Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (45)
- Forschungsdatensatz (22)
- Video (5)
- Sonstiges (4)
- Posterpräsentation (2)
- Zeitschriftenartikel (1)
Sprache
- Englisch (79)
Referierte Publikation
- nein (79) (entfernen)
Schlagworte
- X-ray scattering (42)
- MOUSE (28)
- SAXS (25)
- Small angle scattering (11)
- Methodology (9)
- Small-angle scattering (8)
- Data analysis (7)
- Software (7)
- Instrumentation (6)
- Lab automation (6)
Organisationseinheit der BAM
- 6 Materialchemie (76)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (76)
- 6.6 Physik und chemische Analytik der Polymere (6)
- 6.0 Abteilungsleitung und andere (4)
- VP Vizepräsident (4)
- VP.1 eScience (4)
- 5 Werkstofftechnik (2)
- 5.1 Mikrostruktur Design und Degradation (2)
- 6.3 Strukturanalytik (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.9 Chemische und optische Sensorik (1)
Eingeladener Vortrag
- nein (45)
Efforts are rising in opening up science by making data more transparent and more easily available, including the data reduction and evaluation procedures and code. A strong foundation for this is the F.A.I.R. principle, building on Findability, Accessibility, Interoperability, and Reuse of digital assets, complemented by the letter T for trustworthyness of the data. Here, we have used data, which was made available by the Institute Laue-Langevin and can be identified using a DOI, to follow the F.A.I.R.+T. principle in extracting, evaluating and publishing triple axis data, recorded at IN3.
Eleventh canSAS Meeting: International Cooperation and Collaboration in Small-Angle Scattering
(2019)
The eleventh canSAS workshop was held in Freising, Germany, July 8–10, 2019.
These international meetings, promoting collective action for nomadic small-angle scatterers, have been taking place since 1998 and act as forums to catalyze cooperation amongst the SAS community in order to provide better facilities and equipment, combined with reliable data interpretation and analysis. The meeting attracted over 60 participants from major neutron and X-ray laboratories, as well as manufacturers of SAXS equipment, and users from academia and industry. There was also a wide geographical spread with participants from Australia, Asia, and North America joining European colleagues.
2PP-TestArtifact
(2023)
This repository contains a test artifact (TA), also called test structure, designed for two-photon polymerization (also known as Direct Laser Writing (DLW) or Two/Multi-photon lithography (2PA/MPA)). Test artifacts can be used to compare structures, to check options used by the slicer, check the state of the 2PP machine itself or to get a construction guidelines for a certain combination of power, velocity and settings.
The associated paper can be found here: https://dx.doi.org/10.1088/1361-6501/acc47a
General ideas behind the test artifact:
1. optimized for 2PP-DLW
2. should be fast and easy to analyse with optical microscopy or 3. scanning electron microscopy without tilt.
3. short time to fabricate
4. include a reasonable amount of different features
5. bulk and small structures on the substrate
A brief introduction is given into our data collection and organization procedure, and why we have settled on the HDF5-based NeXus format for describing experimental data.
The links between NeXus and the SciCat data catalog is also provided, showing how the NeXus metadata is automatically added as searchable metadata in the catalog.
A tool for merging and/or rebinning single or multiple datasets to achieve a lower point density with best possible statistics. highly scriptable, CLI, no GUI
Version 0.1: works but could do with a cleanup. Weighting by uncertainty currently always on, but should be optional for use as an azimuthal or radial averager
Compared to the clear, real-space images you can get from electron microscopy, X-ray scattering patterns are rather featureless. These patterns, however, contain structural information from all of the material structure illuminated by the X-ray beam. With this technique, you can measure nanoparticle dispersions, catalysts, composites, MOF powders, battery materials, light metal alloys and gels to reveal information on the structural features found within these materials. We have even measured many such materials for several research groups from the University of Birmingham, revealing structure features in the sub-nm to the micrometer range.
Measuring an X-ray scattering pattern is relatively easy, but measuring a high-quality, useful pattern requires significant effort and good laboratory organization. Such laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration) [1]. With the MOUSE, we have combined: a) a comprehensive and highly automated laboratory workflow with b) a heavily modified X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, within a well-documented, FAIR-compliant data flow (akin to what is found at the more automated synchrotron beamlines). With two full-time researchers, our lab collects and interprets thousands of datasets, on hundreds of samples, for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data.
Introduction
A good laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration). In the MOUSE, we have combined: a) a comprehensive laboratory workflow with b) a heavily modified, highly automated X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, with a well-documented data flow (akin to what is found at the more automated beamlines). With two full-time researchers, the lab collects and interprets thousands of datasets, on hundreds of samples for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data.
While these numbers do not light a candle to those achieved by our hardworking compatriots at the synchrotron beamlines, the laboratory approach does allow us to continually modify and fine-tune the integral methodology. So for the last three years, we have incorporated e.g. FAIR principles, traceability, automated processing, data curation strategies, as well as a host of good scattering practices into the MOUSE system. We have concomitantly expanded our purview as specialists to include an increased responsibility for the entire scattering aspect of the resultant publications. This ensures full exploitation of the data quality, whilst avoiding common pitfalls.
Talk scope
This talk will present the MOUSE project as implemented to date, and will introduce foreseeable upgrades and changes. These upgrades include better pre-experiment sample scattering predictions to filter projects on the basis of their suitability, exploitation of the measurement database for detecting long-term changes and automated flagging of datasets, extending the measurement range through an Ultra-SAXS module, and enhancing MC fitting with sample scattering simulations for better matching of odd-shaped scatterers.
This is a set of drawings accompanying the submitted paper entitled "Extending Synchrotron SAXS instrument ranges through addition of a portable, inexpensive USAXS module with vertical rotation axes". The parts described herein will combine with commercial off-the-shelf components to build a high precision pair of rotation stages for accurate measurement of scattering angles with a sub-microradian precision.
The SAXS platform at BAM
(2021)