Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (57)
- Posterpräsentation (36)
- Zeitschriftenartikel (27)
- Sonstiges (7)
- Forschungsbericht (7)
- Beitrag zu einem Tagungsband (4)
- Handbuch (4)
- Forschungsdatensatz (2)
- Corrigendum (1)
Referierte Publikation
- nein (145) (entfernen)
Schlagworte
- Nanoparticles (72)
- Electron microscopy (32)
- Nanomaterial (23)
- Particle size distribution (21)
- TiO2 (14)
- EPMA (11)
- SEM/EDX (11)
- Traceability (11)
- Inter-laboratory comparison (10)
- Nanomaterial classification (10)
- VAMAS (10)
- Reference materials (8)
- SEM (8)
- EDS (7)
- Electron probe microanalysis (EPMA) (7)
- Electrospray deposition (6)
- TEM (6)
- Test material (6)
- Thin films (6)
- XPS (6)
- Fe-Ni (5)
- ISO (5)
- NanoDefine (5)
- Shape (5)
- Si-Ge (5)
- Size (5)
- Standardisation (5)
- Thin film analysis (5)
- Core-shell particles (4)
- Nanoparticle size distribution (4)
- Performance check (4)
- Roughness (4)
- Sample preparation (4)
- Scanning electron microscopy (4)
- Titanium oxide (4)
- VSSA (4)
- X-ray spectroscopy (4)
- Auger Electron Spectroscopy (3)
- Auger electron spectroscopy (3)
- BET (3)
- CEN/TC 352 Nanotechnologies (3)
- EDX (3)
- Fluorine (3)
- Functionalization (3)
- Image processing (3)
- Image segmentation (3)
- Iridium oxide (3)
- Microbeam analysis (3)
- Particle sizing techniques (3)
- Perovskite (3)
- Reference material (3)
- Regulation (3)
- Spectroscopic ellipsometry (3)
- ToF-SIMS (3)
- X-ray spectrometer (3)
- XRF (3)
- k-values (3)
- µ-XRF (3)
- 3D (2)
- Anatase (2)
- Automatisation (2)
- Certified reference materials (2)
- Classification (2)
- Convolutional neural networks (2)
- Data (2)
- Definition of nanomaterial (2)
- EBSD (2)
- EC definition (2)
- EC definition of a nanomaterial (2)
- EC definition of nanomaterial (2)
- EC4SafeNano (2)
- EDS-TM002 (2)
- EMPIR (2)
- EU definition of a nanomaterial (2)
- Electron probe microanalysis (2)
- FeNi (2)
- Hydrothermal synthesis (2)
- ISO/TC 229 (2)
- Laser ablation in liquid (2)
- Metrology (2)
- Microanalysis (2)
- Nanomaterials (2)
- Nanopartikel (2)
- Nanoplatelets (2)
- Non-spherical shape (2)
- Porous layers (2)
- Porous thin films (2)
- Pre-standardisation (2)
- SEM/EDS (2)
- SOP (2)
- SiGe (2)
- Solar cells (2)
- Standardization (2)
- Stratagem (2)
- TKD (2)
- Titania (2)
- Titanium dioxide (2)
- Transmission Kikuchi Diffraction (TKD) (2)
- Uncertainties (2)
- thin film analysis (2)
- ACEnano (1)
- AFM (1)
- Advanced materials (1)
- Agglomeration (1)
- Analytical services (1)
- Antigen testing (1)
- Artificial Intelligence (1)
- Atomic fraction (1)
- Au-nanocubes (1)
- Automated Image Analysis (1)
- Automated image analysis (1)
- Bimodal size distribution (1)
- Bipyramidal TiO2 nanoparticles (1)
- Bisphenol A degradation (1)
- Case studies (1)
- Catalogue of services (1)
- Categorisation scheme (1)
- Ceramic (1)
- Characterization (1)
- Characterization method (1)
- Characterization methods (1)
- Characterization techniques (1)
- Confirmatory methods (1)
- Copper alloy (1)
- Correlative Imaging (1)
- Correlative imaging (1)
- EDS Geometrical Detection Efficiency (1)
- EDS Solid Angle (1)
- EDS Spectrometer Test (1)
- EDS X-ray spectrometer (1)
- EDS detector (1)
- EDS net active sensor area (1)
- EDS performance check (1)
- EDS-TM001 (1)
- ESMA (1)
- EU (1)
- EU Definition of nanomaterial (1)
- EU definition (1)
- EU definition of nanomaterial (1)
- EU-Definition (1)
- Electrochemical immunosensor (1)
- Electron Microscopy (1)
- Electron Probe Microanalysis (1)
- Electron micrsocopy (1)
- Electrospray (1)
- Electrspray deposition (1)
- Elektronenmikroskopie (1)
- Elemental composition (1)
- Elementzusammensetzung (1)
- Ellipsometry (1)
- Energy dispersive X-ray spectroscopy (1)
- European Centre (1)
- FIB (1)
- Fenton oxidation (1)
- Few-layered titanium carbide nanosheets (1)
- Fluorescence correction (1)
- Framework (1)
- Gold (1)
- Graphene related 2D materials (1)
- Hard-energy X-ray photoelectron spectroscopy (1)
- High-resolution (1)
- Hyperspectral imaging (1)
- Iinter-laboratory comparison (1)
- Image Segmentation (1)
- Image analysis (1)
- Imaging (1)
- Interlaboratory Comparisons (1)
- Iridium-titanium mixed oxides (1)
- Label-free detection (1)
- Layer analysis (1)
- Layer analytics (1)
- Layer-by-layer deposition (1)
- Light elements (1)
- Machine learning (1)
- MamaLoCA (1)
- MamaLoCa (1)
- Measurement (1)
- Measurement method (1)
- Measurement techniques (1)
- Mesoporous films (1)
- Mesoporous thin films (1)
- Microarray printing (1)
- Microplastic (1)
- Microscopy (1)
- Modelling (1)
- Nano-Charakterisierung (1)
- Nano-Kompetenzzentrum (1)
- Nano-Projekte (1)
- Nano-characterisation (1)
- Nano-safety (1)
- NanoSIMS (1)
- Nanoanalytik (1)
- Nanocatalysts (1)
- Nanocubes (1)
- Nanodefine (1)
- Nanomaterial classfication (1)
- Nanoparticle concentration (1)
- Nanoparticle size (1)
- Nanoplastic (1)
- Nanosafety (1)
- Nanosafety services (1)
- Nanoscale (1)
- Nanotechnology (1)
- Net effective sensor area (1)
- Neural Networks (1)
- Neural networks (1)
- Non-spherical (1)
- Number-weighted median size (1)
- Oberflächenanalytik (1)
- P25 (1)
- PC characterisation (1)
- Particle Characterization (1)
- Particle characterisation (1)
- Particle morphology (1)
- Particle shape (1)
- Particle size (1)
- Particle size analysis (1)
- Particle size and shape distribution (1)
- Pervskite solar cells (1)
- Phase analysis (1)
- Photocatalysis (1)
- Porosity (1)
- Porous film (1)
- Porous layer (1)
- Powder (1)
- Powder X-ray diffraction (1)
- REM (1)
- REM/EDX (1)
- Raman (1)
- Referenzdaten (1)
- Regulatory identification of nanomaterials (1)
- Revision (1)
- SARS-CoV-2 nucleocapsid protein (1)
- SIMS (1)
- STEM-in-SEM (TSEM) (1)
- Screening methods (1)
- Secondary fluorescence (1)
- Secondary fluorescence correction (1)
- Shape control (1)
- Shape-controlled (1)
- Shape-enegineered nanoparticles (1)
- SiO2 (1)
- Silica (1)
- Size and shape distribution (1)
- Size distribution (1)
- Size measurement (1)
- Software (1)
- Solid angle (1)
- Spectrometer check (1)
- Spectrum imaging (1)
- Standard Operation Procedures (1)
- Standardarbeitsanweisung (1)
- Standardisierung (1)
- Standardized check (1)
- Substrates (1)
- Surface characterization (1)
- Surface functionalization (1)
- Surface modification (1)
- TEM grid (1)
- TEM grids (1)
- TOF-SIMS (1)
- TiO2 nanoplatelets (1)
- Tilting (1)
- Titania nanoparticles (1)
- Tools (1)
- Traceable size (1)
- Update 2017 (1)
- VAMAS inter-laboratory comparison (1)
- Volume specific surface area (VSSA) (1)
- WDX (1)
- Wastewater (1)
- X-ray detectors (1)
- X-ray photoelectron spectroscopy (1)
- X-ray spectrometry (1)
- X-ray yields (1)
- X-rays (1)
- XRD (1)
- nPSize (1)
- nanomaterial (1)
- shape control (1)
Organisationseinheit der BAM
- 6 Materialchemie (96)
- 6.1 Oberflächen- und Dünnschichtanalyse (96)
- 1 Analytische Chemie; Referenzmaterialien (11)
- 6.7 Materialsynthese und Design (7)
- 1.2 Biophotonik (5)
- 1.9 Chemische und optische Sensorik (4)
- 5 Werkstofftechnik (3)
- 6.3 Strukturanalytik (3)
- 1.8 Umweltanalytik (2)
- 5.1 Mikrostruktur Design und Degradation (2)
Eingeladener Vortrag
- nein (57)
The datasets from (Hard Energy) X-ray photoelectron spectroscopy, X-ray diffraction and Scanning Electron Microsopy are related to the publication
G. Chemello, X. Knigge, D. Ciornii, B.P. Reed, A.J. Pollard, C.A. Clifford, T. Howe, N. Vyas, V.-D. Hodoroaba, J. Radnik
"Influence of the morphology on the functionalization of graphene nanoplatelets analyzed by comparative photoelectron spectroscopy with soft and hard X-rays"
Advanced Materials Interfaces (2023), DOI: 10.1002/admi.202300116.
Functionalized Ti3C2Tx nanosheets based biosensor for point-of-care detection of SARS-CoV‑2 antigen
(2023)
MXenes are considered a promising class of two-dimensional materials with extraordinary physical and electrochemical properties. Distinguished features like high specific surface area and outstanding electrical conductivity make them suitable for electrochemical biosensing applications. Here, we report the development of a biosensor involving the functionalized MXene−titanium carbide nanosheets (Ti3C2Tx-NS) and monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SARS-CoV-2 mAb) to design a point-of-care device for detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 NP) antigen. Few-layered titanium carbide nanosheets (denoted as FL-Ti3C2Tx-NS) have been synthesized using a single-step etching and delamination method and characterized using optical and electron microscopy techniques revealing the suitability for immunosensing applications. Binding studies revealed the excellent affinity between the biosensor and the SARS-CoV-2 NP. Electrochemical detection of SARS-CoV-2 NP is performed using differential pulse voltammetry and read by a smartphone-based user interface. The proposed FL-Ti3C2Tx-NS based biosensor offers the detection of SARS-CoV-2 NP with a limit of detection of 0.91 nM in a wide detection range in spiked saliva samples. Additionally, there is no cross-reactivity in the presence of potential interferants like SARS-CoV-2 spike glycoprotein and bovine serum albumin. These findings demonstrate the potential of MXenes in developing a rapid and reliable tool for SARS-CoV-2 NP detection. While we report the biosensing of SARS-CoV-2 NP, our system also paves the way for the detection of other SARS-CoV-2 antigens like spike protein or other biomolecules based on antigen−antibody interactions.
In the present talk the basics of the Raman spectroscopy and particularly of Raman microscopy are explained. Advantages and disadvantages of the method are highlighted through selected case studies. In the second part of the lecture examples of correlative imaging with electron, X-ray, ion and optical microscopies from micro- to the nanoscale are highlighted.
For test laboratories operating under accreditation schemes like ISO/IEC 17025 (ISO/IEC 17025), as the international reference for testing and calibration laboratories wanting to demonstrate their capacity to deliver reliable results, a periodical control of the critical instrumental parameters of an Energy-Dispersive X-ray Spectrometer (EDS) is required.
This periodical check of an EDS is specified with exact procedures and materials in the ISO 15632:2021 ”Microbeam Analysis – Selected instrumental performance parameters for the specification and checking of energy-dispersive X-ray spectrometers for use in electron probe microanalysis” (ISO 15632). The EDS check can be simplified to the acquisition of only one 10 kV spectrum from a dedicated test material, EDS-TM002, which is made available by BAM since 2009 (https://webshop.bam.de/webshop_en/). The optional BAM software “EDX spectrometer check” is destined to automatically evaluate this spectrum and determine the performance of the EDS in terms of energy resolution and calibration, as well as possible alteration of low-energy efficiency due to detector contamination. Nearly 200 laboratories have the EDS-TM and associated software package in use.
Practical examples based on various types of artifacts occurred in the EDS spectra and a long-term (>10 years) meticulous observation of the own spectrometers will be discussed. Different types of EDS spectrometers are considered, e.g. Si(Li) and SDD, of various window types (AP, the recent one Si3N4 or even windowless), and with different front contact layers (Au and Ni) (Hodoroaba and Procop, 2014). Evaluation of other parameters or effects such as the deadtime at different count rates or pileup effects is also explained with examples.
CS particles show unique properties by merging individual characteristics of the core and the shell materials. An alteration particularly in their surface roughness affects the final performance of the particles in the targeted application. Quantitative evaluation of the roughness of CS microparticles is, however, a challenging task employing microscopic techniques being scarce and showing large differences in terms of methodology and results.
In our previous work, we have reported a systematic study with a reliable analysis tool, which evaluates profile roughness quantitatively, for individual core-shell microparticles using electron microscopy (EM) images of both types, Scanning Electron Microscopy (SEM) and transmission mode SEM (or TSEM). The SEM images contain two-dimensional (2D) information, therefore, provide profile roughness data only from the projection in the horizontal plane (in other words, from the “belly”) of a spherical particle. The present study offers a practical procedure to give access to more information by tilting the sample holder and hence allowing images of a single particle to be recorded at different orientations under the same view angle. From the analysis of these images, extended information on surface roughness of the particle can be extracted. Thus, instead of obtaining 2D information from a single SEM image, three-dimensional (3D) information is obtained from 2D projections recorded at different particle orientations.
Morpho-Chemical Characterisation of Me-TiO2 Nanoparticles for Enhanced Photocatalytical Activity
(2022)
The conversion of solar energy into electricity and solar fuels is of crucial importance for a green and sustainable future. Water splitting using semiconductor photo-catalysts is considered a sustainable method to produce clean hydrogen (H2) fuel. Nevertheless, H2 photo-production efficiency remains still low, although extensive research works to understand better the mechanisms of the Hydrogen Evolution Reaction (HER) and the Oxygen Evolution Reaction (OER) are being carried out. In this respect, TiO2 is a key photoactive material, usually employed with a co-catalyst deposited onto the surface to enhance charge carriers’ separation and catalyze surface charge transfer reactions. The deposition of a co-catalyst on the TiO2 nanoparticle surface represents one successful way to enhance the activity of the photocatalyst through a modification of its surface and redox properties. In this context, high-resolution scanning electron microscopy coupled with elemental analysis by energy-dispersive X-ray spectroscopy (EDS) is fundamental for studying and understanding the effect of the nanoparticle morphology on the functional properties of shape-controlled TiO2 crystals (bipyramides, platelets, and elongated particles). Different types of metal-semiconductor combinations, TiO2 shapes and dopant metals (Ag, Pt, etc) and metal concentrations will be discussed.
microscopy (AFM), or X-ray reflectometry. For the additional determination of thin film composition, techniques like X-ray photoelectron spectroscopy (XPS) or mass spectrometry-based techniques can be used. An alternative non-destructive technique is electron probe microanalysis (EPMA). This method assumes a sample of homogenous (bulk) chemical composition, so that it cannot be usually applied to thin film samples. However, in combination with the thin film software StrataGEM, the thickness as well as the composition of such films on a substrate can be determined.
This has been demonstrated for FeNi on Si and SiGe on Al2O3 film systems. For both systems five samples with different elemental composition and a reference were produced and characterised by Korean research institute KRISS using inductively coupled plasma mass spectrometry (ICP-MS), Rutherford backscattering (RBS), and transmission electron microscopy (TEM). These samples were used for an international round robin test.
In 2021, a new and open-source thin film evaluation programme called BadgerFilm has been released. It can also be used to determine thin film composition and thickness from intensity ratios of the unknown sample and standards (k-ratios).
In this contribution, we re-evaluated the data acquired for the FeNi and SiGe systems using the BadgerFilm software package and compared the resulting composition and thickness with the results of the established StrataGEM software and other reference methods. With the current evaluation, the BadgerFilm software shows good agreement with the composition and thickness calculated by StrataGEM and as the reference values provided by the KRISS.
Core-shell (CS) particles have been increasingly used for a wide range of applications due to their unique properties by merging individual characteristics of the core and the shell materials. The functionality of the designed particles is strongly influenced by their surface roughness. Quantitative evaluation of the roughness of CS microparticles is, however, a challenging task for Scanning Electron Microscopy (SEM).
The SEM images contain two-dimensional (2D) information providing contour roughness data only from the projection of the particle in the horizontal plane. This study presents a practical procedure to achieve more information by tilting the sample holder, hence allowing images of different areas of a single particle to be recorded at different orientations under the same view angle. From the analysis of these images, quasi three-dimensional (3D) information is obtained.
Three types of home-made particles were investigated: i) bare polystyrene (PS) particles, ii) PS particles decorated with a first magnetic iron oxide (Fe3O4) nanoparticle shell forming CS microbeads, iii) PS/Fe3O4 particles closed with a second silica (SiO2) shell forming core-shell-shell (CSS) microbeads. A series images of a single particle were taken with stepwise tilted sample holder up to 10° by an SEM with high-resolution and surface sensitive SE-InLens® mode.
A reliable analysis tool has been developed by a script in Python to analyze SEM images automatically and to evaluate profile roughness quantitatively, for individual core-shell microparticles. Image analysis consists of segmentation of the images, identifying contour and the centre of the particle, and extracting the root mean squared roughness value (RMS-RQ) of the contour profile from the particle projection within a few seconds.
The variation in roughness from batch-to-batch was determined with the purpose to set the method as a routine quality check procedure. Flow cytometry measurements provided complementary data. Measurement uncertainties associated to various particle orientations were also estimated.
A particle roughness analysis tool, based on electron microscopy images (SEM and TEM). The influence of various parameters on the calculated roughness was also investigated: the setting of the proper threshold, accelerating voltage, etc. The samples were gradually tilted to extend imaging information of more than only one projection. Furthermore, the measurement uncertainty of the profile roughness of particles associated to various orientations was estimated.