Analytische Chemie
Filtern
Erscheinungsjahr
- 2016 (637) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (214)
- Vortrag (193)
- Posterpräsentation (131)
- Beitrag zu einem Tagungsband (69)
- Sonstiges (10)
- Buchkapitel (6)
- Dissertation (5)
- Beitrag zu einem Sammelband (3)
- Forschungsbericht (3)
- Monografie (1)
Sprache
- Englisch (637) (entfernen)
Schlagworte
- XPS (25)
- Fluorescence (23)
- Concrete (19)
- Nanoparticles (19)
- Synchrotron (18)
- Simulation (16)
- NEXAFS (15)
- BAMline (13)
- LIBS (13)
- Mechanochemistry (13)
- XRF (13)
- Archaeometry (12)
- Imaging (11)
- Monitoring (11)
- Active thermography (10)
- Ultrasound (10)
- Computed tomography (9)
- Cultural heritage (9)
- EDX (9)
- Nanomaterial (9)
- Quantum yield (9)
- Rheology (9)
- SAXS (9)
- ICP-MS (8)
- LA-ICP-MS (8)
- Quantification (8)
- Cement (7)
- Electron microscopy (7)
- Laser ablation (7)
- Metrology (7)
- NIR (7)
- Nanoparticle (7)
- Raman spectroscopy (7)
- SERS (7)
- TiO2 (7)
- XRD (7)
- Calibration (6)
- DMD (6)
- DNA (6)
- Electron backscatter diffraction (6)
- Ferroelectret (6)
- Gas storage areas (6)
- In situ (6)
- Membrane-based gas sensing (6)
- Monte Carlo methods (6)
- Nanomaterials (6)
- Non-destructive testing (6)
- Online NMR spectroscopy (6)
- RFID sensors (6)
- Radiography (6)
- Round robin test (6)
- SIMS (6)
- Subsurface monitoring (6)
- XANES (6)
- AES (5)
- Antibody (5)
- DNA origami (5)
- Electrochemistry (5)
- Ellman (5)
- Flash excitation (5)
- IR (5)
- Integrating sphere spectroscopy (5)
- Magnetic field (5)
- Mass spectrometry (5)
- NDT (5)
- NMR (5)
- Optical spectroscopy (5)
- Pharmaceuticals (5)
- Plasma diagnostics (5)
- Raman (5)
- Reaction monitoring (5)
- SEM (5)
- Self-compacting concrete (5)
- Thin films (5)
- Traceability (5)
- AFM (4)
- Artificial digestion (4)
- CFRP (4)
- Cocrystal (4)
- Data fusion (4)
- Distributed linear sensor (4)
- Dye (4)
- ELISA (4)
- Embedded sensors (4)
- Energy harvesting (4)
- Flash thermography (4)
- Graphene (4)
- Hydrogen embrittlement (4)
- Immunoassay (4)
- Industrie 4.0 (4)
- Inverse analysis (4)
- Isotope dilution analysis (4)
- Laser induced plasma (4)
- Ligand analysis (4)
- MALDI-TOF MS (4)
- Measurements (4)
- Microstructure (4)
- Milling (4)
- Moisture (4)
- Nano (4)
- Paper (4)
- Particle size distribution (4)
- Plasma modeling (4)
- Polymer (4)
- Polymers (4)
- Process analytical technology (4)
- Quality assurance (4)
- RFA (4)
- Raman microscopy (4)
- Reference material (4)
- Rice husk ash (4)
- SAFT (4)
- Sensor (4)
- Silver nanoparticles (4)
- Soil (4)
- Standardization (4)
- Structural health monitoring (4)
- Surface analysis (4)
- TEM (4)
- Thermoacoustic (4)
- ToF-SIMS (4)
- Transmission characteristics (4)
- Ultrasonic transducer (4)
- Wireless sensors (4)
- Agricultural (3)
- Air-coupled (3)
- Aldrithiol (3)
- Ambient mass spectrometry (3)
- Analytical model (3)
- Antibodies (3)
- Assay (3)
- BESSY (3)
- Bio-imaging (3)
- Biocorrosion (3)
- Bioimaging (3)
- CCQM (3)
- CRM (3)
- Castings (3)
- Catalogues (3)
- Cell (3)
- Characterization (3)
- Chemometrics (3)
- Clustering (3)
- Dead Sea Scrolls (3)
- Dead Sea scrolls (3)
- Degradation (3)
- Depth profiling (3)
- Discontinuities (3)
- Dislocation (3)
- EBSD (3)
- EDS (3)
- Ellipsometry (3)
- Fiber bragg grating (3)
- Finite element method (3)
- Gas distribution mapping and gas source localization (3)
- Gas-phase NMR (3)
- Infrared spectroscopy (3)
- Laser (3)
- Least-squares adjustment (3)
- Life sciences (3)
- Magnetostrictive metal coating (3)
- Mass Spectrometry (3)
- Metal (3)
- Metal phosphonate (3)
- Microbiology (3)
- Microwave (3)
- Modeling (3)
- Modelling (3)
- OECD (3)
- Online (3)
- Online NMR (3)
- Online NMR Spectroscopy (3)
- Online monitoring (3)
- Optical assay (3)
- Oxidation (3)
- PEG (3)
- Pore radius (3)
- Process Analytical Technology (3)
- Prozessanalytik (3)
- Purity (3)
- RFID based sensors (3)
- RT (3)
- Relaxation time (3)
- Screed (3)
- Self-diagnostic fiber optical sensor (3)
- Semiconducor nanocrystals (3)
- Semitransparency (3)
- Single particle ICP-MS (3)
- Single-shot XAFS (3)
- Soil test field (3)
- Speciation (3)
- Spectral induced polarization (3)
- Strain (3)
- Sub-Saharan Africa (3)
- Superplasticizer (3)
- Surface protection (3)
- Synthesis (3)
- Thermal waves (3)
- Thermography (3)
- Thickness (3)
- Time resolution (3)
- Toxicity (3)
- UCST (3)
- Ultrasonic testing (3)
- Welding (3)
- Welds (3)
- X-rays (3)
- flow cytometry (3)
- fluorescence (3)
- Acoustic levitation (2)
- Active Thermography (2)
- Active pharmaceutical ingredient (API) (2)
- Adsorbates (2)
- Aerosol (2)
- Airborne (2)
- Analytical centrifuge (2)
- Artificial defect (2)
- Back-scatter techniques (2)
- Biocompatibility (2)
- Biofilms (2)
- Broadband dielectric spectroscopy (2)
- Carbograph 5TD (2)
- Carbopack X (2)
- Casting (2)
- Cement hydration (2)
- Centrifuge technology (2)
- Classification (2)
- Cocain (2)
- Coda wave interferometry (2)
- Composite (2)
- Computertomographie (2)
- Concrete evaluation (2)
- Core@Shell Nanoparticles (2)
- Corresponding relative humidity (2)
- Corrosion (2)
- Creep (2)
- Crystallization (2)
- Cytotoxicity (2)
- DRIFTS (2)
- Degree of purity (2)
- Digital image analysis (2)
- Distributed sensor (2)
- Dual-energy imaging (2)
- DuraBASt (2)
- Dyes (2)
- EC-MS (2)
- EDM (2)
- EPMA (2)
- ESI-TOF-MS (2)
- EXAFS (2)
- Electric discharge machining (2)
- Electron transport (2)
- Embedded (2)
- Embedded sensor (2)
- Energy reserves (2)
- Environmental analysis (2)
- Experiments (2)
- FRET (2)
- Ferrocene (2)
- Fiber Bragg grating (2)
- Fiber Bragg gratings (2)
- Field conditions (2)
- Field-flow fractionation (2)
- Finite Element Method (2)
- Flow cytometry (2)
- Fluorescence spectroscopy (2)
- Fluorescence standard (2)
- Fluorescent and thermoresponsive nanoparticles (2)
- GaP (2)
- Gas analysis (2)
- Geophysics (2)
- Gold nanoparticles (2)
- Grain geometry (2)
- High resolution ultrasonic testing (2)
- High-resolution (2)
- Honeycombing (2)
- Humidity sensors (2)
- Hydrogen assisted cracking (2)
- IR-MALDI (2)
- Immersion tank testing (2)
- Impurities (2)
- In situ analysis (2)
- Inspection (2)
- Inter-laboratory comparison (2)
- Invertebrates (2)
- Ionic liquids (2)
- Isotope dilution (2)
- Jet grouting (2)
- LC-MS/MS (2)
- Laminography (2)
- Leak detection (2)
- Levee (2)
- Lifetime (2)
- Lifetime encoding (2)
- Ligand (2)
- Ligand exchange (2)
- Linear sensor (2)
- Low field NMR spectroscopy (2)
- Machine learning (2)
- Magnetostriction (2)
- Manuscripts (2)
- Mapping (2)
- Membrane-based linear gas sensor (2)
- Mercury intrusion capillary pressure (2)
- Modular production units (2)
- Moisture measurements (2)
- Molecularly imprinted polymers (2)
- Monitoring of chemical reactions (2)
- Monte Carlo method (2)
- Multiplexing (2)
- Nanomaterial classification (2)
- Nanoparticles separation asymetrical flow field flow fractionation (2)
- Nanopartikel (2)
- Nd-sensitizer (2)
- Neutron imaging (2)
- Neutron radiography (2)
- Neutron tomography (2)
- Nondestructive testing (2)
- Oxidative stress (2)
- Oxidative stress biomarkers (2)
- PEG-Maleimide (2)
- Partial least squares regression (2)
- Particle size analysis (2)
- Peptides (2)
- Pesticides (2)
- Phased array (2)
- Photon-electron transport (2)
- Piezoelectric (2)
- Pigments (2)
- Plasma (2)
- Plasma physics (2)
- Platinum (2)
- PnCCD (2)
- Polycarboxylate ether (2)
- Polycrystalline materials (2)
- Polymer particles (2)
- Pore geometry (2)
- Probes (2)
- Process control (2)
- Proficiency testing (2)
- Protein quantification (2)
- Prozess-Sensoren (2)
- Purity assessment (2)
- Quality control (2)
- Quality system (2)
- Quantitative NMR spectroscopy (2)
- Quantitative NMR-Spektroskopie (2)
- Quantum dots (2)
- Radiology (2)
- Ray tracing (2)
- Reaction Monitoring (2)
- Reference defect (2)
- Reference materials (2)
- Reproducibility (2)
- Rock structure (2)
- SEC (2)
- SEP 1927 (2)
- SIP (2)
- SLM (2)
- STM (2)
- Semiconductor quantum dot (2)
- Shape (2)
- Silica support (2)
- Smart Sensors (2)
- Standard (2)
- Standardisation (2)
- Standards (2)
- Strength (2)
- Structure health monitoring (2)
- Substrate (2)
- Sulfamethoxazole (2)
- Superalloy (2)
- Superplasticizers (2)
- Surface chemical analysis (2)
- Surface-enhanced Raman scattering (2)
- Synchrotron radiation (2)
- Tattoo (2)
- Temperature (2)
- Thermal Wave (2)
- Thermal desorption (2)
- Thin film (2)
- Thiols (2)
- Time-of-flight mass spectrometry (2)
- Two photon microscopy (2)
- UCNP (2)
- Upconversion (2)
- Upconversion nanocrystals (2)
- VVOC (2)
- Water (2)
- Workability (2)
- X-Ray diffraction (2)
- X-ray absorption spectroscopy (2)
- X-ray microdiffraction (2)
- X-ray refraction (2)
- X-ray spectroscopy (2)
- ambient mass spectrometry (2)
- chemical sensing (2)
- computed tomography (2)
- emission spectroscopy (2)
- gold nanoparticles (2)
- immunoassay (2)
- life sciences (2)
- lifetime encoding (2)
- mass spectrometry (2)
- metrology (2)
- nanoprobes (2)
- polymer particles (2)
- purity (2)
- quality control (2)
- silver nanoparticles (2)
- standardization (2)
- traceability (2)
- upconversion (2)
- “Click” chemistry (2)
- (HAX)PES (1)
- 19F-NMR (1)
- 1H-NMR (1)
- 2-D electrophoresis (1)
- 29Si-27Al TRAPDOR MAS (1)
- 29Si{27Al} TRAPDOR MAS NMR (1)
- 2D gel electrophoresis (1)
- 2PM Fly Scan (1)
- 3D (1)
- 3D High-temperature shape screening (1)
- 3D reconstruction (1)
- Ab initio calculations (1)
- Accelerated stress testing (1)
- Acoustic actuator (1)
- Activatable probe (1)
- Activation energy (1)
- Active thermal cycling (1)
- Actuators (1)
- Additive Manufacture (1)
- Adhesive tapes (1)
- Adhesives and adhesive tapes (1)
- Admixtures (1)
- Adsorption (1)
- Adulteration detection (1)
- Advanced oxidation processes (1)
- Ag nanoparticles (1)
- Aggregation (1)
- Aggregation-induced emission (1)
- Air purification (1)
- Airport security (1)
- Algorithm (1)
- Aluminium (1)
- Aluminosilicates (1)
- Ambient (1)
- Amides (1)
- Amine derivatives (1)
- Amines (1)
- Amino acid analysis (1)
- Ammonia (1)
- Ammonia in ambient air (1)
- Amorphous materials (1)
- Analysis of lanthanoides (1)
- Analytical approach (1)
- Analytical centrifugation (1)
- Analytical method (1)
- Analytical methods (1)
- Analytics (1)
- Annular space (1)
- Anti-fouling (1)
- Anti-oxidative efficiency (1)
- Antibody ID (1)
- Antibody immobilization (1)
- Antibody labeling (1)
- Antikörper (1)
- Application (1)
- Applications (1)
- Aqueous dispersion (1)
- Aqueous solution (1)
- Ar gas cluster gun (1)
- Archaeology (1)
- Archäologie (1)
- Art (1)
- Artificial photosynthesis (1)
- Arzneistoffe (1)
- Atherosclerotic plaques (1)
- Atmosphärendruck (1)
- Atmosphärendruck-Massenspektrometrie (1)
- Atmosphärendruckmassenspektrometrie (1)
- Atom transfer radical polymerization (1)
- Atomic weight (1)
- Au(111) (1)
- Auger electron spectroscopy (1)
- Automation (1)
- Automotive industry (1)
- Autonomous micro UAV (1)
- Azidation (1)
- Azimuthal temperature field (1)
- Azimuthal well logging (1)
- BAM L200 (1)
- BAM certification body (1)
- BCA assay (1)
- BDS broadband dielectric spectroscopy (1)
- BET specific surface area (1)
- BODIPY (1)
- BRET/CRET (1)
- Back scatter (1)
- Backscatter application (1)
- Bacteria (1)
- Bacterial Extracellular Electron Transfer Mechanisms (1)
- Bacterial biofilms (1)
- Barium titanate nanopowder (1)
- Benzamide (1)
- Benzene sensor (1)
- Berlin Main Station (1)
- Berlin tap water (1)
- Bibliothek ternärer Pd-Legierungen (1)
- Bio imaging (1)
- Bio-Imaging (1)
- Bio-molecular surfaces (1)
- Bioerosion (1)
- Biofilm (1)
- Biolabels (1)
- Biological application (1)
- Biological structure (1)
- Biologically inspired robots (1)
- Biomarker (1)
- Biomarkers (1)
- Bioorganic film (1)
- Biosensor (1)
- Biotin–FITC titration (1)
- Biotoxins - Biotoxine (1)
- Biotransformation (1)
- Bisphenol A (1)
- Bivalves (1)
- Bonding (1)
- Bonding strength (1)
- Borate glasses (1)
- Braunschweig meteorite (1)
- Breath (1)
- Breath alcohol analyser (1)
- Bremsstrahlung (1)
- Brinell (1)
- Broadband Dielectric Spectroscopy (1)
- Broadband Dielectric Spectrscopy (1)
- Brominated carbon nanotubes (1)
- Bruchmechanik (1)
- Building materials (1)
- Bulk chemistry (1)
- CCQM-K101 (1)
- CEFIT (1)
- CFD (1)
- CFD simulation (1)
- CFK (1)
- CIGS (1)
- CIGS thin films (1)
- CMC (1)
- CO adsoprtion (1)
- CO adsorption (1)
- CONSENS (1)
- COOMET.QM-S5 (1)
- CRM producer (1)
- CT (1)
- Caco-2 cells (1)
- Calcium phosphate cement (1)
- Calcium-carbonate (1)
- Calculation (1)
- Calibration-free analysis (1)
- Calibration-free laser-induced breakdown spectroscopy (1)
- Cancer (1)
- Carbamazepine (1)
- Carbon dots (1)
- Carbon nanomembranes (1)
- Carbon nanotubes (1)
- Carbonate substrate (1)
- Carotenoids (1)
- Catalyst (1)
- Catalytic activity (1)
- Cations (1)
- Cell proliferation (1)
- Cell viability (1)
- Cellular internalization (1)
- Cellular polypropylene (1)
- Cellular uptake (1)
- Cement clinker (1)
- Cement paste (1)
- Central Asia (1)
- Ceramic (1)
- Ceramic dispersion (1)
- Ceramic suspension (1)
- Ceramics (1)
- Certification (1)
- Certified reference material (1)
- Certified reference materials (1)
- Channeling (1)
- Characterisation techniques (1)
- Characterization and analytical techniques (1)
- Charakterisierung (1)
- Charge separation (1)
- Charge transfer (1)
- Chemical analysis (1)
- Chemical derivatization (1)
- Chemical imaging (1)
- Chemical imaging analysis (1)
- Chemical modification (1)
- Chemical sensors (1)
- Chemical warfare agents (1)
- Chemische Modifizierung (1)
- Chemometric tool (1)
- Chiral (1)
- Chloride (1)
- Chlorophyll (1)
- Cisplatin (1)
- Clams (1)
- Click chemistry (1)
- Clinoptilolite (1)
- Coal (1)
- Coating (1)
- Coatings (1)
- Cobalt (1)
- Coffee (1)
- Color coding (1)
- Compact NMR (1)
- Comparison of techniques (1)
- Composition (1)
- Computer modeling (1)
- Confinement (1)
- Conformational analysis (1)
- Consolidated materials (1)
- Constitutive relations (1)
- Consume care products (1)
- Control charts (1)
- Copolyester (1)
- Copolymer (1)
- Copolymer sequence (1)
- Copper(II) - phenanthroline - complexe filmss (1)
- Core (1)
- Core / shell / shell / nanoparticles (1)
- Core shell nano particle (1)
- Core-Shell (1)
- Core/shell particles (1)
- Coulometric sensor (1)
- Coverslip seal (1)
- Crack detection (1)
- Creep-resistant steel (1)
- Crisis (1)
- Crystal-growth (1)
- Crystallinity (1)
- Cumin discrimination (1)
- Cusum (1)
- Cyanine (1)
- Cyclic voltammetry (1)
- Cyclization (1)
- Cyclohexane (1)
- Cytometry (1)
- D2XRF (1)
- DFT spectrum simulations (1)
- DLS (1)
- DMD coupled laser (1)
- DNA damage (1)
- DNA origami nanostructures (1)
- DNA radiation damage (1)
- DNA sensor (1)
- DNA-Schädigung (1)
- DNA/RNA (1)
- DPSS laser (1)
- Damage (1)
- Dangerous goods container (1)
- Data processing (1)
- Databases (1)
- Debye-Waller factor (1)
- Deconvolution (1)
- Dedolomite (1)
- Defect detection (1)
- Defects (1)
- Degree of equivalence (1)
- Density (1)
- Density estimation (1)
- Density of states (1)
- Depth-Profiling (1)
- Depth-profiling (1)
- Design of Experiments (1)
- Diabetes mellitus and Alzheimer's disease (1)
- Diagnosis of concrete components (1)
- Diagnostics (1)
- Diameter (1)
- Dielectric barrier discharge (1)
- Dielectric materials (1)
- Differential displacements (1)
- Diffraction contrast (1)
- Diffusion (1)
- Digestion (1)
- Digital detector arrays (1)
- Digital radiography (1)
- Dimensionelle Metrologie (1)
- Diopatra neapolitana (1)
- Direction-oriented image (1)
- Directional interface variance analysis (DIVA) (1)
- Discrimination of multiple gas sources (1)
- Dissociative electron attachment (1)
- Divergent XAFS (1)
- Drop test (1)
- Duplex stainless steel (1)
- Dye bioconjugates (1)
- Dynamic glass transition (1)
- Dynamical theory (1)
- EC definition of nanomaterial (1)
- EDS Geometrical Detection Efficiency (1)
- EDS Solid Angle (1)
- EDS detector (1)
- EDS net active sensor area (1)
- EISA (1)
- EMRP (1)
- EN 196 (1)
- EPTIS (1)
- ESEM (1)
- EU (1)
- Ectoine (1)
- Education of NDT personnel (1)
- Effective area (1)
- Eigenspannungen (1)
- Electrical methods (1)
- Electrochromic device (1)
- Electrochromism (1)
- Electrohydraulic effect (1)
- Electron tomography (1)
- Electronic Nose (1)
- Electronic nose (1)
- Electrons (1)
- Electrspray deposition (1)
- Elektronen (1)
- Element microscopy (1)
- Elevated temperatures (1)
- Eluting stent (1)
- Emerging Pollutants (1)
- Emissionsspektroskopie (1)
- Energetic material (1)
- Energy dissipation (1)
- Energy sensor (1)
- Energy transfer (1)
- Energy-dispersive X-ray spectrometer (EDS) (1)
- Environmental quality standard (EQS) (1)
- Environmentally relevant concentrations (1)
- Enzyme sensor (1)
- Epoxy (1)
- Euramet EMRP (1)
- Europium complex (1)
- Excitation (1)
- Exfoliation (1)
- Explosives (1)
- Expression of uncertainty (1)
- FAME (1)
- FE-EPMA (1)
- FEFF (1)
- FFT periodogram (1)
- FIB (1)
- FRET system (1)
- FT-IR spectroscopy (1)
- Fall reconstruction (1)
- Faujasite-type zeolites (1)
- Fault tree analysis (1)
- Fenton (1)
- Fiber characterization (1)
- Fiber optics sensors (1)
- Fiber-optic sensor (1)
- Fibre optical sensing (1)
- Field Enhancement (1)
- Field flow fractionation (1)
- Figures of merit (1)
- Film thickness determination (1)
- Finite element methods (1)
- Flash lamp (1)
- Flat bottom holes (1)
- Flow Cytometry (1)
- Fludarabine (1)
- Flugzeitmassenspektrometer (1)
- Flugzeitmassenspektrometrie (1)
- Fluorapatite-gelatin nanocomposites (1)
- Fluorescence sensor (1)
- Fluorescence spectroscopy and imaging (1)
- Fluorescent amplification strategies (1)
- Fluorescent nanoreporters (1)
- Fluoresence (1)
- Fluorophore (1)
- Fluorophore tracer (1)
- Focusing (1)
- Foldamers (1)
- Forgery (1)
- Foundations (1)
- Fresh Concrete (1)
- Fresh concrete (1)
- Friction (1)
- Friedel's rule (1)
- Full matrix capture (1)
- Fullerene (1)
- Fullerene C60 (1)
- Functional group analysis (1)
- Functionalization (1)
- Functionalization of fullerenes (1)
- Fungal Volatiles (1)
- Fusarium Mycotoxins (1)
- G quadruplex (1)
- GD-MS (1)
- GDMS (1)
- GIXRF (1)
- GMR (1)
- GTA-Welding (1)
- GaAs (1)
- GaN (1)
- Gadolinium-based contrast agents (1)
- Gadolinium-uptake (1)
- Gas Sensors, Safety (1)
- Gas chromatography (1)
- Gas sensor (1)
- Gas sensors (1)
- Gas source localization (1)
- Gated delivery system (1)
- Gated release systems (1)
- Geographical origins (1)
- Geometrical collection efficiency (1)
- Geopolymer (1)
- Glow discharge (1)
- Glucose and nanoplaque formation (1)
- Glycan microarray (1)
- Gold (1)
- Gold Synchrotron XRF (1)
- Gold surface (1)
- Gold-Nanopartikel (1)
- Grain boundaries (1)
- Granules (1)
- Graphene oxide (1)
- Groundwater observation well (1)
- Grouping (1)
- Guest complexe (1)
- Guided waves (1)
- Gypsum (1)
- HDL protection (1)
- HILIC (1)
- HPLC (1)
- HPLC-MS/MS (1)
- HR-SEM (1)
- HRMS-Identifizierung (1)
- HS-PG flow sensor and lipoprotein receptor (1)
- Hair follicles (1)
- Hardening (1)
- Hardness testing (1)
- Harmful Algal Bloom (HAB) (1)
- Headspace Analysis (1)
- Headspace GC (1)
- Heat shock response (1)
- Heat treatment condition (1)
- Heterogeneity (1)
- Heterogeneous photocatalysis (1)
- High impact testing (1)
- High performance liquid chromatography (1)
- High pressure (1)
- High repetition rate (1)
- High resolution continuum source absorption spectrometry (1)
- High strength concrete (1)
- High strength steels (1)
- High throughput biosensing (1)
- High-pressure NMR (1)
- High-repetition rate laser (1)
- High-resolution ICP-MS (1)
- High-speed biosensor (1)
- Histology (1)
- Homogeneity (1)
- Homogenisation (1)
- Hot crack (1)
- Hot spot (1)
- Humic acid (1)
- Humidity induced annealing (1)
- Hybrid materials (1)
- Hybrid nanoparticles (1)
- Hybrid sensor materials (1)
- Hydrates (1)
- Hydration (1)
- Hydraulic levelling system (1)
- Hydrazinchemie (1)
- Hydroformylation (1)
- Hydrogen (1)
- Hydrogen Sensors (1)
- Hydrogen Technologies (1)
- Hydrogen bonds (1)
- Hydrogen diffusion (1)
- Hydrogen sensor (1)
- Hydrogen trapping (1)
- Hydrolysis (1)
- Hydrophilic interaction chromatography (HILIC) (1)
- IDLapoE3/E3 and IDLapoE4/E4 isoforms (1)
- IDMS (1)
- IHM (1)
- ILC (1)
- IR spectroscopy (1)
- ISO (1)
- ISO standards (1)
- Image Analysis (1)
- Image morphology (1)
- Imaging ToF SIMS (1)
- Imaging ellipsometry (IE) (1)
- Imaging plates (1)
- Imaging technique (1)
- Immuno imaging (1)
- Immuno-assays (1)
- Immunoarrays (1)
- Immunosensor (1)
- In situ measurement (1)
- In situ reactions (1)
- In vitro (1)
- In-situ loading (1)
- Indirect hard modeling (1)
- Indometacin (1)
- Inductively coupled plasmamass spectrometry (ICP-MS) (1)
- Industrial gases (1)
- Infrared Thermography (1)
- Infrared imaging (1)
- Infrared thermography (1)
- Inhibition assay (1)
- Inhibition rate constant (1)
- Ink (1)
- Integrity (1)
- Interface analysis (1)
- Interfaces (1)
- Interlaboratory Study (1)
- Interlaboratory comparison (1)
- Intermediate (1)
- Internal standard (1)
- Internal standardization (1)
- Inverse Analysis (1)
- Iodonium (1)
- Ion Mobility (1)
- Ion mobility (1)
- Ion mobility spectrometry (1)
- Ionenquelle (1)
- Ionic liquid (1)
- Ionisation (1)
- Ionisierung (1)
- Ionization (1)
- Ir (1)
- Iron and steel (1)
- Iron oxide (1)
- Isoelectric point (1)
- Isomerisierung (1)
- Isotope dilution mass spectrometry (1)
- Isotope mixture (1)
- Isotope ratio (1)
- Isotopenstandard (1)
- Iterative reconstruction (1)
- Katalysator (1)
- Key comparison (1)
- Kinematic theory (1)
- Kompositen (1)
- KonSens (1)
- KorroPad (1)
- Kulturelles Erbe (1)
- Kunst (1)
- L chondrite (1)
- LA-ICP-MS based immunoassays (1)
- LA-ICP-MS microscopy (1)
- LEIS (1)
- Lab-on-valve (1)
- Lactide (1)
- Langmuir isotherm (1)
- Lapis Lazuli (1)
- Large animal model (1)
- Laser Ablation (1)
- Laser Induced Breakdown Spectroscopy (LIBS) (1)
- Laser Induced Fluorescence (LIF) (1)
- Laser ablation (LA)-ICP-MS (1)
- Laser ablation ICP-MS (1)
- Laser induced breakdown spectroscopy (LIBS) (1)
- Laser induziertes Plasma (1)
- Laser profilometry (1)
- Laser-based displacement measuring system (1)
- Laser-induced plasma (1)
- Laser-spark (1)
- Lateral resolution (1)
- Lattice parameter determination (1)
- Layer-by-layer deposition (1)
- Lead isotopic composition (1)
- Least-Squares Adjustment (1)
- Legierungen (1)
- Leguminosen (1)
- Library of ternary Pd-alloys (1)
- Ligands (1)
- Light damage (1)
- Light microscopy (1)
- Line scan (1)
- Lipid Nanodiscs (1)
- Liposomes (1)
- Liquefied gases (1)
- Liquefied petroleum gas (1)
- Liquid cell (1)
- Liquid chromatography (1)
- Lithiation (1)
- Ln-MeCAT-Click labeling (1)
- Load (1)
- Load partition (1)
- Lock-in Thermografie (1)
- Lock-in thermography (1)
- Long-life sensor casing (1)
- Long-term exposure (1)
- Long-term exposures (1)
- Low energy (1)
- Low-cost housing (1)
- Luminescent probes (1)
- MALDI (1)
- MALDI-TOF MS/MS (1)
- MALDI-TOF Mass Spectrometry (1)
- MALDI-TOF-MS (1)
- MDFEM (1)
- MOF (1)
- MOFs (1)
- Macrocycles (1)
- Magnesium (1)
- Magnetic nanocomposites (1)
- Magnetische Nanopartikel (1)
- Magnetite nanoparticles (1)
- Magnetron sputtering (1)
- Manual testing (1)
- Manuskripte (1)
- Marker (1)
- Mass cytometry (1)
- Mass deposition (1)
- Material analysis (1)
- Material equations (1)
- Materialanalyse (1)
- Matrix influence (1)
- Measurement and testing (1)
- Measurement techniques (1)
- Medium-resolution NMR (1)
- Membrane (1)
- Membrane polarization (1)
- Mercury (1)
- Mercury intrusion (1)
- Mesoporous Silica (1)
- Metabolic transformation (1)
- Metabolites (1)
- Metal Matrix Composites (1)
- Metal elements (1)
- Metal matrix composites (1)
- Metal nanoparticles (1)
- Metal phosphonates (1)
- Metal staining procedures (1)
- Metallo-supramolecular polyelectrolytes (1)
- Metalloproteins (1)
- Metals (1)
- Method development (1)
- Method validation (1)
- Microbeads (1)
- Microbiological induced corrosion (1)
- Microbiologically induced corrosion (1)
- Microfluidic sensor (1)
- Microfluidics (1)
- Microporous (1)
- Microscopy (1)
- Microspectroscopic imaging (1)
- Microstrain (1)
- Microstrain distribution (1)
- Microstructured fibers (1)
- Mineral additions (1)
- Miniature (1)
- Miniaturization (1)
- Miniaturized AF4 channel (1)
- Minimal-invasive (1)
- Missing wedge (1)
- Mobile robot olfaction (1)
- Modeling and simulation (1)
- Moisture measuring (1)
- Molecular alignment relaxation (1)
- Molecular beacon (1)
- Molecular devices (1)
- Molecular diagnostics (1)
- Molecular machines (1)
- Molecular motor (1)
- Molecular-dynamics (1)
- Monitoring of CO 2 (1)
- Monitoring of dangerous goods (1)
- Monoklonal (1)
- Monolayer (1)
- Monte Carlo simulation (1)
- Mounting medium (1)
- Multi-parameter POD (1)
- Multi-sensor data fusion (1)
- Multi-walled carbon nanotubes (1)
- Multichannel measuring (1)
- Multigas sensor (1)
- Multiple-sample bonding (1)
- Multiple-sample testing (1)
- Multiplexing immunoassay (1)
- Multivariate analysis (1)
- Multivariate statistics (1)
- Mycotoxin (1)
- Mycotoxins (1)
- NDT reliability (1)
- NDT-CE (1)
- NIR spectroscopy (1)
- Nano materials (1)
- Nano particles (1)
- Nano scale (1)
- Nanoclay hybrids (1)
- Nanocomposite (1)
- Nanocomposites (1)
- Nanomaterialien (1)
- Nanometrology (1)
- Nanoparticle coating (1)
- Nanoporous Al2O3 (1)
- Nanorings (1)
- Nanoroughness (1)
- Nanosensor (1)
- Nanostructured Electrodes (1)
- Natural zeolite Clinoptilolite (1)
- Near-infrared laser (1)
- Nephrotoxicity (1)
- Nerve gases (1)
- Net effective sensor area (1)
- Neurons (1)
- Neutron diffraction (1)
- Neutron scattering (1)
- Neutronenbeugung (1)
- Ni-base superalloy (1)
- Nickel RSF (1)
- Nicotinamide (1)
- Nile Red (1)
- Noble gas isotopes (1)
- Non-centrosymmetry (1)
- Non-destructive methods (1)
- Non-ferrous metals (1)
- Nondestructive flaw detection (1)
- Nonlinear rheology (1)
- Normung (1)
- Nuclear (1)
- Nuclear magnetic resonance (1)
- Nucleation (1)
- Nucleic acids (1)
- Number-weighted median size (1)
- Numeric modelling (1)
- Numerical modeling (1)
- Ocean acidification (1)
- Oil diesel fraction (1)
- On-site LIBS (1)
- One-part formulation (1)
- Online Monitoring (1)
- Online-NMR spectroscopy (1)
- Online-Raman spectroscopy (1)
- Optical characterization (1)
- Optical fiber sensor climatic stability (1)
- Optical layer model (1)
- Optical layer reconstruction (1)
- Optical microscopy (OM) (1)
- Optical properties (1)
- Optical sensor (1)
- Optical transfer standard (1)
- Optically pumped plasma lasers (1)
- Organic layers (1)
- Organic matter (1)
- Organic osmolytes (1)
- Organic pollutants (1)
- Orientation description (1)
- Osteoporosis (1)
- Oxide-films (1)
- Oxygen-containing functionalities (1)
- PAMAM dendrimers (1)
- PFOA (1)
- PFOS (1)
- PIM-1 (1)
- PIXE (1)
- PLS-R (1)
- PLSR (1)
- PLasma physics (1)
- PT (1)
- Packing density (1)
- Paper spray ionization (1)
- Papier (1)
- Papierbasiert (1)
- Paracetamol (1)
- Parallel computing (1)
- Parallel seismic (1)
- Passive layer (1)
- Pattern matching (1)
- Peel (1)
- Perfluordecalin (1)
- Peri-implantitis (1)
- Permeability (1)
- Permeation (1)
- Pesticide parathion-methyl (1)
- Petrology and mineralogy (1)
- Pharmaceutical drugs (1)
- Pharmazeutika (1)
- Phase distribution (1)
- Phase identification (1)
- Phase measurement (1)
- Phase transfer (1)
- Phenylalanine (1)
- Phomopsin-Derivate (1)
- Phosphates (1)
- Photocatalysis (1)
- Photochemistry (1)
- Photoelectron spectroscopy (1)
- Photoexcitation (1)
- Photoinduced electron-transfers (1)
- Photoligation (1)
- Photoluminescence quantum yield (1)
- Photon counting detectors (1)
- Photonic baking (1)
- Photonic wire (1)
- Photophysics (1)
- Photopolymer (1)
- Photoswitchable rotaxane (1)
- Phthalocyanines (1)
- Pichia pastoris (1)
- Pigment (1)
- Pigmentanalyse (1)
- Pile integrity testing (1)
- Pile length (1)
- Piles (1)
- Plasma tomography (1)
- Plasma-chemical technique (1)
- Plasmapolymer (1)
- Plasmonic (1)
- Platinum Wavelength dispersive D2XRF (1)
- Polarity probe (1)
- Pollen (1)
- Pollution (1)
- Poly(glycidyl methacrylate) (1)
- Polybrominated diphenylether (1)
- Polycrystalline thin films (1)
- Polycyclic aromatic hydrocarbons (1)
- Polyester (1)
- Polyethylene composites (1)
- Polyethylene glycol (1)
- Polymer adsorption (1)
- Polymer matrix (1)
- Polymer optical fibers (1)
- Polymeric tubes (1)
- Polymorphism (1)
- Polymorphs (1)
- Polysarcosine (1)
- Polystyrene nanoparticles (1)
- Pophycene (1)
- Pore diameter (1)
- Pore throat size (1)
- Pores (1)
- Porosity (1)
- Porous medium (1)
- Porphyrin (1)
- Porphyrins (1)
- Portland cement (1)
- Portland cement Initial hydration (1)
- Post-breakdown laser induced plasma (1)
- Power electronic chips (1)
- Precipitation (1)
- Precision (1)
- Preventive conservation (1)
- Primary method of measurement (1)
- Printed internal standard (1)
- Process Control (1)
- Product certification (1)
- Protein (1)
- Protein analysis (1)
- Protein association (1)
- Protein coating (1)
- Protein corona (1)
- Protein unfolding (1)
- Proteins (1)
- Proteomics (1)
- Provenance studies (1)
- Prozess-Sensoren 4.0 (1)
- Prozess-Spektroskopie (1)
- Précision (1)
- Pt-based drugs (1)
- Pull-out (1)
- Pulse reflection (1)
- Pulse shape analysis (1)
- Purification (1)
- Purity determination (1)
- Pyrroles (1)
- Q4(mAl) sites (1)
- Quality (1)
- Quality infrastructure (1)
- Quantitative NMR (1)
- Quantitative proteomics (1)
- Quantum Yield (1)
- Quantum dot (1)
- Quaternary oxides (1)
- Qumran archaeology (1)
- R package (1)
- RAFT (1)
- REM/EDX (1)
- RFID Sensors systems (1)
- Radionuclides (1)
- Radon transform technique (1)
- Railway (1)
- Raman imaging (1)
- Raman microspectroscopy (1)
- Raman-spectroscopy (1)
- Rate of model oxidation (1)
- Re-XANES (1)
- Reactive plume tracking (1)
- Recombination (1)
- Reconstruction (1)
- Redox-reactions (1)
- Redoxreactions (1)
- Reference (1)
- Reference Material (1)
- Reference gas mixtures (1)
- Reference gas standards (1)
- Reference-free XRF (1)
- Referenced spectroscopic ellipsometry (RSE) (1)
- Referenzmaterialien (1)
- Regenerative capacity (1)
- Registration errors (1)
- Reinforced composites (1)
- Reinforcement (1)
- Relaxation (1)
- Release (1)
- Renewable energy (1)
- Resource Analytics (1)
- Ressourcenanalytik (1)
- Reversibility (1)
- Ribonuclease A (1)
- Ringversuche (1)
- Risk management (1)
- Ru dye sensitizer (1)
- SEIRA Technique (1)
- SHM in civil engineering (1)
- SNR (1)
- SPE-HPLC Automatisierung (1)
- SPME-GC-MS (1)
- SPR effect (1)
- SR-µ-XRF (1)
- STRATAGem (1)
- STXM (1)
- SURMOF (1)
- Safe innovation (1)
- Safety (1)
- Sample changer (1)
- Sample preparation (1)
- Samples (1)
- Scaled Boundary Finite Element Method (1)
- Scanning Transmission Electron Microscopy (1)
- Scanning electron microscopy (1)
- Scanning probe microscopy (1)
- Scanning transmission electron microscopy (1)
- Scattered data (1)
- Schadenstoleranz (1)
- Schadstoffe (1)
- Schweißnähte (1)
- Schwingfestigkeit (1)
- Secondary structure (1)
- Seidenstraßenkultur (1)
- Seismic (1)
- Selective Electron Beam Melting (1)
- Selectivity (1)
- Self assembly (1)
- Self-assembled monolayer (1)
- Self-assembly (1)
- Semiconductor device reliability (1)
- Semtex (1)
- Sensitivity (1)
- Sensor calibration (1)
- Sensor system (1)
- Sensors (1)
- Separation (1)
- Shadowgraphy (1)
- Shear (1)
- Shear exfoliation (1)
- Shear strength (1)
- Shear-horizontal modes (1)
- Sheet resistivity (1)
- Shelf life prediction (1)
- Shell (1)
- Shell nanoparticles (1)
- Shewanella (1)
- Signal amplification (1)
- Signal processing (1)
- Signal-to-noise ratio (1)
- Silanes (1)
- Silicon nitride (1)
- Silicone analysis (1)
- Silk Road (1)
- Silver (1)
- Simple-shear rheometer (1)
- Single cable serial connection (1)
- Single cell analysis (1)
- Sintering (1)
- Skin tissue (1)
- Slabs (1)
- Slippage of weakly linked layers (1)
- Slurry (1)
- Small angle scattering (1)
- Small-angle X-ray scattering (1)
- Small-angle scattering (1)
- Smart sensors (1)
- SnO2 (1)
- SnOx (1)
- Software (1)
- Sol-gel (1)
- Solar-energy (1)
- Solid angle (1)
- Solid phase microextraction (1)
- Solid-state NMR (1)
- Solution plasma (1)
- Solvent polarity (1)
- Sound source (1)
- South Africa (1)
- Spatial light modulation (1)
- Spatial light modulator (1)
- Spatial resolution (1)
- Speciation of Gd-containing MRI contrast agents (1)
- Specific adsorption (1)
- Specific heat (1)
- Specific pore volume (1)
- Specific surface (1)
- Spectra annotation (1)
- Spectral correction (1)
- Spectral induced polarisation (1)
- Spectroelectrochemical Techniques (1)
- Spectrometry (1)
- Spectroscopic ellipsometry (1)
- Spectrum (1)
- Spice (1)
- Spot weld (1)
- Spray drying (1)
- Sputtered thin aluminium film (1)
- Stabilisotopenverdünnungsanalyse (1)
- Stability assessment (1)
- Stabilization of HT-structures at room temperature (1)
- Stabilized dispersions (1)
- Stabilizer (1)
- Stabilty (1)
- Stainless steel (1)
- Standardisierung (1)
- Steel slag (1)
- Stereoscopy (1)
- Strain measurements (1)
- String metal support interaction (1)
- Strong metal support interaction (1)
- Structural characterization (1)
- Structural health (1)
- Subsurface defects (1)
- Sulfur-matrix separatio (1)
- Sulphate-chloride attack (1)
- Super somputing (1)
- Superplasticiser (1)
- Superplaticizers (1)
- Supplementary cementitious materials; (1)
- Supramolecular chemistry (1)
- SurfMOF (1)
- Surface Enhanced Raman Spectroscopy (1)
- Surface analysis; (1)
- Surface chemistry (1)
- Surface enhanced Raman Spectroscopy (1)
- Surface enhanced Raman spectroscopy (1)
- Surface water (1)
- Suspended particulate matter (1)
- Switchable rotaxane (1)
- Symmetry groups (1)
- Synchrotron CT (1)
- Synchrotron radiation X-ray fluorescence (1)
- Synchrotron radiation XPS (1)
- Synthetic aperture focusing (1)
- T-SEM (1)
- TF Material (1)
- TGA (1)
- THz (1)
- THz SAFT Optical layer reconstruction (1)
- THz spectroscopy (1)
- THz time-domain spectroscopy (THz-TDS) (1)
- TNT (1)
- TPA (1)
- TXRF (1)
- TXRF-XANES (1)
- Tandem MS (1)
- Taxonomy (1)
- Temperature sensor (1)
- Tensile (1)
- Tensile strength (1)
- Test gas generation (1)
- Test strip analysis (1)
- Textural controls (1)
- Texture (1)
- The Temple Scroll (1)
- Thermal Waves (1)
- Thermal analyses (1)
- Thermal annealing (1)
- Thermal desorption analysis (TDA) (1)
- Thermal expansion (1)
- Thermal imaging (1)
- Thermal wave (1)
- Thermoacoustics (1)
- Thermomechanical fatigue (1)
- Thermoresponsive polymer (1)
- Thin-film solar cells (1)
- Thiol assay (1)
- Three-dimensional (3D) characterization (1)
- TiO2 coating (1)
- TiO2 films (1)
- Tiered (1)
- Time-of-flight secondary-ion mass spectrometry (1)
- TimeGate (1)
- Tinte (1)
- Tissue (1)
- Titanium (1)
- Titanium dioxide (1)
- ToF (1)
- ToF MS (1)
- ToF SIMS (1)
- Tomography (1)
- Toroids (1)
- Torsional modes (1)
- Total focussing method (1)
- Toxic metals (1)
- Toxicological studies (1)
- Toxicology (1)
- Toxizität (1)
- Trace Humidity (1)
- Trace element (1)
- Trace elements (1)
- Trace humidity (1)
- Transducer (1)
- Transformation products (TPs) (1)
- Transmission (1)
- Transmission electron microscopy (1)
- Tributyltin (1)
- Tributyltin (TBT) (1)
- Trichodiene (1)
- Trinitrotoluene (1)
- Tryptophan (1)
- Turfan Manuskripte (1)
- Turfan manuscripts (1)
- Tyrosine (1)
- UPLC (1)
- UPLC-MS/MS (1)
- UV/VIS spectroscopy (1)
- Ultra-Thin films (1)
- Ultra-thin polymer films (1)
- Ultra-trace analysis (1)
- Ultraschall (1)
- Ultrasonic (1)
- Ultrasonic echo (1)
- Ultrasonic imaging (1)
- Ultrasonic tests (1)
- Uncertainty (1)
- Uncertainty budgets (1)
- Upconversion nanoparticle (1)
- VAMAS (1)
- VCSEL (1)
- VIS-spectrophotometry (1)
- VOC degradation (1)
- VSSA (1)
- Validation and testing infrastructure (1)
- Vanadium oxide (1)
- Vertebroplasty (1)
- Vertical fluid movement (1)
- Vibrations (1)
- Vibrator (1)
- Vickers (1)
- Viscoelastic (1)
- Viscosity (1)
- Void defect (1)
- Volatile organic compounds (1)
- Volatilome (1)
- Voltammetric electronic tongue (1)
- WDX (1)
- Wall paintings (1)
- Wasserstoffsensor (1)
- Waste paper sludge (1)
- Waste-water (1)
- Wastewater (1)
- Water analysis (1)
- Water polluntants (1)
- Water structure (1)
- Water treatment (1)
- Water vapour permeation (1)
- Water-bearing glasses (1)
- Wave propagation (1)
- Weathering (1)
- Well-ordered macrocycle multilayers (1)
- Wheelset (1)
- Wide field (1)
- Writing inks (1)
- X-ray (1)
- X-ray Computed Tomography (1)
- X-ray computed tomography (1)
- X-ray diffraction (1)
- X-ray emission yield (1)
- X-ray fluorescence analysis (1)
- X-ray fluorescence spectroscopy (1)
- X-ray imaging (1)
- X-ray photoelectron spectroscopy (1)
- X-ray radiography (1)
- X-ray spectra (1)
- X-ray spectromicroscopy (1)
- X-ray spectrum (1)
- X-ray tomography (1)
- X-ray yields (1)
- XAFS (1)
- XANES X-ray absorption near edge structure spectroscopy (1)
- XAS (1)
- XRS (1)
- Young’s modulus (1)
- ZIF (1)
- Zearalenon (1)
- Zeolite (1)
- Zerstörungsfreie Prüfung (1)
- Zinc phosphate (1)
- Zinc phthalocyanine (1)
- Zinnoberrot (1)
- absolute measurements (1)
- absorption spectroscopy (1)
- activation energy (1)
- aerodynamics (1)
- affinity chromatography (1)
- aluminum (1)
- analytical approach (1)
- antibodies (1)
- antibody (1)
- atomic force microscopy (1)
- atomic imaging (1)
- atomic weight (1)
- bioanalysis (1)
- bioimaging (1)
- bioisosteric replacement (1)
- ceramics (1)
- cocrystal (1)
- coincidence (1)
- composite (1)
- conductivity (1)
- control chart (1)
- core-shell particles (1)
- cross-reactivity (1)
- cusum (1)
- cyclization (1)
- damage tolerance (1)
- decision-level (1)
- digestion (1)
- dimensional metrology (1)
- dispersity (1)
- dyes (1)
- elastomeric polymer optical fiber POF (1)
- electron backscattering (1)
- electron diffraction (1)
- excitation power density (1)
- explosives (1)
- flash thermography (1)
- fluorescence spectroscopy (1)
- functional PVD coatings (1)
- general fluid mechanics (1)
- geophysics non-destructive testing (1)
- glass fibre paper (1)
- granulation (1)
- graphene (1)
- hapten (1)
- high voltage cable accessories (1)
- holography (1)
- immunoaffinity (1)
- inspection (1)
- ion source (1)
- irreproducibility (1)
- isotope reference material (1)
- k-values (1)
- key comparison (1)
- laser induced plasma (1)
- laser induziertes Plasma (1)
- laser-induced plasma (1)
- laser-spark (1)
- ligand binding assay (1)
- ligands (1)
- liquids material characterization (1)
- mXRF Micro-X-ray fluorescence spectroscopy (1)
- magnesium (1)
- mass spectra (1)
- mechanochemistry (1)
- mercury intrusion capillary pressure (1)
- mesoporous material (1)
- metal phosphonates (1)
- microstructure (1)
- microwave (1)
- milling (1)
- mof (1)
- moisture (1)
- molecular switch (1)
- monitoring (1)
- monoclonal antibody (1)
- multi-sensory (1)
- nanoLC-ESI-MS/MS (1)
- nanocrystals (1)
- nanomaterial (1)
- nerve agent (1)
- non-specific binding (1)
- nuclear magnetic (1)
- numerical uncertainty determination (1)
- numerische Messunsicherheitsbestimmung (1)
- optical excitation (1)
- pH sensing (1)
- paper retraction (1)
- partial discharge (1)
- particle injection (1)
- peer reviewimmunochemistry (1)
- photoemission (1)
- photoluminescence quantum yield (1)
- photovoltaics (1)
- plasma dispersion layers (1)
- plasmonics (1)
- polycondensation (1)
- polyesters (1)
- polyionic liquids (1)
- pore radius (1)
- pore size control (1)
- pore templating (1)
- pores (1)
- porphyrin (1)
- presentation (1)
- probability (1)
- progressive hepatolenticular degeneration (1)
- qNMR (1)
- railway axles (1)
- relaxation time (1)
- replication (1)
- reproducibility crisis (1)
- resonance (1)
- reversible addition fragmentation chain transfer (RAFT) polymerization (1)
- robustness (1)
- sample preparation (1)
- scanning electron microscopy (1)
- screed (1)
- security (1)
- selectivity (1)
- sensing (1)
- sensor (1)
- shell morphology (1)
- shell thicknss and chemistry (1)
- signal-level (1)
- silicone rubber (1)
- simulation (1)
- single cell analysis (1)
- single molecule (1)
- single molecule spectroscopy (1)
- slurry (1)
- small-angle X-ray scattering (1)
- solar cell (1)
- spectral induced polarization (1)
- spray (1)
- spray drying (1)
- stabilizer (1)
- surface enhanced Raman scattering (1)
- surface group quantification (1)
- surface modification (1)
- switching dynamics (1)
- temperature (1)
- terrorism (1)
- thermoresponsive (1)
- ultrasonic excitation (1)
- ultrasonic tests (1)
- vortex shedding (1)
- wave propagation (1)
- zinc oxide (1)
- µXRF (1)
- Éléments traces (1)
- ß-amino-cyclodextrin (1)
- β-amyloid (1–42) (1)
- β-cristobalite structure type (1)
- μ-CT imaging (1)
- μ-CT imaging, (1)
Eingeladener Vortrag
- nein (193)
Applications of fibre reinforced plastic (FRP) composites in modern industries are increasing due to their considerable advantages such as light weight and excellent mechanical properties. Accordingly, importance of operational safety of modern structures made of advanced composites by ensuring the material quality has led to increasing demands for development of non-destructive evaluation (NDE) systems. In the context of a European project entitled “Validated Inspection Techniques for Composites in Energy Applications” (VITCEA), the aim is to develop and validate traceable procedures for novel NDE techniques with contrasting damage detection capabilities in energy related applications such as wind and marine turbine blades, nacelles, oil and gas flexible risers. Accordingly, VITCEA focuses on optimization of ultrasonic tests (UTs) for quantitative defect detection and quality characterization of FRP structures. In this context, the present study describes the ultrasound field in heterogeneous composite materials. The theoretical predictions are compared with simulation results obtained from CIVA a software package dedicated to NDT simulations based on the asymptotic ray theory.
Gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. A current field study focuses on measuring CO2 concentrations for a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time. A 400 m² test site and a corresponding laboratory system were built up to characterize, validate, and optimize the sensor. A calibration routine was developed, which can be applied subsequently to underground installation. First measurement results indicate the potential of the method.
Due to its simplicity, speed and ability to obtain a particle number size distribution, single particle ICP-MS (spICP-MS) has emerged as an important tool for the analysis of nanoparticles (NPs). However, when NPs are suspended in a complex, unknown solution, matrix effects can occur affecting the instrument’s sensitivity. As a result, an over- or underestimation of the particle size is possible.
In this work, a proof-of-concept study of the combination of isotopic dilution analysis (IDA) and spICP-MS compensating for possible matrix effects is presented. As an example, an isotopically enriched 109Ag standard solution was added to silver NPs (Ag NP) suspensions. Different NP suspensions with mean particle diameters between 30 and 80 nm were chosen. The mixtures were analyzed using a quadrupole ICP-MS instrument. Both Ag isotopes (107Ag and 109Ag) were monitored during one experiment. The result show a good agreement with the diameters obtained using conventional spICP-MS.
In a second step, the Ag NPs were suspended in a simulated seawater matrix. Using conventional spICP-MS, a great reduction in the signal intensities and consequently in the particle sizes, was monitored. The application of the IDA-spICP-MS approach on these samples was able to obtain similar diameters compared to the samples without matrix.
Resolution of special capacitive sensors can be improved enormously by replacement of the gaseous material between the capacitor plates by a ceramic dispersion with high permittivity. High dielectric liquid dispersions of ceramic submicron and nano barium titanate powders should be qualified as dielectric fluid with long-term shelf life for this use.
Investigations for the production of stabilized barium titanate dispersions in aqueous and organic liquids by use of different dispersant aids were performed. Characterization of dispersed particles and agglomerates was done by use of zeta potential measurements for aqueous dispersions as well as particle sizing by laser diffraction, ultrasound spectroscopy and dynamic light scattering for aqueous and organic dispersions. Optimization of stability was evaluated by accelerated sedimentation measurements with an optical centrifuge. Best results were achieved for barium titanate dispersions in silicone oil.
According to several recent studies, an unexpectedly high number of landmark papers seem to be not reproducible by Independent laboratories. Nontherapeutic antibodies used for research, diagnostic, food analytical, environmental, and other purposes play a significant role in this matter. Although some papers have been published offering suggestions to improve the situation, they do not seem to be comprehensive enough to cover the full complexity of this issue. In addition, no obvious improvements could be noticed in the field as yet. This article tries to consolidate the remarkable variety of conclusions and suggested activities into a more coherent conception. It is concluded that funding agencies and journal publishers need to take first and immediate measures to resolve these problems and lead the way to a more sustainable way of bioanalytical research, on which all can rely with confidence.
A combined theoretical and experimental investigation was carried out with the objective of evaluating theoretical predictions relating to a two-dimensional airfoil subjected to high amplitude harmonic oscillation of the free stream at constant angle of attack. Current theoretical approaches were reviewed and extended for the purposes of quantifying the bound, unsteady vortex sheet strength along the airfoil chord. This resulted in a closed form solution that is valid for arbitrary reduced frequencies and amplitudes. In the experiments, the bound, unsteady vortex strength of a symmetric 18 % thick airfoil at low angles of attack was measured in a dedicated unsteady wind tunnel at maximum reduced frequencies of 0.1 and at velocity oscillations less than or equal to 50 %. With the boundary layer tripped near the leading edge and mid-chord, the phase and amplitude variations of the lift coefficient corresponded reasonably well with the theory. Near the maximum lift coefficient overshoot, the data exhibited an additional high-frequency oscillation. Comparisons of the measured and predicted vortex sheet indicated the existence of a recirculation bubble upstream of the trailing edge which sheds into the wake and modifies the Kutta condition.
Without boundary layer tripping, a mid-chord bubble is present that strengthens during flow deceleration and its shedding produces a dramatically different effect.
Instead of a lift coefficient overshoot, as per the theory, the data exhibit a significant undershoot. This undershoot is also accompanied by high-frequency oscillations that are characterized by the bubble shedding. In summary, the location of bubble and ist subsequent shedding play decisive roles in the resulting temporal aerodynamic loads.
Spatial and temporal control of thermal waves by using DMDs for interference based crack detection
(2016)
Active Thermography is a well-established non-destructive testing method and used to detect cracks, voids or material inhomogeneities. It is based on applying thermal energy to a samples’ surface whereas inner defects alter the nonstationary heat flow. Conventional excitation of a sample is hereby done spatially, either planar (e.g. using a lamp) or local (e.g. using a focused laser) and temporally, either pulsed or periodical. In this work we combine a high power laser with a Digital Micromirror Device (DMD) allowing us to merge all degrees of freedom to a spatially and temporally controlled heat source. This enables us to exploit the possibilities of coherent thermal wave shaping. Exciting periodically while controlling at the same time phase and amplitude of the illumination source induces – via Absorption at the sample’s surface - a defined thermal wave propagation through a sample. That means thermal waves can be controlled almost like acoustical or optical waves. However, in contrast to optical or acoustical waves, thermal waves are highly damped due to the diffusive character of the thermal heat flow and therefore limited in penetration depth in relation to the achievable resolution. Nevertheless, the coherence length of thermal waves can be chosen in the mmrange for modulation frequencies below 10 Hz which is perfectly met by DMD technology. This approach gives us the opportunity to transfer known technologies from wave shaping techniques to thermography methods. We will present experiments on spatial and temporal wave shaping, demonstrating interference based crack detection.
Advances in scanning electron microscopy (SEM) enable the high-resolution imaging of single nanoparticles (NPs) with sizes well below 10 nm. The SEM analysis in transmission mode (T-SEM) of NPs on thin film supports has many benefits when compared to the analysis of NPs on bulk substrates. The enhanced material (mass – thickness) contrast of the T-SEM imaging mode is well suited for in-depth and, particularly valuable, to very accurate, traceable, lateral dimensional measurements of NPs. Compared to samples prepared on bulk substrates, T-SEM with energy dispersive X-ray spectroscopy (EDS) achieves a drastically improved spatial resolution of the emitted X-rays. The poor signal-to-noise ratio of the X-ray spectra emitted by a single nanoparticle (NP) can be improved by the use of high-sensitivity (high collection solid angle) silicon drift (SDD), energy-dispersive X-ray spectrometers (EDS). The EDS spectral imaging of a single NP with a spatial resolution below 10 nm has become possible. This is demonstrated by means of various examples of nanostructures. Advanced data processing of T-SEM/EDS results sets the stage for the automated classification of NPs by feature analysis. This method combines the detection of morphological structures of interest by image processing of T-SEM micrographs with the chemical classification by EDS.
Zinc oxide is a wide bandgap semiconductor with unique optical, electrical and catalytic properties. Many of its practical applications rely on the materials pore structure, crystallinity and electrical conductivity. We report a synthesis method for ZnO films with ordered mesopore structure and tuneable crystallinity and electrical conductivity. The synthesis relies on dip-coating of solutions containing micelles of an amphiphilic block copolymer and complexes of Zn2+ ions with aliphatic ligands. A subsequent calcination at 400 °C removes the template and induces crystallization of the pore walls. The pore structure is controlled by the template polymer, whereas the aliphatic ligands control the crystallinity of the pore walls. Complexes with a higher thermal stability result in ZnO films with a higher content of residual carbon, smaller ZnO crystals and therefore lower electrical conductivity. The paper discusses the ability of different types of ligands to assist in the synthesis of mesoporous ZnO and relates the structure and thermal stability of the precursor complexes to the crystallinity and electrical conductivity of the zinc oxide.
The presented investigations have proved the principal suitability of the KorroPad method to assess the passive layer stability of stainless steels. The electrochemical mode of action could be described in detail and limitations of the applicability have been demonstrated. The influence of different surface finishes has been investigated and verified by known methods for describing corrosion resistances. As a result, the increased corrosion susceptibility of two ground surfaces has been detected, but also the corrosion resistance of further surface finishes could be confirmed.
In this paper, members of three research teams, namely the Turfan Project of the Berlin BrandenburgAcademy of Sciences and Humanities, the Berlin-based research project on pigments in Central Asianpaper manuscripts, and the Hamburg-based project on the history and typology of Central Asian papermanuscripts, present some of the results of their cooperation. The investigated manuscripts belong tothe Berlin Turfan Collection. On the basis of different examples the contribution of scientific methods tophilological scholarship within a multidisciplinary approach is demonstrated.
Here we present the fabrication of a solid-core microstructured polymer optical fiber (mPOF) made of polycarbonate (PC), and report the first experimental demonstration of a fiber Bragg grating (FBG) written in a PC optical fiber. The PC used in this work has a glass transition temperature of 145°C. We also characterize the mPOF optically and mechanically, and further test the sensitivity of the PC FBG to strain and temperature. We demonstrate that the PC FBG can bear temperatures as high as 125°C without malfunctioning. In contrast, polymethyl methacrylate-based FBG technology is generally limited to temperatures below 90°C.
Due to the increasing utilization of silver nanoparticles in consumer related products, many studies focus on investigations regarding their toxicological potential. This includes investigations concerning uptake, distribution and excretion of the particles. So far, little attention was paid to changes of physical and chemical properties in the human body. During processes like digestion, the question arises whether they can pass this barrier in a nanoscale form. In this study we analytically monitored the changes in the size distribution of silver nanoparticles during an artificial digestion process with the help of small angle x-ray scattering (SAXS). Therefore, we synthesized polyacrylic acid stabilized ultra-small silver nanoparticles with a radius of 3 nm and a size distribution width of 18%. The artificial digestion process mimics the gastro-intestinal passage and simulates the oral, gastric and small intestinal conditions. Additionally, food components like oil, starch, glucose and skimmed milk powder are used to provide a preferably realistic environment.
In absence of any food components the low pH initiates aggregation of the particles in the stomach. However, the particles unexpectedly stabilize in a defined cluster form with a mean radius of 12 nm. By the use of the food components oil and starch we observed that the particles are dispersed again. Now we found a bimodal size distribution of primary particles and aggregates. In contrast to that, with skimmed milk powder only a slight aggregation occurs in the stomach. In the gastric tract the particle distribution is stabilized at a mean volume weighted radius of 5 nm. Hence, skimmed milk powder acts as a colloidal stabilizer. For comparison we also used silver nitrate as a control substance. Surprisingly, we observed a formation of nanoparticles already in the saliva. During the digestion process the distribution narrows and finally in the intestine it shows a stable distribution with a mean volume weighted radius of 3 nm and a small fraction of aggregates. These results indicate that the silver nanoparticles can pass the biological barriers of the digestion process in a nanoscale form but undergo a transformation in the size distribution. However, even from pure silver nitrate nanoparticle formation can be observed. This sketches a complex mechanism in which not only food components but also silver ions cause changes in nanoparticle size and aggregation.
This book is on sensors which are regularly deployed in technologies and processes related to hydrogen production, storage, distribution, and use. Not all types of sensors are equally suitable for specific hydrogen applications. The information in this book is intended to help the reader understand the basics of sensors, sensing technologies, sensor applications, and to provide guidelines for choosing the right sensors and the use of them correctly. Correct deployment of appropriate sensors demands knowledge of the sensing principle and of the physical or chemical quantities being measured. Because of the properties of hydrogen, the potential for its vastly increased use in a future low-carbon economy and possible hazards associated with its use, special attention is paid to hydrogen sensors. This book will not focus on the details of the hydrogen technologies nor on the many safety-related aspects of these technologies. Many books are already available on these topics. Instead the detection principle of hydrogen sensors and other sensor types used, in the dynamic and rapidly developing field of hydrogen technologies, are treated in detail in this book.
In the first chapter a brief overview is presented on basic hydrogen properties and particularly on those properties which are most relevant for safety and for sensing. To illustrate the extensive field of contemporary applications and the exciting possibilities for near future sensor applications, existing and emerging markets using large quantities of hydrogen are mentioned. The role of sensors as devices for monitoring and control of processes and as safety monitoring devices is outlined.
The second chapter gives an introduction to sensing technology and provides the Reader with relevant information pertaining to sensor definitions and classification, sensor metrics, and performance arameters, in addition to background information on sensor preparation technologies and techniques. While there are many books available which provide more exhaustive information on each of these topics, e.g., the level of detail provided in this chapter is sufficient to appreciate the salient features of sensing and sensing Technology which are central to hydrogen safety and monitoring of relevant applications.
Chapter 3 provides a comprehensive overview of emerging and commercially available hydrogen sensors, an explanation of their sensing principle, and important aspects of their performance. A comprehensive and up-to-date account of the theory (physical or chemical principles), design, and practical implementations of hydrogen sensors for use in hydrogen related applications is presented.
Similar information on chemical sensors for other gases, such as oxygen and trace components, which are also highly important in hydrogen technologies because of potential hazards to human health, process safety or facility performance, is provided in Chapter 4.
In Chapter 5 descriptions of physical sensors for temperature, pressure, gas flow, and fire indication, which are also germane for the safe use of hydrogen, are provided.
Standards, codes, and regulatory documents, which provide practical advice and legislative requirements regarding sensor deployment and performance, are described in Chapter 6. This chapter also makes reference to the main procedures for sensor testing in gas Standards including precise analytical methods and reference methods. The chapter concludes with a discussion on sensor selection and some installation guidelines are provided.
In Chapter 7 traditional and emerging processes and technologies involving hydrogen are described. The application of sensors in processes for the production of hydrogen, hydrogen storage, distribution, and the use of hydrogen in stationary and mobile fuel cells is discussed. Furthermore, the use of hydrogen as a coolant and chemical reagent (medium) in various processes is described. The exploitation of sensors for replacing traditional analytical instrumentation is also discussed. Finally supplementary information is provided on hydrogen properties, measuring quantities, and sensor parameters.
Hydrogen can cause unexpected material failure under consideration of stresses (external/internal) during manufacturing, processing or service of the materials. This failure is mostly based on a certain degradation of the mechanical properties. Thus, the correlation of hydrogen trapping vs. a respective microstructure is necessary for high strength steels. Thus, the scope of this work is the improvement of existing hydrogen trap models by verification of activation energies for hydrogen traps as well as the influence of the determination method. In this scope, the thermal desorption method is appropriate to distinguish between different hydrogen traps. Nevertheless, the specimen temperature has to be accounted very carefully in case of calculating the necessary trap energy.
Spatial and temporal control of thermal waves by using DMDs for interference based crack detection
(2016)
Active Thermography is a well-established non-destructive testing method and used to detect cracks, voids or material inhomogeneities. It is based on applying thermal energy to a samples’ surface whereas inner defects alter the non-stationary heat flow. Conventional excitation of a sample is hereby done spatially, either planar (e.g. using a lamp) or local (e.g. using a focused laser) and temporally, either pulsed or periodical. In this work we combine a high power laser with a Digital Micromirror Device (DMD) allowing us to merge all degrees of freedom to a spatially and temporally controlled heat source. This enables us to exploit the possibilities of coherent thermal wave shaping. Exciting periodically while controlling at the same time phase and amplitude of the illumination source induces – via absorption at the sample’s surface - a defined thermal wave propagation through a sample. That means thermal waves can be controlled almost like acoustical or optical waves. However, in contrast to optical or acoustical waves, thermal waves are highly damped due to the diffusive character of the thermal heat flow and therefore limited in penetration depth in relation to the achievable resolution. Nevertheless, the coherence length of thermal waves can be chosen in the mm-range for modulation frequencies below 10 Hz which is perfectly met by DMD technology. This approach gives us the opportunity to transfer known technologies from wave shaping techniques to thermography methods. We will present experiments on spatial and temporal wave shaping, demonstrating interference based crack detection.
The chapter describes the application of electronic noses (multigas sensors) for the quality control of spices and spice mixtures. Electronic noses were successfully applied for headspace analysis of spices. It was demonstrated in many investigations that electronic noses can contribute to the characterization of spices and spice mixtures in order to distinguish spices and spice mixtures, differentiate by origin, growth seasons,and processing,indicate adulteration from original, detect mold infestation. Electronic noses can be used as a fast screening method to provide information about the product quality. However, it needs samples and methods for reference, careful training, and complex calibration to consider influencing and disturbing effects as well as the possible limitations of the instrumentation. The correlation to classical chemical analysis methods is always advisable. Machined olfaction methods are capable to support the sensory analysis; however, they cannot yet substitute them.
We present paper-based test strips for chemical sensing with surface enhanced Raman scattering as detection method. The test strips are prepared on glass fibre paper with silver nanoparticles and a spray method with an airbrush spray setup as a low cost fabrication approach. The properties of the test strips are investigated with three classical Raman analytes rhodamine 6G, 4-aminothiophenol and adenine and optimized for a good reproducibility of the intensity measurements. All test analytes can be identified at low concentrations. For adenine, a concentration series from 10⁻⁴ M to 10⁻⁸ M is measured and the calibration data can be fitted and evaluated with a Langmuir isotherm model. The optimized test strips are applied for the identification of two antibiotics enoxacin and enrofloxacin.
Numerical measurement uncertainty determination for dimensional measurements of microparts with CT
(2016)
Up to now, the only standardized method to determine the measurement uncertainty for computed tomography (CT) is to use calibrated workpieces as specified in the Guideline VDI/VDE 2630 Part 2.1. This paper discusses a promising numerical method for uncertainty determination with help of a virtual metrological CT (VMCT). It gives an explanation of the adjustments, the input parameters and the execution of the simulation. Furthermore, it discusses the first results of uncertainty determination compared to the method of using calibrated workpieces with the aid of two example cases.
The method described here allows to determine the size of the thermal contact between two metal sheets joined by spot welding. This size is a measure for the size of the weld nugget, i.e. the zone melted during the welding process, and thus the quality of the welded joint. The method applies active thermography in transmission or reflection setup. Especially the reflection setup offers an attractive possibility for non-destructive testing when components can be accessed from one side only. The spot weld region is optically heated by laser or flash light radiation. The weld nugget provides the mechanical joint, but also constitutes a thermal bridge between the two welded sheets. The latter will be exploited in this method. The better thermal contact at the weld Nugget contrasts with the surrounding material, where the heat transfer between the two sheets is comparatively low. A major advantage of the described method is the applicability on sheets without any surface treatment. This is achieved by a proper normalization of the data, allowing for a correction of the varying surface emissivity.
Active thermography with lock-in excitation is a non-destructive testing method that is also feasible for testing of carbon fiber reinforced polymers (CFRP). For validating the method extensive investigations were done during a research project in order to advance a standardization process.
The most important parameters of optical and ultrasonic excitation thermography were investigated. For example, the appropriate selection of spectral sensitivity of the used infrared camera systems is important for recording undisturbed thermal signals. Regarding excitation,
influences of excitation power and ultrasonic frequency were studied. Furthermore, material parameters such as CFRP layup are known for strongly affecting the results of
measurement.
Over the past few decades, there has been an increased frequency and duration of cyanobacterial Harmful Algal Blooms (HABs) in freshwater systems globally. These can produce secondary metabolites called cyanotoxins, many of which are hepatotoxins, raising concerns about repeated exposure through ingestion of contaminated drinking water or food or through recreational activities such as bathing/swimming. An ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) multi-toxin method has been developed and validated for freshwater cyanotoxins; microcystins-LR, -YR, -RR, -LA, -LY and -LF, nodularin, cylindrospermopsin, anatoxin-a and the marine diatom toxin domoic acid. Separation was achieved in around 9 min and dual SPE was incorporated providing detection Limits of between 0.3 and 5.6 ng/L of original sample. Intra- and inter-day precision analysis showed relative standard deviations (RSD) of 1.2–9.6% and 1.3 –12.0% respectively. The method was applied to the analysis of aquatic samples (n = 206) from six European countries. The main class detected were the hepatotoxins; microcystin-YR (n = 22), cylindrospermopsin (n = 25), microcystin-RR (n = 17), micro-cystin-LR (n = 12), microcystin-LY (n = 1), microcystin-LF (n = 1) and nodularin (n = 5). For microcystins, the levels detected ranged from 0.001 to 1.51 mg/L, with two samples showing combined levels above the guideline set by the WHO of 1 mg/L for microcystin-LR. Several samples presented with multiple Toxins indicating the potential for synergistic effects and possibly enhanced toxicity. This is the first published pan European survey of freshwater bodies for multiple biotoxins, including two identified for the first
time; cylindrospermopsin in Ireland and nodularin in Germany, presenting further incentives for improved monitoring and development of strategies to mitigate human exposure.
Time-resolved in situ investigation of Portland cement hydration influenced by chemical admixtures
(2016)
Numerous admixtures are used in the building practice to customize the properties of the cement paste during application. The influences of admixtures on the course of cement hydration and formation of hydrate phases have to be considered. Polycarboxylate ether (PCE) based polymeric superplasticizers (SPs) are known to retard the setting of the cement paste. The extent of the retardation differs depending on the molecular structure of the SP. Additionally, the presence of a stabilizing agent (SA) in the cement paste has a retarding side effect on the setting. The initial cement hydration processes and the detailed mechanisms of the retardation influenced by PCEs, as well as their interactions with particular SAs, are insufficiently understood. Up to now, only the results of phenomenological studies were taken into account to describe this retardation process. A detailed structure analysis monitoring the change of the phase composition during the hydration was never applied. Both SP and SA affect the adsorption of the sulphate ions on the clinker particles, causing changes in the formation of ettringite during the initial hydration, and are therefore a crucial part of the setting process itself. Here, the initial hydration of cement influenced by the interaction of SP and SA was monitored in situ by synchrotron X-ray diffraction. The high time resolution of the measurements allowed a continuous detection of the hydrates formed. The hydration was followed from the starting point of water addition and for couple of hours afterwards. The hydration of the levitated cement pellets containing starch as SA was initialized by adding aqueous solutions of different commercial SPs. Changes in the ettringite formation were detected in comparison to the reference hydration of pure cement.
Online low-field NMR spectroscopy of an industrial lithiation reaction step for process control
(2016)
Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectroscopy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory.
Within the project CONSENS, the continuous production of high-value products in small production scale is advanced by introducing benchtop NMR spectroscopy. CONSENS is a research and innovation project on integrated control and sensing for sustainable operation of flexible intensified processes.
This poster will present the first steps of the process integration of a benchtop NMR instrument for a lithiation process and outlines further fields of activity and potential challenges. Hereby, the following issues are going to be addressed: explosion-proof housing for the spectrometer, automation of signal processing (data pretreatment, evaluation and communication to the control system), flow cells and measuring conditions. Furthermore, first online spectra of the lithiation reaction in batch mode were acquired in lab scale. The reaction was performed in a 25 mL glass reactor with thermal jackets for temperature control of the reaction mixture. The Li-HMDS was dosed stepwise by using a glass syringe. First spectra in the proton and fluorine domain were recorded online using a flowrate of 3.5 mL min–1 and a simple 5 mm polytetrafluoroethylene tube (PTFE) as a flow cell.
Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectroscopy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory.
Within the project CONSENS, the continuous production of high-value products in small production scale is advanced by introducing benchtop NMR spectroscopy. CONSENS is a research and innovation project on integrated control and sensing for sustainable operation of flexible intensified processes.
This poster will present the first steps of the process integration of a benchtop NMR instrument for a lithiation process and outlines further fields of activity and potential challenges. Hereby, the following issues are going to be addressed: explosion-proof housing for the spectrometer, automation of signal processing (data pretreatment, evaluation and communication to the control system), flow cells and measuring conditions. Furthermore, first online spectra of the lithiation reaction in batch mode were acquired in lab scale. The reaction was performed in a 25 mL glass reactor with thermal jackets for temperature control of the reaction mixture. The Li-HMDS was dosed stepwise by using a glass syringe. First spectra in the proton and fluorine domain were recorded online using a flowrate of 3.5 mL min–1 and a simple 5 mm polytetrafluoroethylene tube (PTFE) as a flow cell.
Quantitative Online NMR spectroscopy as a direct ratio method of analysis represents a perfect reference for calibration of further process analytical techniques, e.g., optical spectroscopic techniques. In this work we present a combined approach including Online NMR and Raman spectroscopy on a laboratory setup for development of suitable models for process monitoring. Therefore we investigated the absorption process of carbon dioxide in solutions of monoethanolamine, as well as the homogeneous catalyzed hydroformylation reaction of 1-dodecene taking place in an emulsion stabilized by a technical surfactant. The models for Raman spectroscopy were tested and approved during several days of operational studies of miniplant-scale setups for both mentioned applications.
Real Time Imaging of Deuterium in a Duplex Stainless Steel Microstructure by Time-of-Flight SIMS
(2016)
For more than one century, hydrogen assisted degradation of metallic microstructures has been identified as origin for severe technical component failures but the mechanisms behind have not yet been completely understood so far. Any in-situ observation of hydrogen transport phenomena in microstructures will provide more details for further elucidation of these degradation mechanisms. A novel experiment is presented which is designed to elucidate the permeation behaviour of deuterium in a microstructure of duplex stainless steel (DSS). A hydrogen permeation cell within a TOF-SIMS instrument enables electrochemical charging with deuterium through the inner surface of the cell made from DSS. The outer surface of the DSS permeation cell exposed to the vacuum has been imaged by TOF-SIMS vs. increasing time of charging with subsequent chemometric treatment of image data. This in-situ experiment showed evidently that deuterium is permeating much faster through the ferrite phase than through the austenite phase. Moreover, a direct proof for deuterium enrichment at the austenite-ferrite interface has been found.
The preparation and characterization of poly(ionic liquid)s (PILs) bearing a polystyrene backbone via reversible addition fragmentation chain transfer (RAFT) polymerization and their photolithographic patterning on silicon wafers is reported. The controlled radical polymerization of the styrenic ionic liquid (IL) monomers ([BVBIM]X, X = Cl− or Tf2N−) by RAFT polymerization is investigated in detail. We provide a general synthetic tool to access this class of PILs with controlled molecular weight and relatively narrow molecular weight distribution (2000 g mol−1 ≤ Mn ≤ 10 000 g mol−1 with dispersities between 1.4 and 1.3 for p([BVBIM]Cl); 2100 g mol−1 ≤ MP ≤ 14 000 g mol−1 for p([BVBIM]Tf2N)). More importantly, we provide an in-depth characterization of the PILs and demonstrate a detailed mass spectrometric analysis via matrix-assisted laser desorption ionization (MALDI) as well as – for the first time for PILs – electrospray ionization mass spectrometry (ESI-MS). Importantly, p([BVBIM]Cl) and p([DMVBIM]Tf2N) were photochemically patterned on silicon wafers. Therefore, a RAFT agent carrying a photoactive group based on ortho-quinodimethane chemistry – more precisely photoenol chemistry – was photochemically linked for subsequent controlled radical polymerization of [BVBIM]Cl and [DMVBIM]Tf2N. The successful spatially-resolved photografting is evidenced by surface-sensitive characterization methods such as X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The presented method allows for the functionalization of diverse surfaces with poly(ionic liquid)s.
Laser microprobe mass analysis (LMMS) employs local ionization by a focused laser and subsequent mass analysis. At excessive irradiation microplasmas led to undesired distortions. Thus, LMMS was discarded as promising ion source. Effective cooling under ambient conditions resulted in more controllable plasmas and development of laser induced breakdown spectroscopy (LIBS). However, little effort has been made to combine LIBS and ambient MS, since these plasmas only provide microsecond lifetimes. After these, recombination yields uncharged and newly bound species, making them inaccessible for MS. The combination of high repetition rate lasers together with growing knowledge about manipulation of charged species at atmospheric pressure allow overcoming these obstacles.
During the last years quantitative NMR spectroscopy has become a general method for solving complex problems in science and industry. The opportunity of a calibration-free quantification, related to a simple counting of the nuclear spins in the active volume of the spectrometer represents a key advantage comparing to other analytical techniques. With modern NMR systems detection limits in the lower ppm range on a molar basis are accessible in a reasonable time period, which makes it a promising method for purity assessment, as well as applications in metrological research. First experiments showed that qNMR is suitable for gas analysis with respect to components used for production of primary reference gas mixtures. For this a laboratory setup for high-pressure NMR experiments up to 20 MPa (2900 psi) in fluid and gas phase was built and tested.
In this work we show the determination of the composition of high precision mixtures, consisting of liquid and liquefied hydrocarbons commonly supplied in floating piston cylinders. Therefore an experimental setup was developed allowing sampling, as well as circulation of the mixture within a high-pressure NMR tube by using a concentric tubing assembly. Additionally, a piston-cylinder pressure cell was designed and manufactured allowing wide-range volume displacement. Mainly intended for density variation within supercritical fluid experiments, it can also function as a compression element for further increasing of gas-pressure in the system. Equipped with liquid thermostat and a motor-powered screw drive unit it is designed to operate at pressure levels up to 60 MPa (8700 psi) and temperatures up to 130 °C.
Dual orthogonal functionalities in a single material is highly desirable in many fields such as bio-imaging, sensing, coating or diagnostic and therapy. However, a precise and controlled approach to prepare two different functionalities is still a challenging task. Herein, we show the simple preparation method for the synthesis of dual-functional hybrid core/shell/shell nanoparticles consisting of a silica core with a fluorescent and a thermoresponsive polymeric layer. Silica core particles were first coated by a fluorescent layer using surface- nitiated reversible addition-fragmentation chain transfer (RAFT) polymerization. The fluorescent silica nanoparticles were then completely enclosed within a switchable protective coating made of thermoresponsive poly(N-isopropylacrylamide) via RAFT polymerization. Thermoresponsive poly(N-isopropylacrylamide) is known to change its properties according to the surroundings temperature in a reversible and controllable way (LCST behavior). The successful preparation of well-defined dual-functional hybrid core/shell/shell nanoparticles was shown by scanning electron microscopy, thermogravimetric analysis and Fourier transform infrared spectroscopy, while their fluorescence and thermoresponsive properties were confirmed by fluorescence spectroscopy and dynamic light scattering measurements, respectively.
Photo-initiated cross-linking of multifunctional acrylic esters in polymeric binders was investigated based on digital imaging using the Computer-to-Plate (CtP) technology applying laser exposure in the near-infrared (NIR). Generation of initiating radicals occurs by electron transfer from the excited state of the NIR-sensitizer to the radical generator, an onium salt. Iodonium salts derived from several borates and those with the bis(trifluoromethylsulfonyl)imide anion resulted in lithographic materials with high sensitivity. Photo-induced electron transfer plays a major function to generate initiating radicals by a sensitized mechanism but thermal events also influence sensitivity of the coating. Internal conversion was the major deactivation pathway while a certain fraction of NIR-dye fluorescence was also available. A line shape focused laser system with emission in the NIR was successfully used to bake the materials.
This article focuses on the fusion of flaw indications from multi-sensor nondestructive materials testing. Because each testing method makes use of a different physical principle, a multi-method approach has the potential of effectively differentiating actual defect indications from the many false alarms, thus enhancing detection reliability. In this study, we propose a new technique for aggregating scattered two- or three-dimensional sensory data. Using a density-based approach, the proposed method explicitly addresses localization uncertainties such as registration errors. This feature marks one of the major of advantages of this approach over pixel-based image fusion techniques. We provide guidelines on how to set all the key parameters and demonstrate the technique's robustness. Finally, we apply our fusion approach to experimental data and demonstrate its capability to locate small defects by substantially reducing false alarms under conditions where no single-sensor method is adequate.
A systematic study of annealing behavior of drawn PMMA fibers was performed. Annealing Dynamics were investigated under different environmental conditions by fiber longitudinal shrinkage monitoring. The shrinkage process was found to follow a stretched exponential decay function revealing the heterogeneous nature of the underlying molecular dynamics. The complex dependence of the fiber shrinkage on initial degree of molecular alignment in the fiber, annealing time and temperature was investigated and interpreted. Moreover, humidity was shown to have a profound effect on the annealing process, which was not recognized previously. Annealing was also shown to have considerable effect on the fiber mechanical properties associated with the relaxation of molecular alignment in the fiber. The consequences of fiber annealing for the climatic stability of certain polymer optical fiber-based sensors are discussed, emphasizing the importance of fiber controlled pre-annealing with respect to the foreseeable
operating conditions.
A fast quantitative model for the energy spectra of radiation emitted by X-ray tubes is described, handling thin as well as thick plane targets of arbitrary materials. The developed model is based on fundamental interaction cross sections, describing electron and photon transport via numerical integration of discretized distributions. While the focus lies on bremsstrahlung production, modeling of characteristic radiation is fully integrated. The model does not include any free parameters. The validity of the model is shown through comparison with measurements and Monte Carlo simulations for several combinations of target material and acceleration potential between 30 kV and 450 kV.
Synchrotron-radiation XPS analysis of ultra-thin silane films: Specifying the organic silicon
(2016)
The analysis of chemical and elemental in-depth variations in ultra-thin organic layers with thicknesses below 5 nm is very challenging. Energy- and angle-resolved XPS (ER/AR-XPS) opens up the possibility for non-destructive chemical ultra-shallow depth profiling of the outermost surface layer of ultra-thin organic films due to its exceptional surface sensitivity. For common organic materials a reliable chemical in-depth analysis with a lower limit of the XPS information depth z95 of about 1 nm can be performed. As a proof-of-principle example with relevance for industrial applications the ER/AR-XPS analysis of different organic monolayers made of amino- or benzamidosilane molecules on silicon oxide surfaces is presented. It is demonstrated how to use the Si 2p core-level region to non-destructively depth-profile the organic (silane monolayer) inorganic (SiO2/Si) interface and how to quantify Si species, ranging from elemental silicon over native silicon oxide to the silane itself. The main advantage of the applied ER/AR-XPS method is the improved specification of organic from inorganic silicon components in Si 2p core-level spectra with exceptional low uncertainties compared to conventional laboratory XPS.
We report an appropriate preparation of binary isotope calibration mixtures of the three stable isotopes of magnesium to be used in the ab initio calibration of multicollector mass spectrometers (ICPMS and TIMS). For each of the three possible combinations of binary mixtures ("24Mg" + "25Mg", "24Mg" + "26Mg", and "25Mg" + "26Mg"), three individual setups have been prepared under gravimetric control, each of them with an isotope ratio close to unity, and a total magnesium mass fraction close to 20 mg kg-1. The preparation was designed to occur via an intermediate dilution of a parent solution of a highly purified specimen of the isotopically enriched magnesium materials. For the application as calibration mixtures, a complete uncertainty budget was set up, and is presented and discussed in detail, including the aspects that went into the design of the dilution and mixing approach to minimize uncertainty. The principle parameters for the purpose of the later calibration of the mass spectrometers are the absolute masses of isotopically enriched magnesium materials in the primary calibration mixtures. For the first time relative expanded uncertainties U (k = 2) for these masses of ≤0.005% could be achieved for all mixtures.
Flexible electrochromic devices (ECDs) based on Fe(II)-metallo-supramolecular polyelectrolytes (Fe-MEPE) and vanadium oxide are studied in operando by means of x-ray absorption fine structure (XAFS) spectroscopy. The ECDs are blue-purple in the colored state at 0.0 V and become light yellow when a voltage of 1.6 V is applied. The XAFS studies at the K-edge of Fe(II) reveals that the absorption edge is shifted toward higher energies by 1.8 eV in the transparent state. Comparison of two different ECDs and different charge cycles demonstrates the reversibility and repeatability of the process. We attribute the shift to a charge transfer and a change of oxidation state of the ions from Fe2+ to Fe3+. The transition is not accompanied by a noticeable structural change of the octahedral coordination geometry as confirmed by analysis of the extended x-ray absorption fine structure (EXAFS) data. (C) 2015 Elsevier B.V. All rights reserved.
Within the scope of a DIN INS project, a flash thermography round robin test that evaluates reliability, comparability and efficiency of different testing situations is organized. The results give information about the detectability of defects e.g. by their size and depth, the evaluation method and by the materials used. Besides, the influence of equipment and parameters used by the participants on the results were analysed. All of the quantitative results as well as the feedback given by the participants will be presented in a DIN committee in order to contribute to a flash thermography standard.
The identification of different forms of dihydroergocristine (DHEC) was carried out by crystallization from different organic solvents. DHEC was identified as potential template for molecularly imprinted polymers (MIPs) for the epimeric specific analysis of ergot alkaloids (EAs) in food. DHEC was crystallized from different solvents in order to mimic the typical MIP synthesis conditions. Four new solvatomorphs of DHEC were obtained. All solvatomorphs contain a water molecule in the crystal structure, whereas three compounds contain an additional solvent molecule. Based on the conformation of DHEC a comparison with typical EA molecules was possible. The analysis showed that DHEC is a suitable template for MIPs for EAs.
Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission-electron probe microanalysis (FE-EPMA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and synchrotron micro X-ray fluorescence spectroscopy (SR-µ-XRF). This study assesses the accuracy, precision and detection limits of these mostly non-destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE-EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA-ICP-MS analyses required larger gold particles (> 60 µm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA-ICP-MS measurements had lower detection limits, precision was lower than FE-EPMA and SR-µ-XRF. The higher variability in absolute values measured by LA-ICP-MS, possibly due to micro-inclusions, had to be critically assessed. Non-destructive point analyses of gold alloys by SR-µ-XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE-EPMA, but higher than those for elements measured by LA-ICP-MS.
An energy-based method to determine material constants in nonlinear rheology with applications
(2016)
Many polymer-type materials show a rate-dependent and nonlinear rheological behavior. Such a response may be modeled by using a series of spring-dashpot systems. However, in order to cover different time scales the number of systems may become unreasonably large. A more appropriate treatment based on continuum mechanics will be presented herein. This approach uses representation theorems for deriving material equations and allows for a systematic increase in modeling complexity. Moreover, we propose an approach based on energy to determine thematerial parameters.This method results in a simple linear regression problemeven for highly nonlinearmaterial equations. Therefore, the inverse problem leads to a unique solution. The significance of the proposed method is that the stored and dissipated energies necessary for the procedure are measurable quantities. We apply the proposed method to a 'semi-solid' material and measure its material parameters by using a simple-shear rheometer.
A discussion is provided on the relation between non-destructive testing (NDT) and fracture mechanics. The basic tasks behind this are to guarantee the safety of a component at a potential hazard loading event, to specify inspection intervals or, alternatively, of demands on NDT for a fixed inspection regime, to plan accompanying measures for cases of temporary continued operation of structures in which cracks have been detected, and, finally, fatigue strength considerations which take into account initial defects.
Hydrophobic guest molecules like organic dyes and metalion complexes can be introduced into aqueous media via adsorption onto inorganic nanoclay host materials such as nm-sized laponite. Dispersions of these organicinorganic hybrid materials show several advantageous properties like minimum light scattering due to their small size in the nanometer regime, ease of modification, low cost, low toxicity, and long-term stability, making them perfect candidates as signaling units and optically active materials in photonics and biotechnology. In this study, we summarize first findings on the easy-to-make, but chemically and optically fairly complex behavior of nanoclay hybrids for biotechnological applications. The latter includes the preparation of nanomaterials, which are colloidally stable in buffers and in the presence of biomolecules like proteins, and methods to control their surface chemistry. For this purpose, we used two red emitting fluorophores, the small organic dye Nile Red and the rare earth complex Eu(ttfa)3(topo)2, and evaluated the interaction of the red nanoclay hybrids with two model proteins, bovine serum albumin and β-lactoglobulin. We were able to monitor the formation of the protein corona around these hybrids using absorption and luminescence spectroscopy.
Insect behavior is a common source of inspiration for roboticists and computer scientists when designing gas-sensitive mobile robots. More specifically, tracking airborne odor plumes, and localization of distant gas sources are abilities that suit practical applications such as leak localization and emission monitoring. Gas sensing with mobile robots has been mostly addressed with ground-based platforms and under simplified conditions and thus, there exist a significant gap between the outstanding insect abilities and state-of-the-art robotics systems. As a step toward practical applications, we evaluated the performance of three biologically inspired plume tracking algorithms. The evaluation is carried out not only with computer simulations, but also with real-world experiments in which, a quadrocopter-based micro Unmanned Aerial Vehicle autonomously follows a methane trail toward the emitting source. Compared to ground robots, micro UAVs bring several advantages such as their superior steering capabilities and fewer mobility restrictions in complex terrains. The experimental evaluation shows that, under certain environmental conditions, insect like behavior in gas-sensitive UAVs is feasible in real-world environments.