Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (45) (entfernen)
Referierte Publikation
- nein (45) (entfernen)
Schlagworte
- Traceability (19)
- Metrology (18)
- Absolute isotope ratio (13)
- Uncertainty (8)
- Isotope ratio (7)
- CCQM (5)
- Isotope reference material (4)
- Copper (3)
- Delta value (3)
- Isotope amount ratio (3)
- Isotope delta value (3)
- Isotope fractionation (3)
- Reference material (3)
- Triple isotope fractionation (3)
- CMC (2)
- Cement (2)
- Delta scale (2)
- Isotope dilution mass spectrometry (2)
- Measurement uncertainty (2)
- Metrology in chemistry (2)
- Purity (2)
- Purity assessment (2)
- metrology (2)
- traceability (2)
- Alzheimer disease (1)
- Archaeology (1)
- Archaeometry (1)
- Atomic weight (1)
- Atomic weights (1)
- Biodiesel fuel (1)
- Blank characterization (1)
- Boron isotopes (1)
- Calibration (1)
- Certification (1)
- Cheese (1)
- Circular economy (1)
- Comparability (1)
- Comparison (1)
- Conventional isotope ratio (1)
- Conventional isotope ratios (1)
- Counting detector (1)
- Curse tablets (1)
- Degree of equivalence (1)
- Delta values (1)
- Dementia (1)
- Detector deadtime (1)
- Dual mode detector (1)
- EURAMET (1)
- Emissionen (1)
- Fundamental science (1)
- Gravimtric isotope mixtures (1)
- Gypsum (1)
- Heavy metals (1)
- Human serum (1)
- ICP-MS (1)
- ICPMS (1)
- IDMS (1)
- Impurities (1)
- Interferences (1)
- Iron (1)
- Isotope delta (1)
- Isotope mixtures (1)
- Isotope purification (1)
- Isotope reference materials (1)
- Lead isotopes (1)
- Mangesium (1)
- Mass spectrometry (1)
- Matrix separation (1)
- Measurement space (1)
- Metal sublimation (1)
- Metrology in Chemistry (1)
- Molar mass (1)
- Noise (1)
- Optimization (1)
- PGE (1)
- Plant metabolism (1)
- Primary method of measurement (1)
- Provenance (1)
- Purity determination (1)
- Quality system (1)
- Re-evaluation (1)
- SI traceability (1)
- Silicon (1)
- Silver artefacts (1)
- Soil (1)
- Standard addition (1)
- Sulfur (1)
- Synthetic isotope mixtures (1)
- TCE (1)
- Terminology (1)
- Tetramethylammonium hydroxide (1)
- Transferrin (1)
- Zinc (1)
- key comparison (1)
- purity (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (45)
Absolute Isotope Ratios
(2018)
Measurement results and scientific models leading to important decisions in forensics, food fraud or climatology are based on isotope ratio data. Molar masses of multi-isotopic elements are as well based on isotope ratio data. Thus, in the case of Si, isotope ratios directly impact the redefinition of the SI base units kilogram and mole. Therefore, new strategies are required leading to new primary isotope reference materials, whose isotope ratios are traceable to the SI. This in turn will ensure the comparability of isotope ratio data and will render the traceability exception requested by the CCQM superfluous. Such new procedures will be developed for the key elements S, Si, Ca, Sr and Nd at relative uncertainty levels of ≤ 0.01 %.
An introduction into absolute isotope ratios is given, with application fields ranging from fundamental science to geochronology and forensics. This is followed by a proposal for developing new calibration approaches for obtaining absolute isotope ratios at unrivaled uncertainty levels. This new developments will set the basis for improvements in all scientific fields.
CCQM-P149 is an attempt to obtain a snapshot on actual procedures the NMIs and DIs within CCQM-IAWG applied to the purity characterization of their “fit for purpose” elemental Standards. This presentation describes how the results of CCQM-P149 may be used to underpin calibration and measurement capabilities being claimed in the BIPM database.
A new method combining isotope dilution mass spectrometry (IDMS) and standard addition has been developed to determine the mass fractions w of different elements in complex matrices: (a) silicon in aqueous tetramethylammonium hydroxide (TMAH), (b) sulfur in biodiesel fuel, and (c) iron bound to transferrin in human serum. All measurements were carried out using inductively coupled plasma mass spectrometry (ICP–MS). The method requires the gravimetric preparation of several blends (bi)—each consisting of roughly the same masses (mx,i) of the sample solution (x) and my,i of a spike solution (y) plus different masses (mz,i) of a reference solution (z).
Only these masses and the isotope ratios (Rb,i) in the blends and reference and spike solutions have to be measured. The derivation of the underlying equations based on linear regression is presented and compared to a related concept reported by Pagliano and Meija. The uncertainties achievable, e.g., in the case of the Si blank in extremely pure TMAH of urel (w(Si)) = 90% (linear regression method, this work) and urel (w(Si)) = 150% (the method reported by Pagliano and Meija) seem to suggest better applicability of the new method in practical use due to the higher robustness of regression analysis.