Analytische Chemie
Filtern
Erscheinungsjahr
- 2015 (15) (entfernen)
Dokumenttyp
- Posterpräsentation (15) (entfernen)
Referierte Publikation
- nein (15)
Schlagworte
- PFOA (2)
- PFOS (2)
- 19F-NMR (1)
- 1H-NMR (1)
- AFM (1)
- Analyses of inks (1)
- Arzneimittelrückstände in Oberflächenwasserproben (1)
- Benchtop NMR Spectroscopy (1)
- CRM (1)
- Carbamazepin (1)
Fraunhofer Life Science Day
(2015)
Their high affinity, selectivity and specificity make monoclonal antibodies (mAbs) very important tools in research, diagnostics and therapy. The production of mAbs is routinely performed by hybridoma technique. Hybridomas are generated by fusing antibody-producing B cells with indefinitely proliferating myeloma cells. Both, cell fusion and the indispensable identification and isolation of the desired antibody-producing hybridoma clone is still far from being trivial.
We describe a novel method that should help to optimize the cell fusion, and the screening for antibody-secreting hapten-specific hybridoma cells by using fluorescence activated cell sorting and single-cell fusion. Hybridoma cells specific for a hapten were incubated with a hapten-peroxidase conjugate (hapten-HRP), which was subsequently incubated with a fluorophore-labeled polyclonal anti-peroxidase antibody (anti-HRP-Alexa Fluor® 488). To characterize the expression of membrane-bound immunoglobulin G (IgG) a fluorophore-labeled anti-mouse IgG antibody (anti-IgG-Alexa Fluor® 647) was used. Successful staining was verified by confocal laser scanning microscopy (CLSM). We show that it is possible to specifically label hapten-specific hybridoma cells. It should also be possible to use this labelling approach for the isolation of hapten-specific B cells from the spleen and use these cells for single-cell fusion. Parallelized cell fusion chips were developed to increase fusion efficiencies.
Surface-enhanced Raman scattering (SERS) exploits the enhancement of electromagnetic fields in close vicinity of plasmonic nanostructures, enabling characterization of analytes at the single-molecule level. The nanometer-scale spatial arrangement of plasmonic metal nanoparticles and analyte molecules has a significant effect on the observed signal enhancements and represents a great challenge in this technique.
In our work, DNA origami is used as platform for precise positioning of gold nanoparticles (AuNPs). Especially high sensitivities are expected for gold nanolenses (AuNLs), consisting of rows of three or more differently-sized AuNPs. We assembled different AuNL designs and determined respective SERS enhancement factors by collecting Raman spectra from single AuNLs. Finite difference time domain calculations estimate attainable electromagnetic field enhancements. Ultimately, we aim to develop a versatile platform for various SERS applications.
Interfaces provide the structural basis for function as, for example, encountered in nature in the membrane-embedded photosystem or in technology in solar cells. Synthetic functional multilayers of molecules cooperating in a coupled manner can be fabricated on surfaces through layer-by-layer self-assembly. Ordered arrays of stimuli-responsive rotaxanes undergoing well-controlled axle shuttling are excellent candidates for coupled mechanical motion. Such stimuli-responsive surfaces may help integrating synthetic molecular machines in larger systems exhibiting even macroscopic effects or generating mechanical work from chemical energy through cooperative action. The present work demonstrates the successful deposition of ordered mono- and multilayers of chemically switchable rotaxanes on gold surfaces. For the first time, rotaxane mono- and multilayers are shown to reversibly switch in a coupled manner between two ordered states as revealed by linear dichroism effects in angle-resolved NEXAFS spectra. Such a concerted switching process is observed only when the surfaces are well packed, while less densely packed surfaces lacking lateral order do not exhibit such effects.
N4-acetyl-SMX is the most important cross-reacting compound for the SMX-ELISA with concentrations of 1064 - 2488 ng/L in influent wastewater and 40 - 160 ng/L in effluent wastewater.
The ELISAgrams for estrone show less interfering signals than for SMX.
ELISAgrams of SMX and estrone display in effluent wastewater more interfering signals than in influent wastewater.
Here, we summerize our efforts concerning new design concepts and examples for fluorescence standards that can provide traceability to radiometric units and present a first step towards a toolbox of fluorescence standards, currently consisting of:
i) A first set of liquid fluorescence standards enables the determination of a broad variety of fluorescence parameters was developed and certified by BAM and is distributed by Sigma-Aldrich.
ii) Ready-to-use, glass-based fluorescence standards for instrument performance validation (IPV) and determination instrument-to-instrument variations can also be used as wavelength standard for fluorescence instruments with low requirements on spectral resolution and allow monitoring of temporal changes of the wavelength-dependent spectral responsivity.
iii) Novel calibration tools and validation concepts for microarray-based platforms used in molecular diagnostics and food safety control.
iv) We currently develop reference materials, which can be used as reliable quantum yield standards for relative methods for the determination of QY and can be valuable in the evaluation of the performance and sources of uncertainty of absolute, standard-free methods using e.g. integrating spheres.
Reliable analysis of chemical indicators in water, sediment and soil samples for the purpose of environmental pollution assessment poses one of the greatest analytical challenges, having in mind the complexity of sample matrix and low concentrations of pollutants. Organics (pesticides, PAHs, PCBs, etc.) and heavy metals (Hg, Cd, Ni, Pb and As) represent target parameters. Laboratories performing sampling and tests in this field regulated by respective EU directives, need strong support in terms of providing them with appropriate matrix CRMs enabling the process of quality control. NMIs and DIs with proven metrological capabilities for the production and certification of such materials are necessary for the provision of quality data. This project is aiming to develop capacity to produce CRMs for environmental analysis by transferring the theoretical and practical know-how between the partners and combining their skills to focus on environmental CRM production in accordance with ISO Guide 34. Production process includes good manufacturing practices for processing materials, method development and validation for homogeneity, stability and characterisation tests, characterisation of selected analytes together with additional information about matrix constituents, the calculation of individual uncertainties (between units inhomogeneity, long term stability, characterisation) and combination of uncertainties to determine overall uncertainty of the matrix reference materials. Inter laboratory comparison registered as EURAMET project is set as the ultimate project outcome, confirming the partners’ capabilities in applying newly acquired skills.
This project aims to develop capacity to produce certified reference materials (CRMs) for environmental analysis by transferring know-how between the partners and combining their skills to focus on environmental CRM production. The production process includes good manufacturing practices for processing materials, method development, the validation and application of homogeneity, stability and characterisation tests, the calculation of individual uncertainties (between-unit inhomogeneity, long term stability, characterisation) and combination of uncertainties to determine overall uncertainty of the matrix reference materials. An inter laboratory comparison registered as a EURAMET project is set as the ultimate project outcome, confirming the partners’ capabilities in applying newly acquired skills.
Zur Bestimmung von Arzneimittelrückständen in Oberflächengewässern wird häufig die LC-MS/MS als Methode der Wahl eingesetzt. Obwohl sich dieses Nachweisverfahren durch eine hohe Empfindlichkeit und Selektivität auszeichnet, gibt es vor allem bei geringen Substanzkonzentrationen häufig störende Einflüsse durch Matrixeffekte. Diese Matrixeffekte können unterschiedliche Ursachen haben.
Einige Matrixeffekte werden am Beispiel des Wirkstoffs Carbamazepin erläutert. Carbamazepin wird durch Kläranlagen nur partiell aus dem Abwasser entfernt und ist im Spurenbereich auch noch im Trinkwasser nachzuweisen. Wenn für die LC-MS/MS wasserbasierte Anteile in der mobilen Phase genutzt werden, befinden sich trotz Verwendung einer Labor-Reinstwasseranlage in der mobilen Phase noch kleinste Konzentrationen von Carbamazepin, welche einen Blindwert im unteren ppt-Bereich verursachen.
Weitere Matrixeffekte treten durch die unterschiedliche Qualität der Oberflächenwasserproben auf. Koelutionen von weiteren Inhaltstoffen zeitgleich mit dem Zielanalyten führen zu einer Diskriminierung des Meßsignals. Verbindungen, die den gleichen Massenübergang bei nahezu identischer Retentionszeit zeigen, erfordern eine reproduzierbare chromatographische Vortrennung oder die Wahl einer alternativen HPLC-Säule.
Gravimetrically prepared mono-elemental reference solutions having a well-known mass fraction of approximately 1 g/kg define the very basis of virtually all measurements in inorganic analysis. Serving as the starting materials of all standard/calibration solutions, they link virtually all measurements of inorganic analytes to the purity of the solid materials they were prepared from. In case these solid materials are characterized comprehensively with respect to their purity, this link also establishes direct metrological traceability to The International System of Unit. Within the framework of the European Metrology Research Programme (EMRP), in the Joint Research Project called SIB09 Primary standards for challenging elements, a reference solution of molybdenum was prepared directly from the respective metal with a relative expanded uncertainty associated with the mass fraction of Urel(w) < 0.05 %. A highly accurate and precise ICP OES and MC-ICP-MS method was developed to assist with the preparation and as a dissemination tool.
One of the most important collections of manuscripts and wall paintings from sites of the northern Silk Road, discovered at the beginning of the 20thC, are deposited in Berlin. The fragments represent a broad spectrum of scripts, languages, and painting styles depending on the region of origin and purpose of dissemination. The manufacturing material reflects the various influences in the oasis sites. Based on analyses of some pigments, examples are posed.