Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (48)
- Zeitschriftenartikel (35)
- Beitrag zu einem Tagungsband (25)
- Posterpräsentation (11)
- Buchkapitel (2)
- Handbuch (1)
- Sonstiges (1)
Schlagworte
- Concrete (55)
- Ultrasound (52)
- Monitoring (29)
- Coda wave interferometry (14)
- Imaging (14)
- Ultraschall (12)
- Non-destructive testing (8)
- Beton (7)
- Civil engineering (7)
- Validation (7)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (48)
The often poor construction and low maintenance level of tailings dams has caused serious accidents. The EC funded Project TAILSAFE is aimed at the non-destructive assessment of tailings facilities for stabilization analyses and the development of better management methods.
The focus of geophysical field studies was on the discrimination of different layering and construction steps as well as the determination of the spatial (relative) water content in the dams. SIP measurements at three tailings facilities different in their geological backgrounds, composition and age have been conducted.
Ultrasonic echo and transmission techniques are used in civil engineering on a regular basis. New sensors and data processing techniques have lead to many new applications in the structural investigation as well as quality control. But concrete structures in the nuclear sector have special features and parameters, which pose problems for the methods and instrumentation currently available, e.g. extreme thickness, dense reinforcement, steel liners or special materials. Several innovative ultrasonic techniques have been developed to deal with these issues at least partly in lab experiments and pilot studies. Modern imaging techniques as multi-offset SAFT have been used e. g. to map delaminations. Thick concrete walls have successfully been inspected, partly through a steel liner. Embedded ultrasonic sensors have been designed which will be used in monitoring networks of large concrete structures above and below ground. In addition, sensitive mathematical methods as coda wave interferometry have been successfully evaluated to detect subtle changes in material properties. Examples of measurements and data evaluation are presented.
Time reversal techniques are used in ocean acoustics, medical imaging and non-destructive evaluation to backpropagate recorded signals to the source of origin. We demonstrate experimentally a technique which improves the temporal focus achieved at the source location. The experiment consists of propagating a signal from a transducer within a concrete block to a single receiver on the surface, and then applying time reversal or deconvolution to focus the energy back at the source location. The results show that we are able to generate a focus in time at the correct location. The proposed method is simple and proven to be robust. Additionally, its costs are negligible due to deconvolution being a preprocessing step to the recorded data. The technique can be applied for detailed investigation of the source mechanisms (e. g. cracks) but also for monitoring purposes.
Ultraschallverfahren haben sich im Bauwesen in den letzten Jahren immer mehr in der Praxis etabliert. Echomessungen zur Geometriebestimmung sind Stand der Technik. In der Wissenschaft gibt es zahlreiche Ideen, die Messmethodik und die Auswertung weiter zu verbessern sowie den Einsatzbereich zu erweitern. Erste eingebettete Ultraschallsysteme zum Langzeitmonitoring sind installiert, Mehrkanalgeräte ermöglichen immer größere Aperturen und Eindringtiefen, verbesserte Abbildungsverfahren zeigen immer mehr Details. Zusätzlich lassen sich Verfahren aus der Geophysik adaptieren, die weiteren Fortschritt versprechen. Die Seismische Interferometrie dient klassisch dazu, Materialeigenschaften des Erduntergrundes mittels seismischer Wellen zu bestimmen. Derzeitige Anwendungsbereiche sind die Verbesserung seismischer Abbildungsverfahren, Interpolation seismischer Spuren (A-Scans), Bestimmung von Quellparametern oder die Eliminierung unerwünschter Signale in passiven und aktiven Experimenten, hauptsächlich durch Kreuzkorrelation und Bestimmung Greenscher Funktionen. Diese Techniken können auch auf Ultraschalldaten, die an Betonkonstruktionen erfasst wurden, angewendet werden. Moderne Abbildungsverfahren benötigen eine möglichst hohe A-Scan-Dichte und eine genaue Kenntnis des Quellsignals. Beides ist nicht unbedingt gegeben, z. B. wegen der physischen Größe der Sensoren und wechselnder Ankopplungsbedingungen. In simulierten und realen Experimenten wurden interferometrische Methoden zur Lösung dieser Aufgabenstellungen evaluiert. Es zeigt sich, dass fehlende A-Scans kinematisch korrekt interpoliert werden können, wenn ausreichend viele Sender- und Empfängerpositionen genutzt wurden. Amplituden und Signalform sind verändert, können aber durch adaptive Filterung angepasst werden. Die Quellsignalform kann mit hoher Genauigkeit rekonstruiert werden. Die Ergebnisse können potentiell zu einer Verbesserung der Abbildung des Inneren der untersuchten Objekte genutzt werden.
Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. This involves also jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty of this method is to predict the column diameter and its material strength. Here, we present two-dimensional finite-difference numerical simulation results of a promising non-destructive quality assurance testing tool to evaluate the diameter of jet grout columns. This approach incorporates crosshole and downhole seismic measurements. Preliminary tests showed that this tool is applicable under real site conditions.
Ultrasonic echo testing is widely used in non-destructive testing in civil engineering to investigate concrete structures, to measure thickness, and to locate and characterise built-in components or inhomogeneities. Currently, synthetic aperture focusing techniques are mostly used for imaging. These algorithms are highly developed but have some limitations. For example, it is not possible to image the lower boundary of built-in components like tendon ducts or vertical reflectors. We adopted reverse time migration for non-destructive testing in civil engineering in order to improve the imaging of complicated structures in concrete. By using the entire wavefield, including waves reflected more than once, there are fewer limitations compared to synthetic aperture focusing technique algorithms. As a drawback, the required computation is significantly higher than that for the techniques currently used. Simulations for polyamide and concrete structures showed the potential for non-destructive testing. The simulations were followed by experiments at a polyamide specimen. Here, having acquired almost noise-free measurement data to test the algorithm, we were able to determine the shape and size of boreholes with sufficient accuracy. After these successful tests, we performed experiments at a reinforced concrete foundation slab. We obtained information from the data by reverse time migration, which was not accessible by traditional imaging. The imaging of the location and structure of the lower boundary of the concrete foundation slab was improved. Furthermore, vertical reflectors inside the slab were imaged clearly, and more flaws were found. It has been shown that reverse time migration is a step forward in ultrasonic testing in civil engineering.
Recently developed new transducers for ultrasonic transmission, which can be embedded right into concrete, are now used for non-destructive permanent monitoring of concrete. They can be installed during construction or thereafter. Large volumes of concrete can be monitored for changes of material properties by a limited number of transducers. The transducer design, the main properties as well as installation procedures are presented. It is shown that compressional waves with a central frequency of 62 kHz are mainly generated around the transducer's axis. The transducer can be used as a transmitter or receiver. Application examples demonstrate that the transducers can be used to monitor concrete conditions parameters (stress, temperature,
) as well as damages in an early state or the detection of acoustic events (e.g., crack opening). Besides application in civil engineering our setups can also be used for model studies in geosciences.
Challenging new constructions and ageing infrastructure are increasing the demand for permanent monitoring of loads and condition. Various methods and sensors are used for this purpose. But the technologies available today have difficulties in detecting slowly progressing locally confined damages. Extensive investigations or instrumentations are required so far for this purpose. In this study we present new sensors and data processing methods for ultrasonic transmission, which can be used for non-destructive long term monitoring of concrete. They can be mounted during construction or thereafter. Larger volumes can be monitored by a limited number of sensors for changes of material properties. The principles of ultrasonic transmission and influencing factors are presented. This latter include load, damages as well as environmental parameters as temperature or moisture. Various methods for data processing, e. g. coda wave interferometry are introduced. They allow the detection of very small changes in the medium. The embedded sensors are shown including mounting and operation. Application examples so far include small scale laboratory freeze-thaw experiments, localizing loads in larger concrete models, monitoring load effects on real structures as well as detecting acoustic events. Some sensors are operating already for several years. The sensors can be used as transmitter or receivers or switched between both roles. While most of the previous experiments have been active (at least one sensor serving as transmitter), new studies show that the sensors are useful as well for passive measurements, e. g. in acoustic emission or time reversal experiments. Besides application in civil engineering our setups can also be used for model studies in geosciences.
Geophysical methods have been used in civil engineering for decades. The main field of application is - to no surprise – in geotechnical projects from site characterization to foundation quality assurance. For more than 25 years, ground penetrating radar (GPR) and seismic methods have found applications in structural engineering. Recently introduced geophysical methods have been adopted to ultrasonic investigations in various fields. They help to improve the quality of structural imaging and to detect small changes in concrete. An overview of the history and current use of geophysics in civil engineering is given. Selected examples of new concepts include advances in wave based imaging, quality assurance for foundations, detecting small changes in concrete as well as moisture and corrosion detection are discussed.
Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. One commonly applied method is jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty linked with this method is to predict the resulting column diameter and its material strength. In this paper we illustrate the application of a newly developed non-destructive quality assurance testing tool used to determine the diameter of jet grout columns. This approach incorporates standard crosshole and downhole seismic measurements. To demonstrate its effectiveness, we tested the new approach within two-dimensional finite-difference numerical simulations. Additional field tests showed that this tool is also applicable in real site conditions. For this purpose, three jet grout columns were produced with different process parameters in a depth between 3.0 and 10 m. The evaluated diameters were within 1.0 and 1.5 m, slightly deviating from the previously predicted range by the jet grouting contractor. Moreover, we were able to detect the base of the columns at 10 m depth with no significant difficulties. On the other hand, unsaturated, partly unconsolidated sands between ground water level and surface considerably affected the seismic data, hence complicating the detection of the top of the columns.