Analytische Chemie
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (2) (entfernen)
Sprache
- Englisch (2)
Referierte Publikation
- nein (2)
Schlagworte
- Concrete (2) (entfernen)
Organisationseinheit der BAM
The LAUS: First Applications of a New System for Ultrasonic Imaging of Very Concrete Structures
(2019)
The LAUS (Large Aperture Ultrasonic System) has been developed to image very thick concrete structures, which are not accessible for commercial systems. The device and the corresponding software is the result of joint Research of BAM, an ultrasonic instrument manufacturer and University of Kassel, Germany. It consists of 12 separate Arrays of 32 point-contact shear wave transducers each, which can be deployed in flexible configurations. Each array is combined with battery and transmitter, receiver and wireless communication electronics.
Three case histories are presented. First the system was deployed on a 5-m thick heavily reinforced foundation slab.
The reflection of the slab’s bottom was imaged clearly. In addition, a multiple reflection was registered, thus giving hope that even thicker elements might be imaged by the instrument. Second, the LAUS was used to investigate a massive bridge girder where a heavy rainstorm during concreting had led to imperfections that were visible after removing the formwork was removed. The LAUS could image tendon ducts in 1.8m depth and the backwall closely behind them. Some limited areas showed blurred reflections and were checked by drill holes; these areas were affected by diffuse damage which could be repaired by injections. Third, a large retaining wall was checked for thickness.
Meanwhile, the LAUS has been used in underground waste deposits (nuclear and other) for quality assurance of sealing plugs. A confirmed penetration depth of about 7 m has been reached.
Laser-induced breakdown spectroscopy (LIBS) is a combination of laser ablation and optical emission spectroscopy. Due to the possibility of direct measurements on the sample surface with a minimum of sample preparation investigations of building materials can be conducted quite fast. In combination with a scanning technique (translation stage or scanning mirrors head) 2D element distributions of harmful species like chlorides and alkalis are evaluated with a sub-mm resolution. By scanning a surface of typically 100 mm x 100 mm the heterogeneity of the material may be considered. LIBS is capable to identify hot spots in element concentration with a resolution of 0.1 mm or even smaller. A LIBS-system for the on-site application on building materials is, in cooperation with system developers and companies which will use this technique for investigation on real structures, under test at BAM. We present an example. Further work will focus on providing guidelines to establish LIBS as a standard procedure for chemical investigations of building materials.