Faecal contaminants in water are considered serious threats for human health, due to the presence of viruses, bacteria and other harmful microorganisms.1 Urobilin (UB) is a well-known faecal pigment and can be used as a marker for faecal matter in water.2 UB is commonly present in the urine of all mammals as the catabolic end product of bilirubin degradation.2 As the only simple chemical approach to its detection, Schlesinger’s test is usually used to enhance the weak fluorescence of UB in alcoholic media by complexation with Zinc.2, 3 The major limitation of this method is the only weak enhancement of the intrinsically weak UB fluorescence in aqueous media.3 This work presents an approach to introduce different Zn salts for improved fluorescence response, where we found a clear dependence of the fluorescence yield of UB-Zn(II) complexes on the counterion of the salt in water. By employing a combination of fluorescence parameters like transition energy, fluorescence intensity, and fluorescence lifetime, a photophysical understanding of the structure and conformation of the UB-Zn(II) complexes responsible for the fluorescence enhancement in water could be gained. The possibilities of developing a sensitive analytical method based on the acquired understanding are also discussed.
Superparamagnetic hybrid polystyrene-core silica-shell beads have emerged as promising alternatives to traditional in flow cytometry-based competitive antibody assays [1]. These materials consist of a polystyrene core and a silica shell, in which magnetic nanoparticles are embedded, facilitating the handling and retention in tests. The outer silica surface allows for easy modification through silane chemistry, allowing the attachment of antibodies, or other molecules of interest. Ochratoxin A (OTA), a mycotoxin that can be found in grain products, coffee, cacao, or grapes, was chosen as the main target analyte to detect [2]. In this study, previously in house produced anti-OTA antibodies [3] were attached to the surface of the particles and the whole system was used as detection entity. In a first approach, the system was used for the development of a competitive cytometry assay using an OTA-fluorescein (OTA-F) adduct as competitor and marker. In this assay the fluorescence emitted by the OTA-F competitor on the surface of the particle was detected at a wavelength of 518 nm using a 533/30.H filter and was correlated to the forward scatter (FSC) to distinguish it from the excess of competitor still in solution. Under optimised conditions, the final assay showed a limit of detection of 0.03 nM. In a second approach, a simplified ready-to-inject fluidic system was built based on a laser (488 nm) and a photomultiplier detector to measure the signal of competitor still in solution. The competition step was carried out in a vial and the whole mixture was injected into the fluidic system. To avoid signal scattering, the particles were separated in-line using a magnet and only the OTA-F competitor still in solution was detected, reaching a limit of detection of 1.2 nM. With the aim to reduce user manipulation, the final assay is still under development for in-line incubation during the competitive step.
Drug facilitated sexual assaults (chemical submission) consists in the criminal administration of psychoactive substances without the permission of the victim. Among these compounds, scopolamine (SCP) (commonly well-known as burundanga} has emerged as the perfect psychotropic substance for aggressors because its ingestion induces automatism in the brain of the victim causing a state of submission. Physiologically, an appealing feature of SCP is their relevant role as a non-competitive muscarinic acetylcholine receptor antagonist with rapid and robust antidepressant effects in humans and other species. Specifically, SCP is able to block or dampen the biological response because of binding to an allosteric recombinant human muscarinic acetylcholine receptor M2/CM2 (Mi-AChR) site that is separate from the active recognition site of acetylcholine, thereby inhibiting the effects of the natural substrate and even of a potent agonist such as bethanechol. Here, a straightforward portable strip in combination with bioinspired hybrid nanomaterials for SCP drug in situ and at site detection was developed. The strips allow direct identification of SCP in diluted saliva down to 40 nM in less than 15 min using a smartphone for readout. For this purpose, we prepared a nanosensor based on mesoporous silica nanoparticles {MSNs) loaded with a fluorescent dye and functionalized with bethanechol. Attachment of the M2-AChR 'cap' to the silica scaffold enabled pore closure through non-covalent recognition. interactions with the anchored bethanechol moieties. In the presence of SCP pores were opened, due to the preferential interaction of the drug with receptor, thus releasing the encapsulated reporter and allowing it to be detected. Additionally, to a single-track strip, the extraordinary modularity of the hybrid biosensor materials in combination with the strip-pattering technologies enabled us to obtain a dual-channel strip for SCP and cannibal drug detection in a simple way, providing comparable analytical performance, while enabling further tailoring to the user's needs.
Direct detection of glyphosate in water with fluorescent molecularly imprinted polymer particles
(2022)
Analysis of environmental contaminants such as pesticides is increasing in importance due to frequent detection of residues in water reserves and food stuff, as well as lowering of maximum residue levels (MRLs). Molecularly imprinted polymers (MIPs) have been developed for preconcentration of these analytes prior to analysis by chromatographic techniques [1]. MIPs are prepared by polymerization of monomers in a matrix containing the analyte, followed by extraction of the analyte to obtain binding sites that are complementary to the analyte of interest. Recently, our group developed MIPs containing fluorescent reporter molecules that can be used for direct detection and quantification of 2,4-D in contaminated water. Core/shell MIP particles were employed, consisting of sub-micron silica nanoparticles coated with a MIP shell containing a fluorescent reporter whose signal was enhanced upon binding with 2,4-D in water. A limit of detection of 20 nM was attained [2]. We present here a comparable system, composed of fluorescent core-shell MIPs for the direct analysis of pesticides in environmental samples.
Perfluorocarboxylic acids (PFCAs) are a family of compounds that consist of a fully perfluorinated carbon backbone and a carboxylic acid moiety1. PFCAs have been classified as substances of very high concern by REACH regulations due to their persistence in the environment, non biodegradability and toxicological effects2. Thus, there is significant interest in detecting PFCAs in ground, waste, surface and drinking water. Fluorescence detection is a portable, easy-to-operate and cost-effective alternative, enabling the onsite detection of these analytes e.g., with miniaturized fluidic sensors.
Here, a guanidine benzoxadiazole (BD) dye covalently attached to a polymerizable methacrylate unit was developed for the integration of the dye into polymers and on surfaces. The response behavior of the dye toward PFCAs was assessed in monophasic (EtOAc) and biphasic (EtOAc-H2O) solvent systems, the biphasic system being advantageous for the extraction of the hydrophobic organic acids from the aqueous phase.
The BD dye was integrated into sensory silica core-polymer shell particles for the sensing of PFCAs directly in aqueous media. Submicron SiO2 particles were functionalized with 3 (trimethoxysilyl)propyl methacrylate followed by radical polymerization with the BD dye and ethylene glycol dimethacrylate. TEM images showed a homogeneous polymer shell with a thickness of 75±2 nm.
By incorporating the BD dye into core-shell particles, lower limits of detection (1.52 µM for perfluorooctanoic acid, PFOA) were achieved if compared to the use of the neat BD dye in a biphasic assay (17.3 µM for PFOA), and excellent discrimination against inorganic acids thanks to the hydrophobic polymer shell. The particle sensory platform has proven to be an alternative for the sensing of PFCAs directly in water.
Contamination of drinking water with pharmaceuticals is an emerging problem and a potential health threat. Immunochemical methods based on the binding of the analyte to specific antibodies enable fast & cost-effective on-site analyses. Magnetic bead-based immunoassays (MBBAs) allow for implementation into an immunosensor for online testing. Particles are prepared by either coupling the analyte molecule (diclofenac) or the respective antibody (amoxicillin) to the surface. For miniaturization, detection is performed electrochemically (chronoamperometry) on a microfluidic chip. The developed immunosensor will enable detection of pharmaceuticals directly in water supply pipes.
Core-shell (CS) particles have been increasingly used for a wide range of applications due to their unique properties by merging individual characteristics of the core and the shell materials. The functionality of the designed particles is strongly influenced by their surface roughness. Quantitative evaluation of the roughness of CS microparticles is, however, a challenging task for Scanning Electron Microscopy (SEM).
The SEM images contain two-dimensional (2D) information providing contour roughness data only from the projection of the particle in the horizontal plane. This study presents a practical procedure to achieve more information by tilting the sample holder, hence allowing images of different areas of a single particle to be recorded at different orientations under the same view angle. From the analysis of these images, quasi three-dimensional (3D) information is obtained.
Three types of home-made particles were investigated: i) bare polystyrene (PS) particles, ii) PS particles decorated with a first magnetic iron oxide (Fe3O4) nanoparticle shell forming CS microbeads, iii) PS/Fe3O4 particles closed with a second silica (SiO2) shell forming core-shell-shell (CSS) microbeads. A series images of a single particle were taken with stepwise tilted sample holder up to 10° by an SEM with high-resolution and surface sensitive SE-InLens® mode.
A reliable analysis tool has been developed by a script in Python to analyze SEM images automatically and to evaluate profile roughness quantitatively, for individual core-shell microparticles. Image analysis consists of segmentation of the images, identifying contour and the centre of the particle, and extracting the root mean squared roughness value (RMS-RQ) of the contour profile from the particle projection within a few seconds.
The variation in roughness from batch-to-batch was determined with the purpose to set the method as a routine quality check procedure. Flow cytometry measurements provided complementary data. Measurement uncertainties associated to various particle orientations were also estimated.
The simultaneous detection of different analytes has gained increasing importance in recent years, especially in the fields of medical diagnostics and environmental analysis. Multiplex assays allow for a range of biomarkers or pollutants to be rapidly and simultaneously measured. Particularly suitable formats for multiplexing are bead-based assays. The beads employed need to fulfil size and density requirements, important for instance for flow cytometry, and shall exhibit a high modularity to be facilely adapted to various kinds of analytes and detection systems. Core/shell particles are ideally suited in this sense because of their modularity in design and adaptability for various (bio)analytical assays. Here, polystyrene particles coated with different kinds of shells are presented, possessing features that are useful for a multitude of assay formats.
The particles in focus were coated with mesoporous and non-porous silica shells, with the possibility to introduce magnetic features to facilitate easier handling dependent on the assay format (e.g., in microfluidics). With high throughput analyses in mind, cytometric model assays were developed. Different factors such as pH or mediator salt used during shell preparation were evaluated with shell inspection by electron microscopy (SEM/TEM/EDX) being key to architectural control of the monodisperse particles. The optimized core/shell particles can be functionalized with capture biomolecules for toxins, viruses, or drugs to demonstrate particle performance. Showing how tailoring of the shell’s surface area controls sensitivity and dynamic range of the assay, an antibody-based assay for the detection of mycotoxins and a multiplex assay for the determination of DNA from different human papilloma virus (HPV) lines were developed.
Fluorescent molecularly imprinted polymer particles for detection of environmental contaminants
(2021)
Analysis of environmental contaminants such as pesticides is increasing in importance due to frequent detection of residues in water reserves and food stuff, as well as lowering of maximum residue levels (MRLs). Molecularly imprinted polymers (MIPs) have been developed for preconcentration of these analytes prior to analysis by chromatographic techniques. MIPs are prepared by polymerization of monomers in a matrix containing the analyte, followed by extraction of the analyte to obtain binding sites that are complementary to the analyte of interest. Recently, our group developed MIPs containing fluorescent reporter molecules that can be used for direct detection and quantification of 2,4-D in contaminated water. Core/shell MIP particles were employed, consisting of submicron silica nanoparticles coated with a MIP shell containing a fluorescent reporter whose signal was enhanced upon binding with 2,4-D in water. A limit of detection of 20 nM was attained. We present here a comparable system, composed of fluorescent core-shell MIPs for the direct analysis of pesticides in environmental samples.
Molecularly Imprinted Polymer Embedded BODIPY Probes for the Fluorescence Detection of Antibiotics
(2021)
Antibiotics are widely used to combat bacterial infections in humans and animals and their use has greatly improved modern healthcare. However, frequent and reckless use of antibiotics can cause antibiotic resistance in bacteria and pollute ecosystems. Therefore, the rapid and reliable detection of antibiotics is crucial. Fluorescence sensing is particularly attractive because of its high sensitivity and low limits of detection. Fluorescence assays can be carried out in a variety of platforms such as strips and particles among others. Recently, core-shell molecularly imprinted polymers (MIPs) have emerged as a promising sensor platform for (bio)chemical detection due to their low-cost, high stability, reusability, high affinity and selectivity.MIPs in combination with fluorescent molecular probes are gorgeous, since the covalently embedded probe allows for direct indication of a rebound template and provides a wealth of information about the binding state of a MIP through the multitude of fluorescence parameters accessible, facilitating MIP optimization.
In the present work, we have developed a novel series of fluorescent functional monomers, which consist of a fluorophore with a π-conjugated urea recognition site and one or two polymerizable units. The fluorescent monomers are covalently embedded into the MIP matrix to generate fluorescence changes upon template binding (Figure 1). Preliminary titrations of the dye monomer with the analytes show a blue shift of the absorption spectrum and a decrease in the fluorescence intensity which confirms the formation of hydrogen bonds between the urea and the carboxylate group of the antibiotic. Compared with the non-imprinted polymers, the MIP shells on core carrier particles have demonstrated an effective imprinting by showing a higher fluorescence response upon analyte binding.