Analytische Chemie
Filtern
Erscheinungsjahr
- 2016 (737) (entfernen)
Dokumenttyp
- Vortrag (246)
- Zeitschriftenartikel (228)
- Posterpräsentation (139)
- Beitrag zu einem Tagungsband (78)
- Sonstiges (19)
- Dissertation (7)
- Buchkapitel (6)
- Beitrag zu einem Sammelband (4)
- Forschungsbericht (4)
- Tagungsband (Herausgeberschaft für den kompletten Band) (3)
Sprache
- Englisch (637)
- Deutsch (98)
- Mehrsprachig (2)
Schlagworte
- XPS (26)
- Fluorescence (23)
- Synchrotron (21)
- Concrete (19)
- Nanoparticles (19)
- Prozessanalytik (17)
- Simulation (16)
- XRF (16)
- BAMline (15)
- NEXAFS (15)
Eingeladener Vortrag
- nein (246)
The introduction of HR-CS-MAS instrumentation, as it is shown in Fig. 1, provides a new way for the determination of non-metals including fluorine via molecular absorption. We present a sensitive and fluorine-specific method for total fluorine determination in fifteen consume care products in which perfluordecalin were declared (nail polishes, eye shadows and body creams). After pyrohydrolytic digestion of samples, fluorine content was determined by GF-HR-CS-MAS. Calcium was used as a molecule forming element and the molecular absorption of calcium monofluoride (CaF) at the wavelength 606.440 nm was used for its quantification. No matrix effect was observed. Analytical signal depends only on the fluorine concentration and therefore pure sodium fluoride NaF was used as calibration standard. The use of zirconium oxide nanoparticles as permanent modifier improves the limit of detection (from 0.2 to 0.1 ng) and characteristic mass (from 0.10 to 0.05 ng) from a previous reported method. These results were also compared with ISE method (standard DIN 51-084) and no significant difference was found
An energy-based method to determine material constants in nonlinear rheology with applications
(2016)
Many polymer-type materials show a rate-dependent and nonlinear rheological behavior. Such a response may be modeled by using a series of spring-dashpot systems. However, in order to cover different time scales the number of systems may become unreasonably large. A more appropriate treatment based on continuum mechanics will be presented herein. This approach uses representation theorems for deriving material equations and allows for a systematic increase in modeling complexity. Moreover, we propose an approach based on energy to determine thematerial parameters.This method results in a simple linear regression problemeven for highly nonlinearmaterial equations. Therefore, the inverse problem leads to a unique solution. The significance of the proposed method is that the stored and dissipated energies necessary for the procedure are measurable quantities. We apply the proposed method to a 'semi-solid' material and measure its material parameters by using a simple-shear rheometer.
Immunoassays based on the detection of the antibody -Antigen interaction belong to the most important analytical techniques.
Electrochemical methods in immunoassays are increasingly used as they offer some advantages as being fast, simple, portable and cheap detection methods.
Cocaine is a highly addictive stimulant that occurs naturally as an Alkaloid of the Coca plants. It is frequently detected on bank notes and in wastewater.
Immunoassays based on the detection of the antibody-antigen interaction belong to the most important analytical techniques.
Electrochemical methods in immunoassays are increasingly used as they offer some Advantages as being fast, simple, portable and cheap detection methods.
Cocaine is a highly addictive stimulant that occurs naturally as an Alkaloid of the Coca plants. It is frequently detected on bank notes and in wastewater.
The presentation shows how the three-dimensional quantification of dislocations and their characteristic features, e.g. Burgers vector, line direction, dislocation density, is carried out at the transmission electron microscope in scanning mode (STEM) at Division 5.1 at BAM. Exemplarily, the methods are shown for Ni-base superalloy single crystals, for which a short introduction is given using further TEM techniques. Additional examples on low angle grain boundaries, nucleation of oxides at dislocations and interaction of dislocations and carbides are shown.
The content of the presentation was addapted, aiming at scientists who work within the DFG Priority Programme 1713 "Strong coupling of thermo-chemical and thermo-mechanical states in applied materials".
A wide range of properties in crystalline materials is affected by the presence of dislocations, the carriers of plastic deformation. Dislocations can be thought of as filiform structures, characterized by geometrical factors such as their Burgers vector, slip plane, length per unit volume (dislocation density) and line direction. In technical materials such as functional and structural alloys, as well as in minerals, the understanding of bulk deformation driven by dislocation activity is of paramount importance, and thus also the techniques that allow its characterization. Since decades, diffraction contrast in the transmission electron microscope (TEM) is widely implemented to image and describe two-dimensional (2D) projections of dislocation substructures in thin foils [1]. Recently, the use of electron tomography was applied for the first time to fully reconstruct a 3D dislocation network in a GaN epilayer [2]. Although this latter technique has gained popularity, it usually requires an elaborate experimental setup, as well as sophisticated image post-processing methods for a successful reconstruction. Stereoscopic methods in the TEM also have traditionally allowed the three-dimensional (3D) observation of dislocations [e. g. 3]. For this purpose, the same region of a TEM foil is imaged using the same diffraction vector with two beam directions slightly tilted from each other. Subsequently, the pair of images is observed with help of stereo-viewers or 3D glasses. Based on this principle, a system based on a special hardware and software combination was developed for segmentation and analysis of stereomicroscopy data in biological research, and it was also used to analyze simple dislocation structures [4]. In the present contribution a simple software tool is introduced, which has been developed to reconstruct, visualize and quantify dislocation substructures in the thicker regions of electron-transparent foils. A special focus is set on the use of scanning (S)TEM for its implementation.
As depicted in Figure 1, the tool is based on the separate tracing of dislocation line segments on both images of a stereo-pair. The points 1, 2 and 3 are marked on the images viewed by the left and right eyes (Figures 1a and b, respectively), showing an relative displacement Δx on the superimposed images in the anaglyph of Figure 1c. This Δx is given by the point’s depth Δh and by the stereo-angle ϑ, as shown in Figure 1d. By knowing the beam direction for the left and right images (BL and BR, respectively), ϑ can be determined, and hence also Δh. Once the depth information from all traced nodes is gained, a reconstruction is made (Figure 1e) where the line length can directly be read from the tool’s interface. The setup is merely geometrical and only needs the relative tilt between both images, the direction of the tilt axis and the image calibration, thus allowing asymmetrical tilts with respect to the foil normal. The foil thickness is measured directly from the endings of the dislocations on the bottom and top surfaces of the TEM foil, and is determined as t ~ 370 nm for the region in Figure 1. With t, the volume is in Figure 1e is also known, and the total dislocation density of the region is calculated as ρt = 44.4 x 1012 m∙m-3. It is clear from Figure 1 that in the Ni-base superalloy presented here, the dislocation substructures are highly localized towards the interface between the two phases of which the microstructure is composed, γ and γ’ (labeled in Figure 1a). The reconstructed model allows a separation of the dislocation densities within the γ and the γ’ phases and at their interface, which would be rather difficult by using common methods such as the one proposed by Ham [5]. Thus the partial dislocation densities are measured as ργ = 1.7 x 1012 m∙m-3, ργ’ = 2.7 x 1012 m∙m-3 and ργ/γ’ = 40.0 x 1012 m∙m-3. The tool also incorporates the knowledge of the crystallographic positions at the two tilts to enable plotting the line segment orientations. One can chose to display the resulting line directions as an interactive table; as an additional spherical spatial graph, where all lines extend from the center of a sphere; as a 2D plot of the spherical coordinates θ and φ; or as points plotted on a stereographic projection.
Thus, a simple software tool has been developed that allows the reconstruction, visualization and quantification of foil thickness, localized dislocation densities (or other filiform substructures) and orientations based on only one stereo-pair
Dislocations, as carriers of plastic deformation, affect important properties in technical materials, e. g., plasticity. The realistic description of plastic deformation caused by dislocations demands the representative measurement of their features, e.g., line direction, slip plane, Burgers vector and density. Bulk deformation of structural and functional alloys requires reliable data from large regions. The filiform nature of dislocations interacting with complex microstructures additionally demands observation and analysis techniques that allow resolving the details of their interactions in space. The use of electron tomography for this purpose is bound to difficult and time consuming experimental setups, which are not always applicable to any material. In this contribution a new tool is presented, which enables the three-dimensional reconstruction, visualization and quantification of dislocation densities and directions from manual tracing of scanning transmission electron microscopy (STEM) stereo-pairs. Examples are shown from samples of a creep-deformed monocrystalline Ni-base superalloy.
We report on the in situ investigation of mechanochemical syntheses of metal phosphonates. The metal phosphonates are formed in milling reactions starting from a metal acetate and a phosphonic acid. The conversions are observed by synchrotron PXRD and Raman spectroscopy to shed light on the reaction mechanisms including possible intermediates.
New fluorinated alkaline earth metal−organic frameworks were successfully synthesized by milling of metal hydroxides M(OH)2 with tetrafluoroterephthalic acid H2 pBDC-F4. Both calcium- and strontium-tetrafluoroterephthalates are tetrahydrated, while the barium tetrafluoroterephthalate is free of coordinating water molecules. The two isomorphic structures Ca(pBDC-F4)·4H2O and Sr(pBDC-F4)·4H2O were solved from the powder diffraction data by ab initio structure determination and subsequent Rietveld refinement. The products were thoroughly characterized by elemental analysis, thermal analysis, magicangle spinning NMR, Fourier transform infrared spectroscopy, scanning electron microscopy imaging, and Brunauer−Emmett−Teller measurements. Our findings suggest that the mechanochemical synthesis route is a promising approach for the preparation of new fluorinated alkaline earth metal−organic frameworks.
Im Bauwesen werden Polymerbeschichtungen häufig eingesetzt um einerseits ein bestimmtes Aussehens zu schaffen oder andererseits das Bauteil vor Alterung, Verschleiß oder Schädigung zu schützen. Bei praktisch allen Arbeitszielen ist deren Wirkung von der eigens dafür definierten Schichtdicke der Polymerbeschichtung abhängig. Daher wird die Dicke der Beschichtung nach erfolgtem Schichtauftrag überprüft. Für den in diesem Zusammenhang anspruchsvollen mineralischen Untergrund Beton stehen bislang allerdings nur zerstörende Prüfverfahren zur Verfügung. Aus diesem Grund soll im Rahmen des Projektes in Kollaboration mit der IBOS GmbH ein auf aktiver Thermografie basierendes Verfahren sowie ein Gerät für den vor-Ort-Einsatz entwickelt werden, mit dessen Hilfe eine zerstörungsfreie Schichtdickenbestimmung möglich ist.
Der Vortrag gibt einen kurzen Überblick über die Schichtdickenbestimmung mit Hilfe aktiver Thermografie und erläutert die speziellen Herausforderungen an die Thermografie für die in diesem Projekt zu charakterisierenden Polymerwerkstoffe. Zudem wird auf die Anforderungen an die zu entwickelnde Methode, den aktuellen Stand der Entwicklung sowie auf erste Ergebnisse des Projektes eingegangen.