Eingeladener Vortrag
- nein (193)
We have obtained a minute amount of dry ink scratched from the bronze inkwell MS 1655/2. The powder was stored between two glass slides to minimize contamination. For micro analysis by FTIR a sample of the ink powder was transferred into a diamond cell while for confocal Raman spectroscopy a micro sample was placed onto sticky tape. The same portion of the sample was also investigated by scanning electron microscopy, where the elements distribution was determined by EDX.
The aim of our work was to check whether the assumption that the jar was discovered in Qumran can be substantiated. In order to establish the archaeological provenance of the jar we conducted a series of analytical tests on samples of material collected from the jar in April and June 2009. The samples were either found loose within the jar, these being probably constituted by remnants of its original contents, or were clay detached from the inner and outer surface of the jar. In addition, a portion of sand deposit coating the inside of the jar handles was analysed.
Lead (Pb) isotope amount ratios are commonly used in applications ranging from archaeology and forensic sciences to terrestrial and extra-terrestrial geochemistry. Despite their utility and frequency of use, only three certified isotope amount ratio reference materials are currently available for Pb: NIST SRMs 981, 982 and 983. Because SRM 981 has a natural Pb isotopic composition, it is mainly used for correcting instrumental mass discrimination or fractionation. This means that, at present, there are no other certified isotope reference materials with natural Pb isotopic composition that could be used for validating or verifying an analytical procedure involving the measurement of Pb isotope amount ratios.
To fill this gap, two new reference materials, both certified for their Pb isotopic composition, have been produced together with a complete uncertainty assessment. These new reference materials offer SI traceability and an independent means of validating or verifying analytical procedures used to produce Pb isotope amount ratio measurements.
ERM-EB400 is a bronze material containing a nominal Pb mass fraction of 45 mg/kg. ERM-AE142 is a high purity solution of Pb with a nominal mass fraction of 100 mg/kg. Both materials have been specifically produced to assist analysts in verifying or validating their analytical procedures. Note that while one of these reference materials requires the chemical separation of Pb from its matrix (ERM-EB400), the other does not (ERM-AE142). Details on the certification of these isotope reference materials are provided in this report.
Selective Electron Beam Melting (SEBM) is a promising powder bed Additive Manufacturing (AM) technique for near net-shape manufacturing of high-value titanium components. However, as with every emerging technique, the manufacturing processes can still be greatly improved and optimised. In particular, the links between AM settings and the resulting sample porosity is of great interest, as the fatigue life of SEBM parts is currently dominated by the presence of porosity. In this study, the size, volume fraction, and spatial distribution of the pores in model samples have been characterised in 3D, using X-ray Computed Tomography (CT), and correlated to the SEBM process variables. A strong relationship was found with the different beam strategies used to contour, and infill by hatching, a part section. The majority of pores were found to be small spherical gas pores, concentrated in the infill hatched region. Rarer irregular shaped pores were mostly located in the contour region and have been attributed to a lack of fusion between powder particles.
The lecture will discuss the sensitive issue of authentication of the objects of cultural heritage of immense cultural and monetary value if certified to be genuine. It will be made clear that material analysis alone, especially its non-destructive variety conducted by specialists in a single technique, can not prove that the object is genuine. The best material analysis can do, after all appropriate tests have been conducted, is to announce that nothing has been found that contradicts the assumption of genuineness. Moreover, the results of the natural analysis can never be used as the only justification of the authentication in the cases of composite objects such as manuscripts or epigraphs. A certification always requires the expertise of the specialist in the field (be it a historian, paleographer, epigrapher, etc.), whose judgment can be at the most supported by appropriate material analysis.
The most effective approach for testing suspicious artifacts has been established by the forensic science. Here, not the authentication, but the determination of the forgery stands in the focus of the work. Investigation protocols developed within 150 years and constantly improved include a clear statement of the analysis purpose and the definition of plausibility criteria for the possible outcome. The younger sister of the forensics, archaeometry has to overcome additional obstacles such as the heterogeneity of historic material coupled with the scarcity of suitable reference material. Over the last two decades the popularity of archaeometric studies has increased enormously, with the industry-driven development of so-called non-destructive technologies (NDT) that do not require sampling. Further technological developments led to the appearance of NDT methods with extremely small interaction windows (µm range). Each of these methods has limitations that have to be carefully considered when planning the tests of a heterogeneous and often partially degraded historical material. This approach is inherently multi-instrumental, therefore archaeometric and forensic departments unite a number of specialists who work together defining the tasks and the methods involved for their successful completion.
The experimental knowledge about the inks of antiquity and late antiquity rarely goes beyond their visual description. In rare cases, inks typology has been determined by means of microscopy and reflectography, i.e. using their physical and optical properties, respectively. Soot, plant, and iron gall inks form different typological classes of historical black writing materials. Soot ink is a fine dispersion of carbon pigments in a water-soluble binding agent; plant-based ink consists of tannin solution; iron gall-ink presents a boundary case between soot and plant ink— a water soluble preliminary stage (similar to inks from the second group) oxidizes and evolves into a black, insoluble material (similar to the carbon pigments of the first group) when the writing is exposed to air. Each ink class has distinct properties that would readily permit their easy differentiation, if only these historical inks always belonged to just one of the classes above. In reality, inks may contain additives that obscure a clear picture.
All the black inks of the DSS have been hitherto identified as soot inks. Yet some manuscripts, with 1QapGen ar among them, display ink corrosion that is incompatible with the pure soot ink. This type of corrosion commonly observed in medieval manuscripts written with iron gall inks, results from the catalytic action of metallic component in the ink. Early analysis of this ink conducted by Nir El and Broshi in 1996 found copper in the corrosive inks and attributed its presence to the use of bronze inkwells. Re-investigation of the 1QapGen ar ink suggests, however, that the ink composition, soot + copper, agrees well with the ink recipe recorded in the 1st century CE by Dioscorides. Similar inks have been already attested on contemporary Egyptian papyri. The first part of the paper is dedicated to the new results on the inks and corrosion pattern of the 1QapGen ar.
In the second part of the presentation I will focus on the luxury scrolls, a distinct codicological type introduced by E. Tov. Our studies show that the preparation of the writing materials cannot supplement the list of codicological criteria offered by Tov. Therefore, one can divorce the writing material production from its inscription in contrast with the medieval scriptoria practices that included parchment production and copying of the manuscripts.
Material study of inks
(2016)
Our experimental knowledge about the inks of antiquity and late antiquity rarely goes beyond their visual description. In rare cases, inks typology has been determined by means of microscopy and reflectography, i.e. using their physical and optical properties, respectively. Soot, plant, and iron gall inks form different typological classes of historical black writing materials. Soot ink is a fine dispersion of carbon pigments in a water-soluble binding agent; plant-based ink consists of tannin solution; iron gall-ink presents a boundary case between soot and plant ink— a water soluble preliminary stage (similar to inks from the second group) oxidizes and evolves into a black, insoluble material (similar to the carbon pigments of the first group) when the writing is exposed to air. Each ink class has distinct properties that would readily permit their easy differentiation, if only these historical inks always belonged to just one of the classes above. In reality, inks may contain additives that obscure a clear picture.
Even crude observations suggest that the inks of antiquity differed greatly in their composition. We believe, that reconstructing the ink recipes with the help of advanced non-destructive analytical techniques could serve as a powerful accessory in the studies of ancient papyri.
The proposed paper will present a short survey of the methods of material analysis and the challenges offered by ancient inks. (Two) examples of ink studies from the collections of the Israel Museum in Jerusalem and Egyptian Museum in Berlin will conclude the paper.
The international Qumran project coordinated at the BAM, Berlin, resulted in an integrated methodology for determining the original and acquired properties of the skin-based writing surfaces of the Dead Sea Scrolls. This methodology offers a powerful tool for addressing such questions as the provenance, sorting and comparison of manuscripts. In addition, we have developed specific protocols for on-site studies, which were successfully applied to the fragments from the Schøyen collection in Norway. Our studies show that the Dead Sea Scrolls writing surfaces can be divided roughly into three groups: leather, parchments of a light tint, and those of various shades of brown. The latter ones are invariably tanned, whereas the middle group is characterized by the presence of various inorganic salts. Some of the pale parchments, among them the Temple Scroll (11Q19), are remarkably similar to medieval European parchment. Therefore we have formulated the working theory that in the Judaea of the Hellenistic period two different parchment-making traditions existed side by side: an ‘eastern’ one (represented by the tanned parchments of Qumran, closely resembling Aramaic documents from the fifth century BC, and a ‘western’ one (represented by the untanned/lightly tanned ones similar to early Christian Greek parchments).
This division has found support during our first pilot study of the Geniza fragments, in which Babylonian and Palestinian traditions seem to follow the “eastern” and “western” technologies, respectively.
The evolution and socio-geographic distribution of writing inks in late Antiquity and the early Middle Ages build the second focus of the BAM group. We use X-ray fluorescence analysis (XRF) to determine the chemical composition of the inks and NIR-reflectography for their typology. Here the early appearance of the metal containing inks clearly belongs to the western tradition as opposed to the continuous use of soot inks in the East.
Investigation of manuscripts found in sites along the Silk Road shows the history of communication and exchange between Asia and the Mediterranean over the centuries. Different scripts and languages preserved on paper in certain styles provide information about traditions and provenance.
To get an idea of the cultural background of the highly developed painting techniques obvious in some illuminated manuscripts, the material used for writing and painting is analyzed. Singular Sogdian and Tocharian manuscripts from Turfan show text on one side with a colorful painting on the other side of the document. In comparison with other productions of different periods or usages from the site, special features are worked out to characterize cultural roots or influence in the network of relationships. Details analyzed in the most elaborated documents Show various influences led to the colorful masterpieces.
Similar to the success story of digital photography a major upheaval has been observed in digital industrial radiology. This paper is split into 3 parts:
Part 1: Film Replacement and Backscatter Imaging: Computed radiography with phosphor imaging plates substitutes film applications. Digital Detector Arrays enable an extraordinary increase of contrast sensitivity in comparison to film radiography. The increased sensitivity of digital detectors enables the efficient usage for dimensional measurements and functionality tests substituting manual maintenance. The digital measurement of wall thickness and corrosion status is state of the art in petrochemical industry. Photon counting and energy discriminating detectors are applied up to 300 Kv provide increased thickness dynamic and material discrimination by synchronously acquisition of images of the high and low energy part of the spectrum. X-ray back scatter techniques have been applied in safety and security relevant applications with single sided access of source and detector. First inspections of CFRP in aerospace industry were successfully conducted with newly designed back scatter cameras. Numeric modeling is used to design X-Ray optics and inspection scenarios as well as conducting RT training.
Part 2: Computed tomography (CT)
Part 3: Micro Radiography and Micro CT.
Designing artificial macromolecules with absolute sequence order represents a considerable challenge. Here we report an advanced light-induced avenue to monodisperse sequencedefined functional linear macromolecules up to decamers via a unique photochemical approach. The versatility of the synthetic strategy—combining sequential and modular concepts—enables the synthesis of perfect macromolecules varying in chemical constitution and topology. Specific functions are placed at arbitrary positions along the chain via the successive addition of monomer units and blocks, leading to a library of functional homopolymers, alternating copolymers and block copolymers. The in-depth characterization of each sequence-defined chain confirms the precision nature of the macromolecules. Decoding of the functional information contained in the molecular structure is achieved via tandem mass spectrometry without recourse to their synthetic history, showing that the sequence information can be read.We submit that the presented photochemical strategy is a viable and advanced concept for coding individual monomer units along a macromolecular chain.
A metrological approach to improve accuracy and reliability of ammonia measurements in ambient air
(2016)
The environmental impacts of ammonia (NH3) in ambient air have become more evident in the recent decades, leading to intensifying research in this field. A number of novel analytical techniques and monitoring instruments have been developed, and the quality and availability of reference gas mixtures used for the calibration of measuring instruments has also increased significantly. However, recent inter-comparison measurements show significant discrepancies, indicating that the majority of the newly developed devices and reference materials require further thorough validation. There is a clear need for more intensive metrological research focusing on quality assurance, intercomparability and validations. MetNH3 (Metrology for ammonia in ambient air) is a three-year project within the framework of the European Metrology Research Programme (EMRP), which aims to bring metrological traceability to ambient ammonia measurements in the 0.5–500 nmol mol−1 amount fraction range. This is addressed by working in three areas: (1) improving accuracy and stability of static and dynamic reference gas mixtures, (2) developing an optical transfer standard and (3) establishing the link between high-accuracy metrological standards and field measurements. In this article we describe the concept, aims and first results of the project.
In this study a metal-matrix-composite with aluminum matrix and Al2O3 particles was investigated with x-ray refraction topography and in-situ tensile loading. It could be observed that after reaching a certain load the specific surface increased steadily. However, the classical radiographs taken for comparison show no damage in the sample.
Preparation of graphene oxide by cyanuric chloride as an effective and non-corrosive oxidizing agent
(2016)
In this work, we report a new method for the synthesis of graphene oxide (GO) using cyanuric chloride as a non-corrosive oxidizing agent.
The mild conditions, simple purification, and scalability of this method are significant advantages over common approaches in which harsh oxidizing agents are used. Moreover, a major drawback with the Hummers' method, the production of toxic gases, is not an issue with this process. This method is a safe and large-scale alternative for the production of GO under mild conditions.
Light damage to selected organic materials in display cases: A study of different light sources
(2016)
The protection of works of art and cultural assets against light-induced aging is vital when planning exhibitions. Newly developed lighting systems render the selection of suitable light sources more difficult, not least in the context of energy–economical systems. This study accordingly examines different lighting systems (fluorescent tubes, halogen lamps, low-voltage metal halide lamps, and LED lamps) in terms of the damage potential they hold for the materials concerned. The changes in color were evaluated using the CIEDE2000 color-difference formula. This study focuses on selected organic materials and shows that changes in color already occur after only a brief exposure time. The color changes induced by the fluorescent tubes were consistently more intense than those induced by the other light sources. The results obtained with the remaining lamps show that the color changes depend more on the material under investigation than on the source used. The changes determined after a relatively short exposure period (five months) vividly demonstrate that exposing sensitive materials to light for longer terms (as is the case during a permanent exhibition) is most definitely a non-viable option.
Molecular machines are a key component in the vision of molecular nanotechnology and have the potential to transport molecular species and cargo on surfaces. The motion of such machines should be triggered remotely, ultimately allowing a large number of molecules to be propelled by a single source, with light being an attractive stimulus. Here, we report upon the photoinduced translation of molecular machines across a surface by characterizing single molecules before and after illumination. Illumination of molecules containing a motor unit results in an enhancement in the diffusion of the molecules. The effect vanishes if an incompatible photon energy is used or if the motor unit is removed from the molecule, revealing that the enhanced motion is due to the presence of the wavelength-sensitive motor in each molecule.
We present the results of a machine learning (ML)- inspired data fusion approach, applied to multi-sensory nondestructive testing (NDT) data. Our dataset consists of Impact-Echo (IE), Ultrasonic Pulse Echo (US) and Ground Penetrating Radar (GPR) measurements collected on large-scale concrete specimens with built–in simulated honeycombing defects. In a previous study we were able to improve the detectability of honeycombs by fusing the information from the three different sensors with the density based clustering algorithm DBSCAN. We demonstrated the advantage of data fusion in reducing the false positives up to 10% compared to the best single sensor, thus, improving the detectability of the defects. The main objective of this contribution is to investigate the generality, i.e. whether the conclusions from one specimen can be adapted to the other. The effectiveness of the proposed approach on a separate full-scale concrete specimen was evaluated.
Sealing and strengthening of the subsoil by grout injection is a major issue in the field of geotechnical engineering. One commonly applied method is jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty linked with this method is in predicting the resulting column diameter and its material strength. In this paper, we illustrate the application of a newly developed non-destructive quality assurance tool used to determine the diameter of jet grout columns. This approach incorporates standard crosshole and downhole seismic measurements. To demonstrate its effectiveness, we tested the new approach within two-dimensional finite-difference numerical simulations. Additional field tests showed that this tool is also applicable in real site conditions. For this purpose, three jet grout columns were produced with different process parameters in a depth between 3 and 10 m. The evaluated diameters were within 1 and 1.5 m, slightly deviating from the previously predicted range by the jet grouting contractor. Moreover, we were able to detect the base of the columns at a 10-m depth with no significant difficulties. On the other hand, unsaturated, less compacted sands between the groundwater level and surface considerably affected the seismic data, hence complicating the detection of the top of the columns.
Starting out from Flory`s most probable Distribution concept, correct and incorrect evaluations of SEC measurements are discussed. Using the correct mode, polyesters prepared by irreversible and reversible polycondensation methods were studied. Polyesters of α,ω−alkanediols and isophthalic acid or polyesters of diphenols and sebacic acid were prepared by three different irreversible polyconcensation methods. Formation of cyclic oligo and polyesters was monitored by MALDI-TOF mass spectrometry and dispersities were measured by SEC. The results are compared with the theories of Flory and Odian.
Eqilibrated polyesters were prepared by reversible polycondensation of ethyl 6-hydroxycaproate or by alcohol-initiated ring-opening polymerization of ε-caprolactone. Various catalysts were compared. The influence of dilution and of di- or multifunctional initiators was evaluated. Furthermore, equilibrated polylactides were prepared from L- or meso-lactide at 120, 160 and 180°C. A fast even-odd equilibration was discovered in addition to reversible cyclization and intermolecular transesterification. The influence of these different equilibration mechanisms on the dispersity was investigated. The preparative and theoretical consequences are discussed.
The content of the paper is the assessment of the performance of (conventional) measurement techniques (MTs)with respect to the classification of disperse materials according to the EC recommendation for a definition of nanomaterial. This performance essentially refers to the accurate assessment of the number weighted median of (the constituent) particles. All data and conclusions are based on the analytical study conducted as real-world performance testing.
It comprised different types of MTs (imaging, counting, fractionating, spectroscopic and integral) as well as different types of materials. Beside reference materials with well-defined size distribution the study also included several commercial powders (variation of particle composition, morphology, coating, size range and polydispersity). In order to ensure comparability of measurement results, the participants were guided to use uniform protocols in sample preparation, conducting measurements, data analysis and in reporting results. Corresponding documents have been made public, in order to support the reviewing process of the paper, respectively to ensure the reproducibility of data by other users under the same conditions.
The scientific paper relies on a comprehensive set of revised measurement data reported in uniform templates, completely describes the experimental procedures and discusses the MTs’ performance for selected materials in detail. Even more, the study is summarised and evaluated, which leads to recommendations for the use of MTs within a tiered approach of NM characterisation. In addition, the paper critically examines the factors that may affect the outcome of such a comparison among different MTs.
Scanning Electron Microscopy (SEM) or Transmission Electron Microscopy (TEM) ? This is a question, nowadays discussed in EM labs of research and industry involved in the characterization and metrology of nanoparticles. The Scanning principle is adapted to TEM, the Transmission mode is adapted to Ultra High Resolution SEM. Can modern SEM replace TEM, reach atomic resolution even without Cs corrector or nm lateral resolution for X-ray Spectroscopy (EDX)?
Due to the development of a New Cold Field Emission (NCFE) electron source Hitachi SEMs SU9000 and SU8200 can deliver routinely sub-nm image resolution and EDX mappings at very high count rates and a lateral EDX resolution of a few nm. A TiO2 sample provided by BAM was analysed at 30 kV using low kV STEM – simultaneously with the Through-the-lens (TTL) SE detector, the Bright Field transmission and Dark Field transmission signals. By this method a pixel-precise information of the particle’s surface using SE, its chemical nature using DF-STEM and its crystalline structure using Bright Field signal is given in one 40sec scan. The advantage of this observation mode compared to Ultra Low Voltage imaging is outlined.
The design of bright and functional dye–protein conjugates requires hydrophilic and stable fluorophores with high molar absorption coefficients and high fluorescence quantum yields,which must not be prone to dimerization, as well as conservation of protein function and suppression of protein association. Although many synthetic dyes meet these needs, the influence of dye charge on bioconjugate performance is commonly neglected. This encouraged us to assess the spectroscopic properties, antibody functionality, binding behavior, folding, and association of conjugates of the therapeutic antibodies trastuzumab and cetuximab with the red cyanine dyes S0586, S2381,and 6SIDCC (bearing two, three, and six sulfonate Groups respectively.
Our results demonstrate a negligible effect of dye labeling on antibody folding, yet a strong influence of Label charge and density on antibody isoelectric points and association.Especially 6SIDCC decreased strongly the isoelectric points of both antibodies and their heavy or light chains even at low labeling degrees, thus favoring protein association. Although an increasingly negative dye charge reduces Antigen affinity as shown in a competitive immunoassay, all conjugates still bound to cells overexpressing the target of the respective antibody. Obviously, dyes that cause minimum dimerization with a small number of charged groups are best for conjugate brightness, minimum protein association, and strong target binding. This underlines the need to consider dye Charge for the rational design of conjugates with Optimum performance.
In order to ground the debate on the metrics that apply for VSSA determined by adsorption isotherms and to illustrate the consequences of real bimodality for VSSA screening, a bimodal mixture has been selected for systematic investigations. A sample of BaSO4 fine was spiked with 10% g/g of BaSO4 ultrafine. The ultrafine grade is a clear nanomaterial (NM) according to the size criterion with a median Feretmin of 27 nm and the fine grade is clearly a non-NM with a median Feretmin of 249 nm. Because of the number ratio of 300:1, the mixture has to be a NM according to the size criterion. Three independent BET measurements were performed on the mixture by two different labs and resulted in a mean VSSA of 23 m2/cm3 with a standard deviation of 3.3 m2/cm3, which leads to a dminVSSA of 258 nm, and, therefore, would falsely classify the material as a non-NM. This effect was predicted earlier by calculated examples (Roebben et al. 2014) and demonstrates that mixtures of nano- and non-nano multimodal materials very likely lead to false negative classifications. Moreover, the measured VSSA values for the mixture of 23 m²/cm³ are in excellent accord with the value of 24.6 m²/cm³ predicted from the TEM size distributions of the individual materials according to the model described by JRC (Roebben et al. 2014), but are significantly different from the prediction of 309 m²/cm³ obtained from the same TEM size distribution by a particle number weighted approach (Lecloux 2015). The same is true for a 50% g/g mixture. We conclude that the mass-based VSSA approach (Roebben et al. 2014) is equal to the VSSA that is measurable by adsorption isotherms, such as from standardized BET.
A proposal of an inter-laboratory study (ILC) on determination of size and shape distribution of TiO2 nanoparticles (NPs) by transmission electron microscopy is presented. The anatase NPs synthesized in a controllable fashion within the EU/FP7 project SETNanoMetro can be considered as shape-defined (bipyramidal) and are offered to complete the list of case studies already in progress within ISO/TC229/JWG2. The main points of the measurement procedure are presented as well as a proposed procedure to evaluate the size and shape according to the standard operation procedure already developed within SETNanoMetro is discussed. Potential ILC participants and a plan with next step to be carried out are proposed.
A high-performance fiber Bragg grating-based (FBG) sensor device has been developed for the detection of small magnetic fields. Based on a smart multilayer jacket around the fibre over the physical length of the FBG, magnetic fields generated by rotating machine parts, power generators or power cable can be easily detected, analysed and evaluated. Consequently, this innovative, on-line and non-contact inspection method results in an increase in quality and reliability of high-performing machine parts, devices and cables. The basic physical principle is based on a magnetostrictive multilayer system that strains the high-resolution FBG element in presence of magnetic fields. Subsequently, a fixed relationship between induced magnetic field and wavelength change of the FBG element describes the characteristic sensitivity curve. Intensive tests regarding characterisation of this magnetic field FBG sensor have been carried out and its performance has been evaluated.
High Speed, High Resolution imaging spectrometers based on pnCCDs for XRF and XRD applications
(2016)
For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light sources in large accelerator facilities as well as with laboratory light sources or with X-rays from celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF) measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of structure and dynamics of matter.
High Speed X-ray Imaging and Spectroscopy with pnCCDs: XRF, XRD and PIXE measurements (and others)
(2016)
For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in
many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light
sources in large accelerator facilities as well as with laboratory light sources or with X-rays from
celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF)
measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced
X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing
experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will
be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects
in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of
structure and dynamics of matter.
Nowadays, superplasticizers (SPs) are widely used to increase fluidity and reduce water content in concrete; thus, allowing better workability for final applications. The present study will focus on the hydration effect using comb shape polycarboxylates (PCEs), which are known to allow a very low water/cement ratio (w/c of 0.20) or less.Optical methods have been successfully used for the analysis and monitoring of the interactions between a broad variety of nanoscale and molecular systems like nanoparticles of various chemical composition and different types of organic ligands or biomolecules.This encouraged us to assess the potential of these methods, and particularly fluorescence, for the investigation of the interactions that occur at the interface between hydrate surfaces of cement particles and PCE at a very early stage of concrete formation and to differentiate between the impact of PCE’s molecular structures on such interactions.
Today, chemical admixtures like superplasticisers and stabilising agents are extremely important for modern concrete technology. These agents have meanwhile become common practice in concrete technology, but the understanding within the entire system lags far behind their application. The macroscopic rheology of concrete in the presence of superplasticizers strongly depends upon effects on a much smaller scale such as the hydration of the cement, the adsorption of superplasticizers, and the pore solution chemistry.
Using channeling-enhanced energy-dispersive X-ray spectroscopy (EDX), we demonstrate polarity sensitive orientation determination of a non-centrosymmetric crystal in the scanning electron microscope. The authors observe a characteristic asymmetry in the channeling-enhanced, angle-dependent EDX data of a GaAs sample, which is in good agreement to simulations using the dynamical theory of diffraction for the incident electron beam. This allows us to assign the orientation of the GaAs crystal according to the non-centrosymmetric point group. The method shown here overcomes the limitation of a reduced point-group sensitivity of electron backscatter diffraction Patterns and electron channeling patterns for crystalline phases that contain atoms of approximately equal electron scattering cross sections.
Nondestructive flaw detection in polymeric materials is important but difficult to achieve. In this research, the application of magnetite nanoparticles (MNPs) in nondestructive flaw detection is studied and realized, to the best of our knowledge, for the first time. Superparamagnetic and highly magnetic (up to 63 emu/g) magnetite core-shell nanoparticles are prepared by grafting bromo-end group-functionalized poly(glycidyl methacrylate) (Br-PGMA) onto surface-modified Fe3O4 NPs. These Fe3O4-PGMA NPs are blended into bisphenol A diglycidylether (BADGE) based epoxy to form homogeneously distributed magnetic epoxy nanocomposites (MENCs) after curing. The core Fe3O4 of the Fe3O4-PGMA NPs endows the MENCs with magnetic property, which is crucial for nondestructive flaw detection of the materials, while the shell PGMA promotes colloidal stability and prevents NP aggregation during curing. The eddy current testing (ET) technique is firstly applied to detect flaws in the MENCs. Through the brightness contrast of the ET image, surficial and sub-surficial flaws in MENCs can be detected, even for MENCs with low content of Fe3O4-PGMA NPs (1 wt %). The incorporation of Fe3O4-PGMA NPs can be easily extended to other polymer and polymer-based composite systems and opens a new and very promising pathway toward MNP-based nondestructive flaw detection in polymeric materials.
The TiO2 material selected for the present inter-laboratory comparison (ILC) was the bipyramidal anatase UT001 batch synthesized hydrothermally by University of Turin in the frame of the EU/FP7 Project SETNanoMetro and carefully prepared on TEM grids by BAM to be distributed to the ILC participants. A clear measurement protocol including data analysis and reporting (including an xls reporting template) has been also prepared by BAM. 14 of 18 participants have measured and reported results which have been already checked by BAM as being conform to the agreed protocol. After receiving the last results (of 4 participants) the ILC data evaluation will be carried out by BAM in line with agreed ISO/TC229 procedures as for the other case sudies.
IND15 JRP SurfChem: Traceable quantitative surface chemical analysis for industrial applications
(2016)
The SurfChem project has made a significant contribution to traceable quantitative surface chemical analysis for industrial applications by delivering new certified reference materials and test samples for specific technical applications. Regular performance tests of instruments, metrological methodology for the detection of (bio)organic surface species, ambient and non-destructive surface chemical analysis for in-line process control and new in situ characterisation techniques of catalytically active surfaces have been achieved.
Modifying or controlling surface chemistry is important in new product development, quality control and research. This is particularly true where functionality of surfaces, thin films and interfaces are key to the application, such as organic solar cells and devices for medical diagnostics. Surface chemical analysis aims to provide quantitative elemental, chemical state and functional group information from the surface of materials, but requires comparable test data and improved measurement traceability.
Measuring organic layers
(2016)
Many innovative products - from touchscreens to solar panels to pharmaceuticals – utilise multiple organic layers to create complex functionality. New techniques have been developed to remove and measure layers individually enabling improved product development and assisting with quality assurance. However, manufacturers cannot be certain of the depth of layer being removed and new reference materials for these techniques are needed to increase uptake, and remove a major barrier to innovation.
Materials and chemical producers require detailed knowledge of surface chemistry for research into new products. One way to understand a surface without damaging it is to bombard it with an electron beam, causing its atoms to emit characteristic X-rays enabling identification. The measurement of these must be precise as many elements emissions are close in energy – traceable reference materials will ensure instruments using this technique are stable and accurate.
A method is proposed to determine the effective detector area for energy-dispersive X-ray spectrometers (EDS). Nowadays, detectors are available for a wide range of nominal areas ranging from 10 up to 150mm2. However, it remains in most cases unknown whether this nominal area coincides with the “net active sensor area” that should be given according to the related standard ISO 15632, or with any other area of the detector device. Moreover, the specific geometry of EDS installation may further reduce a given detector area. The proposed method can be applied to most scanning electron microscope/EDS configurations. The basic idea consists in a comparison of the measured count rate with the count rate resulting from known X-ray yields of copper, titanium, or silicon. The method was successfully tested on three detectors with known effective area and applied further to seven spectrometers from different manufacturers. In most cases the method gave an effective area smaller than the area given in the detector description.
Ultrasonic imaging systems usually require an array of ultrasonic transducers for data acquisition on a wide area on top of an object under investigation. The goal of an imaging algorithm is the use of reflected ultrasound data to form a recognizable image. Conventional algorithms like SAFT are based on an inverse Huygens' principle and need therefore a dense measurement grid. This requires a big effort in data capturing. For simple and inexpensive measurement different strategies of imaging with reduced amount of data and examples with a manual scanning device on concrete elements are presented.
The investigation of cultural assets often deals with the question of provenance, dating, or attribution to artists or workshops. The analysis of physical properties and chemical composition generates important data for answering cultural-historical questions that cannot be solved by stylistic and art-historical methods alone. Starting from some wooden painted architectural elements from Kocho and one from Bezeklik (III 8592), this paper aims to give some insights into the multi-instrumental approach to the analysis of cultural artefacts.
The Color X-ray Camera CXC or SLcam® is an energy-resolving X-ray camera capable of energy- and space-resolved measurements. It consists of a high-speed CCD detector coupled to a polycapil-lary optic that conducts the X-ray photons from the probe to distinct pixels onto the detector.
The camera is capable of fast acquisition of spatially and energy resolved fluorescence images. A dedicated software enables the acquisition and the online processing of the spectral data for all 69696 pixels, leading to a real-time visualization of the elements distribution in a sample. It was developed in a joint project with BAM, IFG Berlin and PN Sensors.
In this contribution we will mainly discuss the use of the CXC at our beamline, the BAMline at BESSY II and imaging applications of the CXC from different areas, like biology and archaeometry. Additionally new developments for the use of the detector without optics, like wavelength dispersive detection or 1shot-XANES, will be presented.
Gold mosaics, made from gold and glass, are one of the best expressions of Late Antique Byzantine and Early Islamic art. The gold alloys, whose composition seems to indicate that gold coins were re-used to fabricate the tesserae, can be used to provide information on the mosaics chronology. Monetary Byzantine gold is in fact characterized by the presence of Pt, which contents in the gold alloy change over time, but Pt must be measured in 0.2-0.4 µm thickness gold leaves that were beaten to be sandwiched between two glass layers.
To analyze this samples the D²XRF set-up at the BAMline at the BESSY synchrotron in Berlin was used. The combination of a crystal for wavelength dispersion and an energy resolving single photon counting pnCCD allows the realization of this very simple wavelength dispersive detection system. With this system an MDL of 1 μg/g for the determination of Pt in Au under optimal conditions can be reached.
Gold leaf tesserae from nine archaeological sites, covering the period that goes from the 5th c. to the 8th c., were analyzed. The presence of Pt in the majority of the samples confirmed the re-use of coins. The Pt contents separate the samples in three groups, one of which having the same chemical characteristics as the Byzantine gold could be compared to dated coins for chronology. The higher Pt contents for one of other groups suggest
Tattooing practice is adopted worldwide and represents a socio-cultural phenomenon, but the injection into the skin of coloring agents, such as metals might pose a serious health problem. Tattoo ink compounds are in general not officially controlled. Moreover, the origins as well as the chemical and toxicological specifications of these coloring agents are hardly known by the producers, the tattooists and by the consumers. In this view, the aim of this study was to characterize the metal composition of tattoo inks available in the market and to draw attention to the associated risk for human health.
A set of tattoo inks from the brand Kuro Sumi was analyzed by means of Synchrotron-based X-ray Fluorescence spectrometry (Sy-XRF) at BAMline @ BESSY II and Raman Spectroscopy using the XploRA confocal Raman microscope (785 nm laser) at the LIBPhys-UNL. Carbon black, rutile, phtalo blue, phtalo green, helizarin red, helizarin yellow and dioxazine violet were respectively identified in black, white, blue, green, red, yellow and violet inks. However, a wide range of transition and heavy metals, potentially hazardous was revealed by Sy-XRF. A semi-quantitative evaluation has revealed, in some inks, amounts of Cr, Cu, Zn and Pb higher than the allowed according to the resolution adopted by the Council of Europe on the safety of tattoos and permanent make-up.
Integrating fluorescent probes with sensing matrices presents a major challenge because usually, when confined in a rather rigid matrix, fluorophores tend to behave completely different than for instance in the molecular state in solution. The lecture reviews the major strategies that have been devised recently to circumvent such issues with special focus on the works carried out in this field by BAM’s Chemical and Optical Sensing Division. Moreover, it will be shown that by using certain strategies not only can the response behavior be retained but synergistic effects can even endow the hybrid with a much better performance than the probe molecule alone.
The newly developed EXAFS set-up comprises both time- and spatially-resolved EXAFS information simultaneously in a single-shot. This facile, stable and scanningless set-up was tested at the BAMline @ BESSY-II (Berlin, Germany). The primary broadband beam is generated by a filter/X-ray-mirror combination (bandpass). The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by an area sensitive detector based on a CCD camera, in a theta - 2 theta geometry.
The first in situ measurements were successfully carried out and hereby presented. The case-study involved a well known reaction, in which structural changes are induced over time, and continuously measured. We were able to track structural changes within a 1s time resolution.
Toxic metals in tattoo inks
(2016)
Tattooing practice is adopted worldwide and represents a socio-cultural phenomenon, but the injection into the skin of coloring agents, such as metals might pose a serious health problem. Tattoo ink compounds are in general not officially controlled. Moreover, the origins as well as the chemical and toxicological specifications of these coloring agents are hardly known by the producers, the tattooists and by the consumers. In this view, the aim of this study was to characterize the metal composition of tattoo inks available in the market and to draw attention to the associated risk for human health.
A set of tattoo inks from the brand Kuro Sumi was analyzed by means of Synchrotron-based X-ray Fluorescence spectrometry (Sy-XRF) at BAMline @ BESSY II and Raman Spectroscopy using the XploRA confocal Raman microscope (785 nm laser). Carbon black, rutile, phtalo blue, phtalo green, helizarin red, helizarin yellow and dioxazine violet were respectively identified in black, white, blue, green, red, yellow and violet inks. However, a wide range of transition and heavy metals, potentially hazardous was revealed by Sy-XRF. A semi-quantitative evaluation has revealed, in some inks, amounts of Cr, Cu, Zn and Pb higher than the allowed according to the resolution adopted by the Council of Europe on the safety of tattoos and permanent make-up (PMU.
Multiplexed bead-based array formats play an increasingly important role in analytical laboratories. Due to the high surface-to-volume ratio, fast reaction kinetics and modular assay design, these sensor formats are applied in clinical diagnostic, drug development and classical biosensors with great success.
As the spherical platform, researchers utilize micron sized particles made from polymeric or silica material. Such beads are commercially available from vendors such as BD or Luminex. However, we have encountered several problematic issues which accompany these platforms: first, bigger sized beads, which are required for particle handling reasons, are difficult to prepare with high monodispersity - a key requirement for cytometric application. Second, plain beads, made from either polymer or silica, have each several disadvantages such as inferior scattering properties in case of silica or limited flexibility for coupling strategies in the case of latex beads.
In order to overcome this problem, we have developed a versatile core-shell (CS) platform which consists of a polymeric core with a structurally controlled silica shell. In our approach, the core building block can be easily prepared with high yields and high monodispersity in a dispersion polymerization from approximately 500 nm to 1.3 µm. Then, silica is coated in a classical sol-gel process to protect the core with a stable yet modifiable surface (see SEM image in Figure 1, platform). Here, we combine ideal scattering properties and easy preparation of the polymeric core with the chemical flexibility of a silica surface. Moreover, the additional shell domain adds density to the composite, which makes particle handling feasible also for nanometer sized beads.
In this contribution we present proof-of-principle results of competitive immunoassays with fluorescence detection using our CS beads – each performed in mix-and-read fashion without washing steps. All sizes are applicable in cytometric read-out which and can be used for size encoding (see Set 1 to 3 in Figure 1, size encoding). However, further multiplexing for a set of at least 20 parameters can be achieved by swelling hydrophobic dyes into the core. To the same time, precise tuning of the surface with mixed silane layers allowed us to improve the selectivity towards small molecules in competitive immunoassays significantly (see example in Figure 1, Application). We believe that our platform allows researchers to gain access to superior assay performance in combination with a low-threshold approach for the synthesis of the spherical platform.
Since more than 20 years, optical spectroscopic techniques, in particular fluorescence-based methods, are on the rise in many different areas of chemical and biochemical analysis, with no end being in sight.1,2 Advances in miniaturization and remote applications on one hand and ground-breaking developments in microscopy and laser-based high-throughput instrumentation on the other hand have fuelled these developments substantially.3,4 At the core of utmost of these applications however is not only the instrument, but a small entity that is able to absorb and emit photons and thus to report on the actual (bio)chemistry that is going on in a particular sample of interest.5,6 Besides intense research on various types of luminescent particles (e.g., quantum dots and carbon dots) and proteins, dye chemistry has thus seen its revival and the number of publications dealing with the design, synthesis and application of new fluorescent dyes as probes, stains, labels or indicators is still continuing to grow.
Among the various classes of dyes available as bright fluorophores for a wavelength range that is compatible with many (bio)analytical applications and the respective instrumentation, in particular pyrrolic dyes that do not belong to the classical porphyrins or phthalocyanines have received strong attention recently. Starting perhaps with the revival of the traditional boron-dipyrromethene laser dye ca. 15 years ago,7 these so-called BODIPYs have developed into a colourful spectrum of different derivatives.8 However, the interest in expanding the range of pyrrole-containing π-systems beyond BODIPYs has also constantly increased and has brought about several other pyrrole-based ring systems such as diketopyrrolopyrroles9 or dipyrrolonaphthyridinediones which possess a favourable brightness and other interesting properties. The present contribution will give a critical overview of the field, pinpointing advantages and prospects as well as discussing potential aspects of improvement with an emphasis on the chemical sensing and the longer wavelength range.
Macrocycle-containing fluorescent probes continue to be one of the most popular classes of indicator molecules for the sensitive optical detection of ionic inorganic analytes, in particular metal ions, since the first integration of crown ether building blocks into chromophoric π systems more than 30 years ago. However, whereas a large multitude of such probes have been described for operation in organic or mixed aqueous environments, the step to realistic analytical media such as water samples, aqueous food extracts or body fluids is still scarce. On one hand, this is due to considerably low complex stability constants for instance for alkali and alkaline-earth metal ions. On the other hand, many classes of organic dyes that show favourable spectroscopic properties and ion-induced responses in organic solvents are not soluble in neat aqueous media and/or exhibit only significantly quenched fluorescence, even if transition metal ions are binding strongly to the receptor unit. A way to circumvent such problems in a rather simple manner is the steric incorporation of fluorescent probes into mesoporous silica nanomaterials. The local polarity in such pores, whether nascent or modified appropriately with functional silanes, resembles much more a quasi-organic environment while at the same time allowing for free diffusion of water and its cargo.
Two examples of powerful hybrid signalling systems will be presented, utilizing charge transfer-type indicator molecules that show inferior sensing properties in their molecular state. One example discusses mercury(II) determination over an extended concentration range and the other discusses silver(I) and mercury(II) discrimination simply on the basis of photophysical effects retained in the hybrid materials.