Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (7) (entfernen)
Sprache
- Englisch (7)
Referierte Publikation
- nein (7)
Schlagworte
- Moisture (7) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (7)
Moisture measurement methods
(2016)
Moisture can cause imperfect sealings, faulty roof constructions, cracks and other kind of damages. For measuring the moisture in construction materials like concrete and screed, there are destructive(direct) and non-destructive(indirect) methods, that can be used. This presentation gives an overview and a comparison of these methods.
Eight different screed types are tested including two different sample heights of 35 and 70 mm. The moisture of the four cement based and four sulphate based screeds are monitored during hydration and evaporation. All samples are stored in a climatic chamber at 23° C and 50 % relative humidity. Embedded sensors like temperature arrays, humidity sensor arrays, and multi-ring electrodes are embedded in the samples to yield a detailed moisture evolution with high depth resolution. Furthermore, nuclear magnetic resonance is used to quantify the water content at different depths. This multi-sensor approach allows a comprehensive monitoring of the moisture and its gradient in the different screed samples. This yields a deeper insight into the hydration, moisture convection, and diffusion processes.
Knowing the state of the setting process of concrete in buildings or the moisture level of old
walls can be crucial in determining further steps in the construction or restoration process. Small
2.4 GHz modules can be either embedded or applied on the surface to determine the moisture
distribution in material. Common modules, that are based on the highly available Bluetooth
Low Energy standard, emit electromagnetic waves, whose signal strength gets dampened by
water molecules. This effect serves as the basis on determining the moisture level in material.
We will show how to apply this method in a meshed sensor network for online monitoring.
In 2019, 3.1 billion Euro of damage was caused by piped water, accounting for the largest share (53%) of building insurance claims in Germany. In the event of damage, the accurate determination and localization of water ingress is essential to plan for and perform efficient renovations. Neutron probes are already applied successfully on building floors to localize the source of damage and other affected areas. However, additional information about the depth of moisture penetration can only be obtained by the destructive extraction of drilling cores, which is a time- and cost-intensive procedure. With its high sensitivity to water and fast measurement procedure, Ground Penetrating Radar (GPR) can serve as a suitable extension to the neutron probe, enabling more precise characterization of common forms of moisture damage.
In this research project, we study the influence of common types of moisture damage in differing floor constructions using GPR and a neutron probe. A measurement setup with interchangeable layers is used to vary the screed material (cement or anhydrite) and insulation material (Styrofoam, Styrodur, glass wool, perlite), as well as the respective layer thickness. Every configuration is measured for the following main cases: 1) dry state; 2) with a damaged insulation layer and 3) a damaged screed layer.
The evaluation is focused on the extraction of distinctive signal features for GPR, which can be used to classify the underlying case of damage. Furthermore, possible combinations of these features are investigated using multivariate data analysis and machine learning in order to evaluate the influence of different floor constructions.
To validate the developed methods, practical measurements on real damage cases in Germany are carried out and compared to reference data obtained from drilling cores.
BAM (Federal Institute for Materials Research and Testing) is developing an electronic measurement system to be placed inside a waste drum, which will be filled with concrete. The goal of this measurement system is to monitor the process of hardening and the evolution of the concrete itself over time to indirectly identify potential defects such as corrosion or cracking. The measured parameters are humidity, temperature, and pressure. In this regard, particular attention was given to the design of the electronic board’s enclosure, to allow the sensors to measure the state of the concrete without being in direct contact with it. In the scope of the European Commission’s project of PREDIS, the supply of power to the battery-less sensors and the data acquired by such sensors are transmitted through the metallic waste drum by an innovative wireless technology developed by VTT (Technical Research Centre of Finland) in order to ensure long-term operation while keeping the integrity of the sealed container.
BAM is developing an electronic measurement system to be placed inside a waste drum, which will be filled with concrete. The goal of this measurement system is to monitor the process of hardening and the evolution of the concrete itself over time to indirectly identify potential defects such as corrosion or cracking. The measured parameters are humidity, temperature, and pressure. In this regard, particular attention was given to the design of the electronic board’s enclosure, to allow the sensors to measure the state of the concrete without being in direct contact with it. In the scope of the EU project PREDIS, the data acquired by such sensors are transmitted from inside to outside the metallic waste drum through wireless technology.
The sensing system is made of a chain of small sensing units, called SensorNodes. Each SensorNode includes two off-the-shelf sensors, one for relative humidity and temperature and one for pressure and temperature. A SensorNode is designed to have a unique identifier, in order to be connected to other units while being uniquely discoverable by a standard communication protocol. In this way, a distributed matrix of measurement points is created.
One of the most challenging tasks in designing a measurement system to run in a harsh environment (such as hardening concrete) is to let the sensors sense the external environment without damaging the sensor itself.
To keep the external environment away from the electronic board while still letting the sensors measure the concrete behavior, holes have been drilled through the lid and covered from the inside with a layer of a porous membrane. The membrane's pores allow water and gas particles to pass through and let the enclosed air equilibrate with the external environment.
With the help of the developed sensors, monitoring concrete in cemented waste drums will be possible. The derived data will also serve as the basis for ongoing modeling approaches for digital twins within the Predis project. Overall, the sensors provide a means of enabling safe nuclear waste management through advanced monitoring