Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (238)
- Deutsch (1)
- Mehrsprachig (1)
Schlagworte
- Fluorescence (240) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (169)
- 1.2 Biophotonik (113)
- 1.9 Chemische und optische Sensorik (45)
- 6 Materialchemie (11)
- 1.5 Proteinanalytik (9)
- 1.1 Anorganische Spurenanalytik (7)
- 6.1 Oberflächen- und Dünnschichtanalyse (6)
- 1.7 Organische Spuren- und Lebensmittelanalytik (5)
- 6.3 Strukturanalytik (5)
- 1.0 Abteilungsleitung und andere (4)
Paper des Monats
- ja (3)
Eingeladener Vortrag
- nein (65)
This paper reflects recent progress in the field of fluorescent polymer optical fiber sensors (F-POF) for partial discharge (PD) detection in high voltage (HV) cable accessories using optical-only PD detection by coincidence single photon counting. In experiments with artificial PD sources these sensors show the ability to detect optical emissions from picocoulomb-level PDs in a real-scale model of a translucent high voltage cable accessory. False positives (caused by detector noise) are efficiently suppressedwhile maintaining sufficient sensitivity,even when the sensor is located in an unfavorable position.
The synthesis of water-soluble dyes, which absorb and emit in the range between 650 and 950 nm and display high extinction coefficients (ε) as well as high fluorescence quantum yields (Φf), is still a demand for optical imaging. We now present a synthetic route for the preparation of a new group of glycerol-substituted cyanine dyes from dendronized indole precursors that have been functionalized as Nhydroxysuccinimide (NHS) esters. High Φf values of up to 0.15 and extinction coefficients of up to 189 000 L mol−1 cm−1 were obtained for the pure dyes. Furthermore, conjugates of the new dendronized dyes with the antibody cetuximab (ctx) that were directed against the epidermal growth factor receptor (EGFR) of tumor cells could be prepared with dye to protein ratios between 0.3 and 2.2 to assess their potential as imaging probes. For the first time, ctx conjugates could be achieved without showing a decrease in Φf and with an increasing labeling degree that exceeded the value of the pure dye even at a labeling degree above 2. The incorporation of hydrophilically and sterically demanding dendrimers into cyanines prevented dimer formation after covalent conjugation to the antibody. The binding functionality of the resulting ctx conjugates to the EGFR was successfully demonstrated by cell microscopy studies using EGFR expressing cell lines. In summary, the combination of hydrophilic glycerol dendrons with reactive dye labels has been established for the first time and is a promising Approach toward more powerful fluorescent labels with less dimerization.
Here, we summerize our efforts concerning new design concepts and examples for fluorescence standards that can provide traceability to radiometric units and present a first step towards a toolbox of fluorescence standards, currently consisting of:
i) A first set of liquid fluorescence standards enables the determination of a broad variety of fluorescence parameters was developed and certified by BAM and is distributed by Sigma-Aldrich.
ii) Ready-to-use, glass-based fluorescence standards for instrument performance validation (IPV) and determination instrument-to-instrument variations can also be used as wavelength standard for fluorescence instruments with low requirements on spectral resolution and allow monitoring of temporal changes of the wavelength-dependent spectral responsivity.
iii) Novel calibration tools and validation concepts for microarray-based platforms used in molecular diagnostics and food safety control.
iv) We currently develop reference materials, which can be used as reliable quantum yield standards for relative methods for the determination of QY and can be valuable in the evaluation of the performance and sources of uncertainty of absolute, standard-free methods using e.g. integrating spheres.
Fluorophore labeled proteins and antibodies, referred to also as targeted optical probes, present a promising strategy for a variety of applications from fundamental cell-based biological studies to in vivo diagnostics and image guided surgeries in humans. In this respect, design strategies for the preparation of such conjugates from different dyes including analyte-responsive fluorophores are presented as well as their analytical and spectroscopic characterization employing Absorption spectroscopy and steady state and time-resolved fluorometry. Special emphasis is dedicated to the influence of dye hydrophilicity and labeling density on the optical properties and binding behavior of these dye-bioconjugates including their performance in in vitro and in vivo bioimaging studies.
Nowadays, superplasticizers (SPs) are widely used to increase fluidity and reduce water content in concrete; thus, allowing better workability for final applications. The present study will focus on the hydration effect using comb shape polycarboxylates (PCEs), which are known to allow a very low water/cement ratio (w/c of 0.20) or less.Optical methods have been successfully used for the analysis and monitoring of the interactions between a broad variety of nanoscale and molecular systems like nanoparticles of various chemical composition and different types of organic ligands or biomolecules.This encouraged us to assess the potential of these methods, and particularly fluorescence, for the investigation of the interactions that occur at the interface between hydrate surfaces of cement particles and PCE at a very early stage of concrete formation and to differentiate between the impact of PCE’s molecular structures on such interactions.
Biosensors, as defined by Pure and Applied Chemistry, are ‘chemical sensors in which the recognition System utilizes a biochemical mechanism. The biological recognition system translates information from the biochemical domain, usually an analyte concentration, into a chemical or physical output signal with a defined sensitivity’.(1) It is also appointed that chemical or biological sensors contain two basic components connected in series: a chemical or biomolecular recognition System (receptor) and a physicochemical transducer. According to this prerequisite, this overlook is confined to sensor devices that combine a biomolecular recognition element with an optical signal transducer. Homogeneous or intracellular assays using fluorescent molecular probes or nanoparticles are not considered, although they are frequently termed as molecular sensors or nanosensors in the literature.
Fluorescence-based biosensors are generalized as those devices that derive an analytical signal from a photoluminescent (either fluorescence or phosphorescence) emission process. Chemi- or bioluminescent detection systems are only briefly discussed in this review.
Biosensors are used for a wide variety of tasks, including detection of compounds of biomedical, environmental or defense interest; on-line monitoring for process control; quality control of foodstuffs; selective detection of compounds undergoing a chemical separation; and screening of drug compounds. Advantages of such devices include high selectivity, rapid response times, reusability, amenability to remote analysis, and immunity to electrical interferences. The selective nature of complexation between biomolecule and analyte and the small size of sensor devices can be combined with advanced detection techiques such as total internal reflection (TIR) spectroscopy. This results in an ability to measure analytes in complex matrices with unsurpassed sensitivity. Such samples may include highly scattering components such as milk or whole blood,(11) or relatively inaccessible locations such as groundwater wells, or even intracellular environments. The key limitation of such devices mainly centers on the poor stability of biological compounds, which can lead to a substantial drift in instrumental response over time. The so-called Cambridge Definition appoints another characteristic property of sensors. Therein, they are defined as ‘miniaturized devices which can deliver real-time and on-line information on the presence of specific compounds or ions in even complex samples’. Accordingly, a sensor is expected to respond reversibly and continuously. With the exception of some enzymatic sensors, these conditions are not fulfilled in case of most biosensors. Particularly, in devices where immunological reagents or DNA are used as recognition elements, they show a lack of reversibility and operate only as a ‘one-shot’ screen, without the potential for continuous, quantitative analysis. Nevertheless, the designations immunosensors or DNA sensors became accepted for such analytical or diagnostic tools.
Integrating fluorescent probes with sensing matrices presents a major challenge because usually, when confined in a rather rigid matrix, fluorophores tend to behave completely different than for instance in the molecular state in solution. The lecture reviews the major strategies that have been devised recently to circumvent such issues with special focus on the works carried out in this field by BAM’s Chemical and Optical Sensing Division. Moreover, it will be shown that by using certain strategies not only can the response behavior be retained but synergistic effects can even endow the hybrid with a much better performance than the probe molecule alone.
Macrocycle-containing fluorescent probes continue to be one of the most popular classes of indicator molecules for the sensitive optical detection of ionic inorganic analytes, in particular metal ions, since the first integration of crown ether building blocks into chromophoric π systems more than 30 years ago. However, whereas a large multitude of such probes have been described for operation in organic or mixed aqueous environments, the step to realistic analytical media such as water samples, aqueous food extracts or body fluids is still scarce. On one hand, this is due to considerably low complex stability constants for instance for alkali and alkaline-earth metal ions. On the other hand, many classes of organic dyes that show favourable spectroscopic properties and ion-induced responses in organic solvents are not soluble in neat aqueous media and/or exhibit only significantly quenched fluorescence, even if transition metal ions are binding strongly to the receptor unit. A way to circumvent such problems in a rather simple manner is the steric incorporation of fluorescent probes into mesoporous silica nanomaterials. The local polarity in such pores, whether nascent or modified appropriately with functional silanes, resembles much more a quasi-organic environment while at the same time allowing for free diffusion of water and its cargo.
Two examples of powerful hybrid signalling systems will be presented, utilizing charge transfer-type indicator molecules that show inferior sensing properties in their molecular state. One example discusses mercury(II) determination over an extended concentration range and the other discusses silver(I) and mercury(II) discrimination simply on the basis of photophysical effects retained in the hybrid materials.
Since more than 20 years, optical spectroscopic techniques, in particular fluorescence-based methods, are on the rise in many different areas of chemical and biochemical analysis, with no end being in sight.1,2 Advances in miniaturization and remote applications on one hand and ground-breaking developments in microscopy and laser-based high-throughput instrumentation on the other hand have fuelled these developments substantially.3,4 At the core of utmost of these applications however is not only the instrument, but a small entity that is able to absorb and emit photons and thus to report on the actual (bio)chemistry that is going on in a particular sample of interest.5,6 Besides intense research on various types of luminescent particles (e.g., quantum dots and carbon dots) and proteins, dye chemistry has thus seen its revival and the number of publications dealing with the design, synthesis and application of new fluorescent dyes as probes, stains, labels or indicators is still continuing to grow.
Among the various classes of dyes available as bright fluorophores for a wavelength range that is compatible with many (bio)analytical applications and the respective instrumentation, in particular pyrrolic dyes that do not belong to the classical porphyrins or phthalocyanines have received strong attention recently. Starting perhaps with the revival of the traditional boron-dipyrromethene laser dye ca. 15 years ago,7 these so-called BODIPYs have developed into a colourful spectrum of different derivatives.8 However, the interest in expanding the range of pyrrole-containing π-systems beyond BODIPYs has also constantly increased and has brought about several other pyrrole-based ring systems such as diketopyrrolopyrroles9 or dipyrrolonaphthyridinediones which possess a favourable brightness and other interesting properties. The present contribution will give a critical overview of the field, pinpointing advantages and prospects as well as discussing potential aspects of improvement with an emphasis on the chemical sensing and the longer wavelength range.
Quality control requirements imposed on assays used in clinical diagnostics and point-of-care-diagnostic testing (POCT), utilizing amplification reactions performed at elevated temperatures of 35 to 95 °C are very stringent. As the temperature of a reaction vessel has a large impact on the specificity and sensitivity of the amplification reaction, simple tools for local in situ temperature sensing and monitoring are required for reaction and assay control. We describe here a platform of stem-and-loop structured DNA hairpins (molecular beacons, MBs), absorbing and emitting in the visible and red spectral region, rationally designed for precise temperature measurements in microfluidic assays for POCT, and their ap-plication for temperature measurements in a common DNA-based molecular biological assay utilizing thermophilic helicase-dependent amplification (tHDA). Spectroscopic studies of these MBs, rationally designed from DNA se-quences of different thermal stabilities, chosen not to interact with the DNA probes applied in the nucleic acid amplification assay, and temperature-dependent fluorescence measurements of MB-assay mixtures revealed the suitability of these MBs for temperature measurements directly in such an assay with a temperature resolution of about 0.5 °C without interferences from assay components. Combining two spectrally distinguishable MBs provides a broader response range and an increase in temperature sensitivity up to 0.1 °C. This approach will find future application for temperature monitoring and quality control in commercialized diagnostics assays using dried reagents and microfluidic chips as well as assays read out with tube and microplate readers and PCR detection systems for temperature measurements in the range of 35 to 95 °C.