Absorption edge tomography, also known as differential tomography at absorption edges, is a method which exploits the sudden change of the attenuation coefficient, when the photon energy crosses the absorption edge of an element. Synchrotron radiation is the best source for absorption edge tomography, because of its small bandwidth, high intensity and easily adjustable photon energy. The synchrotron beamline BAMline at the synchrotron radiation facility BESSY II in Berlin, which is operated by the Bundesanstalt für Materialforschung und -prüfung (BAM), provides a monochromatized beam in a photon energy range from 5 keV up to 80 keV with a bandwidth of 2%, when the double multilayer monochromator is used. Together with the microtomography setup, this enables differential tomography with submicron resolution at the K edge of the elements from chromium up to the lanthanides, and up to uranium, when the L edges are used as well.
In this work, metal organic frameworks (MOFs) embedded in polymer are characterized using differential tomography. MOFs are microporous structures of metal ions, coordinated by organic linker molecules, that can be used in a broad field of applications, especially in gas storage and catalysis. In this work, polymer embedded MOFs were extruded into filaments, which could be used for 3d-printing to profit from the specific properties of the MOFs in polymeric materials combined with the arbitrary shapes provided by 3d-printing. For the extrusion, different polymer classes like ABS, polyester- and polyetherurethanes, as well as different MOFs (ZIF-8, ZIF-67, HKUST-1) were used to create MOF containing filaments with a nominal diameter of 3.0 mm. Differential tomography at the edges of the Zn, Co, and Cu was then used to find the distribution of the corresponding MOF in the filament and to analyze the shape of the inclusions.
After a general presentation of the beamline, specifically the workflow for ex-situ CT at BAMline is presented. Although being used in a broad variety of research fields the usual workflow for CT experiments is in most cases similar in terms of sample mounting, tomographic scan and reconstruction. Specific scanning schemes allow for a preview reconstruction carried out during the scan. A detailed description of the used hardware as well as the self-coded programs applied in the data pipeline will be given. This will be accompanied by a practical demonstration of the software involved in the entire process.
After a general presentation of the beamline, specifically the workflow for ex-situ CT at BAMline is presented. Although being used in a broad variety of research fields the usual workflow for CT experiments is in most cases similar in terms of sample mounting, tomographic scan and reconstruction. Specific scanning schemes allow for a preview reconstruction carried out during the scan. A detailed description of the used hardware as well as the self-coded programs applied in the data pipeline will be given. This will be accompanied by a practical demonstration of the software involved in the entire process.