Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (119)
- Zeitschriftenartikel (65)
- Posterpräsentation (36)
- Beitrag zu einem Tagungsband (7)
- Sonstiges (4)
- Buchkapitel (3)
- Dissertation (3)
- Forschungsdatensatz (3)
- Monografie (1)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (162)
- Deutsch (79)
- Mehrsprachig (4)
Schlagworte
- Process Analytical Technology (38)
- Prozessanalytik (32)
- Prozessindustrie (29)
- CONSENS (22)
- Online NMR Spectroscopy (22)
- Digitalisierung (16)
- Benchtop-NMR (15)
- NMR spectroscopy (15)
- Process analytical technology (15)
- Industrie 4.0 (14)
Organisationseinheit der BAM
- 1.4 Prozessanalytik (245) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (119)
Changes in the global bulk and local structures, of three different barium compounds (BaZrO3, BaF2, and BaFCl),were induced by mechanical milling and followed using X-ray powder diffraction (PXRD), subsequent microstructure analysis, and 137Ba solid state NMR spectroscopy. Harder materials like BaZrO3 experience significantly higher structural changes upon milling than softer materials like BaF2. Moreover, soft materials with layered structures, like BaFCl, show a pronounced structural change during the milling process. By combining PXRD and solid state NMR, detailed information on the changes to the global and local structures were obtained, which are of interest for mechanochemical synthesis, mechanically treated catalysts or ionic conductors.
Spatial heterodyne spectroscopy (SHS) is a novel spectral analysis technique that is being applied for Raman spectroscopy of minerals. This paper presents the theoretical basis of SHS and its application for Raman measurements of calcite, quartz and forsterite in marble, copper ore and nickel ore, respectively. The SHS measurements are done using a broadband (518–686 nm) and resolving power R ≈ 3000 instrument. The spectra obtained using SHS are compared to those obtained by benchtop and modular dispersive spectrometers. It is found that SHRS performance in terms of resolution is comparable to that of the benchtop spectrometer and better than the modular dispersive spectrometer, while the sensitivity of SHRS is worse than that of a benchtop spectrometer, but better than that of a modular dispersive spectrometer. When considered that SHS components are small and can be packaged into a handheld device, there is interest in developing an SHS-based Instrument for mobile Raman spectroscopy. This paper evaluates the possibility of such an application.
We present a versatile and simple method using electrochemistry for the exclusive functionalization of the edge of a graphene monolayer with metal nanoparticles or polymeric amino groups. The attachment of metal nanoparticles allows us to exploit surface-enhanced Raman scattering to characterize the chemistry of both the pristine and the functionalized graphene edge. For the pristine patterned graphene edge, we observe the typical edge-related modes, while for the functionalized graphene edge we identify the chemical structure of the functional layer by vibrational fingerprinting. The ability to obtain single selectively functionalized graphene edges routinely on an insulating substrate opens an avenue for exploring the effect of edge chemistry on graphene properties systematically.
The CCQM-K148.a comparison was coordinated by the BIPM on behalf of the CCQM Organic Analysis Working Group for NMIs and DIs which provide measurement services in organic analysis under the CIPM MRA. It was undertaken as a "Track A" comparison within the OAWG strategic plan. CCQM-K148.a demonstrates capabilities for assigning the mass fraction content of a solid organic compound having moderate molecular complexity, where the compound has a molar mass in the range (75 - 500) g/mol and is non-polar (pKow < −2), when present as the primary organic component in a neat organic solid and where the mass fraction content of the primary component in the material is in excess of 950 mg/g.
Participants were required to report the mass fraction of Bisphenol A present in one supplied unit of the comparison material. Participants using a mass balance method for the assignment were also required to report their assignments of the impurity components present in the material. Methods used by the seventeen participating NMIs or DIs were predominantly based on either stand-alone mass balance (summation of impurities) or qNMR approaches, or the combination of data obtained using both methods. The results obtained using thermal methods based on freezing-point depression methods were also reported by a limited number of participants. There was excellent agreement between assignments obtained using all three approaches to assign the BPA content.
The assignment of the values for the mass fraction content of BPA consistent with the KCRV was achieved by most of the comparison participants with an associated relative standard uncertainty in the assigned value in the range (0.1 - 0.5)%.
Exploratory analysis of hyperspectral FTIR data obtained from environmental microplastics samples
(2020)
Hyperspectral imaging of environmental samples with infrared microscopes is one of the preferred methods to find and characterize microplastics. Particles can be quantified in terms of number, size and size distribution. Their shape can be studied and the substances can be identified. Interpretation of the collected spectra is a typical problem encountered during the analysis. The image datasets are large and contain spectra of countless particles of natural and synthetic origin. To supplement existing Analysis pipelines, exploratory multivariate data analysis was tested on two independent datasets. Dimensionality reduction with principal component analysis (PCA) and uniform manifold approximation and projection (UMAP) was used as a core concept. It allowed for improved visual accessibility of the data and created a chemical two-dimensional image of the sample. Spectra belonging to particles could be separated from blank spectra, reducing the amount of data significantly. Selected spectra were further studied, also applying PCA and UMAP. Groups of similar spectra were identified by cluster analysis using k-means, density based, and interactive manual clustering. Most clusters could be assigned to chemical species based on reference spectra. While the results support findings obtained with a ‘targeted analysis’ based on automated library search, exploratory analysis points the attention towards the group of unidientified spectra that remained and are otherwise easily overlooked.
Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and high-throughput mass quantification of micro¬plastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermo-analytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg. The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most compact NIR spectrometers available.
Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and highthroughput mass quantification of microplastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermoanalytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg.
The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most
compact NIR spectrometers available.
µ-FTIR spectroscopy is a widely used technique in microplastics research. It allows to simultaneously characterize the material of the small particles, fibers or fragments, and to specify their size distribution and shape. Modern detectors offer the possibility to perform two-dimensional imaging of the sample providing detailed information. However, datasets are often too large for manual evaluation calling for automated microplastic identification. Library search based on the comparison with known reference spectra has been proposed to solve this problem.
To supplement this ‘targeted analysis’, an exploratory approach was tested. Principal component analysis (PCA) was used to drastically reduce the size of the data set while maintaining the significant information. Groups of similar spectra in the prepared data set were identified with cluster analysis. Members of different clusters could be assigned to different polymer types whereas the variation observed within a cluster gives a hint on the chemical variability of microplastics of the same type. Spectra labeled according to the respective cluster can be used for supervised learning. The obtained classification was tested on an independent data set and results were compared to the spectral library search approach.
Working towards a comprehensive understanding of introduction pathways, number, and fate of micro¬plastics in the environment, suitable analytical methods are a precondition. Micro-spectroscopic methods are probably the most widely used techniques. Besides their ability to measure single spectra of a particle or fiber, most modern FTIR- and Raman microscopes are also capable of two-dimensional imaging. This is very appealing to microplastics research because it allows to simultaneously characterize the analytes chemically as well as their size (distribution) and shape.
Two-dimensional imaging on extensive sample areas with FTIR-micros¬copes is facilitated by focal plane array (FPA) detectors resulting in large data sets comprised of up to several million spectra. With numbers too large for manual inspection of each individual spectrum, automated data evaluation is inevitable. Identifying different polymers based on the comparison with known reference spectra (library search) has proven to be a suitable approach. For that purpose, FTIR-spectra of common plastics can be collected to create an individual reference library.
To Supplement this ‘targeted analysis’, looking for known substances via library search, an exploratory approach was tested. Principal component analysis (PCA) proved to be a helpful tool to drastically reduce the size of the data set while maintaining the significant information. Subsequently, cluster analysis was used to find groups of similar spectra. Spectra found in different clusters could be assigned to different polymer types. The variation observed within clusters gives a hint on chemical variability of microplastics of the same polymer found in the sample. Spectra labeled according to the respective cluster/polymer type were used to build a classification model which allowed to quickly predict the polymer type based on the FTIR spectrum. Classification was tested on a second, independent data set and results were compared to the spectral library search procedure.
Process monitoring with online NMR spectroscopy – An enabler for “Industrie 4.0” in process industry
(2018)
Improvement in deep process understanding is a mandatory prerequisite for the application of modern concepts like Industrial Internet of Things (IIoT) or “Industrie 4.0”. This is particularly relevant in new process concepts such as intensified production in modularized plants. The direct hyphenation with online methods of process analytical technology (PAT) allows profound insights into the actual reactions within chemical and pharmaceutical production steps and provides necessary information for associated control strategies.
While the industrial application of online Raman spectroscopy has already been successfully demonstrated, low-field NMR spectroscopy is not yet adequately developed as an online method for use in process industry. The high information content combined with the low calibration effort makes NMR spectroscopy a highly promising method for modern process automation with a high flexibility due to short set-up times and low requirements regarding validation. This is a major advantage especially within multi-purpose production plants, as well as for processes suffering from fluctuating quality of raw materials. NMR spectroscopy has a high potential for direct quantitative information, while cutting the calibration and validation needs to a minimum and thus exhibiting short set-up times.
Within the EU project CONSENS, an NMR analyzer for direct implementation in an industrial process environment was developed based on a commercially available laboratory instrument. The challenge was not only the hyphenation to the production plant itself, but also to fulfill all requirements of chemical industry, e.g., explosion safety regulations (ATEX), robust automation and modern, as well as classical communication interfaces. The presented NMR module involves a compact spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction), and evaluation. The module transforms the acquired online spectra of various technically relevant reactions to either conventional 4‒20 mA signals as well as WiFi based OPC-UA communication protocols.
The concept was evaluated on two processes of pharmaceutical and chemical industry. As the first example the continuous synthesis of 2-nitrodiphenylamine starting from aniline and o-fluoronitrobenzene, activated by an organometallic lithium reagent, was studied. This application is highly demanding for a reliable automated evaluation of the obtained NMR spectra, which was realized by developing a physically motivated model-based approach.
In the second example, a stage of the synthesis of the industrially important solvent tetrahydrofurane consisting of the catalytic hydrogenation of 2-butine-1,4-diol was monitored. This reaction is proceeding via an intermediate product and suffers from competitive reaction paths. In this application different spectroscopic methods were combined with the data obtained from classical process sensors, e.g., pressure, temperature and flow transducers for the development of innovative control concepts.