Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (80) (entfernen)
Sprache
- Englisch (53)
- Deutsch (26)
- Mehrsprachig (1)
Referierte Publikation
- nein (80) (entfernen)
Schlagworte
Organisationseinheit der BAM
- 8.1 Sensorik, mess- und prüftechnische Verfahren (80) (entfernen)
Eingeladener Vortrag
- nein (80)
Remote gas sensors like those based on the Tunable Diode Laser Absorption Spectroscopy (TDLAS) enable mobile robots to scan huge areas for gas concentrations in reasonable time and are therefore well suited for tasks such as gas emission surveillance and environmental monitoring.
A further advantage of remote sensors is that the gas distribution is not disturbed by the sensing platform itself if the measurements are carried out from a sufficient distance, which is particularly interesting when a rotary-wing platform is used.
Since there is no possibility to obtain ground truth measurements of gas distributions, simulations are used to develop and evaluate suitable olfaction algorithms.
For this purpose several models of in-situ gas sensors have been developed, but models of remote gas sensors are missing.
In this paper we present two novel 3D ray-tracer-based TDLAS sensor models. While the first model simplifies the laser beam as a line, the second model takes the conical shape of the beam into account.
Using a simulated gas plume, we compare the line model with the cone model in terms of accuracy and computational cost and show that the results generated by the cone model can differ significantly from those of the line model.
Acoustic Emission
(2018)
Das Phänomen Schallemission (eng. Acoustic Emission, AE) ist eine Begleiterscheinung bei aktiven Mechanismen und Prozessen wie sie in Werkstoffen auftreten, die einer Belastung durch Krafteinwirkung oder durch Änderung der Umgebungsbedingungen ausgesetzt sind. Plastische Verformung, Risswachstum, Korrosion oder der Übergang zu einer anderen Phase generieren u.a. transiente elastische Wellen, die sich im Werkstoff und an der Materialoberfläche ausbreiten. Auftretende Auslenkungen von wenigen hundert Pikometern sind mit piezo-elektrischen AE Sensoren detektierbar. Aufzeichnungsraten von bis zu 40 MHz ermöglichen dabei zeitliche Auflösungen von einigen Nano- bis Mikrosekunden. Die Dechiffrierung der detektierten Informationen ist für die Material- und Versagenscharakterisierung sowie für Anwendungen in der Struktur- oder Prozessüberwachung ein zentraler Forschungsschwerpunkt.
Nach einem kurzen Überblick zu den Grundlagen werden ausgewählte Ansätze der AE Methode vorgestellt und diskutiert:
1) AE Monitoring von Pipelines als Referenzmessung für die Entwicklung eines akustischen faseroptischen Monitorings (AGIFAMOR)
2) Schwellwertfreie AE Messung im 4-Punkt-Rohrbiegeprüfstand BAM_9.1 (AGIFAMOR)
3) Kombination von AE mit Röntgen-Mikrotomografie und die Anwendung der frequenzbasierten Mustererkennung ermöglichen eine Zuordnung von AE und Mechanismen (Ergebnisse aus dem SNSF Projekt Nr. 127'134, Baensch 2014, Diss. ETH No. 22372)
Typically, the near-eutectic Al-Si alloys consist of highly interconnected three-dimensional network of the eutectic Silicon (Si) and intermetallics embedded into Aluminium (Al) matrix. For further improvement of the mechanical properties of such alloys, often, one single ceramic reinforcement phase, e.g. silicon carbide (SiC) or aluminium oxide (Al2O3) in the form of fibres or particles is added. However, hybrid reinforcements (fibres and particles) can further improve wear resistance and fracture toughness, and additionally, reduce anisotropy of the material. The engineering of metal matrix composites (MMC) for specific application requirements benefits from a comprehensive knowledge of the failure behaviour. Therefore, damage evolution under compression was investigated on:
- pure near-eutectic AlSi12CuMgNi matrix alloy
- type I: matrix reinforced with random-planar oriented Al2O3 short fibres (15 vol.%)
- type II: matrix reinforced with random-planar oriented Al2O3 short fibres (7 vol.%) and additional SiC particles (15 vol.%)
The analysis of damage mechanism was carried out in two rather independent but complementary studies. First, selected sister samples of every material were exposed to quasi-static compression (traverse control). The compression tests were interrupted at different strain levels. Miniature cylinders with a diameter of 1mm were extracted from the pre-strained samples and investigated by synchrotron computed tomography (SX-µCT) with a spatial resolution of about 0.7 µm. For the pure matrix alloy, microcracks are confined to the intermetallic particles and to the eutectic Si, hence no damage was observed in the Aluminium. The composite type II revealed a more effective strain accumulation (less damage) than type I at low plastic strain (up to 5 %), but a more catastrophic damage development due to cracking of the SiC clusters at higher strain levels.
The second approach to study the damage initiation and accumulation in the materials subjected to compressive load was Acoustic Emission (AE) analysis. In this case the in-situ monitoring of the acoustic emission signal was performed during compression tests on specimens with dimension of several mm. For all three material types, AE activity set at 2% strain. Differences in AE behaviour of the three materials was proven based on AE hitrate, signal peak amplitudes as well as weighted peak frequencies (WPF). Future work focuses on combination of AE and SX-µCT aiming for more detailed knowledge on damage mechanism of metal matrix composites.
Acoustic emission testing
(2018)
Aerial Robot Olfaction @BAM
(2021)
Ammoniakemissionen in die Umwelt erfolgen insbesondere durch die Landwirtschaft (93,6 %), aber auch durch Verbrennungsprozesse in der die Abfallwirtschaft (2,3 %) und den Straßenverkehr (1,8 %). Dieser Stoff ist selbst in geringen Konzentrationen nicht nur eine Geruchsbelästigung, sondern auch eine Substanz mit ökologischer und klimatischer Relevanz.
Die Bestimmung von Ammoniak in relevanten Konzentrationen von kleiner 25 μg m-3 erfolgt im Allgemeinen über NH4+ als Analyten, spektralfotometrisch oder mit der Ionenchromatographie nach Überführung in die flüssige Phase. Wegen der niedrigen Konzentrationen an Ammoniak in der Außenluft wird meist eine gesammelte Probe verwendet oder die Bestimmung erfolgt nach einer aktiven, anreichernden Probenahme.
Die eigenen Arbeiten sollen dazu beitragen, die Ammoniak-Bestimmung in der Außenluft präziser, sowie schneller und kostengünstiger zu machen.
Die BAM prüfte daher kommerzielle elektrochemische und Metalloxid-basierte Sensoren, die für diesen Konzentrationsbereich aber nur bedingt geeignet sind. Deshalb wurden alternativ eigene Entwicklungen zum Nachweis von Ammoniak im Spurenbereich aufgenommen, wobei der Analyt über die Änderung der Fluoreszenz eines BODIPY-Farbstoffs bei 550 nm mittels eines portablen Fluoreszenz-Sensors direkt aus der Gasphase gemessen wird.
Zur Kalibrierung von Ammoniak-Sensoren und -Messgeräten steht ein stationäres System basierend auf der Mischung von zertifizierten Prüfgasen aus Druckflaschen mit kalibrierten Massendurchfluss-regler (MFC) zur Verfügung. Darüber hinaus erfolgt eine chemische Analyse der verwendeten Gasgemische mittels eines Massenspektrometers.
Für die Kalibrierung und Prüfung von Sensoren und Messgeräten vor Ort wurde ein mobiles Prüfsystem entwickelt. Die Generierung von Ammoniak-haltigen Gasen im Spurenbereich von 0,5 nmol/mol bis 500 nmol/mol erfolgt durch das Permeationsverfahren nach ISO 6145-10.
Für die Realisierung der Rückführbarkeit der Ammoniakbestimmung werden von den Nationalen Metrologischen Instituten sowie designierten Instituten Standards bereitgestellt und auch weiterentwickelt. Die primären metrologischen Standards beruhen auf SI-Einheiten und sind die Basis für eine Rückführbarkeit der Sensoren bzw. Analysengeräte.
Die Effizienz von Gassensoren zur sicheren Verwendung von Wasserstoff hängt wesentlich von der Reaktion des Sensors auf eine Änderung der Wasserstoffkonzentration ab. Daher wurde die Ansprechzeit von fünf im Handel erhältlichen Wasserstoffsensoren unterschiedlichen Messprinzips bestimmt. Experimente haben gezeigt, dass alle Sensoren die Anforderungen der Norm ISO 26142 übertreffen; es wurden Ansprechzeiten im Bereich (t90-Zeiten) von 2 s bis 16 s ermittelt. Die Ergebnisse können mit Exponential- oder Sigmoidalfunktionen approximiert werden. Es kann gezeigt werden, dass die Ergebnisse zum transienten Verhalten sowohl von den Betriebsparametern der Sensoren und Prüfverfahren als auch von den experimentellen Bedingungen wie Gaswechselrate sowie Konzentrationssprung abhängen.