Classical film radiography is a well-established NDT technique and it is most commonly used for testing weld seams and corroded pipes e.g. in oil and gas industry or in nuclear power plants. In the course of digitization, digital detector arrays (DDA) are finding their way into industrial applications and are replacing film radiography step by step. This study deals with the latest generation of DDAs, the photon counting and energy resolving detectors (PCD), and their characteristics compared to charge integrating detectors (CID). No matter which technology to use, radiography still lacks a general issue: A three-dimensional object is projected onto a two dimensional image. Of course, advanced computed tomography (CT) algorithms exist since many years, but if the object to investigate is too large to fit into the manipulation system or its shape is not appropriate, CT is not feasible or sensible to be applied. To overcome this limitation, numerous laminographic algorithms have been developed in the past. In this study, photon counting detectors are used in combination with co-planar translational laminography to gain reconstructed three-dimensional volumes. Both laminographic testing and PCDs require a serious knowledge of many parameters that can influence the image quality in the resulting datasets. These are e.g. the detector efficiency and calibration procedure, setting of energy thresholds, exposure data, number of projections, beam length correction and spatial resolution. The use of PCDs yields more variables to be considered compared to CIDs. The most important parameters in laminographic testing and in the use of PCDs are described in this study and limits are discussed.
Today, it is an established fact that the capability of the non-destructive testing (NDT) to find flaws can be properly addressed only in terms of probability of detection (POD). The probabilistic, signal-response model, introduced in 1980s, was developed with experimental observation of eddy-current inspections of flat plate samples, containing surface breaking cracks. A linearity between the peak voltage measured by the testing system, and the crack depth was observed. The influence of the crack depth was therefore seen as the major influencing factor for the POD, whereas other factors merely caused the variability in the measurement. This model has proven itself valid for those inspection cases where there is only one main influencing factor on the POD (usually the flaw size) and other factors have a lesser influence. But with increasing requirements to quantify the capability of NDT systems in complex inspection situations, where several factors have a major influence on the POD, it has become clear that the applicability of this simple model has reached its limits. In disregard to its limitations, this model is regularly applied to those situations in which its fundamental assumptions are invalid, forcing evaluators and NDT researchers into attempts to fit the data to an unsuitable model, instead of fitting an appropriate model to the data.
The multiparameter POD model, developed in the early 2010s, enables more factors that influence detection to be simultaneously analysed, making the POD a function of multiple factors. The model is based on the inspection’s physical model, to describe the influence of different factors on the response signal. Measurement variability is obtained from the experiment. Using this model assisted determination of the POD, the necessary number of flaws for evaluation is reduced and a more comprehensive understanding of the inspection is obtained. Several examples of the successful application of the multi-parameter POD model in different fields will be presented.
The vast experience with the automated, ultrasonic system for the inspection of hollow railway axles used by Deutsche Bahn shows that much smaller flaws are detectable than required. This results in a number of false calls. False calls lead to unnecessary demounting and disassembling of wheelsets, which generates unnecessary additional costs. In order to adjust the sensitivity of the inspection system to reduce the number of false calls without compromising safety, the capability of the system to detect cracks needs to be comprehensively established. This capability can be quantified by using probability of detection (POD) curves for the system. The multi-parameter POD model makes it possible to include several factors that influence the crack detection in the analysis. The analysis presented in this paper shows that crack position, orientation, depth extension, and shape as well as the geometry of the axle all have influence on the ultrasonic response amplitude. For future work, calculation of the POD using multi-parameter POD model with these parameters is planned.