Analytische Chemie
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (39) (entfernen)
Sprache
- Englisch (34)
- Deutsch (4)
- Mehrsprachig (1)
Schlagworte
- Nano aerial robot (6)
- RFID sensors (4)
- Structural health monitoring (4)
- Swarm (4)
- Electronic nose (3)
- Mobile Robot Olfaction (3)
- Wireless sensors (3)
- Air quality (2)
- Air quality monitoring (2)
- Drop test (2)
- Embedded sensor (2)
- Embedded sensors (2)
- Energy harvesting (2)
- Environment (2)
- Gas sensing (2)
- Gas sensors (2)
- Indoor air quality (2)
- LoRaWAN (2)
- Localization (2)
- Long term monitoring (2)
- Magnetic field (2)
- Multisensor system (2)
- Smart structures (2)
- Spectroscopy (2)
- Trail detection (2)
- Trail following (2)
- Transmission characteristics (2)
- VOC (2)
- Accelerometer (1)
- Actuators (1)
- Aerial robot olfaction (1)
- Ammonia gas sensor (1)
- Autonomous micro UAV (1)
- Bauteilmonitoring (1)
- Biologically inspired robots (1)
- Calibration of electrical quantities (1)
- Calibration of force (1)
- Calibration of temperature (1)
- Chemometric techniques (1)
- Concrete (1)
- Distributed linear sensor (1)
- DuraBASt (1)
- Eindringmodul (1)
- Embedded (1)
- Embedded system (1)
- Emmbedded sensor (1)
- Environmental analysis (1)
- Faser-Bragg Gitter (1)
- Fiber Bragg grating (1)
- Fiber Bragg gratings (1)
- Fiber bragg grating (1)
- Field conditions (1)
- Finite element methods (1)
- Fluorescence (1)
- Fluorescent sensor (1)
- Fluoreszenzlöschung (1)
- GC-MS (1)
- Gas detection (1)
- Gas detector (1)
- Gas dispersion simulation (1)
- Gas distribution mapping and gas source localization (1)
- Gas source localization (1)
- Gas storage areas (1)
- High impact shock application (1)
- Hopkinson bar (1)
- Humidity sensors (1)
- Härtevergleichsplatten (1)
- Indoor Localization (1)
- Instrumentierte Eindringprüfung (1)
- Kraftabhängige Funktion (1)
- Leak detection (1)
- Localization of gas sources (1)
- Magneto-optischer Sensor (1)
- Magnetostriction (1)
- Magnetostrictive metal coating (1)
- Magnetostriktive Beschichtung (1)
- Maschinennachgiebigkeit (1)
- Measurement uncertainty (1)
- Membrane-based gas sensing (1)
- Membrane-based linear gas sensor (1)
- Metal oxide semiconductor (1)
- Miniaturized sensor device (1)
- Mobile Robot (1)
- Mobile robot olfaction (1)
- Modeling and simulation (1)
- Moisture (1)
- Moisture measurements (1)
- Monitoring (1)
- Multi sensor device (1)
- NDT Inspection (1)
- Nano UAV Swarm (1)
- New sensor principles (1)
- Nitroaromaten (1)
- Oil (1)
- Passive RFID (1)
- Passive sensors (1)
- Pattern recognition methods (1)
- Piezoresistive accelerometer (1)
- Pump control (1)
- RFID based sensors (1)
- RFID-based sensors (1)
- Reactive plume tracking (1)
- Remote gas sensor model (1)
- SHM (1)
- Selbstkalibrierung (1)
- Self-diagnostic fiber optical sensor (1)
- Sensor (1)
- Sensors (1)
- Sensors in concrete (1)
- Setup and Validation (1)
- Smart sensors (1)
- Soil test field (1)
- Sphärische Indenter (1)
- Standard gas generator (1)
- Strain (1)
- Structure health monitoring (1)
- Subsurface monitoring (1)
- TDLAS (1)
- Temperature behavior (1)
- Temperature characteristics (1)
- Tomographic reconstruction of gas plumes (1)
- Tunable Diode Laser Absorption Spectroscopy (TDLAS); UAV-REGAS (1)
- Urban air monitoring (1)
- Vereinfachtes Verfahren (1)
- Water quality (1)
- WiFi (1)
- Wireless mobile sensor device (1)
- agricultural economy (1)
- embedded sensor (1)
- environment (1)
- fluorescence (1)
- gas analysis (1)
- poultry odorous air monitoring (1)
- spectroscopy (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (23)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (23)
- 1 Analytische Chemie; Referenzmaterialien (4)
- 1.9 Chemische und optische Sensorik (4)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 6 Materialchemie (1)
- 6.7 Materialsynthese und Design (1)
- 8.0 Abteilungsleitung und andere (1)
- 8.6 Faseroptische Sensorik (1)
- VP Vizepräsident (1)
- VP.2 Informationstechnik (1)
Temperature characteristics of a piezoresistive accelerometer for high impact shock application
(2018)
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
Long-term completely embedded sensor systems offer innovative possibilities for structural health monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors. This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external reader device. To evaluate characteristics and conditions of this concept, a systematical investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.
Embedded wireless sensor systems for long-term SHM and corrosion detection in concrete components
(2017)
State-of-the-art communication standards like RFID and Bluetooth Low Energy enable the development of sensor systems which can be completely embedded into concrete components for long-term SHM and early damage detection. Objective of the project KonSens which is carried out at BAM is the development, implementation, and validation of sensors for measuring of Parameters relevant for corrosion, like moisture, pH value, and electrical conductivity, inside steel reinforced concrete components. The primarily addressed application is detection and evaluation of corrosion processes in concrete bridges.
In contrast to cable connected sensors, embedded wireless sensors avoid any pathways for intrusion of moisture and chemicals, e.g., chlorides which could trigger corrosion activity. To allow for long-term, ideally life-time operation, the once embedded sensor systems must work highly energy efficient. One option are passive RFID sensor systems, which work without battery. The energy is transmitted to the system through the electromagnetic field, even to operate sensors. A crucial parameter is the transmission depth in concrete. First experiments with RFID sensors working at frequencies of 13.56 MHz (HF) and 868 MHz (UHF) embedded in concrete specimen resulted positive for transmission depths of up to 13 cm, which is quite promising, considering that corrosion would appear first at the top level of rebars.
A second generation of passive RFID sensor systems has been implemented with improved antenna design. Current experiments using these systems focus on the Transmission characteristics in terms of transmission depths and the impact of concrete moisture. Low-energy humidity sensors are used and analysed regarding their capability for measuring the material moisture. Additionally, a relation between transmitted power to the embedded sensor and the moisture content of the concrete specimen caused by energy absorption can be presumed and is under systematic investigation.
Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration.
Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity.
This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g.
This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C.
In Glasfasern eingeschriebene Bragg-Gitter (FBG: fibre-based Bragg gratings) sind über die Verschiebung der Bragg-Wellenlänge in der Lage, Stauchungen und Dehnungen von Glasfasern hochgenau zu erfassen. In Kompositwerkstoffe eingebettete faseroptische Sensoren können Bauteile bezüglich ihrer mechanischen Integrität überwachen und früh-zeitig Informationen über Materialveränderungen gewinnen.
Um die Zuverlässigkeit eines solchen Sensors zu gewährleisten, ist es wichtig, die korrekte Funktion des Sensors im Verbund mit der Werkstoff-Matrix on-line und in-situ sicherzu-stellen. Im Rahmen des DFG-Projekts FAMOS² (FAser-basierter Magneto-Optischer SchichtSensor) wurde ein selbstdiagnosefähiger Schichtsensor entwickelt, der mit Hilfe von magnetostriktiven Aktorschichten aus Nickel bzw. Eisen-Nickel validiert werden kann.
Der FAMOS²-Schichtsensor wird durch ein PVD (physical vapour deposition)/ECD (electro-chemical deposition) Hybridschichtsystem realisiert, das auf dem Fasermantel im Bereich des FBG haftfest, homogen und langzeitfunktional abzuscheiden ist. Dabei wird in einem ersten Schritt ein etwa 100 Nanometer dünnes PVD-Schichtsystem aus Chrom und Kupfer als Haftvermittler auf der Glasfaser bzw. als leitfähige Startschicht für den nachfolgenden ECD-Prozess abgeschieden. Um eine rotationssymmetrische Schich-tabscheidung zu gewährleisten, erfolgt während der PVD-Beschichtung eine Rotation der Glasfasern. In einem zweiten Schritt wird dann unter Verwendung eines klassischen Watts-Elektrolyten in einer speziell entwickelten ebenfalls rotationssymmetrisch aufgebau-ten ECD-Durchströmungszelle dann die etwa 30 Mikrometer dicke, magnetostriktive Ak-torschicht auf dem PVD-Schichtsystem abgeschieden, im Vergleich sowohl reine Nickel-Schichten als auch Nickel-Eisen-Schichten.
Ein äußeres Magnetfeld dehnt die magnetostriktive Aktorschicht und damit auch die Faser reversibel. Diese Dehnung führt zu einer Verschiebung der Bragg-Wellenlänge, welche direkt mit der Stärke eines zu messenden oder zu Validierungszwecken vorgegebenen Magnetfeldes korreliert. Die Anpassung der Beschichtungsverfahren an die Fasergeome-trie und die mechanischen Eigenschaften der Hybridschichten werden hinsichtlich der me-chanischen Integrität des faseroptischen Sensors diskutiert und der Nachweis der Selbst-diagnosefähigkeit erbracht.
The present paper describes the development of a sensor material that changes its fluorescence in the presence of gaseous ammonia in a relevant concentration range. The implementation into a semi-automatic gas measurement device enables low-cost, precise, simple and fast monitoring of low con-centrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.
In the present paper the development of a semi-automated device for long-term monitoring of gaseous ammonia is described. A sensor material was produced that changes its optical properties in the pres-ence of low concentrations of ammonia in air. The implementation into an electronic device enables precise, simple, economic and fast monitoring of low concentrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.
Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.
Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or hardly accessible areas. A challenging task, however, is the generation of threedimensional distribution maps from these gas measurements.
Suitable reconstruction algorithms can be adapted, for instance, from the field of computed tomography (CT), but both their performance and strategies for selecting optimal measuring poses must be evaluated. For this purpose simulations are used, since, in contrast to field tests, they allow repeatable conditions. Although several simulation tools exist, they lack realistic models of remote gas sensors. Recently, we introduced a model for a Tunable Diode Laser Absorption Spectroscopy (TDLAS) gas sensor taking into account the conical shape of its laser beam. However, the novel model has not yet been validated with experiments. In this paper, we compare our model with a real sensor device and show that the assumptions made hold.