Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (48)
- Zeitschriftenartikel (19)
- Posterpräsentation (15)
- Buchkapitel (1)
- Beitrag zu einem Tagungsband (1)
- Dissertation (1)
Schlagworte
- Synchrotron (85) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (48)
The newly developed EXAFS set-up comprises both time- and spatially-resolved EXAFS information simultaneously in a single-shot. This facile, stable and scanningless set-up was tested at the BAMline @ BESSY-II (Berlin, Germany). The primary broadband beam is generated by a filter/X-ray-mirror combination (bandpass). The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by an area sensitive detector based on a CCD camera, in a theta - 2 theta geometry.
The first in situ measurements were successfully carried out and hereby presented. The case-study involved a well known reaction, in which structural changes are induced over time, and continuously measured. We were able to track structural changes within a 1s time resolution.
Gold mosaics, made from gold and glass, are one of the best expressions of Late Antique Byzantine and Early Islamic art. The gold alloys, whose composition seems to indicate that gold coins were re-used to fabricate the tesserae, can be used to provide information on the mosaics chronology. Monetary Byzantine gold is in fact characterized by the presence of Pt, which contents in the gold alloy change over time, but Pt must be measured in 0.2-0.4 µm thickness gold leaves that were beaten to be sandwiched between two glass layers.
To analyze this samples the D²XRF set-up at the BAMline at the BESSY synchrotron in Berlin was used. The combination of a crystal for wavelength dispersion and an energy resolving single photon counting pnCCD allows the realization of this very simple wavelength dispersive detection system. With this system an MDL of 1 μg/g for the determination of Pt in Au under optimal conditions can be reached.
Gold leaf tesserae from nine archaeological sites, covering the period that goes from the 5th c. to the 8th c., were analyzed. The presence of Pt in the majority of the samples confirmed the re-use of coins. The Pt contents separate the samples in three groups, one of which having the same chemical characteristics as the Byzantine gold could be compared to dated coins for chronology. The higher Pt contents for one of other groups suggest
Die Mitte des 16. Jahrhunderts gegründete Dresdener Goldschmiedeinnung, geriet im 19. Jahrhundert in wirtschaftliche Schwierigkeiten, was letztendlich zu ihrer Auflösung führte. Im Zuge dessen wurde 1872 auch der historische Innungspokal für 80 Taler an das Grüne Gewölbe in Dresden verkauft. Sowohl das Empfehlungsschreiben des damaligen Direktors als auch die Zustimmung zum zügigen Ankauf dürften Beleg dafür sein, dass man damals der festen Überzeugung war, ein etwa 250 Jahre altes, authentisches Silbergefäß erworben zu haben. Die aktuelle kunstwissenschaftliche Begutachtung des Innungspokals lässt begründete Fragen zum Alter und zur Originalität des Objektes, welches heute in der Sammlung des Grünen Gewölbes präsentiert wird, aufkommen. Die kunst-wissenschaftliche und kunsttechnologische Expertise reicht hier allein ftir eine gesicherte Altersbestimmung nicht aus und soll deshalb durch naturwissenschaftliche Untersuchungen zur Materialzusammensetzung unterstützt werden.
Wilson´s disease, a rare genetic disorder of the copper metabolism, causes the copper accumulation in various organs, leading to manifold hepatic, neurological and psychiatric symptoms. To study the elemental distribution, human Wilson´s disease liver samples were analyzed by means of LA-ICP-MS. Results demonstrated an inhomogeneous copper and iron distribution in human liver with hotspots of very high intensities. Both elements were quantified by an external calibration using matrix-matched standards made of gelatin, showing concentrations up to several thousand micrograms per gram. Additionally, results were validated by means of synchrotron radiation based μXRF at the BAMline at BESSYII (Helmholtz-Zentrum Berlin).
Wilson´s disease (WD) is a rare genetic disorder of the copper metabolism, causing the accumulation of copper in different organs, including the liver, the central nervous system and cornea. This way, WD initiates manifold hepatic, neurological or psychiatric symptoms. To learn about the elemental distribution and present species in WD, liver samples were analyzed by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), micro X-ray fluorescence (μXRF) and X-ray absorption near edge structure spectroscopy (XANES).
Within this work, LA-ICP-MS was applied to study the distribution of copper and iron in human liver samples, which were collected by a liver biopsy of WD and control patients within a medical investigation. The analysis by LA-ICP-MS was performed with a 213 nm Nd:YAG laser using a spatial resolution of 10 μm and a scan rate of 20 μm/s. In a next step, copper and iron were quantified by LA-ICP-MS using homemade matrix-matched standards made of gelatin. Results showed an inhomogeneous copper and iron distribution in human liver with hotspots up to several thousand micrograms per gram liver within the hepatocytes.
Additionally, results for the elemental distribution in WD were validated by means of synchrotron radiation-based μXRF with a beam size of 4 μm at the BAMline at BESSYII (Helmholtz-Zentrum Berlin). Furthermore, XANES was performed to identify the present oxidation states of copper in WD, indicating a mixture of copper(I) and copper(II) within the liver tissue.
In the contemporary medicine, rhodanine staining is routinely used to determine the copper distribution in liver tissues. Nevertheless, this method does not provide results with a high sensitivity in comparison to LA-ICP-MS. Therefore, the presented LA-ICP-MS method offers a new possible diagnostic tool. These results may also contribute to a better understanding of Wilson´s disease and its development.
Airborne particulate matter is an issue of growing concern in industrialized countries.
Particles with diameters of less than 10 μm, in particular those with less 2.5 μm, are of special
concern, as they can enter the human lungs and contribute to various cardiovascular and
respiratory diseases. As the composition and health effects of airborne particles in urban, rural
and industrial outdoor air has been studied abundantly, our focus lies on the analysis of
airborne particle samples collected indoors, which may also have a significant effect on
human health, depending on the chemical composition of the particles and the chemical
bonding state, in which elements are present. This chemical speciation can be obtained using
X-ray absorption near edge structure (XANES) analysis, which requires a tunable excitation
source and therefore has to be carried out at synchrotron facilities. For this work, samples
were collected in office rooms of the Atominstitut building.
The BAMline at BESSYII, Berlin, features a double-multilayer monochromator (DMM) and a
double-crystal monochromator (DCM). The DCM offers an energy resolution E/ΔE of around
103, which makes it suitable for X-ray absorption fine structure (XAFS) applications. The
Atominstitut SR-TXRF vacuum chamber, formerly located at HASYLAB, Beamline L, is
now available at the BAMline. The chamber offers a sample changer for up to 8 quartz
carriers suitable for total reflection X-ray fluorescence analysis (TXRF) and was equipped
with a 30 mm² silicon drift detector (SDD). Aerosol samples were produced using a modified
three-stage Dekati™ impactor. For this work, only the coarse (2.5 to 10 μm, Stage 2) and the
fine particle fraction (1 to 2.5 μm, Stage 3), were of interest. XANES analysis was performed
for the elements Cr, Cu and Zn. Oxidation states of these 3 elements will be presented.
The X-ray Fluorescence beamline at ELETTRA operates in partnership with the IAEA an
ultra-high vacuum instrument with a 7-axis manipulator suitable for a variety of X-ray
analytical techniques, such as grazing incidence X-ray fluorescence analysis (GI-XRF),
TXRF, X-ray reflectometry (XRR) and XANES. Samples were produced using a four-stage
Sioutas Personal Cascade Impactor. With this impactor, it is possible to produce sizefractionated
samples down to the sub-μm range (Stages: A > 2.5 μm, B 1 to 2.5 μm, C 0.5 to
1 μm and D 0.25 to 0.5 μm). Direct sampling was performed on siliconized 25 mm Si wafers
suitable for TXRF. Cu-K edge SR-TXRF-XANES analysis was carried out for samples of all
impactor stages. Results of these experiments will be shown.
Airborne particulate matter is an issue of growing concern in industrialized countries. Particles with diameters of less than 10 μm (especially those smaller than 2.5 μm) can enter the human respiratory system and contribute to various diseases depending on their chemical composition and the chemical bonding state, in which elements are present. This chemical speciation can be obtained using X-ray absorption near-edge structure analysis (XANES), which requires a tunable excitation source and therefore has to be carried out at synchrotron facilities. Our special interest lies on the analysis of indoor airborne particulate matter, as particle composition and health effects of outdoor particles have been studied abundantly. For this work, samples were collected in various office rooms in the Atominstitut (ATI) building.
The BAMline at BESSYII features a double-multilayer monochromator (DMM) and a double-crystal monochromator (DCM). The DCM offers an energy resolution E/ΔE of around 103, which makes it suitable for XANES applications. The ATI SR-TXRF vacuum chamber, formerly located at HASYLAB, Beamline L, is now available at the BAMline. The chamber offers a sample changer for up to 8 quartz reflectors and a 30 mm² silicon drift detector (SDD) was used. Aerosol samples were produced using a modified three-stage Dekati™ impactor. For this work, only the coarse (2.5 to 10 μm) and the fine particle fraction (1 to 2.5 μm), were of interest. XANES results of Cr, Cu and Zn will be presented on this poster.
The X-ray Fluorescence beamline at ELETTRA operates in partnership with the IAEA an ultra-high vacuum instrument with a 7-axis manipulator suitable for a variety of X-ray analytical techniques, such as grazing incidence and total reflection X-ray fluorescence analysis (GI-XRF and TXRF), X-ray reflectometry (XRR) and XANES. Samples were produced using a four-stage Sioutas Personal Cascade Impactor. With this impactor, it is possible to produce size-fractionated samples down to the sub-μm range (Stages: A > 2.5 μm, B 1 to 2.5 μm, C 0.5 to 1 μm and D 0.25 to 0.5 μm). Direct sampling was performed on siliconized 25 mm Si wafers suitable for TXRF. Cu-K edge SR-TXRF-XANES analysis was carried out for samples of all impactor stages. Results of these experiments will be shown.
High Speed, High Resolution imaging spectrometers based on pnCCDs for XRF and XRD applications
(2016)
For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light sources in large accelerator facilities as well as with laboratory light sources or with X-rays from celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF) measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of structure and dynamics of matter.
High Speed X-ray Imaging and Spectroscopy with pnCCDs: XRF, XRD and PIXE measurements (and others)
(2016)
For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in
many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light
sources in large accelerator facilities as well as with laboratory light sources or with X-rays from
celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF)
measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced
X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing
experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will
be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects
in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of
structure and dynamics of matter.
In this study a metal-matrix-composite with aluminum matrix and Al2O3 particles was investigated with x-ray refraction topography and in-situ tensile loading. It could be observed that after reaching a certain load the specific surface increased steadily. However, the classical radiographs taken for comparison show no damage in the sample.
Time-resolved in situ investigation of Portland cement hydration influenced by chemical admixtures
(2016)
Numerous admixtures are used in the building practice to customize the properties of the cement paste during application. The influences of admixtures on the course of cement hydration and formation of hydrate phases have to be considered. Polycarboxylate ether (PCE) based polymeric superplasticizers (SPs) are known to retard the setting of the cement paste. The extent of the retardation differs depending on the molecular structure of the SP. Additionally, the presence of a stabilizing agent (SA) in the cement paste has a retarding side effect on the setting. The initial cement hydration processes and the detailed mechanisms of the retardation influenced by PCEs, as well as their interactions with particular SAs, are insufficiently understood. Up to now, only the results of phenomenological studies were taken into account to describe this retardation process. A detailed structure analysis monitoring the change of the phase composition during the hydration was never applied. Both SP and SA affect the adsorption of the sulphate ions on the clinker particles, causing changes in the formation of ettringite during the initial hydration, and are therefore a crucial part of the setting process itself. Here, the initial hydration of cement influenced by the interaction of SP and SA was monitored in situ by synchrotron X-ray diffraction. The high time resolution of the measurements allowed a continuous detection of the hydrates formed. The hydration was followed from the starting point of water addition and for couple of hours afterwards. The hydration of the levitated cement pellets containing starch as SA was initialized by adding aqueous solutions of different commercial SPs. Changes in the ettringite formation were detected in comparison to the reference hydration of pure cement.
Synchrotron-radiation enables the adjustment of the XPS information depth and, thus, the visualization of depth profiles of the elemental composition within the first 10 nm of a surface. This project deals with the analysis of core-shell nanoparticles. It constitutes first steps towards a valid methodology for studying the surface chemistry of nanoparticles in a quantitative and accurate manner.
The gold finds from Bernstorf, in the Freising district of Bavaria, were discovered in 1998, in the area of a Bronze Age settlement. First analyses with X-ray fluorescence (XRF) revealed gold of an unusually high purity grade, which was explained by using cementation techniques.
A newer analysis with laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) indicated an even higher purity. These analytical results were the starting point of an ongoing discussion. The amount and type of the detected contaminants were highly controversial and led to contradictory interpretations.
We reanalysed 11 gold samples with synchrotron radiation induced X-ray fluorescence (SRXRF) at the BAMline at BESSY-II. To reach the desired detection limits a thorough analysis with three different excitation energies and detection conditions were applied to confirm or disprove the previous results.
In this contribution we will get into the details for the need of the different measurement conditions and the virtues of the use of synchrotron radiation. The use and effectiveness of cementation techniques will be addressed. Finally we will present the achieved results and their impact on the discussion.
The BAMline at the synchrotron BESSY II in Berlin supplies users with up to date analytical x-ray methods for the energy range between 5 and 50 keV. Additional to XRF with micron Resolution it provides amongst other things the possibility to use TXRF and XANES. Especially the use of
the so-called Color X-Ray Camera (CXC) opens the possibility to use new and effective detection schemes, which allow to measure simultaneously distributions of elements or Absorption spectra in a motionless mode.
In this talk the analytical possibilities at the BAMline for samples with biological Background will be introduced. The available methods will be presented and discussed for various examples.
A perspective for the future use for XANES in grazing emission and TXRF geometries for plant materials will be given.
Die Eigenschaften und die Verlässlichkeit von Materialien jeglicher Art sind seit jeher die Grundlagen der Technik einer Gesellschaft. Tiefgreifende Kenntnisse über sie sind deshalb eine Voraussetzung um neue Produkte zu entwickeln, Verlässlichkeit zu gewährleisten, oder aber auch, wie in der Archäometrie, Kenntnisse über die Vergangenheit zu gewinnen. Ein Schlüssel zum Verständnis ist das Wissen über die chemische Zusammensetzung und die Struktur von Materialien Die Analyse mit Synchrotronstrahlung bietet hierfür herausragende Werkzeuge an, die zerstörungsfrei und hochsensitiv sind. Mit Röntgenfluoreszenzanalyse kann die elementare Zusammensetzung in winzigen Proben bis auf μg/g bestimmt werden. Anwendungsbeispiele aus verschiedenen Themengebieten, aber besonders von archäologischen Fragestellungen wie z.B. dem Goldfund von Bernstorf werden im Vortrag vorgestellt.
News from the BAMline
(2017)
Airborne particulate matter is a topic of growing interest. Particles with aerodynamic diameters less than 10 μm (PM 10) and especially the fine fraction below 2.5 μm (PM2.5) are of particular importance, as they can enter the human respiratory system and cause acute and
chronic respiratory or cardiovascular diseases. The mass distribution of airborne particles in dependence of their diameters is well-known, but also the abundance and temporal variation of trace elements in air (mass concentrations down to the pg/m³ range) are crucial.
These elements originate from various natural (abrasion, erosion) and anthropogenic sources (combustion, road traffic), which complicate the discrimination between harmless and toxic emissions. Some new methods of investigation are therefore needed and X-ray fluorescence spectroscopy has ascertained ist huge potential in this matter, thanks to the possibility to determine simultaneously, in a time-resolved manner, the mass concentrations of critical elements which can be considered as markers of a potential toxic source. A method for the quantitative Analysis of airborne particles directly collected on sample substrates (30 mm quartz reflectors and 1" Si wafers suited for total-reflection X-ray fluorescence analysis (TXRF) will be presented.
Samplings were performed using a three- stage Dekati™ PM10 impactor (>10 μm, 2.5 to 10 μm and 1 to 2.5 μm) and a four-stage Sioutas Personal Cascade Impactor (>2.5 μm, 1 to 2.5 μm,0.5 to 1 μm and 0.25 to 0.5 μm) at indoor and outdoor sites at the Atominstitut (Vienna, Austria). Quantitative results of two outdoor test sampling campaigns (July 2016 and January 2017) will be presented and discussed. Low detection limits were assessed via TXRF and range from several 10 to several 100 pg/m³ depending on the element and particle size fraction.
Ein Konvolut einzelner Schmuckstücke und die Goldbeigaben eines angeblichen Grabfundes wurden technologisch und analytisch untersucht. Die meisten Objekte sind Blecharbeiten, die aus einer Vielzahl von Einzelteilen mit metallischem Goldlot zusammengefügt und mit Granulation oder granulations-imitierendem Perl- oder Kerbdraht verziert wurden. Nur vier kleine Ohrringe sind massiv gegossen.
Zwei Zierbleche dürften über Patrizen (Positivmodeln), die Deckel der Astragale in Matrizen (Negativmodeln) geformt worden sein. Alle Objekte wurden mit Synchrotron- und atmosphärischer Röntgenfluoreszenz analysiert. Die Daten zeigen das breite Spektrum an Goldlegierungen, die im 7./6. Jahrhundert v. Chr. in Kleinasien verarbeitet wurden: vom natürlichen Seifengold (Elektrum) bis zu geläutertem, fast reinem Gold. Eine Korrelation zwischen Goldqualität und Verarbeitungsmethode konnte nicht festgestellt werden. Sowohl hochreines als auch mit viel Silber und Kupfer legiertes Gold wurde zum Schmieden von Blecharbeiten, aber auch zum Massivguss verwendet. Aus der Goldfarbe kann wegen des Phänomens der oberflächlichen Goldanreicherung nicht auf eine Legierungszusammensetzung geschlossen werden. Der 1963 angekaufte Fundkomplex aus lydischen Metallarbeiten und ostionischen Salbgefäßen aus Ton dürfte einen Grabfund des frühen 6. Jahrhunderts v. Chr. darstellen, dessen Herkunft aus Ephesos jedoch nicht zu sichern ist.
In the quest for finding the ideal synchrotron-radiation-induced imaging method for the investigation of trace element distributions in human bone samples, experiments were performed using both a scanning confocal synchrotron radiation micro X-ray fluorescence (SR-mXRF) (FLUO beamline at ANKA) setup and a full-field color X-ray camera (BAMline at BESSY-II) setup. As zinc is a trace element of special interest in bone, the setups were optimized for its detection. The setups were compared with respect to count rate, required measurement time and spatial resolution. It was demonstrated that the ideal method depends on the element of interest. Although for Ca (a major constituent of the bone with a low energy of 3.69 keV for its K alpha XRF line) the color X-ray camera provided a higher resolution in the plane, for Zn (a trace element in bone) only the confocal SR-µXRF setup was able to sufficiently image the distribution.