnetically stabilized DC arc device, designed for operation with OES spectrometers was used to determine the elements Ag, Al, B, Ba, Be, Ca, Co, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Mo, Na, Nb, Ni, Si, Sn, Sr, Ti, V, Zr at trace levels of some μg kg−1 up to some 10 mg kg−1 in graphite powders. The coil for the generation of the homogeneous magnetic field was placed outside the closed arc chamber. The time programs of variable current strengths of the magnetic coil (up to 6 A) and of the arc (up to 17 A) which was burning in air were computer controlled. Halogenating gases (mainly CCl2F2, alternatively SF6 and NF3) were used as chemical modifiers to allow an effective release of the carbide forming trace elements. The mass flow controlled modifier gas was led through a special carrier electrode near the arc plasma. The emission radiation was guided by an optical fiber alternatively into two different ICP spectrometers in which the ICP torches were removed. The synergistic interaction of the magnetic field with the halogenating modifier gases resulted in a significant improvement in the analytical performance of the optimized analytical method. All our results for 22 trace elements were in good agreement with the means of an inter-laboratory comparison by BAM for certification of a pure graphite powder material; this holds also for our results for two other graphite materials. The optimized method showed an analytical performance suitable for comprehensive trace analysis of pure graphite. The instrumentation could be integrated into modern DC arc emission spectrometers to improve their analytical capabilities substantially.
Tandem MS techniques are widely used for both, structure and sequence elucidation of biopolymers. Thereby, fragmentation activation is realized by various methods, for example with lasers or collisions with neutral gases. In this study, we present a new Tandem MS system using a commercially available vacuum ultraviolet lamp. On the one hand, this approach provides efficient fragmentation in both ionization modes, positive as well as negative. On the other hand, it enables an additional previously not achieved post ionization of the fragments. While the first results in atypical fragment patterns and, thus provides orthogonal information, the second is crucial especially to identify low abundant ions.
A versatile ionization scheme for atmospheric pressure MS is presented. It is based on a quasi-continuous laser-induced plasma (LIP), generated by a 26 kHz pulsed DPSS-laser, which is ignited in front of the MS inlet. Analytes are determined with different sampling regimes, comprising either an ambient desorption/ionization mechanism, a liquid-phase or gas-phase sample introduction.
The MS signal closely resembles the ionization behavior of APCI-like plasma-based sources, such as DBD or DART. Though LIPs are known to efficiently atomize/ionize any sample material, mass spectra of intact molecular ions are recorded, exhibiting low fragment-ion content. To understand this contradictory behavior, the plasma properties are investigated that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraph imaging and mass spectrometry diagnostics.
The results show that the ionization of analyte does not occur in the plasma itself, but in the cold adjacent gas layer. The pulsed character of LIPs induces an expanding shockwave, which concentrically expands around the plasma core and sweeps the molecules toward the plasma edges, where they are ionized either directly by the self-emission of the hot core or via interaction with secondary reactants. However, this unidirectional transport causes a rarefaction inside the plasma center, which leads to a decrease in plasma intensity and number density. Thus, a restoration of the former gaseous medium by other dynamically equilibrated diffusion processes would be favorable. Besides gas replenishing, we demonstrate the beneficial use of an acoustical standing wave inside an ultrasonic resonator on the performance of the LIP.
The development and enhancement of new ionization techniques for mass spectrometry often needs to be custom-tailored for specific sampling approaches. Here, a direct sampling ionization technique is presented for ambient mass spectrometry. Ambient mass spectrometry based techniques are typically used to analyze samples in their native states without sample pretreatment. This new design is based on a quasi-continuous airborne plasma which is ignited inside the particulate air via a focused laser irradiation. Desorption and ionization of the analyte molecules are achieved by the laser plasma without reaching the plasma. The ionization process is induced by interaction with nascent ionic fragments, electrons and ultraviolet photons in the plasma vicinity. Previously, this method was solely used for the characterization of solid and gaseous analytes. The sample introduction was occurred via thermal desorption and headspace analysis. This study focuses on the potential applicability of liquid samples. In comparison to previous approaches, the usage of liquid samples has an impact on the stability of typically used plasma of 532 nm. It was necessary to realize an alternative plasma using light of the fundamental wavelength of 1064 nm. That new plasma resulted in a significant more stable and bright plasma and the first laser plasma ionization spectrum was recorded for an analyte in the condensed phase with a mass spectrometer of type LCQ DecaXP.
Online coupling of electrochemistry with mass spectrometry (EC/MS) is highly promising for prediction and simulation of metabolic processes of xenobiotics in living organisms. Less time and cost of analysis, matrix free detection, and automation make EC/MS-based metabolomics superior over traditional in-vivo and in-vitro methods. Furthermore, EC/MS has a special feature to identify reactive intermediates and reaction mechanisms.
The main objective of this work was to simulate biotransformation processes of pesticides by EC/MS and to elucidate the Transformation products (TPs). We have studied the oxidative phase I metabolism processes of selected pesticides by EC/MS or with liquid chromatography (EC/LC/MS) and compared the derived TPs with cytochrome based metabolites. The electrochemical TPs were produced by boron-doped diamond electrode, separated by LC, and detected by single quadrupole ESI-MS online. Structural identification of both electrochemical oxidation and liver microsome metabolites were based on accurate mass measurements by FT-ICR high-resolution mass spectrometry, isotopic pattern, MS/MS fragmentation, and Retention time alignments.
Main phase I oxidative metabolites by P-oxidation, N- & O- dealkylation, dechlorination, hydroxylation, and -OH- oxidation have been identified. Many targeted and untargeted metabolites have been identified by EC/(LC)/MS. Additionally, reactive species have been trapped online by biomolecules to study phase II conjugative reactions. Furthermore, we synthesized TP standards by EC/MS and applied them for pesticide's TPs occurrence investigation in foodstuf matrices.
Singlet oxygen generation potential of two novel free-base-porphyrin photocatalysts was investigated. The freebase-porphyrin-sensitized Fe3O4 magnetic nanoparticles (MNPs) were tested for the degradation of the model pollutant Bisphenol A (BPA) in aqueous solution, for the first time. MNPs with either cubic or spherical shape were synthesized using the sonochemical approach, followed by sensitizing with photoactive 4,4′,4′′,4′′′- (Porphine-5,10,15,20-tetrayl)tetrakis(benzoic acid) (TCPP). The resulted photocatalysts were characterized in detail by scanning and transmission electron microscopy, Brunauer–Emmett–Teller analysis, spectral techniques and vibrating sample magnetometry. The electron spin resonance experiments have confirmed the high activity of the photocatalysts through the efficient formation of singlet oxygen in solution. The optimum operational parameters for BPA degradation were established as follows: 1.0 μmol L−1 BPA, 1.0 g L−1 of photocatalyst, 100 μmol L−1 H2O2, under UVA irradiation. In these conditions, the results for both photocatalysts revealed that after only 10 min of reaction, over 64% and ca. 90% of BPA have been removed from solution in the absence and presence of H2O2, respectively. Whereas after 60 minutes of treatment, only 24% of BPA in real wastewater effluent samples were removed under UVA irradiation in the absence of H2O2, showing the high complexity of real wastewater. Moreover, both photocatalysts were successfully used for BPA removal in three consecutive runs, without significant loss of catalytic features.
Alternariol (AOH) and Alternariol monomethylether (AME) are two secondary metabolites of Alternaria fungi which can be found in various foodstuffs like tomatoes, nuts and grains. Due to their toxicity and potential mutagenic activity the need for the development of high-throughput methods for the supervision of AOH- and AME-levels is of increasing interest. As the availability of both native and labelled AOH and AME analytical standards is very limited we herein wish to present a novel concise approach towards their synthesis employing a ruthenium-catalyzed ortho-arylation4 as the key step.
In this work we report a novel paper-based analytical device read-out via LED-induced fluorescence detection (FPAD) for the quantification of the emerging pollutant ethinylestradiol (EE2) in river water samples. The PAD was used as a reaction platform for a competitive enzyme immunoassay. For the PAD development, microzones of filter paper, printed by a wax printing method, were modified with amino-functionalized SBA-15 and subsequently, anti-EE2 specific antibodies were covalently immobilized. The determination of EE2 in water was
carried out by adding a fixed concentration of EE2 conjugated with the enzyme horseradish peroxidase (HRP) to samples and standards. Then, the FPAD were added and incubated for 10 min. Finally, the detection was performed by the reaction of 10-acetyl-3,7-dihydroxyphenoxazine (ADHP) whose oxidation is catalyzed by HRP in the presence of H2O2, obtaining the highly fluorescent resorufin (R). Resorufin was detected by LED excitation at 550 nm, observing emission at 585 nm. The EE2 concentration in the samples was inversely proportional to the relative fluorescence obtained from the enzymatic reaction products. The FPAD assay showed a detection Limit (LOD) of 0.05 ng L−1 and coefficients of variation (CV) below 4.5% within-assay and below 6.5% between-assay, respectively. The results obtained show the potential suitability of our FPAD for the selective and sensitive quantification of EE2 in river water samples. In addition, it has the PADs advantages of being disposable, easy to
apply and inexpensive.
The talk introduces the technique of LC-ELISA: fractionating pre-concentrated water samples, analyzing them for containing compounds that bind to hapten-selective antibodies followed by high-Resolution mass spectrometry non-target analysis of "positive" fractions for Transformation products of emerging organic contaminants.
A novel technique based on laser induced plasma imaging is proposed to measure residual pressure in sealed containers with transparent walls, e.g. high voltage vacuum interrupter in this paper. The images of plasma plumes induced on a copper target at pressure of ambient air between 10−2Pa and 105Pa were acquired at delay times of 200ns, 400ns, 600ns and 800ns. All the plasma images at specific pressures and delay times showed a good repeatability. It was found that ambient gas pressure significantly affects plasma shape, plasma integral intensities and expansion dynamics. A subsection characteristic method was proposed to extract pressure values from plasma images. The method employed three metrics for identification of high, intermediate and low pressures: the distance between the target and plume center, the integral intensity of the plume, and the lateral size of the plume, correspondingly. The accuracy of the method was estimated to be within 15% of nominal values in the entire pressure range between 10−2Pa and 105Pa. The pressure values can be easily extracted from plasma images in the whole pressure range, thus making laser induced plasma imaging a promising technique for gauge-free pressure detection.
Die Bundesanstalt für Materialforschung und -prüfung (BAM) ist eine Ressortforschungseinrichtung, die zum Schutz von Mensch, Umwelt und Sachgüter, forscht, prüft und berät. Im Fokus aller Tätigkeiten in der Materialwissenschaft, der Werkstofftechnik und der Chemie steht dabei die technische Sicherheit von Produkten und Prozessen. Dazu werden Substanzen, Werkstoffe, Bauteile, Komponenten und Anlagen sowie natürliche und technische Systeme erforscht und auf sicheren Umgang oder Betrieb geprüft und bewertet. Schwerpunkt des Vortrages sind multimodale Polymeranalytik, nanoskalige Sensormaterialien und die Charakterisierung von technischen Eigenschaften von Polymeren sowie ihre Alterung und Umweltrelevanz.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining importance for bioimaging cytometry to answer analytical, biological and biomedical questions. High sensitivity and spatial resolution make it an excellent tool for imaging of metal and heteroelement distribution in single cells. Comparable to CyTOF imaging mass cytometry, metal coded antibodies can be used for multiparametric analysis as well as quantification.
In this project, nanocrystals are investigated as new highly sensitive metal tags for identification and quantification of biomarkers, like Alzheimer’s or breast cancer, in clinical cell assays and tissue samples. Of high significance is the simultaneous analysis of several biomarkers at once, which is possible by special coding of lanthanide tags on the biomarker associated antibody. Nanocrystals show potential for sensitive measurement in MS due to high stability and signal amplification compared to tags with fewer metal atoms. For proof of principle, synthesis and characterization of lanthanide doped nanocrystals was performed by a nanoPET pharma GmbH with great reproducibility and homogenous size. In A549 cell cultures, the uptake and distribution of these nanocrystals within the monolayered cells was investigated by LA-ICP-MS measurements using subcellular resolution. The nanocrystals showed high sensitivity and the possibility of multiparametric analysis by doting different lanthanides. Additionally, stability of the bioconjugation of the nanocrystals and target antibodies was investigated using Dot Blot experiments and LA-ICP-MS.
Development and market introduction of new nanomaterials trigger the need for an adequate risk assessment of such products alongside suitable risk communication measures. Current application of classical and new nanomaterials is analyzed in context of regulatory requirements and standardization for chemicals, food and consumer products. The challenges of nanomaterial characterization as the main bottleneck of risk assessment and regulation are presented. In some areas, e.g., quantification of nanomaterials within complex matrices, the establishment and adaptation of analytical techniques such as laser ablation inductively coupled plasma mass spectrometry and others are potentially suited to meet the requirements. As an example, we here provide an approach for the reliable characterization of human exposure to nanomaterials resulting from food packaging. Furthermore, results of nanomaterial toxicity and ecotoxicity testing are discussed, with concluding key criteria such as solubility and fiber rigidity as important parameters to be considered in material development and regulation. Although an analysis of the public opinion has revealed a distinguished rating depending on the particular field of application, a rather positive perception of nanotechnology could be ascertained for the German public in general. An improvement of material characterization in both toxicological testing as well as end-product control was concluded as being the main obstacle to ensure not only safe use of materials, but also wide acceptance of this and any novel technology in the general public.
Single-cell analysis by ICP-MS/MS as a fast tool for cellular bioavailability studies of arsenite
(2018)
Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) has become a powerful and fast tool to evaluate the elemental composition at a single-cell level. In this study, the cellular bioavailability of arsenite (incubation of 25 and 50 μM for 0-48 h) has been successfully assessed by SC-ICP-MS/MS for the first time directly after re-suspending the cells in water. This procedure avoids the normally arising cell membrane permeabilization caused by cell fixation methods (e.g. methanol fixation). The reliability and feasibility of this SC-ICP-MS/MS approach with a limit of detection of 0.35 fg per cell was validated by conventional bulk ICP-MS/MS analysis after cell digestion and parallel measurement of sulfur and phosphorus.
During cancer radiation therapy high‐energy radiation is used to reduce tumour tissue. The irradiation produces a shower of secondary low‐energy (<20 eV) electrons, which are able to damage DNA very efficiently by dissociative electron attachment. Recently, it was suggested that low‐energy electron‐induced DNA strand breaks strongly depend on the specific DNA sequence with a high sensitivity of G‐rich sequences. Here, we use DNA origami platforms to expose G‐rich telomere sequences to low‐energy (8.8 eV) electrons to determine absolute cross sections for strand breakage and to study the influence of sequence modifications and topology of telomeric DNA on the strand breakage. We find that the telomeric DNA 5′‐(TTA GGG)2 is more sensitive to low‐energy electrons than an intermixed sequence 5′‐(TGT GTG A)2 confirming the unique electronic properties resulting from G‐stacking. With increasing length of the oligonucleotide (i.e., going from 5′‐(GGG ATT)2 to 5′‐(GGG ATT)4), both the variety of topology and the electron‐induced strand break cross sections increase. Addition of K+ ions decreases the strand break cross section for all sequences that are able to fold G‐quadruplexes or G‐intermediates, whereas the strand break cross section for the intermixed sequence remains unchanged. These results indicate that telomeric DNA is rather sensitive towards low‐energy electron‐induced strand breakage suggesting significant telomere shortening that can also occur during cancer radiation therapy.
2-Amino-2-(hydroxymethyl)-1,3-propanediol (TRIS) and ethylene-diaminetetraacetic acid (EDTA) are key components of biological buffers and are frequently used as DNA stabilizers in irradiation studies. Such surface or liquid phase studies are done with the aim to understand the fundamental mechanisms of DNA radiation damage and to improve cancer radiotherapy. When ionizing radiation is used, abundant secondary electrons are formed during the irradiation process, which are able to attach to the molecular compounds present on the surface. In the present study we experimentally investigate low energy electron attachment to TRIS and methyliminodiacetic acid (MIDA), an analogue of EDTA, supported by quantum chemical calculations. The most prominent dissociation channel for TRIS is through hydroperoxyl radical formation, whereas the dissociation of MIDA results in the formation of formic and acetic acid. These compounds are well-known to cause DNA modifications, like strand breaks. The present results indicate that buffer compounds may not have an exclusive protecting effect on DNA as suggested previously.
Multidimensional high throughput methods for the analysis of particle-based peptide libraries
(2018)
Screening of one-bead-one-peptide libraries is a useful procedure for the identification of protein ligands. The demand for binders with high affinity and high specificity towards various target proteins has surged in the biomedical field in the recent years. The 1 traditional peptide screening procedure involves tedious steps as selection, sequencing, and characterization. Herein, we developed a high-throughput – “all in one chip” system to avoid time-consuming separation steps.
Screening of one-bead-one-peptide libraries is a useful procedure for the identification of protein ligands. The demand for binders with high affinity and high specificity towards various target proteins has surged in the biomedical field in the recent years. The traditional peptide screening procedure involves tedious steps as selection, sequencing, and characterization. Herein, we developed a high-throughput – “all in one chip” system to avoid time-consuming separation steps.
Online immunocapture ICP‑MS for the determination of the metalloprotein ceruloplasmin in human serum
(2018)
The human copper-protein ceruloplasmin (Cp) is the major copper-containing protein in the human body. The accurate determination of Cp is mandatory for the reliable diagnosis of several diseases. However, the analysis of Cp has proven to be difficult. The aim of our work was a proof of concept for the determination of a metalloprotein-based on online immunocapture ICP-MS. The immuno-affinity step is responsible for the enrichment and isolation of the analyte from serum, whereas the compound-independent quantitation with ICP-MS delivers the sensitivity,
precision, and large dynamic range. Off-line ELISA (enzyme-linked immunosorbent assay) was used in parallel to confirm the elution profile of the analyte with a structure-selective method. The total protein elution was observed with the 32S mass trace. The ICP-MS signals were normalized on a 59Co signal. The human copper-protein Cp could be selectively determined. This was shown with pure Cp and with a sample of human serum. The good correlation with off-line ELISA shows that Cp could be captured and eluted selectively from the anti-Cp affinity column and subsequently determined by the copper signal of ICP-MS.
Hepcidin-25 has attracted much attention ever since its discovery in 2001. It is widely recognized that this peptide hormone plays a major role in the regulation of iron levels in mammals and can reveal important clinical information about several iron-related disorders. However, the development of a reliable assay to quantify hepcidin proved to be problematic and serum hepcidin-25 concentrations determined by various assays differ substantially. Challenges arise in the MS analysis of hepcidin due to the “sticky” character of the peptide and the lack of suitable standards.
With the aim to tackle the current difficulties in hepcidin quantification and improve the status of this promising biomarker in the clinical field, we developed a rapid and robust analytical strategy for the quantification of hepcidin-25 in human samples based on HPLC-MS/MS (QqQ) as a reference method candidate to be implemented in routine laboratories. The novelty of the method is the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces. Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions where the use of acidic mobile phases was compared with a novel approach involving solvents at high pH containing 0.1% of ammonia. Both methods were carefully validated and applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with very good correlation of the results.
The spectroscopic characterization by surface-enhanced Raman scattering (SERS) has shown great potential in studies of heterogeneous catalysis. We describe a plug-in multifunctional optofluidic platform that can be tailored to serve both as a variable catalyst material and for sensitive optical characterization of the respective reactions using SERS in microfluidic systems. The platform enables the characterization of reactions under a controlled gas atmosphere and does not present with limitations due to nanoparticle adsorption or memory effects. Spectra of the gold-catalyzed reduction of p-nitrothiophenol by sodium borohydride using the plug-in probe provide evidence that the borohydride is the direct source of hydrogen on the gold surface, and that a radical anion is formed as an intermediate. The in situ monitoring of the photoinduced dimerization of p-aminothiophenol indicates that the activation of oxygen is essential for the plasmon-catalyzed oxidation on gold nanoparticles and strongly supports the central role of metal oxide species.
We report a novel and innovative electrochemical paper-based immunocapture assay (EPIA) to address the need for ultrasensitive detection of emerging pollutants without regulatory status and whose effects on environment and human health are not completely yet understood. In particular, we present the application of this system toward highly sensitive detection of the emerging pollutant ethinyl estradiol (EE2). The EPIA approach is based on the use of paper microzones modified with silica nanoparticles (SNs) and anti-EE2 specific antibodies for capture and preconcentration of EE2 from river water samples. After the preconcentration procedure, the paper microzones are placed onto a screen-printed carbon electrode modified with electrochemically reduced graphene (RG). The bound EE2 is subsequently desorbed adding a diluted solution of sulfuric acid on the paper microzones. Finally, recovered EE2 is electrochemically detected by OSWV. The proposed novel methodology showed an appropriate LOD and linear range for the quantification of EE2 for water samples with different origins. The nonsophisticated equipment required, the adequate recovery values obtained (from 97% to 104%, with a RSD less than 4.9%), and the appropriate LOD and linear range value (0.1 ng L−1 and 0.5−120 ng L−1, respectively) achieved by our immunocapture sensor present significant analytical figures of merit, particularly when the routine quantification of EE2 is considered. In addition, our System was based on electrochemical paper-based technology, which allows obtainment of portable, easy-to-use, inexpensive, and disposable devices. The EPIA can also serve as a general-purpose immunoassay platform applicable to quantitation of other drugs and emerging pollutants in environmental samples.
A vast number of emerging pollutants has been detected in the environment over the last decades. Analytical methods suitable for trace analysis are needed that are desirably also fast, inexpensive and, if possible, robust and portable. Immunoanalytical methods which are available in a broad range of formats, can be profitably used here to analyze for the distribution and the trends of concentration levels of contaminants in the environment. Some of these formats are single-analyte but high-throughput methods. In order to use them wisely, indicator substances, sometimes called anthropogenic markers, should be selected and used in screening approaches. Other methods are suitable to be performed on portable instrumentation in the field (on-site) or in facilities such as wastewater treatment plants for on-line monitoring. Furthermore, there are the socalled array technologies that allow for parallel analysis of several analytes of interest (multiplexing). The microtiter-plate based ELISA (Enzyme-linked Immunosorbent Assay) is the method of choice for the analysis of a large number of samples [1]. ELISA screening data for anthropogenic markers such as the antiepileptic carbamazepine, the analgesic diclofenac, the anti-histaminic cetirizine, the steroid hormone estrone, the antimicrobial sulfamethoxazole, the stimulants caffeine and cocaine, the priority pollutant bisphenol A, and the bile acid isolithocholic acid [2] are presented. For on-site screening and monitoring, simpler formats, like mix-and-read assays, e.g. the Fluorescence Polarization Immunoassay (FPIA) or Lateral-flow Immunoassays (LFIA) are more suitable tools. Electrochemical formats run on portable devices provide additional advantages as no light source is required. Some examples are presented and discussed. The suitability of multi-analyte formats such as immunomicroarrays depends on the choice of a signal-producing system that provides small uncertainties and good reproducibility of the measurements. Biochip (“flat”) arrays read out on slide scanners and bead-based (“suspension”) arrays read out in flow cytometers are two options and show their distinct pros and cons. Altogether these approaches show the great potential immunoanalytical methods provide for the screening for environmental contaminants in the aquatic environment.