Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (5)
- Zeitschriftenartikel (4)
- Posterpräsentation (4)
- Handbuch (1)
- Vortrag (1)
Schlagworte
- Moisture (3)
- Screed (3)
- Zerstörungsfreie Prüfung (3)
- Estrich (2)
- Microwave (2)
- NMR (2)
- Non-destructive testing (2)
- Procedure (2)
- Quality assurance (2)
- Reference specimen (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
Information about an existing structure can be collected at certain costs to evaluate the reliability and condition as realistically as necessary. This information can be relevant or irrelevant, true or biased, precise or imprecise. The incorporation of relevant and quality-assessed measured information into reliability reassessment offers the chance to extend remaining lifetimes and support decision making about optimal actions or maintenance strategies. This paper shows recent developments in a national research project that aims to produce a guideline on the NDT-based, structure-specific modification of partial safety factors. The general methodology, results from recalculations according to the Eurocodes and metrologically solvable testing tasks relevant in the recalculation of the concrete bridges are shown and compared with the non-destructive testing methods applicable to concrete bridges. A case study is used to demonstrate that as-built drawings, in this case of the positions of tendons and shear reinforcement, can be verified using the radar method.
The process of ensuring reliability of NDT applications contains various aspects, such as determining the performance and probability of success, the uncertainty in measurement, the provision of clear and functional procedures and ensuring the correct application accordingly. Test specimens have become powerful elements in supporting many of these aspects. Within the committee for NDT in Civil Engineering (NDT-CE) of the German Society for Nondestructive Testing (DGZfP), the subcommittee on Quality Assurance (UA-QS) therefore addresses the design and the integration of test specimens in the quality assurance process. Depending on the specific purpose, the requirements on test specimens can vary significantly based on the defined simulated scenario. The most prominent purposes of test specimens might be seen in providing references for inspection systems in regard to function control, calibration and validation. Further aspects can be parametric studies, basic investigation of physical principles related to NDT or a simplified and therefore comprehensive demonstration of inspection concepts (e.g. for teaching purposes). The specific purpose of a test specimen dictates the requirements regarding its conception, including the exact design, the material or the fabrication accuracy and the conditioning. In the development of a general guideline by the UA-QS for application-specific procedures and their validation, the use of test specimens is addressed and specific concepts for the design of test specimens are made. This includes the analysis of the measurement process regarding any given application, deriving an adequate calibration approach for it and designing test specimens (calibration specimens) accordingly. Furthermore, it includes the validation of the procedure taking into account all conditions related to the specific application in the field. The validation requires a statistically sufficient number of trials. Thorough evaluation of each trial can only be established if the ground-truth is known. Therefore, test specimens providing a realistic but controlled simulation of the inspection problem are valuable and indispensable elements in the validation process. The requirement of being fully realistic will often not be possible to fulfill due to practical restrictions. Any aspect that cannot be included in the simulation realistically needs to be simulated conservatively. This again, requires a sufficient understanding of the inspection principle and technique to ensure conservativeness. Among other quality-assurance-related aspects, the UA-QS establishes concepts and guidelines regarding sound and efficient approaches for the specific purposes of test specimens. This subcommittee brings together representatives of different Groups along the entire value chain of NDT-CE, including researchers, practitioners, manufacturers and clients. They all work together in establishing a common understanding and level of quality assurance in the industry.
The field of non-destructive testing of civil structures (NDT-CE) has been continuously growing. Due to the complexity and diversity of civil constructions as well as the heterogeneity of concrete, specific standards or guidelines for the application of modern NDT-CE are still missing. The development of individual solutions is the current approach, which is just as challenging as it is common for NDT-CE.
With the increasing development and commercialization of NDT-CE technology, the group of practitioners is growing. To ensure a good level of quality in the industry, it appears necessary to establish adequate means.
Naturally, the performance of NDT-CE methods regarding a specific application is strongly dependent on choosing the most suitable inspection technique and applying it correctly, generally referred to as the inspection procedure in the field of NDT. There are well-defined guidelines regarding procedure documentation and handling in many fields of NDT (e.g. nuclear, aerospace or automotive) according to the high importance of procedures in assuring a successful and reliable application. For a long time, this has not always been the case with NDT-CE, which is still considered a unique discipline of NDT. Part of the reason for that might be the young development state of NDTCE, the heterogeneity of building materials like concrete, timber or masonry as a material and the diversity of civil structures. In consequence, NDT-CE procedure development is considered challenging.
Among other aspects, addressed in the subcommittee on Quality Assurance (UA-QS) within the committee for NDT-CE of the German Society for Nondestructive Testing (DGZfP), part of its work aims at establishing an adequate basis for NDT-CE procedure development. While some of the highly developed approaches from other industries are taken into consideration, they need to be analyzed regarding their suitability for NDT-CE and adapted accordingly. For a procedure to be as defined as possible, it needs to contain sufficient information, such as the scope and limitations regarding material, geometry and condition of the test object, inspection parameters, calibration, data acquisition, analysis criteria as well as requirements regarding the inspection personnel.
For a successful implementation in the field, it is important to define the specific procedure as precisely as possible. Despite the necessity of a great amount of information to be included, the procedure needs to be suitable for efficient field application.
The UA-QS is developing a guideline for NDT-CE procedures suitable for application in this field of NDT to ensure correct and reproducible application. To demonstrate and evaluate this concept, specific examples of procedures are also produced. In particular, the UA-QS has developed a procedure for the detection and positioning of tendon ducts using Ground Penetrating Radar (GPR). This procedure is tested regarding the practical applicability in a roundrobin on a defined type of reference test block.
Post-tensioning systems provide safe and efficient construction solutions for long span bridges. Despite the improved grouting practices over the past decade, existing post-tensioning systems may have significant amount of grout defects, which could lead to corrosion of the strands. Condition assessment of post-tensioning systems is necessary to allow bridge owners to take timely, proactive actions to mitigate or prevent further Deterioration and unanticipated tendon failures. A detailed experimental study conducted to assess the performance of nondestructive evaluation techniques in detecting grout defects within internal tendons is presented herein.
Nondestructive evaluation techniques that include Ground Penetrating Radar, Impact Echo, Ultrasonic Tomography, and Ultrasonic Echo are evaluated in terms of detecting the location and severity of fabricated grout defects in a full-scale post-tensioned U-girder mock-up specimen. While Ground Penetrating Radar can identify the location and profile of the internal tendons, particularly metal ducts due to strong reflections, this method did not provide any information about the defect conditions within the tendon. Both Impact Echo and Ultrasonic Echo techniques are effective in identifying the Location of grout defects, but could not differentiate between water, void, or compromised grout conditions. The study clearly demonstrates the need for NDE techniques that are applicable to anchorage regions, and that are capable of estimating the severity and nature of grout defects in internal tendons.
Die Ermittlung der Belegreife von Fußbodenestrichen ist im Bauwesen von hoher Bedeutung,
da es bei dem Verlegen von Parkett oder anderen Bodenbelägen auf Estrichen zu erheblichen
feuchtigkeitsbedingten Schäden kommen kann, wenn diese noch nicht hinreichend
getrocknet sind. Für die Messung des Feuchtegehalts wird üblicherweise auf zerstörende
Methoden wie das Darr- und CM-Verfahren zurückgegriffen, die Probennahmen erfordern
und nur punktuelle Informationen liefern.
Ziel dieser Forschungsstudie ist die Untersuchung der Eignung und Anwendbarkeit des
Georadars und der Kernspinresonanz (NMR) zur zerstörungsfreien und flächendeckenden
Feuchtemessung von Estrichen. Dazu wurden Messungen mit beiden Verfahren an einer
Gruppe zementgebundener (CT) und einer Gruppe anhydritgebundener (CA) Estriche
während ihres Austrocknungsprozesses bei einem Konstant-Klima durchgeführt. Bei dem
Radarverfahren werden Amplitude und Laufzeit elektromagnetischer Reflexionen, die durch den Wassergehalt beeinflusst werden, gemessen. Die Radarmessungen erfolgten auf jeder
Probe entlang von zwei senkrechten Profilen mit einer 2GHz-Antenne. Die Kernspinresonanz
steht aufgrund ihrer Abhängigkeit zur magnetischen Kernresonanz der 1H-Wasserstoffatomen
in Relation mit dem Wassergehalt in dem Messvolumen der zu untersuchenden
Probe. Die Untersuchungen erfolgten mit dem NMR MOUSE System in Aufsatztechnik.
Dabei liegt die Eindringtiefe bei 24,8 mm.
Bei den Untersuchungen lässt sich für CT-Estriche ein starker vertikaler Feuchtegradient
feststellen. Die CA-Estriche weisen hingegen nur einen schwachen Feuchtegradienten bis
nahezu konstante Amplituden über die gesamte Tiefe auf. Nach Erreichen einer Amplitude
von ca. 5-8 lässt sich keine weitere Amplitudenveränderung registrieren bzw. sind ab diesen
Zeitpunkt die Änderungen im Wassergehalt zu gering, um von der NMR aufgelöst zu werden.
In den Ergebnissen des Radarverfahrens lässt sich ebenfalls ein von dem Feuchtegehalt
abhängiges Verhalten der Messparameter beobachten. Mit zunehmender Trocknung kann
man eine Abnahme der Laufzeit zwischen direkter und an der Rückwand reflektierter Welle
messen. Die Amplituden beider Wellen hingegen nehmen während des Austrocknungsprozesses
zu. Im Gegensatz zur NMR erhält man keine tiefenbezogenen Informationen.
Es lassen sich aber Rückschlüsse auf den Feuchtegehalt im Gesamtvolumen ziehen.
Die Bestimmung der Belegreife von Estrichen erfolgt im Bauwesen meist unter Verwendung von zerstörenden Verfahren, die Probenentnahmen erfordern und nur punktuelle Daten liefern. Bei anhydritgebundenen Estrichen gelten 0,5 M% und bei zementgebundenen ca. 3,5 M% und höher als belegreifer Feuchtegehalt. Die Belegreife wird als Feuchtegehalt in Masseprozent (M%) bezogen auf die Trockenmasse des Baustoffes angegeben. Zur zerstörungsfreien Feuchtemessung existieren verschiedene einfach zu bedienende Handgeräte, die u. a. auf elektrischen, elektromagnetischen und kapazitiven Methoden beruhen. In dieser Arbeit wurden ein kapazitives (Kugelsonde), ein elektromagnetisches (Mikrowellensensoren) und ein elektrisches Messverfahren (Vierelektroden-Sonde) untersucht. Mit Ausnahme der Vierelektroden-Sonde weisen die Handgeräte keine ausreichende Sensitivität in Bereichen niedriger Feuchtegehalte unterhalb von 1 M% auf und scheinen somit nicht für anhydritgebundene Estriche geeignet zu sein. Für zementgebundene Estriche lassen sich hingegen mit allen getesteten Geräten Änderungen in dem Bereich der Belegreife erfassen. In dieser Arbeit wird zusätzlich die Wasserabgabe in g/m²/Tag als Bezugsgröße herangezogen. Die Wasserabgabe stellt ein geeigneteres Maß für die Schadensträchtigkeit dar und ermöglicht direkte Vergleiche unabhängig von der verwendeten Estrichart. Für alle getesteten Estriche konnte eine Wasserabgabe von ca. 8-10 g/m²/Tag als Belegreifegrenzwert bestimmt werden.
Eight different screed types are tested including two different sample heights of 35 and 70 mm. The moisture of the four cement based and four sulphate based screeds are monitored during hydration and evaporation. All samples are stored in a climatic chamber at 23◦ C and 50 % relative humidity. Embedded sensors like temperature arrays, humidity sensor arrays, and multi-ring electrodes are embedded in the samples to yield a detailed moisture evolution with high depth resolution. Furthermore, nuclear magnetic resonance is used to quantify the water content at different depths. This multi-sensor approach allows a comprehensive monitoring of the moisture and its gradient in the different screed samples. This yields a deeper insight into the hydration, moisture convection, and diffusion processes.
We have compared the performance of the typical Darr and CM moisture testing techniques, which are destructive with several non-destructive testing techniques on two types of floor screeds. In case of cement based screeds these destructive tests failed to deliver reliable results. Moreover, our measurements indicate significantly different drying and moisture transport behavior for the investigated cement based and calcium-sulphate based screeds. Whereas we have strong with depth decreasing moisture gradients in the CT material, we observe in the penetrated volumes of our ndt methods basically no clear moisture gradient in the CA samples. The findings with ndt methods could be supported by moisture gradient studies with nuclear magnetic resonance measurements.
In den letzten Jahren hat sich das Impulsradar als zerstörungsfreies Prüfverfahren im Bauwesen insbesondere zur Ortung von metallischen Einbauteilen wie z. B. schlaffer und vorgespannter Bewehrung in Betonbauteilen immer stärker durchgesetzt.
Systematische Laboruntersuchungen und Fallstudien zeigen aber auch, dass das Verfahren sehr gut zur Ortung von Hohlstellen sowohl in Mauerwerk als auch in Betonstrukturen geeignet ist.
Das Radarverfahren arbeitet nach dem Impuls-Echo Prinzip. Dabei wird von der Sendeantenne ein sehr kurzer elektromagnetischer Impuls ausgesendet (ca. 3 Halbwellen), der an Grenzflächen im Material (Änderung der Dielektrizitätskonstanten) und bei nicht zu dicken Bauteilen auch an der Rückseite reflektiert und von der Empfangsantenne detektiert wird. Bei den hier vorgestellten Messergebnissen wurden eine 900 MHz sowie eine 1,5 GHz Antenne in Kombination mit einem kommerziellen Radargerät eingesetzt.