Analytische Chemie
Filtern
Erscheinungsjahr
- 2023 (190) (entfernen)
Dokumenttyp
- Vortrag (74)
- Zeitschriftenartikel (65)
- Posterpräsentation (36)
- Beitrag zu einem Tagungsband (4)
- Sonstiges (4)
- Dissertation (3)
- Forschungsdatensatz (2)
- Buchkapitel (1)
- Handbuch (1)
Sprache
- Englisch (173)
- Deutsch (16)
- Mehrsprachig (1)
Schlagworte
- Fluorescence (18)
- Reference material (15)
- Nano (14)
- Traceability (14)
- PFAS (12)
- Quality assurance (12)
- Dye (9)
- Metrology (9)
- Particle (9)
- Quantum yield (9)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (190) (entfernen)
Paper des Monats
- ja (9)
Eingeladener Vortrag
- nein (74)
Engineered nanomaterials (NM) with their large surface-to-volume ratios and their for some materials observed size-dependent functional properties are of increasing relevance for current and future developments in various fields such as medical and pharmaceutical industry, computing and electronics or food and consumer products. The performance and safety of NM are determined by the sum of their intrinsic physicochemical properties. Especially, the particle surface chemistry, which is largely controlled by the chemical nature and density of functional groups (FG) and ligands, is an important key driver for NM performance, stability, and processibility as well as the interaction of NM with the environment. Thus, methods for FG quantification can foster the sustainable development of functional and safe(r) NM.
Aiming at the development of simple, versatile, and multimodal tools for the quantification of many bioanalytically relevant FG and ligands, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance and thermal analysis methods.
The potential of our multimodal approach for FG quantification was demonstrated for commercial and custom-made polymeric and silica particles of varying FG, used as optical pH sensors. In the future, our strategy can contribute to establish multi-method characterization strategies to provide a more detailed picture of the structure-properties relationship.
Nowadays amorphous silica nanoparticles (SiO2-NP) are one of the most abundant engineered nanomaterials, that are highly stable and can be easily produced on a large scale at low cost. Surface functionalized SiO2-NP are of great interest in the life and material sciences, as they can be used e.g. as
drug carriers, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. Their performance in such applications depends not only on particle size, size distribution, and morphology, but also on surface chemistry, i.e. the total number of surface functional groups (FG)
and the number of FG accessible for subsequent functionalization with ligands or biomolecules, which in turn determines surface charge, colloidal stability, biocompatibility, and toxicity. Aiming at the development of simple, versatile, and multimodal tools for the quantification of many bioanalytically relevant FG and ligands, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance and thermal analysis methods.
The potential of our multimodal approach for FG quantification was demonstrated for commercial and custom-made silica particles of varying FG, showing not only an influence of the synthesis methods on the number of FG but also on the performance. In the future, our strategy can contribute to establish multi-method characterization strategies to provide a more detailed picture of the structure-properties relationship.
Iron isotopes are used in a variety of fields from e.g., geologic question to medical applications. Measurements of iron isotopes are usually performed as delta measurements to an artificial based delta zero standard. In the case of Fe isotopes is that delta zero standard IRMM-014, a pure Fe metal. Unfortunately, that conventional delta zero reference material defining the 56/54Fe scale is out of stock and therefore unavailable. To overcome that situation and fulfill the need for laboratories that measure Fe isotope on a regular basis we will provide a set of solutions with IRMM-014 and a second anchor point for Fe isotope ratio measurements that is based on a pure Fe metal. This new second anchor point, a high purity Fe from BAM, will be calibrated against IRMM-014 and can be used as bracketing standard or as reference value for stable Fe isotope measurements.
We are in the good situation that BAM ordered a large stock of IRMM-014 several years ago. That stock of IRMM-014 Fe cubes and IRMM-014 Fe wires will be dissolved in 6M HCl in a large quantity. The new anchor point, the high purity Fe metal, that is commercially available at BAM, is a pure Fe metal with only trace amounts of impurities. The high purity BAM material will also be dissolved in 6M HCl in large quantity. Several aliquots of both solutions will be measured on the Neptune Plus MC-ICP-MS to define this second anchor point with a low uncertainty. Further will we send several aliquots of both solutions to different laboratories to also measure this second anchor point of high purity Fe on the 56/54Fe scale.
We will report the values of that study on BAM high purity Fe and will provide a guide for scale conversion to the IRMM-014 scale and for uncertainty calculation to use that new anchor point instead of the exhausted IRMM-014.
Immunoassays, based on the recognition and capture of analytes by highly selective antibodies, are now used extensively in all areas of diagnostics, but the challenge is to further integrate them into online sensors. To improve the transition from laboratory immunoassays to immunosensors, we have developed a complete flow system, based on a microfluidic core flow cell to enable automated detection of one of the most commonly used immunoassay substrates, TMB, by chronoamperometry. The architecture and fluidic optimisation of the system showed that a specially designed 3D flow cell allows higher flow rates (500 μL min−1) than a standard enlarged microfluidic channel (50 μL min−1) resulting in a significantly shorter detection time of 30 seconds per sample and making the system more robust against interferences due to bubble formation in the chip. The electrochemical measurements showed an improved signal-to-noise ratio (SNR) and thus higher sensitivity for a model immunoassay for diclofenac (SNR = 59), compared to the analytical performance of a conventional laboratory microplate-based assay with optical detection (SNR = 19). In general, this system facilitates the conversion of any conventional immunoassay into an immunosensor with automatic and continuous detection.
Introduction
Per- and polyfluorinated alkyl substances (PFASs) are a group of over 4730 individual compounds. Several PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their various chemical and physical properties as well as the high number of compounds. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate realistic PFAS pollution levels.
Methods
For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. In our study we used high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) which is a sensitive and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L.
Results
Here, we present an improved method for the determination of PFASs using HR-CS-GFMAS via GaF detection. The optimized method includes a modifier pretreatment step using a mixture of Mg, Pd and Zr and a correction measurement using perfluorooctanoic acid. The combination of both resulted in increased accuracy and precision as well as overall lower detection limits. Furthermore, during optimization the influence of species-specific responses during HR-CS-GFMAS analysis was reduced resulting in a more accurate determination of PFAS sum parameters. To test the applicability of the improved method, we analysed soil samples from a former fire-fighting training area combining the improved method for detection with our previously optimized extraction method for extractable organically bound fluorine (EOF) determination in soils.
Innovative aspects
• Highly sensitive and selective method for fluorine/PFASs analysis based on HR-CS-GFMAS
• Increased accuracy for the determination of EOF
• Reduction of PFAS species-specific responses by optimized modifier conditions
HR-CS-GFMAS turned out to be a sensitive, fast and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) at a temperature of 1550°C. GaF can be detected at 211.248 nm providing limits of quantificationin the low μg/L range. However, several species specific effects where observed when analyzing PFASs.
Per- und polyfluorierte Alkylverbindungen (PFAS) sind eine Substanzklasse bestehend aus mehreren tausenden Einzelverbindungen. Unter PFAS zählen alle Verbindungen, die mindestens eine perfluorierte Methyl- (-CF3) oder Methylen-Gruppe (-CF2-) besitzen. Somit zählt auch ein großer Teil der fluorierten Medikamente, Pflanzenschutzmittel oder Biozide in die PFAS-Substanzklasse. Aufgrund der Persistenz, Bioakkumulation in Nahrungsketten, Toxizität und der ubiquitären Verbreitung von PFAS zählen sie zu den „emerging pollutants“. Die PFAS-Analytik ist wegen ihrer vielfältigen physikalisch-chemischen Eigenschaften und der sehr hohen Anzahl an PFAS eine große Herausforderung. Da es für viele Anwendungen noch ungewiss ist, welche PFAS verwendet werden, wie sie in die Umwelt gelangen und welche Transformations- bzw. Abbauprodukte entstehen, stoßen analytische Ansätze, die nur auf Einzelsubstanzen abzielen, hier an ihre Grenzen. PFAS-Summenparameter-Methoden, die darauf abzielen ein möglichst vollständiges Abbild der PFAS-Belastungssituation widerzuspiegeln, werden daher immer wichtiger.
Per- und polyfluorierte Alkylverbindungen (PFAS) sind eine Substanzklasse bestehend aus mehreren tausenden Einzelverbindungen. Unter PFAS zählen alle Verbindungen, die mindestens eine perfluorierte Methyl- (-CF3) oder Methylen-Gruppe (-CF2-) besitzen.[1] Somit zählt auch ein großer Teil der fluorierten Medikamente, Pflanzenschutzmittel oder Biozide in die PFAS-Substanzklasse. Aufgrund der Persistenz, Bioakkumulation in Nahrungsketten, Toxizität und der ubiquitären Verbreitung von PFAS zählen sie zu den „emerging pollutants“.[2] Die PFAS-Analytik ist wegen ihrer vielfältigen physikalisch-chemischen Eigenschaften und der sehr hohen Anzahl an PFAS eine große Herausforderung. Da es für viele Anwendungen noch ungewiss ist, welche PFAS verwendet werden, wie sie in die Umwelt gelangen und welche Transformations- bzw. Abbauprodukte entstehen, stoßen analytische Ansätze, die nur auf Einzelsubstanzen abzielen, hier an ihre Grenzen. PFAS-Summenparameter-Methoden, die darauf abzielen ein möglichst vollständiges Abbild der PFAS-Belastungssituation widerzuspiegeln, werden daher immer wichtiger.