Analytische Chemie
Filtern
Erscheinungsjahr
- 2016 (637) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (214)
- Vortrag (193)
- Posterpräsentation (131)
- Beitrag zu einem Tagungsband (69)
- Sonstiges (10)
- Buchkapitel (6)
- Dissertation (5)
- Beitrag zu einem Sammelband (3)
- Forschungsbericht (3)
- Monografie (1)
Sprache
- Englisch (637) (entfernen)
Schlagworte
- XPS (25)
- Fluorescence (23)
- Concrete (19)
- Nanoparticles (19)
- Synchrotron (18)
- Simulation (16)
- NEXAFS (15)
- BAMline (13)
- LIBS (13)
- Mechanochemistry (13)
Eingeladener Vortrag
- nein (193)
Synchrotron-radiation enables the adjustment of the XPS information depth and, thus, the visualization of depth profiles of the elemental composition within the first 10 nm of a surface. This project deals with the analysis of core-shell nanoparticles. It constitutes first steps towards a valid methodology for studying the surface chemistry of nanoparticles in a quantitative and accurate manner.
A collisional-dominated model of a laser induced plasma will be presented which includes the coupled Navier-Stokes, state, radiative transfer, and material transport equations and incorporates plasma chemistry through the equilibrium approach based on the use of atomic and molecular partition functions. Simple chemical systems are modeled including ablation of Si, C, SiC, CaCl2 in N2 or Ar atmospheres with the formation of molecules N2, C2, Si2, CN, Cl2, SiN, SiC, CaCl, CaCl2 and their corresponding positive and negative ions. The model is used to study evolution of number densities of atomic and molecular species in the expanding plasma plume. The distribution is compared to experimental observations obtained by optical imaging and tomography. The model and experiment serve to elucidate mechanisms of molecular formation in LIPs, the topic which has recently received much attention in the LIBS community.
A collisional-dominated model of a laser induced plasma will be presented which includes the coupled Navier-Stokes, state, radiative transfer, and material transport equations and incorporates plasma chemistry through the equilibrium approach based on the use of atomic and molecular partition functions. Simple chemical systems are modeled including ablation of Si, C, SiC, CaCl2 in N2 or Ar atmospheres with the formation of molecules N2, C2, Si2, CN, Cl2, SiN, SiC, CaCl, CaCl2 and their corresponding positive and negative ions1,2. The initial conditions are specially chosen to emulate the plasma state on the onset of expansion just after the laser pulse had ended.
The model is used to study evolution of number densities of atomic and molecular species in the expanding plasma plume. The distribution is compared to experimental observations obtained by optical imaging and tomography. The model and experiment serve to elucidate mechanisms of molecular formation in LIPs, the topic which has recently received much attention in the LIBS community.
Two topics will be addressed: (1) calibration-free LIBS based on Monte Carlo spectral optimization and (2) insight into the possibility of simultaneous elemental and molecular analysis by LIBS. Both topics heavily rely on modeling of laser induced plasma and are closely connected to experiment. In Monte Carlo LIBS (MC LIBS), concentrations are found by fitting model-generated synthetic spectra to experimental spectra. The model of a static uniform isothermal plasma in local thermodynamic equilibrium is employed. Many configurations of plasma parameters and their corresponding spectra are simultaneously generated using a graphic processing unit (GPU). Using the GPU allows for the reduction of computational time down to several minutes for one experimental spectrum that presents the significant progress in comparison with earlier versions of MC LIBS. The method is tested by analyzing industrial oxides containing various concentrations of CaO, Fe2O3, MgO, and TiO2. The agreement within several percent between found and certified concentrations is achieved. Next, a newly developed collisional-dominated model of a laser induced plasma is introduced. The model includes the coupled Navier-Stokes, state, radiative transfer, and material transport equations and incorporates plasma chemistry through the equilibrium approach based on the use of atomic and molecular partition functions. Simple chemical systems are modeled including ablation of Si and C in N2 and Ar atmospheres.The model is used to study evolution of number densities of atomic and molecular species in the expanding plasma plume. The distribution is compared to experimental observations obtained by optical imaging and tomography. To further verify the model, dynamic plasma
The equation of state for plasmas containing negative atomic and molecular ions (anions) is modeled. The model is based on the assumption that all ionization processes and chemical reactions are at local thermal equilibrium and the Coulomb interaction in the plasma is described by the Debye–Hu¨ckel theory. In particular, the equation of state is obtained for plasmas containing the elements Ca, Cl, C, Si, N, and Ar. The equilibrium reaction constants are calculated using the latest experimental and ab initio data of spectroscopic constants for the molecules CaCl2, CaCl, Cl2, N2, C2, Si2 , CN, SiN, SiC, and their positive and negative ions. The model is applied to laserinduced plasmas (LIPs) by including the equation of state into a fluid dynamic numerical model based on the Navier–Stokes equations describing an expansion of LIP plumes into an ambient gas as a reactive viscous flow with radiative losses. In particular, the formation of anions Cl-, C-, Si-, Cl2, Si2, C2 , CN-, SiC-, and SiN- in LIPs is investigated in detail.
Purity statements of high purity materials serving as primary standards by GDMS.
Primary standards are materials known for their total purity and therefore appropriate to realise the link with the International System of Units (SI). The realisation and dissemination of primary standards is of fundamental importance for comparability of measurement results through traceability in all fields of chemical analysis.
To serve as a primary standard for element determination the total purity of a high purity material needs to be measured. In order to achieve a sufficiently small uncertainty (i.e. < 0.01%) this involves determining all possible impurity contributions and to subtract their sum from the ideal purity of 100%.
GD-MS has the potential to reduce the effort for purity determination, as a fast sensitive multi-element analysis without extensive sample preparation. Similar to other solid sampling techniques, glow discharge
requires calibration link the measured signal and the content of the impurities in the matrix.
The use of the concept Relative Sensitivity Factors (RSFs) provides good approximations especially for high purity materials. However, it only works with a wide uncertainty of the results.
The preparation of synthetic pressed powder samples by different modifications of liquid and powder doping used for the determination of both metallic and none-metallic impurities are described. Efficient determination of metallic impurities by GD-MS via differential and absolute measurements with a significantly reduced target uncertainty of 20 % for absolute measurements using liquid doped pressed powder calibration could be achieved. The determination of impurities has been evaluated by independent analytical methods such as HR-ICP-MS, ETAAS; CGHE and combustion analysis
Under the assumption of local thermal equilibrium, a numerical algorithm is proposed to find the equation of state for laser-induced plasmas (LIPs) in which chemical reactions are permitted in addition to ionization processes. The Coulomb interaction in plasma is accounted for by the Debye–Hückel method. The algorithm is used to calculate the equation of state for LIPs containing carbon, silicon, calcium, chlorine, nitrogen, and argon. The equilibrium reaction constants are calculated using the latest experimental and ab initio data of spectroscopic constants for the molecules N2, C2, Si2, CN, Cl2, SiN, SiC, CaCl, CaCl2 and their positive and (if existed) negative ions. The algorithm is incorporated into a fluid dynamic numerical model based on the Navier–Stokes equations describing an expansion of LIP plumes into an ambient gas. The dynamics of LIP plumes obtained by the ablation of SiC, CaCl2, solid silicon, or solid carbon in an ambient gas containing N2 and Ar is simulated to study formation of molecules and molecular ions. A particular attention is paid to formation of anions Cl−, Cl2−, Si2−, C2−, CN−, and SiN− in LIPs.
We report on the in situ investigation of mechanochemical syntheses of metal phosphonates. The metal phosphonates are formed in milling reactions starting from a metal acetate and a phosphonic acid. The conversions are observed by synchrotron PXRD and Raman spectroscopy to shed light on the reaction mechanisms including possible intermediates.
Fire-gilding or amalgam gilding is a historical technique for the gilding of objects. The object to be gilded is coated with an amalgam (a solution of gold (Au) in mercury (Hg)). By heating, the largest part of the Hg is subsequently evaporated and there remains a gold layer, containing still detectable amounts of Hg.
The information on the used gilding technique might be crucial for the conservation and preservation of archaeological objects. Therefore, the main objective of this work is the detailed understanding of the behaviour of Hg under conditions of fire gilding. I.e. the understanding of the diffusion and evaporating behaviour of Hg, depending on parameters like substrate material (silver, copper, bronze, brass...), heating temperature and duration, and the resulting Hg depth profiles under these conditions. Secondary objective is the establishment of a measurement protocol for the unambiguous identification of different types of gilding, based solely on non-destructive methods, which can be applied to historical samples.
In a first step, fire-gilded samples have been prepared on Cu and Ag sheet metal, respectively. Some of the gildings were produced by a professional goldsmith; another set of samples was produced under laboratory conditions. These samples have been examined with NAA (neutron activation analysis) and SR-XRF (synchrotron radiation induced X-ray fluorescence). First results of these measurements will be presented and discussed.
Wilson´s disease (WD) is a rare genetic disorder of the copper metabolism, causing the accumulation of copper in different organs, including the liver, the central nervous system and cornea. This way, WD initiates manifold hepatic, neurological or psychiatric symptoms. To learn about the elemental distribution and present species in WD, liver samples were analyzed by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), micro X-ray fluorescence (μXRF) and X-ray absorption near edge structure spectroscopy (XANES).
Within this work, LA-ICP-MS was applied to study the distribution of copper and iron in human liver samples, which were collected by a liver biopsy of WD and control patients within a medical investigation. The analysis by LA-ICP-MS was performed with a 213 nm Nd:YAG laser using a spatial resolution of 10 μm and a scan rate of 20 μm/s. In a next step, copper and iron were quantified by LA-ICP-MS using homemade matrix-matched standards made of gelatin. Results showed an inhomogeneous copper and iron distribution in human liver with hotspots up to several thousand micrograms per gram liver within the hepatocytes.
Additionally, results for the elemental distribution in WD were validated by means of synchrotron radiation-based μXRF with a beam size of 4 μm at the BAMline at BESSYII (Helmholtz-Zentrum Berlin). Furthermore, XANES was performed to identify the present oxidation states of copper in WD, indicating a mixture of copper(I) and copper(II) within the liver tissue.
In the contemporary medicine, rhodanine staining is routinely used to determine the copper distribution in liver tissues. Nevertheless, this method does not provide results with a high sensitivity in comparison to LA-ICP-MS. Therefore, the presented LA-ICP-MS method offers a new possible diagnostic tool. These results may also contribute to a better understanding of Wilson´s disease and its development.
Fire-gilding or amalgam gilding is a historical technique for the gilding of objects. The object to be gilded is coated with an amalgam (a solution of gold (Au) in mercury (Hg)). By heating, the largest part of the Hg is subsequently evaporated and there remains a gold layer, containing still detectable amounts of Hg.
The information on the used gilding technique might be crucial for the conservation and preservation of archaeological objects. Therefore, the main objective of this work is the detailed understanding of the behaviour of Hg under conditions of fire gilding. I.e. the understanding of the diffusion and evaporating behaviour of Hg, depending on parameters like substrate material (silver, copper, bronze, brass...), heating temperature and duration, and the resulting Hg depth profiles under these conditions. Secondary objective is the establishment of a measurement protocol for the unambiguous identification of different types of gilding, based solely on non-destructive methods, which can be applied to historical samples.
In a first step, fire-gilded samples have been prepared on Cu and Ag sheet metal, respectively. Some of the gildings were produced by a professional goldsmith; another set of samples was produced under laboratory conditions. These samples have been examined with NAA (neutron activation analysis) and SR-XRF (synchrotron radiation induced X-ray fluorescence). First results of these measurements will be presented and discussed.
Zn is known to be located in the reactive centers of various enzymes, which play a major role in the mineralization process at sites where new bone formation occurs. In addition, elevated Zn levels are supposed to increase the proliferation rate of osteoblasts [1] and may lead to a stimulation of bone formation in vitro and in vivo [2]. Consequently, Zn seems to play an essential role in bone formation and mineralization through various pathways. We thus expected Zn levels to be altered at sites of extensive bone formation like in the case of fracture healing.
We measured the same areas on human bone samples with both a scanning confocal synchrotron radiation induced micro X-ray fluorescence (SR-μXRF) at the FLUO beamline (ANKA) and a full-field Color X-ray Camera at the BAMline (Bessy II) setup in order to find the ideal SR-μXRF imaging method to investigate trace element distributions in bone samples. As zinc is a trace element of special interest in bone, the setups were optimized for Zn detection. The setups were compared concerning count rate, required measurement time and resolution. We could show that the ideal method is depending on the element of interest. While for Ca (a major constituent of the bone with a low energy of 3.69keV for K) the Color X-ray Camera provided us with a higher resolution in the plane, for Zn (a trace element in bone) only the confocal SR-μXRF was able to sufficiently image the distribution.
Biopsies of healing osteoporotic fractures (Vertebral compression fractures (VCFs)) were investigated in regard to their Zn distribution. The samples were measured with a confocal SR-μXRF setup with a 10 μm x 15 μm resolution at the FLUO beamline at ANKA. As we found increased Zn levels, which seemed to be accumulated in narrow structures between bone packages we also investigated thin cuts (4 μm thick) of two sample areas with a higher resolution of 1 μm x 1 μm (monochromatic beam with E= 17 keV) at B16 at Diamond SR facility.
We will present the advantages and disadvantages of all three SR-μXRF setups (ANKA FLUO beamline, Bessy II BAMline, and Diamond B16) for imaging elemental distributions in bone with a focus on Zn. We will also show the distribution of Zn in healing VCFs.
Airborne particulate matter is an issue of growing concern in industrialized countries. Particles with diameters of less than 10 μm (especially those smaller than 2.5 μm) can enter the human respiratory system and contribute to various diseases depending on their chemical composition and the chemical bonding state, in which elements are present. This chemical speciation can be obtained using X-ray absorption near-edge structure analysis (XANES), which requires a tunable excitation source and therefore has to be carried out at synchrotron facilities. Our special interest lies on the analysis of indoor airborne particulate matter, as particle composition and health effects of outdoor particles have been studied abundantly. For this work, samples were collected in various office rooms in the Atominstitut (ATI) building.
The BAMline at BESSYII features a double-multilayer monochromator (DMM) and a double-crystal monochromator (DCM). The DCM offers an energy resolution E/ΔE of around 103, which makes it suitable for XANES applications. The ATI SR-TXRF vacuum chamber, formerly located at HASYLAB, Beamline L, is now available at the BAMline. The chamber offers a sample changer for up to 8 quartz reflectors and a 30 mm² silicon drift detector (SDD) was used. Aerosol samples were produced using a modified three-stage Dekati™ impactor. For this work, only the coarse (2.5 to 10 μm) and the fine particle fraction (1 to 2.5 μm), were of interest. XANES results of Cr, Cu and Zn will be presented on this poster.
The X-ray Fluorescence beamline at ELETTRA operates in partnership with the IAEA an ultra-high vacuum instrument with a 7-axis manipulator suitable for a variety of X-ray analytical techniques, such as grazing incidence and total reflection X-ray fluorescence analysis (GI-XRF and TXRF), X-ray reflectometry (XRR) and XANES. Samples were produced using a four-stage Sioutas Personal Cascade Impactor. With this impactor, it is possible to produce size-fractionated samples down to the sub-μm range (Stages: A > 2.5 μm, B 1 to 2.5 μm, C 0.5 to 1 μm and D 0.25 to 0.5 μm). Direct sampling was performed on siliconized 25 mm Si wafers suitable for TXRF. Cu-K edge SR-TXRF-XANES analysis was carried out for samples of all impactor stages. Results of these experiments will be shown.
Wilson´s disease, a rare genetic disorder of the copper metabolism, causes the copper accumulation in various organs, leading to manifold hepatic, neurological and psychiatric symptoms. To study the elemental distribution, human Wilson´s disease liver samples were analyzed by means of LA-ICP-MS. Results demonstrated an inhomogeneous copper and iron distribution in human liver with hotspots of very high intensities. Both elements were quantified by an external calibration using matrix-matched standards made of gelatin, showing concentrations up to several thousand micrograms per gram. Additionally, results were validated by means of synchrotron radiation based μXRF at the BAMline at BESSYII (Helmholtz-Zentrum Berlin).
Airborne particulate matter is an issue of growing concern in industrialized countries.
Particles with diameters of less than 10 μm, in particular those with less 2.5 μm, are of special
concern, as they can enter the human lungs and contribute to various cardiovascular and
respiratory diseases. As the composition and health effects of airborne particles in urban, rural
and industrial outdoor air has been studied abundantly, our focus lies on the analysis of
airborne particle samples collected indoors, which may also have a significant effect on
human health, depending on the chemical composition of the particles and the chemical
bonding state, in which elements are present. This chemical speciation can be obtained using
X-ray absorption near edge structure (XANES) analysis, which requires a tunable excitation
source and therefore has to be carried out at synchrotron facilities. For this work, samples
were collected in office rooms of the Atominstitut building.
The BAMline at BESSYII, Berlin, features a double-multilayer monochromator (DMM) and a
double-crystal monochromator (DCM). The DCM offers an energy resolution E/ΔE of around
103, which makes it suitable for X-ray absorption fine structure (XAFS) applications. The
Atominstitut SR-TXRF vacuum chamber, formerly located at HASYLAB, Beamline L, is
now available at the BAMline. The chamber offers a sample changer for up to 8 quartz
carriers suitable for total reflection X-ray fluorescence analysis (TXRF) and was equipped
with a 30 mm² silicon drift detector (SDD). Aerosol samples were produced using a modified
three-stage Dekati™ impactor. For this work, only the coarse (2.5 to 10 μm, Stage 2) and the
fine particle fraction (1 to 2.5 μm, Stage 3), were of interest. XANES analysis was performed
for the elements Cr, Cu and Zn. Oxidation states of these 3 elements will be presented.
The X-ray Fluorescence beamline at ELETTRA operates in partnership with the IAEA an
ultra-high vacuum instrument with a 7-axis manipulator suitable for a variety of X-ray
analytical techniques, such as grazing incidence X-ray fluorescence analysis (GI-XRF),
TXRF, X-ray reflectometry (XRR) and XANES. Samples were produced using a four-stage
Sioutas Personal Cascade Impactor. With this impactor, it is possible to produce sizefractionated
samples down to the sub-μm range (Stages: A > 2.5 μm, B 1 to 2.5 μm, C 0.5 to
1 μm and D 0.25 to 0.5 μm). Direct sampling was performed on siliconized 25 mm Si wafers
suitable for TXRF. Cu-K edge SR-TXRF-XANES analysis was carried out for samples of all
impactor stages. Results of these experiments will be shown.
The physico-chemical characteristics of TiO2 coatings can greatly influence their final performance. In SETNanoMetro, different deposition procedures are being set for applying films of TiO2 NPs with defined and homogenous thickness on supports of interest for the applications studied in the project. The selected substrates are the following: (i) Silica glasses for photocatalytic measurements, (ii) Ti-alloys for orthopedic and/or dental prostheses, and for cell cultures, and (iii) Conductive glasses (e.g. Fluorine doped Tin Oxide, FTO) for dye-sensitized solar cells. From the different film deposition procedures studied within the project Self-assembly of TiO2 NPs in multiple layers was selected. For this, surface modification of the substrate and of TiO2 nanoparticles (NPs) with e.g. silane coupling agents is a prerequisite. First attempts to prepare the self-assembled coating on the functionalized glass substrates seem to indicate that the functionalized NPs adhere to the substrates, even if the final coatings were not homogenous and presented agglomerates. ToF-SIMS results support this outcome.
In order to use the layer-by-layer deposition technique for the formation of TiO2 films by controlled self-assembly of the TiO2 NPs, the proper complementary moieties for the functionalization of the NPs were chosen. A first set of NPs has been produced by reaction with (3-aminopropyl)phosphonic acid (APPA) in order to functionalize the surface with free amino-groups. Then, the complementary NP set can be obtained from an aliquot of the first one, through the conversion of free surface amino-groups to aldehydes by reaction with glutaraldehyde. A proper approach for the functionalization of two types of TiO2, commercial P25 (Evonik) and SETNanoMetro-sample labelled UT001, with APPA was developed. A second set of NPs consisting of three types of TiO2 NPs, P25 and SETNanoMetro NPs (TiO2 NPs with high specific surface area > 150 m2/g and TiO2 NPs with low size < 20 nm) was functionalized with (3-aminopropyl)triethoxysilane (APTS). As for the previous set of NPs, the complementary NP set was obtained through the conversion of free surface amino-groups to aldehydes by reaction with glutaraldehyde. EDX, AES and ToF-SIMS spectra were collected and analyzed to demonstrate the presence of the surface functionalization of the different types of TiO2 NPs.
H2Sense - Cost-effective and reliable Hydrogen Sensors for Facilitating the Safe Use of Hydrogen
(2016)
The H2SENSE (Cost-effective and reliable hydrogen sensors for facilitating the safe use of hydrogen) project promoted hydrogen primarily, but not exclusively, for its use as an alternative fuel. It brought together different stakeholders including sensor manufacturers, end-users, certification bodies and independent evaluators to ensure the optimum use of low-cost and reliable hydrogen sensors.
Project partners analysed sensor performance in real-life applications in industrial environments and identified increased requirements for sensors and for regulations, codes and standards. H2SENSE also facilitated the safe use and implementation of hydrogen as an alternative fuel by ensuring the correct use of effective hydrogen detection devices.
European scientists worked together with colleagues from the National Renewable Energy Laboratory (NREL) in Colorado, USA. They pooled their knowledge of developments in hydrogen sensor technology as well as deployment and commercialisation strategies. These benefits will be continued through trans-Atlantic inter-laboratory sensor testing programmes in which EU and US laboratories perform complementary tests and exchange results.
Biosensors, as defined by Pure and Applied Chemistry, are ‘chemical sensors in which the recognition System utilizes a biochemical mechanism. The biological recognition system translates information from the biochemical domain, usually an analyte concentration, into a chemical or physical output signal with a defined sensitivity’.(1) It is also appointed that chemical or biological sensors contain two basic components connected in series: a chemical or biomolecular recognition System (receptor) and a physicochemical transducer. According to this prerequisite, this overlook is confined to sensor devices that combine a biomolecular recognition element with an optical signal transducer. Homogeneous or intracellular assays using fluorescent molecular probes or nanoparticles are not considered, although they are frequently termed as molecular sensors or nanosensors in the literature.
Fluorescence-based biosensors are generalized as those devices that derive an analytical signal from a photoluminescent (either fluorescence or phosphorescence) emission process. Chemi- or bioluminescent detection systems are only briefly discussed in this review.
Biosensors are used for a wide variety of tasks, including detection of compounds of biomedical, environmental or defense interest; on-line monitoring for process control; quality control of foodstuffs; selective detection of compounds undergoing a chemical separation; and screening of drug compounds. Advantages of such devices include high selectivity, rapid response times, reusability, amenability to remote analysis, and immunity to electrical interferences. The selective nature of complexation between biomolecule and analyte and the small size of sensor devices can be combined with advanced detection techiques such as total internal reflection (TIR) spectroscopy. This results in an ability to measure analytes in complex matrices with unsurpassed sensitivity. Such samples may include highly scattering components such as milk or whole blood,(11) or relatively inaccessible locations such as groundwater wells, or even intracellular environments. The key limitation of such devices mainly centers on the poor stability of biological compounds, which can lead to a substantial drift in instrumental response over time. The so-called Cambridge Definition appoints another characteristic property of sensors. Therein, they are defined as ‘miniaturized devices which can deliver real-time and on-line information on the presence of specific compounds or ions in even complex samples’. Accordingly, a sensor is expected to respond reversibly and continuously. With the exception of some enzymatic sensors, these conditions are not fulfilled in case of most biosensors. Particularly, in devices where immunological reagents or DNA are used as recognition elements, they show a lack of reversibility and operate only as a ‘one-shot’ screen, without the potential for continuous, quantitative analysis. Nevertheless, the designations immunosensors or DNA sensors became accepted for such analytical or diagnostic tools.
There is a high demand of monitoring in the era of QbD in industrial scale require new approaches to gain data rapidly and of sufficient quality in real time. Raman spectroscopy technology has great potential but not yet shown it fully in process on-line monitoring due to limitations such as i) uncomplete separation between cells and growth media alone, ii) general weak Raman signals of analytes in complex solutions and iii) strong background signals such as the auto-fluorescence, cosmic rays and surrounding lights overlapping the weak Raman signals. Here we demonstrate a Proof-of-Concept on an the example lactic acid bacteria process using a Streptococcus thermophiles fermentation. Results from three different Raman approaches are presented: 1) Time-Gated Raman Spectroscopy (TG-Raman), 2) Surface Enhanced Raman Spectroscopy (SERS) and 3) Raman process spectroscopy with NIR excitation combined with multivariate data analysis (MVDA) using Principal Component Analysis (PCA) and Partial Least Squares Regression (PLSR).
Ultrasonic methods are well established in various aspects of concrete testing. They are used for imaging the interior geometry of constructions, estimation of concrete strength or monitoring lab investigations. However, so far the detection of distributed damages, especially in an early stage, has been almost impossible. The arrival of new technologies as deep penetration ultrasonic echo devices, new imaging techniques, embedded transducers for permanent monitoring and sensitive data processing techniques adopted from seismology have opened new fields of work. Recent research has been focused to detect changes in concrete elements induced by stress, temperature, moisture or chemical attacks.
A strongly fluorescent organic semiconducting polymer doped with a highly
temperature dependent fluorescent europium(III) complex is converted into a
nanosized material that is capable of optically sensing temperature (T) in the
range from 0 to 50 °C via two-photon excitation at 720 nm. The nanosensors
are prepared from a blue-fluorescent polyfluorene that acts as both a lightharvesting
antenna (to capture two-photon energy) and an energy donor in a
fluorescence resonance energy transfer (FRET) system. The photonic energy
absorbed by the polymer is transferred to the T-sensitive red-luminescent
europium complex contained in the nanoparticles. The close spatial proximity
of the donor and the acceptor warrants efficient FRET. A poly(ethylene glycol)-
co-poly(propylene oxide) block copolymer is also added to render the particles
biocompatible. It is shown that T can be calculated from a) the intensity of
the luminescence of the europium complex, b) the ratio of the intensities of
the red and blue luminescence, or c) the T-dependent luminescence lifetime
of the Eu(III) complex.
The presentation will give an overview on non-destructive testing techniques being developed at the Federal Institute for Materials Research and Testing, Germany (BAM). This includes ultrasonic methods, ground penetration radar, Laser-Induced Breakdown Spectroscopy (LIBS), infrared thermography, pile testing, sensor technology and building scanner. A focus of the talk will be ultrasonic methods, which are well established in various aspects of concrete testing. They are used for imaging the interior geometry of constructions, estimation of concrete strength or monitoring lab investigations. However, so far the detection of distributed damages, especially in an early stage, has been almost impossible. The arrival of new technologies as embedded transducers and sensitive data processing techniques adopted from seismology has opened new field of work. Recent research has been focused to detect changes in concrete elements induced by stress, temperature, moisture or chemical attacks by permanent monitoring. Techniques as Coda Wave Interferometry can resolve changes in ultrasonic velocity in the order of 1*10-5. In addition, many researchers believe that the investigation of nonlinear effects can be used to characterize damages. The presentation will give a wrap up of ultrasonic techniques currently used in practice. This will include echo based methods as multi-channel/multi-offset imaging of structural elements using commercial and prototype devices. Imaging methods as SAFT and RTM will be shortly discussed. The focus will be on the emerging techniques used for monitoring. New types of sensors will be presented as well as the devices used in laboratory and field applications. Insight will be given on the various influence factors on ultrasonic signals and various ways of feature extraction and data processing. The results of lab experiments will be shown to demonstrate the detection of various kind of damages from mechanical load, ASR, corrosion to fatigue. The experiences with our first installations in real constructions (bridges, tunnel) will also be presented.
The presentation will give an overview on non-destructive testing techniques being developed at the Federal Institute for Materials Research and Testing, Germany (BAM). This includes ultrasonic methods, ground penetration radar, Laser-Induced Breakdown Spectroscopy (LIBS), infrared thermography, pile testing, sensor technology and building scanner. A focus of the talk will be ultrasonic methods, which are well established in various aspects of concrete testing. They are used for imaging the interior geometry of constructions, estimation of concrete strength or monitoring lab investigations. However, so far the detection of distributed damages, especially in an early stage, has been almost impossible. The arrival of new technologies as embedded transducers and sensitive data processing techniques adopted from seismology has opened new field of work. Recent research has been focused to detect changes in concrete elements induced by stress, temperature, moisture or chemical attacks by permanent monitoring. Techniques as Coda Wave Interferometry can resolve changes in ultrasonic velocity in the order of 1*10-5. In addition, many researchers believe that the investigation of nonlinear effects can be used to characterize damages. The presentation will give a wrap up of ultrasonic techniques currently used in practice. This will include echo based methods as multi-channel/multi-offset imaging of structural elements using commercial and prototype devices. Imaging methods as SAFT and RTM will be shortly discussed. The focus will be on the emerging techniques used for monitoring. New types of sensors will be presented as well as the devices used in laboratory and field applications. Insight will be given on the various influence factors on ultrasonic signals and various ways of feature extraction and data processing. The results of lab experiments will be shown to demonstrate the detection of various kind of damages from mechanical load, ASR, corrosion to fatigue. The experiences with our first installations in real constructions (bridges, tunnel) will also be presented.
Ultrasonic methods are well established in various aspects of concrete testing. They are used for imaging the interior geometry of constructions, estimation of concrete strength or monitoring lab investigations. However, so far the detection of distributed damages, especially in an early stage, has been almost impossible. The arrival of new technologies as embedded transducers and sensitive data processing techniques adopted from seismology has opened new field of work. Recent research has been focused to detect changes in concrete elements induced by stress, temperature, moisture or chemical attacks by permanent monitoring. Techniques as Coda Wave Interferometry can resolve changes in ultrasonic velocity in the order of 1*10-5. In addition, many researchers believe that the investigation of nonlinear effects can be used to characterize damages. The presentation will give a wrap up of ultrasonic techniques currently used in practice. This will include echo based methods as multi-channel/multi-offset imaging of structural elements using commercial and prototype devices. Imaging methods as SAFT and RTM will be shortly discussed. The focus will be on the emerging techniques used for monitoring. New types of sensors will be presented as well as the devices used in laboratory and field applications. Insight will be given on the various influence factors on ultrasonic signals and various ways of feature extraction and data processing. The results of lab experiments will be shown to demonstrate the detection of various kind of damages from mechanical load, ASR, corrosion to fatigue. The experiences with or first installations in real constructions (bridges, tunnel) will also be presented.
Ultrasonic methods are well established in various aspects of concrete testing. They are used for imaging the interior geometry of constructions, estimation of concrete strength or monitoring lab investigations. However, so far the detection of distributed damages, especially in an early stage, has been almost impossible. The arrival of new technologies as embedded transducers and sensitive data processing techniques adopted from seismology has opened new field of work. Recent research has been focused to detect changes in concrete elements induced by stress, temperature, moisture or chemical attacks by permanent monitoring. Techniques as Coda Wave Interferometry can resolve changes in ultrasonic velocity in the order of 1*10-5. In addition, many researchers believe that the investigation of nonlinear effects can be used to characterize damages.
The workshop will give a wrap up of ultrasonic techniques currently used in practice. This will include echo based methods as multi-channel/multi-offset imaging of structural elements using commercial and prototype devices. Imaging methods as SAFT and RTM will be shortly discussed.
The focus will be on the emerging techniques used for monitoring. New types of sensors will be presented as well as the devices used in laboratory and field applications. Insight will be given on the various influence factors on ultrasonic signals and various ways of feature extraction and data processing. The results of lab experiments will be shown to demonstrate the detection of various kind of damages from mechanical load, ASR, corrosion to fatigue. The experiences with or first installations in real constructions (bridges, tunnel) will also be presented.
We present an in situ investigation of the mechanochemical formation of cocrystals using synchrotron XRD and Raman spectroscopy. This combination allows to study milling processes on the level of the molecular and crystalline structure thus obtaining reliable data for mechanistic studies. Thereby, mechanochemical syntheses can be optimized to isolate new crystal structures.
29Si{27Al} TRAPDOR MAS NMR was applied to two faujasite-type zeolites with Si/Al ratios of 1.3 (Na-X) and 2.7 (Na-Y). The aim of this test study is to show that different Q4(mAl) sites (m=4,3,2,1) can be distinguished by differently strong TRAPDOR effects (ΔS/S0). Indeed, it was found that the TRAPDOR effect depends on the number m of AlO4 units connected to the Q4 silicon tetrahedrons. For Na-X, the measured ΔS/S0 values are 1:0.81:0.56 for Q4(4Al), Q4(3Al) and Q4(2Al), respectively (normalized to Q4(4Al)). The corresponding ΔS/S0 values are the same for Na-Y within the error bars, although the silicon sites are different: Q4(3Al), Q4(2Al) and Q4(1Al) and now normalized to Q4(3Al) as no Q4(4Al) is present. Nevertheless, the proposed method opens up the possibility to distinguish overlapping 29Si NMR signals of the Qn(mAl) sites in amorphous materials as the main goal of these investigations.
For versatile applications, including vacuum instrumentation, a liquid cell was developed. Using ultra-thin windows, this cell enables X-ray Absorption spectrometry in the soft X-ray range which is in particular interesting for the analysis of organic molecules in liquids or at the solid-liquid interface.
NEXAFS of a protein at N K-edge and of chlorophyll a at Mg K-edge is demonstrated.
In this work, fullerene has been functionalized with cyanuric Chloride at room temperature by a nitrene mediated [2 + 1] cycloaddition reaction. The adduct after functionalization is inherently in the form of azafulleroid and shows broad UV absorption in the wavelength range of 200–800 nm, as well as photothermal conversion and fluorescence with a high quantum yield.
2PM FlySCAN: Innovative approach for wide field high resolution imaging of skin tissue volumes
(2016)
Two Photon Microscopy (2PM) is an innovative Technology for high resolution imaging of human skin in vivo and ex vivo. Up to now the method is limited by its interdependence between the field of view and the attainable resolution. The new FlySCAN Technology overcomes these boundaries and enable images sizes of many millimeters by resolutions in the submicrometer range revealing very specific information on clinically and biologically relevant tissue and cell structures. The advantages of the new approach are demonstrated by excellent in vivo and ex vivo tissue images.
Copper(II)phenanthroline complexes intercalate into DNA and induce DNA cleavage. Here, we investigate the nuclease activity of copper(II)phenanthroline complexes on Silicon nitride films. 1,10-phenanthroline-5-carboxylic acid is immobilized at Si-NHx bonds via amide coupling followed by the formation of copper(II)phenanthroline complexes. XPS and NEXAFS were carried out at the HE-SGM beamline.
Multi-resistant bacteria embedded in infectious biofilms are one of the largest future threats in human healthcare. The mechanism of drug uptake and the origin of resistancy is quantitatively not well characterized and understood. Modern X-ray and synchrotron excited spectroscopic methods like XRF and NAP-XPS under ambient pressure conditions and liquid media will add new insights into this field.
Graphene prepared from Graphene oxide (GO) is used as a platform for functional 2D nanomaterials with diverse applications ranging from bios ensors to antimicrobial surfaces. C and N K-edge NEXAFS and XPS spectroscopies at BESSY’s HE-SGM beamline have been used to prove and control covalent functionalization of graphenic materials at ambient conditions for the synthesis of functional 2D-surfaces.
A novel photoswitchable rotaxane was synthesised and its switching behaviour in solution was analysed with NMR and UV-Vis. A monolayer of rotaxanes was deposited on glass surfaces and the on-surface photoswitching was investigated. Angle-resolved NEXAFS spectra revealed a preferential orientation that reversibly changes upon switching.
An automatic sample changer chamber for total reflection X-ray fluorescence (TXRF) and X-ray absorption near-edge structure (XANES) analysis in TXRF geometry was successfully set up at the BAMline at BESSY II. TXRF and TXRF-XANES are valuable tools for elemental determination and speciation, especially where sample amounts are limited (<1 mg) and concentrations are low (ng ml⁻¹ to μg ml⁻¹). TXRF requires a well defined geometry regarding the reflecting surface of a sample carrier and the synchrotron beam. The newly installed chamber allows for reliable sample positioning, remote sample changing and evacuation of the fluorescence beam path. The chamber was successfully used showing accurate determination of elemental amounts in the certified reference material NISTwater 1640. Low limits of detection of less than 100 fg absolute (10 pg ml⁻¹) for Ni were found. TXRF-XANES on different Re species was applied. An unknown species of Re was found to be Re in the +7 oxidation state.
A reversed phase high performance liquid chromatography coupled to an inductively coupled plasma mass spectrometer (HPLC-ICP-MS) approach in combination with isotope dilution analysis (IDA) for the separation and parallel quantification of nanostructured and ionic silver (Ag) is presented. The main focus of this work was the determination of the ionic Ag concentration. For a sufficient stabilization of the ions without dissolving the nanoparticles (NPs), the eluent had to be initially optimized. The determined Ag ion concentration was in a good agreement with results obtained using ultrafiltration. Further, the mechanism of the NP separation in the HPLC column was investigated. Typical size exclusion effects were found by comparing results from columns with different pore sizes. Since the recovery rates decreased with increasing Ag NP size and large Ag NPs did not elute from the column, additional interactions of the particles with the stationary phase were assumed. Our results reveal that the presented method is not only applicable to Ag NPs, but also to gold and polystyrene NPs. Finally, IDA-HPLC-ICP-MS experiments in single particle mode were performed to determine the particle cut-off size. The comparison with conventional spICP-MS experiments resulted in a similar diameter and particle size distribution.
Objectives:
Dental peri-implantitis is characterized by a multifactorial etiology. The role of metal elements as an etiological factor for peri-implantitis is still unclear. The aim of this study was to investigate the incidence of metal elements in bone and mucosal tissues around dental Grade 4 CP titanium implants with signs of peri-implantitis in human patients.
Methods:
In this prospective pilot study, all patients were enrolled consecutively in two study centers. Bone and soft tissue samples of patients with peri-implantitis with indication for explantation were analyzed for the incidence of different elements (Ca, P, Ti, Fe) by means of
synchrotron radiation X-ray fluorescence spectroscopy (SRXRF) and polarized light microscopy (PLM). The existence of macrophages and lymphocytes in the histologic specimens was analyzed.
Results:
Biopsies of 12 patients (seven bone samples, five mucosal samples) were included and analyzed. In nine of the 12 samples (75%), the SRXRF examination revealed the existence of titanium (Ti) and an associated occurrence with Iron (Fe). Metal particles were detected in peri-
implant soft tissue using PLM. In samples with increased titanium concentration, lymphocytes were detected, whereas M1 macrophages were predominantly seen in samples with metal particles.
Conclusion:
Titanium and Iron elements were found in soft and hard tissue biopsies retrieved from peri-implantitis sites. Further histologic and immunohistochemical studies need to clarify which specific immune reaction metal elements/particles induce in dental peri-implant tissue.
The project addresses chemical and topographical metrology at surfaces. The new methodologies of measurements at surfaces will be developed as good practice guides and new work item proposals for industrial ISO standards. The objectives of the Joint research project (JRP) are to provide measurement standards and methods with traceability wherever it is practicable to do so for quantitative surface chemical analysis for industrial applications.
A new concept for the self-diagnosis of embedded fiber Bragg grating (FBG) strain sensors was developed, simulated and experimentally tested. This concept is based on a magnetostrictive metallic layer directly coated on the fibre cladding over the grating segment of the FBG sensor, so that an on-demand external magnetic field in a millitesla scale can produce a controllable artificial strain as an indication signal for the remote optical interrogator. The relationship between the pre-defined magnetic field and its induced Bragg wavelength shift characterizes this validation concept. Any deviation of the local bonding state of the interfaces from the initial or/and any change of shear strain transferring mechanism from composite matrix to the optical fibre core will result in alterations in this sensitive relationship, and thus triggers an immediate alert for a further inspection. The finite element method is used to simulate the strain of this configuration as result of different values of the magnetic field in order to optimize the geometrical sensor parameters. The simulations are verified by experiments results. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
The European Water Framework Directive (WFD) 2000/60/EC specifies a list of 33 priority water pollutants. For these substances, Environmental Quality Standards (EQS), equivalent to the maximum allowable concentrations, had been defined at very low levels.
EQS values refer to the whole water body, i.e. include contaminants which are associated to suspended solids or colloids present in the natural water. For several priority pollutants primary analytical methods capable of measuring the target analytes at EQS level in natural water are still missing. The project has developed and validated such methods for three selected compounds, namely Tributyltin (TBT), Polybrominated Diphenylether (PBDE) and Polycyclic Aromatic Hydrocarbons (PAH).
Trans-Zearalenone(ZEN)is a non-steroidal estrogenic mycotoxin which frequently contaminates cereal grains worldwide. Ingestion of food and feed containing ZEN causes numerous mycotoxicoses in animals and possibly humans with pronounced estrogenic effects. Due to the trans-configurated double bond, ZEN isomerizes to the cis-configuration upon the influence of light. This work investigates the instrumental analysis, metabolism and toxicity of ZEN and cis- ZEN. The first part focused on the determination of ZEN in edible oils. Due to a maximum level of 400 µg/kg ZEN in the European Union (EU), reliable analytical methods are needed. A comprehensive method comparison proved dynamic covalent hydrazine chemistry (DCHC) to be the most suitable approach. Thus, an automated solid phase extraction (SPE) coupled online to high performance liquid chromatography (HPLC) was developed with the novelty of a covalent SPE step comprising the DCHC principle. The automated online system allows an accurate, selective and reliable quantification of ZEN in edible oils in compliance with EU performance criteria while significantly reducing workload and thereby personnel costs. In contrast to ZEN, reference standards and analytical methods are missing for cis- ZEN which causes a lack of data on the occurrence, fate and risks of cis-ZEN. Therefore, a native and an isotopically labeled cis-ZEN standard were synthesized and implemented in an existing stable isotope dilution analysis HPLC tandem mass spectrometry (HPLC-MS/MS) method. Using this method, a large extent of cis-ZEN formation was observed for ZEN contaminated maize germ oils when exposed to daylight which confirms that cis-ZEN can be a relevant food contaminant and should be considered in the analysis of food and feed. Furthermore, this work investigated the in vitro phase I metabolism of ZEN and cis-ZEN in rat and human liver microsomes by using HPLC-MS and -MS/MS analyses. The metabolic pathways of cis-ZEN were found to be essentially similar to ZEN including reduction and oxidation reactions generating α- and β-cis- zearalenol as well as 13- and 15-OH-cis-ZEN. A previously unidentified oxidative metabolic pathway for both isomers of ZEN results in the formation of cis-ZEN-11,12-oxide and ZEN-11,12-oxide in human liver microsomes. The estrogenicity of cis-ZEN and its reductive metabolites was assessed using the E-Screen assay. cis-ZEN proved to be slightly more estrogenic than ZEN. Biotransformation of cis-ZEN to β-cis-ZEL corresponds to a detoxification, whereas metabolism to α-cis-ZEL resembles a metabolic activation as its estrogenicity considerably exceeds that of cis-ZEN. The catecholic metabolites can be expected to show a decreased estrogenicity as demonstrated for 15-OH- ZEN. Independent of the estrogenic effects, the catecholic and epoxidic metabolites identified in this work can be expected to act genotoxic and carcinogenic. The epoxides in particular could fundamentally change the widely accepted view of ZEN causing adverse effects exclusively through endocrine disrupting actions.
The main task of BAM in the I4S project is the development of online analytics for reliable monitoring of major and minor nutrients like K, P, Ca in soil using mobile-XRF (X-ray fluorescence spectroscopy) and mobile-LIBS (laser-induced breakdown spectroscopy). Each method provides fast and simultaneous multi-element analyses which are neccessary for mapping agricultural cropland. The first objective was to design a combined measurement setup for XRF and LIBS. The centerpiece is the rotatable sample plate which enables the measurement of moving samples. Current steps are the optimisation of the parameters for the analysis of soils.
Production of soil reference materials (for project partners) is integrated into the project „X-ray fluorescence, laser-induced breakdown spectroscopy (and Raman spectroscopy) as tools for a site-specific management of soil fertility“. BAM provides good analytics which is necessary for measuring the right values. Why is it important to have reference values? They enable the connection of own measuring results to the SI (international system of units) and the comparison with results from other laboratories. The soil reference materials are also needed for the calibration of the matrix dependent methods laser-induced breakdown spectroscopy (LIBS) and X-ray fluorescence analysis (XRF). For the production of soil reference materials different steps are required, for example drying, sieving and homogenisation.
The main task of BAM in the I4S project is the development of online analytics for reliable monitoring of major and minor nutrients like K, P, Ca in soil using mobile-XRF (X-ray fluorescence spectroscopy) and mobile-LIBS (laser-induced breakdown spectroscopy). Each method provides fast and simultaneous multi-element analyses which are neccessary for mapping agricultural cropland. The first objective was to design a combined measurement setup for XRF and LIBS. The centerpiece is the rotatable sample plate which enables the measurement of moving samples. Current steps are the optimisation of the parameters for the analysis of soils.