Analytische Chemie
Filtern
Dokumenttyp
Schlagworte
- Ferroelectret (5)
- Air-coupled (3)
- Thermoacoustic (2)
- Transducer (2)
- Ultrasonic (2)
- Ultrasonic transducer (2)
- Acoustic sensors (1)
- Airborne (1)
- Cellular polypropylene (1)
- Focusing (1)
Organisationseinheit der BAM
High sensitivity is an important requirement for air-coupled ultrasonic sensors applied to materials testing. With a lower acoustic impedance than any piezoelectric material, charged cellular polypropylene (PP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric properties of charged cellular PP originate from their polarization, creating permanent internal voltage. The sensitivity of the sensor can be increased by applying additional dc bias voltage, as it has been done already for transmitters. This work presents the first ultrasonic sensor based on charged cellular PP including a high-voltage module providing dc bias voltage up to 2 kV. This bias voltage led to an increase in the signal-to-noise ratio of up to 15 ± 1 dB. The measurement of the received signal depending on the applied bias voltage is proposed as a new method of determining the internal voltage of ferroelectrets. The sensor combined with a cellular PP transmitter was applied to nondestructive testing of a rotor blade segment and glued-laminated timber, enabling imaging of the internal structure of these specimens with a thickness around 4 cm.
Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio.
Novel air-coupled ultrasonic transducer combining the thermoacoustic with the piezoelectric effect
(2016)
In recent years, there has been an increasing industrial demand for one-sided inspection of various structures by means of air-coupled ultrasonic technique. Lightweight structures based on carbon-fibre-reinforced polymers may have very complex shapes, making air-coupled transmission difficult or even impossible. The inspection of concrete structures is another example where one-sided inspection is required.
To address these challenges a new type of transducer for air-coupled pulse-echo inspection was developed, which unites two principles: thermoacoustic emission and piezoelectric reception. The thermoacoustic emitter is a titanium electrode with a thickness of several tens of nanometer. This electrode was deposited onto charged cellular polypropylene, which serves as a piezoelectric receiver. The thermoacoustic transmission is based on a transformation of the thermal energy of an electrically heated electrode into the acoustic energy of an ultrasonic wave. Thermoacoustic emitters provide resonance-free behaviour and thus extremely broadband pulses. Charged cellular polypropylene is piezoelectric due to the polarization of its cells and it is well matched to air, with a Young modulus in the order of magnitude of MPa. In this contribution we present some pulse-echo measurements with the first prototypes of the combined thermoacoustic-piezoelectric transducer.
Air-coupled ultrasound has been applied increasingly as a non-destructive testing method for lightweight construction in recent years. It is particularly appropriate for composite materials being used in automotive and aviation industry. Air-coupled ultrasound transducers mostly consist of piezoelectric materials and matching layers. However, their fabrication is challenging and their signal-to-noise ratio often not sufficient for many testing requirements. To enhance the efficiency, air-coupled ultrasound transducers made of cellular polypropylene have been developed. Because of its small density and sound velocity, this piezoelectric ferroelectret matches the small acoustic impedance of air much better than matching layers applied in conventional transducers. In our contribution, we present two different methods of spherical focusing of ferroelectret transducers for the further enhancement of their performance in NDT applications. Measurements on carbon-fiber-reinforced polymer (CFRP) samples and on metal adhesive joints performed with commercially available focused air-coupled ultrasound transducers are compared to measurements executed with self-developed focused ferroelectret transducers.
Airborne ultrasonic inspection is performed in through transmission, where the test piece (e.g. adhesive joint or polymer-based composite plate) is placed between the transmitter and the receiver. However, many structures with difficult shapes allow only one-sided inspection. The strong reflection of the signal from the surface overshadows the signals from the inside, so that broadband pulses are required. Thermoacoustic transmission, where the thermal energy of an electrically heated electrode is transformed into the acoustic energy of an ultrasonic wave, opens the possibility to excite broadband pulses and thus to inspect objects with one-sided access.
We present various thermoacoustic transducers consisting of an electrically conductive film on a solid substrate. The first type of transducer is a transmitter with an indium-tin-oxide electrode on a glass substrate combined with a laser Doppler vibrometer as a receiver. The second type of transducer combines thermoacoustic transmission and piezoelectric reception, having a titanium electrode as a transmitter deposited onto charged cellular polypropylene serving as a piezoelectric receiver.
Using a focusing thermoacoustic transmitter and a separate cellular polypropylene receiver, a through-transmission inspection of a 4 mm thick CFRP test piece with inserts as small as 1 mm was performed. The same emitter and a laser vibrometer as a receiver were used for a one-sided inspection of a Plexiglas block with a cross hole at 15 mm depth. A twin probe consisting of a thermoacoustic transmitter on a cellular polypropylene receiver was applied to a profile measurement on a step wedge with flat bottom holes. The smallest detected diameter of a flat bottom hole was 1 mm. Sound pressure level above 140dB was achieved with each of these transmitters. Thermoacoustic transmitters enable a step towards one-sided air-coupled ultrasonic inspection.
Für die Prüfung von Leichtbaustrukturen ist in den letzten Jahren ein vermehrter Einsatz der Luftultraschallprüfung zu verzeichnen. Insbesondere eignet sich Luftultraschall für die Prüfung von Faserkunststoffverbunden und hybrider Werkstoffverbunde, die ihre Anwendung in der Automobilindustrie und Luftfahrt finden. Für den Bau von marktüblichen Luftultraschall-Wandlern werden Piezokomposite mit Anpassschichten versehen. Ihre Herstellung ist allerdings sehr anspruchsvoll und die erreichbaren Signal-Rausch-Abstände sind für viele Prüfprobleme als noch nicht ausreichend einzustufen. Zwecks gesteigerter Effizienz beim Schallübertrag in die Luft wurden Luftultraschall-Sender und -Empfänger aus zellulärem Polypropylen entwickelt. Dieses piezoelektrische Material ist aufgrund seiner geringer Dichte und seiner sehr geringen Schallgeschwindigkeit an die niedrige akustische Impedanz der Luft deutlich besser angepasst, als die üblicherweise verwendeten Anpassschichten. Letztere können bei Polypropylen-Wandlern daher gänzlich vermieden werden.
In diesem Beitrag wird Luftultraschall-Prüfung an zwei verschiedenen CFK-Testkörpern vorgestellt: an einer Platte mit T-Stringern aus dem Seitenleitwerk eines Flugzeugs und an einer Platte mit künstlich eingebrachten Fehlern. Es wurde mit unterschiedlichen planaren und fokussierenden Wandlern geprüft. Marktübliche Wandler mit Anpassschichten wurden mit den selbstentwickelten Wandlern aus zellulärem Polypropylen verglichen. Der Signal-Rausch-Abstand und die laterale Auflösung wurden sowohl im Prüfaufbau mit senkrechter Einschallung als auch mit Schrägeinschallung gemessen. Die Ergebnisse zeigen, dass die Schrägeinschallung zwar den Signal-Rauschabstand erhöht, aber die laterale Auflösung verschlechtern kann.